Sunteți pe pagina 1din 1

SC INELCO MON IMPEX SRL

PRODUCATOR

BREVIAR DE CALCUL
Varinta 1

Racord aerian 20 kV tip OL-AL 3x1x50/8 mmp, L = 6 m, si subteran 20 kV tip A2XS(FL)2Y


3x1x150/25 mmp, L = 50 m, in LEA 20 kV Patroaia – Teiu, Stalpul 206

1. CARACTERISTICILE ELECTRICE ALE PRODUCATORULUI DE ENERGIE


ELECTRICA
P inst = 999.0 kW
P max = 999.0 kW
E = 1138860.0 kWh/an
U = 20.0 kV
Cos phi = 1.0

2. CALCULUL TIMPULUI DE UTILIZARE


T = 1138860.0 : 999.0 = 1140 ore/an
T pierderi = 1140 x (10000 + 1140) : (27500 - 1140) = 481 ore/an

3. CALCULUL PUTERII SI AL CURENTILOR


Pc = Pmax = 999.0 kW
S max = 999.0 : 1.0 = 999.0 kVA
I max = 999.0 : (1.73 x 20.0 x 1.0) = 28.87 A

4. CALCULUL SECTIUNII CONDUCTOARELOR


j ec = 1.83 A/mmp
S ec = 28.87:1.83 = 15.78 mmp
DeltaU = 0.55 V  00028 %
Se alege LEC din Al cu sectiunea S = 150.0 mmp de lungime 50.0 m

5. CALCULUL PIERDERILOR DE PUTERE SI ENERGIE PE LINIA DE RACORD


P linie = 26.0 W
DeltaE = 0.026 x 481 = 12.506 kWh/an
CPT = 12.506 : 1138860.0 x 100 = 0.0011 %

Proiectant,