E20 FORMULAR DE ESTIMARE A SARCINII TERMICE

FOAIE 1 din 1 DATĂ

PREGĂTIT DE Khairul Anuar Abd Jabar


NUMELE LOCULUI Upgrade D35 pentru sistemul HVAC
DE MUNCĂ
LOC Miri Serawak APROBAT

SPAȚIU UTILIZAT Cameră principală electrică


PENTRU ESTIMARE ORA LOCALĂ VÂRF Septembrie ORA LOCALĂ
MĂRIME 1,460.00 m2 X 3.60 = 5,256.00 m3 PENTRU ORA SOARELUI ÎNCĂRCA 16.00 ORA SOARELUI

CÂȘTIG DE FUNCȚIONAREA ECHIPAMENTELOR ORĂ/ZI 10 ore


ARTICOL SUPRAFAȚĂ SAU CANTITATE WAŢI
CONDIŢII .DB BM %RH DP g/kg
SOARE SAU TEMP.
FACTOR CÂȘTIG SOLAR - STICLĂ ÎN AER LIBER (OA)

NW STICLĂ m2 x x 0.57 0 CAMERĂ (RM)

N STICLĂ m2 x x 0.57 0 DIFERENȚĂ - -

SE STICLĂ m2 x x 0.57 0 AER EXTERIOR


SW STICLĂ m2 x x 0.57 0 OAMENI x 7 l/s
-
Ventilație
LUCARNĂ m2 x x 0 1 Schimbare aer/oră: m3 = 5,256 l/s = 1,460.01
/s VENTILAȚIE =
SOLAR &TRANS. GAIN - PEREȚI ȘI ACOPERIȘ l 1,460.01

NW PERETE m2 x x 3.04 0 SWINGING


N PERETE m2 x x 3.04 0 UȘĂ ROTATIVĂ

SE PERETE m2 x x 3.04 0 UȘI DESCHISE UȘI x l/s per ușă =

SW PERETE m2 x x 3.04 0 Infiltrare VENTILATOR DE


EVACUARE
ACOPERIȘ - SOARE m2 x x 0 mX l/s pe m
CRĂPĂTURĂ
ACOPERIȘ - UMBRIT m2 x x 0 l/ s INFILTRARE = -

TRAN. CÂȘTIG - CU EXCEPȚIA PEREȚILOR ȘI ACOPERIȘULUI l/s APARAT DE AER EXTERIOR PRIN = l/s OA

TOATE STICLA - m2 x - x 5.89 0 PUNCT DE ROUĂ AL APARATULUI ȘI CANTITATE DE AER DEZUMIDIFICAT

PARTIȚIE m2 x - x 0 EFICIENT SENSIBIL - ERSH


= #DIV/0!
PLAFON m2 x - x 0 FACTOR DE CĂLDURĂ - ERTH
ESHF
PODEA m2 x - x 0 ADP INDICAT = 56,00 C SELECTAT A DP = 56,00 C

INFILTRARE m2 x - x 0 ADP (4 n 1 e REN V /I .


ADP . ) (.)
CĂLDURĂ INTERNĂ Dehum. -
Răsări
POPOR - x 245 0
- ERSH - l/s DA
PUTERE KW x 1,000.00 0 Dehum. l/s 1.20 x (47.60) CDEHUM. RĂSĂRI

LUMINI WAŢI x 1.25 0 CANTITATEA DE AER DE ALIMENTARE

ELECTROCASNICE ETC. x 0 RSH =


Priză #DIV/0! C (RM - AER DE
CÂȘTIGURI SUPLIMENTARE DE CĂLDURĂ x 0 1.20 x - EVACUARE)*
Temp. Dif
l/sDA
SUBTOTAL 0 - RSH =
____________________ +
IV/0! l/s SA
DEPOZITARE m2 x x (- ) 0 Aprovizion 1.20 x #DIV/0! DIFF DORIT
are l/s
SUBTOTAL 0

FACTOR DE SIGURANȚĂ 5 % 0
Bypass l/s
CĂLDURĂ SENSIBILĂ ÎN CAMERĂ (RSH) = 0 *DACĂ ACEST DT ESTE PREA MARE, SE DETERMINĂ CFM DE ALIMENTARE PENTRU DIFERENȚA DORITĂ
APROVIZIONARE PRIN FORMULA CANTITĂȚII DE AER DE ALIMENTARE.
CÂȘTIG DE CĂLDURĂ ÎN CONDUCTA DE ALIMENTARE % + SCURGERE DE CONDUCTE %+ 0
CONDIȚIILE ORL ȘI LVG REZULTATE LA APARATURĂ
EVANTAI
% 1.460,01 l/s
AER EXTERIOR 1,460.01 l/s x - C x 0.15 BF x 1.2 0

CĂLDURĂ EFECTIVĂ SENSIBILĂ ÎN CAMERĂ (ERSH) = 0 .RM C OA


OA C -
MIRE = EDB
+
######## l/s**
CĂLDURĂ LATENTĂ 56.00 C BF x (TEDB - C - TADP 56.00 C) = TLDB 47.60 C
TA C
DP 0.15 C, TEWB
INFILTRARE l/s x g/kg x 3 0 CH. DIAGRAMĂ: TEWB C

POPOR - x 205 0 SE SUPPLY s, ATUNCI CÂND SE OCOLEȘTE NUMAI


**CÂND OCOLIȚI UN AMESTEC DE AER EXTERIOR ȘI RETUR, U l/ AERUL DE RETUR;
ABUR kg/oră x 2310 0 UTILIZAȚI L/S DEZUMIDIFICAT.

ELECTROCASNICE ETC. 0 NOTE

CÂȘTIGURI SUPLIMENTARE DE CĂLDURĂ 0

VAPORI TRANS. MP x 0.01 x - g/kg x 0

SUBTOTAL 0

FACTOR DE SIGURANȚĂ 10 % 0

CĂLDURA LATENTĂ A CAMEREI (RLH) = 0

PIERDEREA SCURGERILOR DIN CONDUCTA DE ALIMENTARE 15 % 0

AER EXTERIOR 1,460.01 l/s x - g/kg x 0.15 BF x 3 0


CĂLDURĂ LATENTĂ EFECTIVĂ ÎN 0
CAMERĂ (ERLH) =
CĂLDURĂ TOTALĂ EFECTIVĂ ÎN ÎNCĂPERE (ERTH) = 0

CĂLDURA AERULUI EXTERIOR

SENSIBIL 1,460.01 l/s X - Cx (1- 0.15 BF) x 1.2 0

LATENTĂ 1,460.01 l/s X - g/kg x (1- 0.15 BF) x 3 0


RESTITUI VERIFICAȚI RES
CÂȘTIG DE CĂLDURĂ PRIN CONDUCTA DE RETUR % RSH + 0 FIGU
BTU / ORĂ / SQ. FT = TAL
CONDUCTĂ - GRAND
RM SENS.
% RSH SQ. FT/PERSOANĂ = T=
RETUR AER SAU SUFLARE - VENTILATOR PRIN Kw. x 1000 0 WATT/MP. F
VENT. AER CFM/MP. FT CFM/MP. FT
MAREA CĂLDURĂ TOTALĂ (GTH) SAU SARCINA 0 AER
DEZUMIDIFICATORULUI = SCHIMBAREA TOTALĂ A TOTAL IDE AIR
AERULUI MIN. OUT GE MIN.
CĂLDURA CONDUCTELOR CHAN
0
UMP H.P. % GTH + % GTH

SARCINA DE REFRIGERARE = 0 ESTIMAREA ÎNCĂRCĂRII AERULUI CONDIȚIONAT FORMULARUL E -