Documente Academic
Documente Profesional
Documente Cultură
- Facultatea de Energetic -
tax
2
tax
1
d2/d2
A
d3/d4
ta``
ta`
tg`
Sectiunea A-A
drumul
drumul
Gaze de
ardere
INTRODUCERE:
TEMA PROIECTULUI:
Sa se proiecteze un recuperator de caldura tip clepsidra unde se cunosc datele de intrare.
n=
ngrupa =
15
7
DATE DE INTRARE:
a)
DaN
340+9n
475
Nm3/h
b)
DgN
300+10n
450
Nm3/h
c)
t'a
15+(ngrupa/2)
18.5
d)
t''a
200-(ngrupa/2)+2n
226.5
e)
t'g
900-2n
870
f)
rCO2
4+(n/5)
rO2
8-n/10
6.5
rH2O
13-n/10
11.5
rCO
n/20
0.75
rN2
75-n/20
74.25
g)
C
C
C
0.97
0.97
15
15
m/s
10
10
m/s
0.8
0.8
m/s
N
a1
N
a2
j)
k)
de
0.04
0.04
l)
0.5
0.5
mm
m)
40
40
W/m*K
n)
de-2dp
o)
0.005
0.039
0.005
h)
i)
N
g
di
ETAPA 1
PROPRIETATILE TERMOFIZICE SI TERMODINAMICE ALE AERULUI SI ALE GAZELOR DE ARDERE
PROPRIETATI AER:
Temperatura
cam
a106
ia
a104
aa
Prax104
kJ/(Nm3*K)
W/(m*K)
Pa*s
Kg/m3
kJ/Nm3
m2/s
m2/s
[-]
t'a
18.5
1.297555
0.0258945
18.0695
t''a
226.5
1.30965
0.04113525
26.9805
ta
122.5
1.301575
0.03377875
22.8225
tax,I
122.5
1.301575
0.03377875
22.8225
tax,II
163.3333333333
1.3044333333
0.0366983333
ta1,I
70.5
1.299115
0.0298985
20.5135
1.027581318
ta1,II
90.9166666667
1.2997275
0.0314705833
21.473083333
0.9699551
ta2,I
174.5
1.305215
0.03749675
24.9545
ta2,II
194.9166666667
1.3066441667
0.0389565417
25.791583333 0.754440222
611.59658
122.5
In calculul ulterior este necesara determinarea temperaturii aerului la iesirea din prima treapta de preincalzire. Se initializeaza cu 2 valori
arbitrare aceasta temperatura :
CAZUL I (pentru prima valoare arbitrara) :
Temperatura aerului la iesirea din prima treapta de preincalzire :
tax,I
(t'a+t''a)/2
=
=
122.5
Temperatura medie a aerului pe primul drum :
ta1,I
(t'a+tax,I)/2
=
=
70.5
Temperatura medie a aerului pe al 2-lea drum :
ta2,I
(tax,I+t''a)/2
174.5
cam
kJ/(Nm3*K)
1.297
1.3
1.307
1.317
226.5
300
18.5
226.5
cam
kJ/(Nm3*K)
1.297
cam
1.3
cam
kJ/(Nm3*K)
1.307
cam
1.317
122.5
200
163.3333333333
200
70.5
100
122.5
163.33333
70.5
1.307
C
cam
kJ/(Nm3*K)
1.3
cam
1.307
C
cam
kJ/(Nm3*K)
1.3
cam
1.307
kJ/(Nm3*K)
1.3
cam
122.5
cam
cam
kJ/(Nm3*K)
1.297
cam
1.3
174.5
200
194.9166666667
200
174.5
194.91667
1.3
C
cam
kJ/(Nm3*K)
1.3
cam
1.307
cam
kJ/(Nm3*K)
1.3
cam
1.307
kJ/(Nm3*K)
1.297
cam
90.916667
cam
a
W/(m*K)
0.02447
0.03217
0.03932
0.04617
226.5
300
122.5
200
122.5
200
226.5
122.5
122.5
0.02447
a
0.03217
C
a
W/(m*K)
0.03932
a
0.04617
C
a
W/(m*K)
0.03217
a
0.03932
W/(m*K)
18.5
a
W/(m*K)
0.03217
a
0.03932
70.5
100
90.9166666667
100
174.5
200
70.5
90.916667
174.5
0.03217
a
0.03932
C
a
W/(m*K)
0.02447
a
0.03217
C
a
W/(m*K)
0.02447
a
0.03217
W/(m*K)
163.33333
a
W/(m*K)
0.03217
a
0.03932
194.91667
18.5
226.5
a
W/(m*K)
0.03217
a
0.03932
a106
Pa*s
17.2
21.9
26
29.7
a106
Pa*s
17.2
106
21.9
a106
Pa*s
26
226.5
300
106
29.7
122.5
200
163.3333333333
200
122.5
163.33333
70.5
Pa*s
26
C
a106
Pa*s
21.9
106
26
C
a106
Pa*s
21.9
106
26
21.9
106
122.5
a106
a106
Pa*s
0
70.5
100
17.2
106
21.9
174.5
200
194.9166666667
200
174.5
194.91667
17.2
106
21.9
C
a106
Pa*s
21.9
106
26
a106
Pa*s
21.9
106
26
Pa*s
90.916667
a106
aN
K
273.15
Kg/Nm3
1.2928
1.2107948568
0.706751366
0.8925270315
0.8925270315
0.8090304784
1.0275813182
0.9699550998
0.7888491455
0.7544402222
18.5
226.5
122.5
122.5
163.33333
70.5
90.916667
174.5
194.91667
18.5
226.5
Kg/m3
Kg/m3
Kg/m3
Kg/m
Kg/m
Kg/m3
Kg/m3
Kg/m3
Kg/m3
378.43191575
kJ/Nm3
ia
cam*(t''a+273,15)
654.3666225
514.96814875
514.96814875
569.3634094444
446.44086975
473.1874585
584.27949475
611.5965796111
kJ/Nm3
kJ/Nm
kJ/Nm
kJ/Nm
122.5
122.5
163.33333
70.5
90.916667
174.5
194.91667
18.5
226.5
122.5
122.5
kJ/Nm3
kJ/Nm3
kJ/Nm3
kJ/Nm
m2/s
m /s
2
m2/s
a104
(a*106)*10-2/a
0.255706541
m2/s
163.33333
70.5
90.916667
174.5
194.91667
18.5
226.5
122.5
122.5
163.33333
70.5
m2/s
m2/s
m2/s
m /s
2
m2/s
m /s
2
m2/s
m2/s
m2/s
m /s
2
aa
[a(a*cam)]*aN
0.0289545585
m2/s
90.916667
174.5
194.91667
18.5
226.5
122.5
122.5
163.33333
70.5
90.916667
174.5
m /s
2
m /s
2
m /s
2
7.0037887434
6.6444609973
6.8023268585
[-]
[-]
[-]
[-]
[-]
[-]
[-]
Prax104
(a*104)/aa
6.7190203756
[-]
194.91667
[-]
cgm
g106
ig
g104
ag
Prgx104
kJ/(Nm3*K)
W/(m*K)
Pa*s
Kg/m3
kJ/Nm3
m2/s
m2/s
[-]
1.47596225
0.07658855
t'g
870
t'g
870
cgm
kJ/(Nm *K)
1.372
cgm
3
N2
1.385
cgm
kJ/(Nm3*K)
1.45
cgm
1.465
cgm
O2
cgm
t
o
C
kJ/(Nm3*K)
600
700
800
1.345
1.359
1.372
900
1000
1.385
1.397
t
o
C
cgm
kJ/(Nm3*K)
600
700
800
1.417
1.434
1.45
900
1000
1.465
1.478
t
o
C
cgm
kJ/(Nm3*K)
600
1.357
C
800
o
870
900
CO
kJ/(Nm3*K)
1.386
cgm
1.4
cgm
CO2
kJ/(Nm3*K)
2.131
cgm
2.169
(cgmi*ri)
cgm
H2 O
kJ/(Nm3*K)
1.67
cgm
1.695
1.47596225
t'g
870
870
g
W/(m*K)
0.0675
g
1.372
1.386
900
1000
1.4
1.413
t
o
C
cgm
kJ/(Nm3*K)
600
700
800
2.041
2.088
2.131
900
1000
2.169
2.204
t
o
C
cgm
kJ/(Nm3*K)
600
700
800
1.61
1.64
1.67
900
1000
1.695
1.72
kJ/(Nm3*K)
t
o
C
800
700
800
N2
t
o
C
W/(m*K)
600
700
800
0.0604
0.0642
0.0675
900
0.0701
900
0.0701
g
W/(m*K)
O2
0.0777
g
0.082
g
W/(m*K)
CO
0.0701
g
0.0755
g
W/(m*K)
CO2
0.0751
g
0.0809
g
W/(m*K)
0.11
H2 O
1000
0.0723
t
o
C
g
W/(m*K)
600
700
800
0.0674
0.0728
0.0777
900
1000
0.082
0.0858
t
o
C
g
W/(m*K)
600
700
800
0.0597
0.065
0.0701
900
1000
0.0755
0.0806
t
o
C
g
W/(m*K)
600
700
800
0.0621
0.0688
0.0751
900
1000
0.0809
0.0866
t
o
C
g
W/(m*K)
600
700
800
0.0818
0.0956
0.11
870
900
0.124
(gi*ri)
900
1000
0.07658855
W/(m*K)
t'g
870
Pa*s
g10
N2
Pa*s
42.3
g106
45
Pa*s
g10
O2
Pa*s
50.2
g106
53.4
Pa*s
g10
Pa*s
43.2
g106
46
0.124
0.141
CO
t
o
C
g106
600
700
800
36.9
39.6
42.3
900
1000
45
47.5
t
o
C
g106
600
700
800
43.5
47
50.2
900
1000
53.4
56.5
t
o
C
g106
600
700
800
37.4
40.4
43.2
900
1000
46
48.7
Pa*s
Pa*s
Pa*s
1/(ri/gi)
Pa*s
g10
CO2
Pa*s
44.6
g106
48.1
Pa*s
g10
H2 O
Pa*s
42.6
g106
47.5
45.0568540509
g106
600
700
800
37.7
41.1
44.6
900
1000
48.1
51.5
t
o
C
g106
600
700
800
33.1
37.9
42.6
900
1000
47.5
52.4
Pa*s
t'g
t
o
C
1.26139975
Kg/Nm3
t(0C) = 0
gN
N2
O2
CO
CO2
H2O
1.2505
1.4289
1.25
1.9748
0.8036
T0
273.15
Tg
1143.15
gN*(T0/Tg)
0.3014051889
Kg/m3
870
Pa*s
Pa*s
cgm*(t'g+273,15)
1687.246246088
(g*106)*10-2/g
1.4948931109
[g(g*cgm)]*gN
0.2171653906
(g*104)/ag
6.883661835
t'g
870
t'g
870
t'g
870
m2/s
870
m2/s
kJ/Nm3
t'g
[-]
ETAPA 2
DETERMINAREA TEMPERATURII GAZELOR DE ARDERE LA IESIREA DIN RECUPERATOR SI
A PROPRIETATIILOR SALE, CAT SI A TEMPERATURII MEDII
Din ecuatia bilantului termic pe recuperator se v-a determina entalpia gazelor de ardere la iesire:
Qa = r*Qg <=> (DaN/3600)*(i''a- i'a) = r*(DgN/3600)*(i'g- i''g) =>
cgm
kJ/(Nm *K)
1.385
cgm
3
N2
1.397
cgm
kJ/(Nm3*K)
1.465
cgm
1.478
O2
cgm
t
o
C
kJ/(Nm3*K)
600
700
800
1.345
1.359
1.372
900
1000
1.385
1.397
t
o
C
cgm
kJ/(Nm3*K)
600
700
800
1.417
1.434
1.45
900
1000
1.465
1.478
cgm
kJ/(Nm3*K)
600
700
800
1.357
1.372
1.386
900
1000
1.4
1.413
t
o
C
cgm
kJ/(Nm3*K)
600
700
800
2.041
2.088
2.131
900
1000
2.169
2.204
t
o
C
cgm
kJ/(Nm3*K)
600
700
800
1.61
1.64
1.67
900
1000
1.695
1.72
t
o
C
900
939.7080824
1000
cgm
CO
kJ/(Nm *K)
1.4
cgm
3
1.413
cgm
CO2
kJ/(Nm3*K)
2.169
cgm
2.204
cgm
H2 O
kJ/(Nm3*K)
1.695
cgm
1.72
(cgmi*ri)
1.4868691942
kJ/(Nm3*K)
c''gm**t''g
1397.22299933
kJ/Nm3
0.0073897176
|(i''g-i''g*)/ i''g|
<
OBS:
In cazul in care eroarea admisibila relativa a entalpiei era mai mare decat 1%, am fi aplicat un calcul iterativ pana ce aceasta devenea
mai mica decat 1%
=>
t''g
939.70808244
Se vor calcula proprietatiile gazelor de ardere pentru temperatura la iesirea din recuperator si temperatura medie:
cgm
g
g106
g
ig
g104
Temperatura
C
kJ/(Nm3*K)
W/(m*K)
Pa*s
ag
Prgx104
Kg/m3
kJ/Nm3
m2/s
m2/s
[-]
6.976832315
t''g
0.2840821583
1397.223
1.6577424708
0.237607
tg
0.2924874021
1745.3686
1.5764603026
0.227259 6.9368536784
t''g
939.70808244
g
W/(m*K)
N2
0.0701
g
0.0723
g
W/(m*K)
0.082
g
0.0858
O2
t
o
C
W/(m*K)
600
700
800
0.0604
0.0642
0.0675
900
1000
0.0701
0.0723
t
o
C
g
W/(m*K)
600
700
800
0.0674
0.0728
0.0777
900
1000
0.082
0.0858
t
o
C
g
W/(m*K)
t
o
C
900
939.7080824
1000
g
CO
W/(m*K)
0.0755
g
0.0806
g
CO2
W/(m*K)
0.0809
g
0.0866
(gi*ri)
g
H2 O
W/(m*K)
0.124
g
0.141
0.0795651271
600
700
800
0.0597
0.065
0.0701
900
1000
0.0755
0.0806
t
o
C
g
W/(m*K)
600
700
800
0.0621
0.0688
0.0751
900
1000
0.0809
0.0866
t
o
C
g
W/(m*K)
600
700
800
0.0818
0.0956
0.11
900
1000
0.124
0.141
W/(m*K)
t''g
939.70808244
g106
Pa*s
600
700
800
36.9
39.6
42.3
Pa*s
o
t
o
C
900
g10
Pa*s
45
N2
939.7080824
1000
Viscozitatea dinamica pentru O2:
g106
=
54.6309505555
g106
47.5
900
1000
45
47.5
Pa*s
g106
Pa*s
600
700
800
43.5
47
50.2
900
1000
53.4
56.5
t
o
C
g106
600
700
800
37.4
40.4
43.2
900
1000
46
48.7
t
o
C
g106
600
700
800
37.7
41.1
44.6
900
1000
48.1
51.5
t
o
C
g106
600
33.1
t
o
C
900
939.7080824
1000
g10
O2
Pa*s
53.4
g106
56.5
g10
CO
Pa*s
46
g106
48.7
g10
CO2
Pa*s
48.1
g106
51.5
g10
Pa*s
Pa*s
Pa*s
C
900
o
939.7080824
1000
g106
1/(ri/gi)
H2 O
Pa*s
47.5
g106
52.4
47.0935058928
t''g
1.26139975
Kg/Nm3
t''g
939.70808244
t''g
939.70808244
t''g
939.70808244
N2
O2
CO
CO2
H2O
1.2505
1.4289
1.25
1.9748
0.8036
T0
273.15
Tg
1212.858082436
gN*(T0/Tg)
0.2840821583
Kg/m3
1.6577424708
[g(g*cgm)]*gN
0.2376067527
(g*104)/ag
6.976832315
tg
(t'g+t''g)/2
904.8540412
m2/s
m2/s
47.5
52.4
939.70808244
900
1000
t(0C) = 0
gN
g104
37.9
42.6
Pa*s
700
800
[-]
tg
904.85404122
cgm
kJ/(Nm3*K)
1.372
cgm
N2
1.385
cgm
kJ/(Nm3*K)
1.45
cgm
O2
1.465
cgm
kJ/(Nm *K)
1.386
cgm
3
CO
1.4
cgm
kJ/(Nm *K)
2.131
3
CO2
cgm
t
o
C
kJ/(Nm3*K)
600
700
800
1.345
1.359
1.372
900
1000
1.385
1.397
t
o
C
cgm
kJ/(Nm3*K)
600
700
800
1.417
1.434
1.45
900
1000
1.465
1.478
t
o
C
cgm
kJ/(Nm3*K)
600
700
800
1.357
1.372
1.386
900
1000
1.4
1.413
t
o
C
cgm
kJ/(Nm3*K)
600
700
800
2.041
2.088
2.131
904.8540412
900
cgm
2.169
900
1000
2.169
2.204
cgm
kJ/(Nm3*K)
600
700
800
1.61
1.64
1.67
900
1000
1.695
1.72
t
o
C
800
904.8540412
900
cgm
cgm
H2 O
kJ/(Nm *K)
1.67
cgm
3
1.695
(cgmi*ri)
1.4816321312
kJ/(Nm3*K)
tg
904.85404122
g
W/(m*K)
N2
0.0675
g
0.0701
g
W/(m*K)
0.0777
g
0.082
O2
t
o
C
W/(m*K)
600
700
800
0.0604
0.0642
0.0675
900
1000
0.0701
0.0723
t
o
C
g
W/(m*K)
600
700
800
0.0674
0.0728
0.0777
900
1000
0.082
0.0858
0.0757621182
t
o
C
800
904.8540412
900
W/(m*K)
g
CO
W/(m*K)
0.0701
g
0.0755
g
CO2
W/(m*K)
0.0751
g
0.0809
g
H2 O
W/(m*K)
0.11
g
904.8540412
900
0.124
(gi*ri)
0.0780755977
Pa*s
g10
t
o
C
W/(m*K)
600
700
800
0.0597
0.065
0.0701
900
1000
0.0755
0.0806
t
o
C
g
W/(m*K)
600
700
800
0.0621
0.0688
0.0751
900
1000
0.0809
0.0866
t
o
C
g
W/(m*K)
600
700
800
0.0818
0.0956
0.11
900
1000
0.124
0.141
W/(m*K)
tg
904.85404122
t
o
C
g106
600
36.9
Pa*s
C
800
o
904.8540412
900
Viscozitatea dinamica pentru O2:
g106
=
53.555329319
t
o
C
800
904.8540412
900
Pa*s
N2
42.3
g106
45
Pa*s
g106
Pa*s
O2
50.2
g106
53.4
g106
Pa*s
CO
43.2
g106
46
g106
Pa*s
44.6
g106
48.1
CO2
700
800
39.6
42.3
900
1000
45
47.5
t
o
C
g106
600
700
800
43.5
47
50.2
900
1000
53.4
56.5
t
o
C
g106
600
700
800
37.4
40.4
43.2
900
1000
46
48.7
t
o
C
g106
600
700
800
37.7
41.1
44.6
900
1000
48.1
51.5
g106
Pa*s
Pa*s
Pa*s
Pa*s
600
700
800
33.1
37.9
42.6
900
1000
47.5
52.4
t
o
C
800
904.8540412
900
g106
1/(ri/gi)
g10
H2 O
Pa*s
42.6
g106
47.5
46.1094778455
Pa*s
tg
1.26139975
Kg/Nm3
904.85404122
tg
904.85404122
tg
904.85404122
tg
904.85404122
t(0C) = 0
gN
N2
O2
CO
CO2
H2O
1.2505
1.4289
1.25
1.9748
0.8036
T0
273.15
Tg
1178.004041218
gN*(T0/Tg)
0.2924874021
Kg/m3
cgm*(tg+273,15)
1745.3686381
(g*106)*10-2/g
1.5764603026
[g(g*cgm)]gN
0.2272586933
m2/s
kJ/Nm3
m2/s
tg
(g*104)/ag
6.9368536784
[-]
904.85404122
ETAPA 3
DETERMINAREA NUMARULUI DE TEVI SI A DIAMETRELOR SECTIUNII
TRANSVERSALE A RECUPERATORULUI
d4
d3
d2
d1
C
a
n
a
l
g
a
z
e
C
a
n
a
l
i
n
c
l
a
r
nt
buc
Wa1,I
m/s
17.3698940669
Wa1,II
m/s
18.4018607109
d1
0.47
d2
0.48
Wg
m/s
3.2983263697
d3
0.5
d4
0.51
Wa2,I
m/s
14.0469662872
Wa2,II
m/s
14.6876280282
Prin rotunjirea numarului de tevi creste sectiunea de curgere a aerului si scade viteza w
wa1N
4*DaN/(3600**di2*nt)
=>
8
N
. Prin urmare vom recalcula wa1 :
7.363440034
N
a1
13.806450064
m/s
wa1N*(Ta1,I/To)
17.3698940669
m/s
wa1 *(Ta1,II/To)
18.4018607109
m/s
tevi
buc
0.4601561462
0.48
0.47
0.5
d1+2
Prin rotunjirea lui d1 creste sectiunea de curgere si scade viteza w . Prin urmare se recalculeaza wgN :
N
g
wgN
4*DgN/[3600**(d12-nt*de2)]
0.7648003032
m/s
3.2983263697
m/s
wgN*(Tg/To)
X Determinarea diametrelor virolei exterioare si vitezele aerului in conditii normale pe al 2-lea drum:
Diametrul d3 se determina din ecuatia de continuitate pentru aer in canalul inelar:
DaN/3600 = wa2N*(/4)*(d32-d22) => d3 = [d22+4*DaN/(3600**wa2N)]
0.4971918025
0.51
d3+2
Prin rotunjirea lui d3 creste sectiunea de curgere si scade viteza wa2N. Prin urmare se recalculeaza wa2N :
wa2N
4*DaN/[3600**(d32-d22)]
8.571269611
m/s
Viteza aerului in conditii normale prin tevi, pe cel de-al 2-lea drum:
wa2,I
wa2,II
wa2N*(Ta2,I/To)
14.0469662872
m/s
wa2 *(Ta2,II/To)
14.6876280282
m/s
ETAPA 4
CALCULUL COEFICIENTILOR DE CONVECTIE PENTRU AER SI GAZE DE ARDERE
evi
Canalul inelar
tg, g1
tg, g2
tp1
tp2
ta1, a1
ta, a2
di
d1
de
d2
daech,1
0.039
daech,2
0.02
Rea1,I
33934.2465717876
Rea2,I
8880.91314436
Rea1,II
32417.8021499954
Rea2,II
8592.6770837101
a1,I
W/(m2*K)
4.6882339054
a2,I
W/(m2*K)
2.3994282234
a1,II
W/(m *K)
4.7479106085
a2,II
W/(m *K)
2.4233980588
0.263
dgech
0.263
5502.5796324218
Reg
5502.5796324218
0.2410931283
cg
W/(m *K)
0.2410931283
34.0723185558
rg2,I
W/(m *K)
25.6556427602
Reg
cg
W/(m *K)
rg1,I
W/(m *K)
rg1,II
W/(m *K)
35.0251461468
rg2,II
W/(m *K)
24.4959265835
g1,I
W/(m2*K)
34.3134116841
g2,I
W/(m2*K)
25.8967358885
g1,II
W/(m2*K)
35.2662392751
g2,II
W/(m2*K)
24.7370197118
487.677020609
tp2,I
539.677020609
497.8853539423
tp2,II
549.8853539423
di
0.039
d3-d2
0.02
wa1,I*daech1/a1,I
33934.2465717876
wa1,II*d
/a1,II
32417.8021499954
wa2,I*daech2/a2,I
8880.91314436
wa2,II*daech2/a2,II
8592.6770837101
=>
=>
a1,I
0,0267*(a1,I/daech1)*Rea1,I0,8*Pra1,I0,4
4.6882339054
W/(m2*K)
a1,II
0,0267*(a1,II/daech1)*Rea1,II0,8*Pra1,II0,4
4.7479106085
W/(m2*K)
2
2
2
tp1,I
tp1,II
2
2
2
AER:
Diametrul echivalent:
X Pentru tevi:
daech,1
Numarul Reynolds:
X Pentru tevi:
Rea1,I
Rea1,II
a
ech1
Coeficientul de convectie:
X Pentru tevi:
Rea1,I>104
Rea1,II>104
2320< Rea2,I<104
a2,I
=>
k
2320< Rea2,II<10
a2,II
=>
(a2,I/daech2)*k*Pra2,I0,43
-0,192*10 *Re
(a2,II/d
-6
-0,192*10 *Re
-6
+6,04*10 *Rea2,I-8,89
2
a2,I
-3
)*k*Pra2,II0,43
a
ech2
+6,04*10 *Rea2,II-8,89
2
a2,II
-3
2.3994282234
W/(m2*K)
29.6075566826
2.4233980588
W/(m2*K)
28.8336224883
GAZE DE ARDERE:
Transferul de caldura pe partea gazelor se realizeaza prin convectie si radiatie (g = cg+rg):
Convectie:
X Diametrul echivalent:
=
4*S/P
[4*(/4)*(d12-nt*de2)]/[*(d1+nt*de)]
(d12-nt*de2)/(d1+nt*de)
0.2634177215
0.263
wg*dgech/g
5502.5796324218
=>
cg
(g/dgech)*k*Prg0,43
0.2410931283
W/(m2*K)
18.5321315185
tp=(ta+tg)/2
=>
(ta1,I+tg)/2
q +q
487.677020609
1,15*qrg1
=>
c0
5.67
W/(m2*K)
=
=
0.79
CO2+*H2O
0.11276
din grafic
pCO2
dgech
X Numarul Reynolds:
Reg
X Coeficientul de convectie:
2320< Reg<104
Radiatie:
Presupunem initial ca:
TEVI:
tp1,I
r
g
r
g
r
g1
r
g2
2
g
-3
=
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp/100)4]
-6
CO2
f(tg, pCO2*l)
=
=
Factorul de emisie pentru vaporii de apa:
H2O
=
f(tg, pH2O*l)
Presiunea atmosferica:
patm
din grafic
pH2O
=
=
=
0.062
(rCO2/100)*patm
0.07
7
bar
kPa
0.047
(rH2O/100)*patm
0.115
11.5
=
bar
kPa
bar
l
tg
=
=
1.6569
kPa*m
2.72205
f(pH2O, pH2O*l)
=
=
0.2367
904.8540412179
kPa*m
0.0272205
m*bar
din grafic
Agp
=
f(tp, pCO2*l)
=
Presiunea partiala pentru CO2:
f(tp, pH2O*l)
din grafic
pCO2
=
=
=
=
pH2O
patm
l
tp
Tp
Tg
=
=
=
=
1.6569
kPa*m
2.72205
kPa*m
f(pH2O, pH2O*l)
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
pCO2*l
=
pH2O*l
0,9*dgech
din grafic
=
=
=
0,9*dgech
=
=
1.08
*(Tg/Tp)0,65+*H2Op
p
CO2
0.06
(rCO2/100)*patm
0.07
7
0.1553188095
m
C
0.07
(rH2O/100)*patm
0.115
11.5
1
=
bar
kPa
=
bar
kPa
bar
=
=
=
=
0.2367
487.677020609
760.827020609
1178.0040412179
m
C
K
K
0.0272205
m*bar
1.08
9634.8398050853
W/m2
Coeficientul de corectie:
qrg
=
din grafic
4
1,15*c0*[(1+p)/2]*[g*(Tg/100) -Agp*(Tp/100)4]
r
g
q /(tg-tp)
23.0953272331
W/(m2*K)
cg+rg
23.3364203614
W/(m2*K)
CO2p*(Tg/Tp*)0,65+*H2Op
0.1245366098
r
g
|tp-tp*|
277.5982458658
Se reiau calculele:
- Agentul termic al peretelui
Factorul de emisie pentru CO2:
CO2p
f(tp*, pCO2*l)
(ta*a+tg*g)/(a+g)
=
=
(ta1,I*a1,I+tg*g)/(a1,I+g)
>
=>
Agp
=
=
=
pCO2
din grafic
765.2752664748
=
C
0.062
(rCO2/100)*patm
=
=
Factorul de emisie pentru vaporii de apa:
H2Op
=
f(tp*, pH2O*l)
=
pH2O
Presiunea atmosferica:
patm
l
tp*
Tp*
Tg
=
=
=
=
1.6569
kPa*m
2.72205
kPa*m
f(pH2O, pH2O*l)
pH2O*l
din grafic
=
=
=
0,9*dgech
0.07
7
=
bar
kPa
0.053
(rH2O/100)*patm
0.115
11.5
=
bar
kPa
bar
=
=
=
=
0.2367
765.2752664748
1038.4252664748
1178.0040412179
0.0272205
m*bar
1.08
4221.1474868424
W/m2
*
p
m
C
K
K
Coeficientul de corectie:
qrg
=
din grafic
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp*/100)4]
r
g
q /(tg-t )
30.2420442837
W/(m2*K)
cg+rg
30.4831374119
W/(m2*K)
CO2p*(Tg/Tp**)0,65+*H2Op
r
g
|tp*-tp**|
28.3619879463
Se reiau calculele:
- Agentul termic al peretelui
CO2p
f(tp**, pCO2*l)
f(tp**, pH2O*l)
(ta*a+tg*g)/(a+g)
=
=
(ta1,I*a1,I+tg*g)/(a1,I+g)
>
=>
Agp
=
=
793.637254421
=
pCO2
din grafic
=
pH2O
din grafic
Presiunea atmosferica:
patm
l
tp**
Tp**
=
=
=
=
C
=
=
=
=
=
=
0,9*dgech
-
0.1169284214
0.059
(rCO2/100)*patm
0.07
7
0.05
(rH2O/100)*patm
0.115
11.5
=
=
=
0.2367
793.637254421
1066.787254421
=
bar
kPa
=
bar
kPa
bar
m
C
K
Tg
1.6569
kPa*m
kPa*m
pH2O*l
Coeficientul de corectie:
2.72205
qrg
f(pH2O, pH2O*l)
1178.0040412179
0.0272205
m*bar
1.08
3834.408585932
W/m2
**
p
=
din grafic
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp**/100)4]
r
g
q /(tg-t )
34.4768869553
W/(m2*K)
cg+rg
34.7179800836
W/(m2*K)
CO2p*(Tg/Tp***)0,65+*H2Op
r
g
|tp**-tp***|
11.9520640746
Se reiau calculele:
- Agentul termic al peretelui
CO2p
f(tp***, pCO2*l)
f(tp***, pH2O*l)
(ta*a+tg*g)/(a+g)
=
=
(ta1,I*a1,I+tg*g)/(a1,I+g)
>
=>
Agp
=
=
805.5893184956
=
pCO2
din grafic
din grafic
pH2O
=
=
=
0,9*dgech
patm
l
tp***
Tp***
Tg
=
=
=
=
1.6569
kPa*m
2.72205
kPa*m
qrg
f(pH2O, pH2O*l)
=
=
=
Presiunea atmosferica:
=
C
0.1175543417
0.059
(rCO2/100)*patm
0.07
7
0.051
(rH2O/100)*patm
0.115
11.5
=
bar
kPa
=
bar
kPa
bar
=
=
=
=
0.2367
805.5893184956
1078.7393184956
1178.0040412179
0.0272205
m*bar
1.08
=
din grafic
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp***/100)4]
3382.179253951
W/m2
rg
qrg/(tg-tp***)
34.0723185558
W/(m2*K)
cg+rg
34.3134116841
W/(m2*K)
pH2O*l
m
C
K
K
Coeficientul de corectie:
(ta*a+tg*g)/(a+g)
=
=
(ta1,I*a1,I+tg*g)/(a1,I+g)
804.5596345069
=
C
|tp***-tp****|
1.0296839888
<
tp1,II
(ta1,II+tg)/2
497.8853539423
1,15*qrg1
=>
c0
5.67
0.79
=
=
CO2+*H2O
r
g
r
g
q +q
r
g1
r
g2
=
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp/100)4]
=
=
W/(m2*K)
0.11276
CO2
f(tg, pCO2*l)
=
Presiunea partiala pentru CO2:
=
pCO2
din grafic
=
pH2O
din grafic
=
=
=
0.062
(rCO2/100)*patm
0.07
7
=
bar
kPa
H2O
f(tg, pH2O*l)
=
Presiunea partiala pentru H2O:
patm
l
tg
=
=
1.6569
kPa*m
2.72205
f(pH2O, pH2O*l)
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura gazelor de ardere:
pCO2*l
=
pH2O*l
=
=
=
=
0,9*dgech
0.047
(rH2O/100)*patm
0.115
11.5
=
=
0.2367
904.8540412179
kPa*m
0.0272205
m*bar
din grafic
Agp
1.08
CO2p*(Tg/Tp)0,65+*H2Op
=
bar
kPa
bar
m
C
Coeficientul de corectie:
=
=
f(tp, pCO2*l)
f(tp, pH2O*l)
=
pCO2
din grafic
din grafic
pH2O
=
=
=
=
=
=
=
=
=
0.1585827202
0.063
(rCO2/100)*patm
0.07
7
=
bar
kPa
0.07
(rH2O/100)*patm
0.115
11.5
=
bar
kPa
patm
l
tp
Tp
Tg
=
=
=
=
1.6569
kPa*m
2.72205
kPa*m
f(pH2O, pH2O*l)
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
pCO2*l
=
pH2O*l
0,9*dgech
bar
=
=
=
=
0.2367
497.8853539423
771.0353539423
1178.0040412179
0.0272205
m*bar
1.08
9401.2055595405
W/m2
m
C
K
K
Coeficientul de corectie:
qrg
=
din grafic
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp/100)4]
r
g
q /(tg-tp)
23.1005624105
W/(m2*K)
cg+rg
23.3416555388
W/(m2*K)
CO2p*(Tg/Tp*)0,65+*H2Op
r
g
|tp-tp*|
269.390845204
Se reiau calculele:
- Agentul termic al peretelui
CO2p
f(tp*, pCO2*l)
=
Presiunea partiala pentru CO2:
f(tp*, pH2O*l)
=
=
(ta1,II*a1,II+tg*g)/(a1,II+g)
>
=>
Agp
=
=
767.2761991463
=
pCO2
din grafic
=
pH2O
din grafic
Presiunea atmosferica:
patm
l
tp*
Tp*
Tg
=
=
=
=
1.6569
kPa*m
2.72205
kPa*m
f(pH2O, pH2O*l)
pH2O*l
(ta*a+tg*g)/(a+g)
=
C
=
=
=
=
=
=
0,9*dgech
0.1222843122
0.06
(rCO2/100)*patm
0.07
7
0.053
(rH2O/100)*patm
0.115
11.5
=
=
=
=
0.2367
767.2761991463
1040.4261991463
1178.0040412179
0.0272205
m*bar
1.08
4309.8424532529
=
bar
kPa
=
bar
kPa
bar
m
C
K
K
Coeficientul de corectie:
qrg
=
din grafic
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp*/100)4]
W/m2
rg
g
qrg/(tg-tp*)
31.3265740206
W/(m2*K)
g+
31.5676671489
W/(m2*K)
CO2p*(Tg/Tp**)0,65+*H2Op
0.1178249677
r
g
|tp*-tp**|
31.1634013848
Se reiau calculele:
- Agentul termic al peretelui
CO2p
f(tp**, pCO2*l)
f(tp**, pH2O*l)
(ta*a+tg*g)/(a+g)
=
=
(ta1,II*a1,II+tg*g)/(a1,II+g)
>
=>
Agp
=
=
din grafic
pCO2
=
=
=
798.4396005311
=
pH2O
Presiunea atmosferica:
patm
l
tp**
Tp**
Tg
=
=
=
=
1.6569
kPa*m
pH2O*l
Coeficientul de corectie:
2.72205
kPa*m
qrg
f(pH2O, pH2O*l)
din grafic
=
=
=
0,9*dgech
=
C
0.059
(rCO2/100)*patm
0.07
7
0.051
(rH2O/100)*patm
0.115
11.5
1
=
bar
kPa
=
bar
kPa
bar
=
=
=
=
0.2367
798.4396005311
1071.5896005311
1178.0040412179
m
C
K
K
0.0272205
m*bar
1.08
3605.2031528675
W/m2
**
p
=
din grafic
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp**/100)4]
r
g
q /(tg-t )
33.8788902107
W/(m2*K)
cg+rg
34.119983339
W/(m2*K)
CO2p*(Tg/Tp***)0,65+*H2Op
r
g
|tp**-tp***|
Se reiau calculele:
- Agentul termic al peretelui
6.9878573867
(ta*a+tg*g)/(a+g)
=
=
(ta1,II*a1,II+tg*g)/(a1,II+g)
>
=>
Agp
=
=
805.4274579178
=
C
0.1164804355
CO2p
f(tp***, pCO2*l)
f(tp***, pH2O*l)
din grafic
pCO2
=
=
=
=
pH2O
Presiunea atmosferica:
patm
l
tp***
Tp***
Tg
=
=
=
=
1.6569
kPa*m
kPa*m
pH2O*l
Coeficientul de corectie:
2.72205
qrg
f(pH2O, pH2O*l)
=
=
=
0,9*dgech
q /(tg-t
r
g
2.6082169983
Se reiau calculele:
- Agentul termic al peretelui
CO2p
f(tp****, pCO2*l)
f(tp****, pH2O*l)
Presiunea atmosferica:
Grosimea medie a stratului radiat:
0.07
7
=
0.0272205
m*bar
1.08
3472.5691950512
W/m2
34.9259632564
W/(m2*K)
35.1670563847
W/(m2*K)
CO2p*(Tg/Tp***)0,65+*H2Op
(ta*a+tg*g)/(a+g)
>
=>
Agp
=
=
din grafic
pCO2
=
=
=
808.0356749161
din grafic
=
=
=
0,9*dgech
m
C
K
K
=
=
patm
=
bar
kPa
bar
0.2367
805.4274579178
1078.5774579178
1178.0040412179
(ta1,II*a1,II+tg*g)/(a1,II+g)
=
pH2O
0.05
(rH2O/100)*patm
0.115
11.5
1
=
bar
kPa
=
=
=
=
cg+rg
|tp***-tp****|
***
p
0.059
(rCO2/100)*patm
=
din grafic
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp***/100)4]
r
g
din grafic
=
C
0.1163824224
0.059
(rCO2/100)*patm
0.07
7
=
=
0.05
(rH2O/100)*patm
0.115
11.5
1
0.2367
=
bar
kPa
=
bar
kPa
bar
m
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
pCO2*l
=
tp****
Tp****
Tg
=
=
=
1.6569
kPa*m
kPa*m
pH2O*l
Coeficientul de corectie:
2.72205
qrg
f(pH2O, pH2O*l)
q /(tg-t
g+
r
g
|tp****-tp*****|
=
=
=
808.0356749161
1081.1856749161
1178.0040412179
0.0272205
m*bar
1.08
3391.0774294154
W/m2
35.0251461468
W/(m2*K)
35.2662392751
W/(m2*K)
W/(m2*K)
=
din grafic
4
1,15*c0*[(1+p)/2]*[g*(Tg/100) -Agp*(Tp****/100)4]
r
g
****
p
r
g
(ta*a+tg*g)/(a+g)
=
=
(ta1,II*a1,II+tg*g)/(a1,II+g)
808.275658158
C
K
K
=
=
C
0.2399832419
<
(ta2,I+tg)/2
q +q
539.677020609
1,15*qrg2
=>
c0
5.67
0.79
=
=
CO2+*H2O
CANALUL INELAR:
tp2,I
r
g
r
g
r
g1
r
g2
=
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp/100)4]
=
=
0.11276
CO2
f(tg, pCO2*l)
=
pCO2
din grafic
din grafic
pH2O
=
=
=
0,9*dgech
=
=
=
0.062
(rCO2/100)*patm
0.07
7
=
bar
kPa
H2O
f(tg, pH2O*l)
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura gazelor de ardere:
pCO2*l
=
pH2O*l
=
patm
l
tg
=
=
1.6569
kPa*m
2.72205
kPa*m
0.047
(rH2O/100)*patm
0.115
11.5
=
=
0.2367
904.8540412179
0.0272205
m*bar
=
bar
kPa
bar
m
C
Coeficientul de corectie:
f(pH2O, pH2O*l)
din grafic
Agp
=
f(tp, pCO2*l)
=
pCO2
f(tp, pH2O*l)
pH2O
=
=
=
0,9*dgech
l
tp
Tp
Tg
=
=
=
=
1.6569
kPa*m
2.72205
kPa*m
f(pH2O, pH2O*l)
=
=
=
=
=
=
=
din grafic
din grafic
patm
Presiunea atmosferica:
pH2O*l
1.08
CO2p*(Tg/Tp)0,65+*H2Op
0.066
(rCO2/100)*patm
0.07
7
0.15744218
0.068
(rH2O/100)*patm
0.115
11.5
1
=
bar
kPa
=
bar
kPa
bar
=
=
=
=
0.2367
539.677020609
812.827020609
1178.0040412179
m
C
K
K
0.0272205
m*bar
1.08
8661.352169957
W/m2
Coeficientul de corectie:
qrg
=
din grafic
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp/100)4]
r
g
q /(tg-tp)
23.7182289168
W/(m2*K)
cg+rg
23.9593220451
W/(m2*K)
CO2p*(Tg/Tp*)0,65+*H2Op
0.1235783198
r
g
|tp-tp*|
298.6931364448
Se reiau calculele:
- Agentul termic al peretelui
CO2p
f(tp*, pCO2*l)
f(tp*, pH2O*l)
(ta*a+tg*g)/(a+g)
=
=
(ta2,I*a2,I+tg*g)/(a2,I+g)
>
=>
Agp
=
=
=
pCO2
din grafic
=
pH2O
838.3701570537
=
C
=
=
=
din grafic
=
0.067
(rCO2/100)*patm
0.07
7
0.05
(rH2O/100)*patm
=
bar
kPa
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
pCO2*l
=
patm
l
tp*
Tp*
Tg
=
=
=
=
1.6569
kPa*m
kPa*m
=
=
0,9*dgech
0.115
11.5
bar
kPa
bar
=
=
=
=
0.2367
838.3701570537
1111.5201570537
1178.0040412179
0.0272205
m*bar
1.08
1663.8462035411
W/m2
m
C
K
K
pH2O*l
Coeficientul de corectie:
2.72205
qrg
f(pH2O, pH2O*l)
=
din grafic
4
1,15*c0*[(1+p)/2]*[g*(Tg/100) -Agp*(Tp*/100)4]
rg
qrg/(tg-tp*)
25.0263086229
W/(m2*K)
cg+rg
25.2674017512
W/(m2*K)
CO2p*(Tg/Tp**)0,65+*H2Op
|tp*-tp**|
3.1433387828
Se reiau calculele:
- Agentul termic al peretelui
CO2p
f(tp**, pCO2*l)
f(tp**, pH2O*l)
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
pCO2*l
=
=
=
(ta2,I*a2,I+tg*g)/(a2,I+g)
>
=>
Agp
=
=
841.5134958365
din grafic
pCO2
=
=
=
=
pH2O
patm
l
t
T
Tg
=
=
=
=
1.6569
kPa*m
**
p
**
p
(ta*a+tg*g)/(a+g)
din grafic
=
=
=
0,9*dgech
=
C
0.1223707202
0.067
(rCO2/100)*patm
0.07
7
0.049
(rH2O/100)*patm
0.115
11.5
1
=
=
=
=
0.2367
841.5134958365
1114.6634958365
1178.0040412179
pH2O*l
Coeficientul de corectie:
2.72205
kPa*m
0.0272205
m*bar
f(pH2O, pH2O*l)
din grafic
1.08
=
bar
kPa
=
bar
kPa
bar
m
C
K
K
qrg
r
g
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp**/100)4]
1647.587291542
W/m2
q /(tg-t )
26.0115741287
W/(m2*K)
g+
26.252667257
W/(m2*K)
CO2p*(Tg/Tp***)0,65+*H2Op
0.1222826507
r
g
**
p
r
g
|tp**-tp***|
2.1781043739
Se reiau calculele:
- Agentul termic al peretelui
CO2p
f(tp***, pCO2*l)
f(tp***, pH2O*l)
pH2O*l
=
=
>
=>
Agp
=
=
din grafic
pCO2
=
=
=
t
T
Tg
=
=
=
=
1.6569
kPa*m
2.72205
kPa*m
f(pH2O, pH2O*l)
***
p
***
p
843.6916002104
=
pH2O
(ta2,I*a2,I+tg*g)/(a2,I+g)
patm
Presiunea atmosferica:
(ta*a+tg*g)/(a+g)
din grafic
=
=
=
0,9*dgech
=
C
0.067
(rCO2/100)*patm
0.07
7
0.049
(rH2O/100)*patm
0.115
11.5
=
=
=
=
0.2367
843.6916002104
1116.8416002104
1178.0040412179
0.0272205
m*bar
=
bar
kPa
=
bar
kPa
bar
m
C
K
K
Coeficientul de corectie:
qrg
r
g
=
din grafic
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp***/100)4]
=
=
q /(tg-t
g+
r
g
***
p
r
g
(ta*a+tg*g)/(a+g)
=
=
(ta2,I*a2,I+tg*g)/(a2,I+g)
842.9222510067
|tp***-tp****|
0.7693492037
<
tp2,II
(ta2,II+tg)/2
549.8853539423
1.08
1569.1617368335
W/m2
25.6556427602
W/(m2*K)
25.8967358885
W/(m2*K)
=
=
C
qrg
r
g
qrg1+qrg2
1,15*qrg2
=
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp/100)4]
c0
5.67
0.79
=
=
CO2+*H2O
0.11276
=
pCO2
din grafic
=>
W/(m2*K)
CO2
f(tg, pCO2*l)
=
Presiunea partiala pentru CO2:
=
=
=
0.062
(rCO2/100)*patm
0.07
7
=
bar
kPa
H2O
f(tg, pH2O*l)
=
Presiunea partiala pentru H2O:
din grafic
pH2O
=
=
=
0,9*dgech
patm
l
tg
=
=
1.6569
kPa*m
2.72205
f(pH2O, pH2O*l)
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura gazelor de ardere:
pCO2*l
=
pH2O*l
=
0.047
(rH2O/100)*patm
0.115
11.5
=
=
0.2367
904.8540412179
kPa*m
0.0272205
m*bar
din grafic
Agp
1.08
CO2p*(Tg/Tp)0,65+*H2Op
=
bar
kPa
bar
m
C
Coeficientul de corectie:
=
=
f(tp, pCO2*l)
f(tp, pH2O*l)
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
pCO2*l
=
=
pCO2
din grafic
din grafic
pH2O
=
=
=
0,9*dgech
patm
l
tp
Tp
Tg
=
=
=
=
1.6569
kPa*m
=
=
=
=
=
=
0.1472110816
0.061
(rCO2/100)*patm
0.07
7
0.065
(rH2O/100)*patm
0.115
11.5
=
=
=
=
0.2367
549.8853539423
823.0353539423
1178.0040412179
=
bar
kPa
=
bar
kPa
bar
m
C
K
K
pH2O*l
2.72205
kPa*m
f(pH2O, pH2O*l)
0.0272205
m*bar
Coeficientul de corectie:
qrg
r
g
=
din grafic
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp/100)4]
1.08
8730.0118007613
W/m2
q /(tg-tp)
24.5937518257
W/(m2*K)
g+
24.834844954
W/(m2*K)
CO2p*(Tg/Tp*)0,65+*H2Op
0.1233981146
r
g
r
g
|tp-tp*|
291.8516017563
Se reiau calculele:
- Agentul termic al peretelui
CO2p
f(tp*, pCO2*l)
=
Presiunea partiala pentru CO2:
f(tp*, pH2O*l)
(ta*a+tg*g)/(a+g)
=
=
>
=>
Agp
=
=
din grafic
pCO2
=
=
=
841.7369556986
=
pH2O
(ta2,II*a2,II+tg*g)/(a2,II+g)
Presiunea atmosferica:
patm
l
tp*
Tp*
Tg
=
=
=
=
1.6569
kPa*m
pH2O*l
Coeficientul de corectie:
2.72205
kPa*m
qrg
f(pH2O, pH2O*l)
din grafic
=
=
=
0,9*dgech
=
C
0.068
(rCO2/100)*patm
0.07
7
0.049
(rH2O/100)*patm
0.115
11.5
1
=
bar
kPa
=
bar
kPa
bar
=
=
=
=
0.2367
841.7369556986
1114.8869556986
1178.0040412179
m
C
K
K
0.0272205
m*bar
1.08
1546.1114930483
W/m2
*
p
=
din grafic
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp*/100)4]
r
g
q /(tg-t )
24.4959265835
W/(m2*K)
cg+rg
24.7370197118
W/(m2*K)
r
g
(ta*a+tg*g)/(a+g)
(ta2,II*a2,II+tg*g)/(a2,II+g)
841.5096232536
=
=
C
|tp*-tp**|
0.227332445
<
ETAPA 5
CALCULUL INALTIMII RECUPERATORULUI
TEVI (1)
ks1,I
W/(m *K)
ks1,II
W/(m *K)
2
2
tmed1,I
tmed1,II
17.153027224
ks2,I
W/(m2*K)
12.9462725305
17.6292339077
ks2,II
W/(m *K)
12.3665979011
834.2365782857
tmed2,I
726.8980525636
813.3592166166
tmed2,II
707.8600643783
Q1,I
kW
18.0151974097
Q2,I
kW
18.3928541753
Q1,II
kW
25.1923498625
Q2,II
kW
11.2157017226
S1,I
m2
1.2589515602
S2,I
m2
1.9544784093
S1,II
1.7569234789
S2,II
1.2812350168
l1,I
1.2523022745
l2,I
1.29610375
l1,II
1.7476441019
l2,II
0.8496453591
H1,I
0.8855114304
H2,I
1.29610375
1.2357709956
H2,II
0.8496453591
H1,II
1.066
143.54
2.029
=
=
=
=
=
=
1/[(1/g1,I)+(p/p)+(1/g1,I)]
0.0005
40
17.153027224
W/(m2*K)
17.6292339077
W/(m2*K)
12.9462725305
W/(m2*K)
12.3665979011
W/(m2*K)
m
W/m/K
1/[(1/g1,II)+(p/p)+(1/g1,II)]
0.0005
40
mm
W/m/K
Canalul inelar:
ks2,I
p
p
ks2,II
p
p
=
=
=
=
=
=
1/[(1/g2,I)+(p/p)+(1/g2,I)]
0.0005
40
mm
W/m/K
1/[(1/g2,II)+(p/p)+(1/g2,II)]
0.0005
40
mm
W/m/K
tmed1,I
(tmax-tmin)/ln(tmax/tmin)
834.2365782857
tmax1
t'g-t'a
851.5
tminI
t''g-tax,I
817.2080824358
tmed1,II
(tmax-tmin)/ln(tmax/tmin)
813.3592166166
tmax1
t'g-t'a
851.5
t''g-tax,II
776.3747491025
(tmax-tmin)/ln(tmax/tmin)
726.8980525636
t'g-t''a
643.5
tminII
C
C
C
C
C
C
Canalul inelar:
tmed2,I
tmax2
tminI
C
C
t''g-tax,I
817.2080824358
tmed2,II
(tmax-tmin)/ln(tmax/tmin)
707.8600643783
tmax2
t'g-t''a
643.5
tminII
t''g-tax,II
776.3747491025
(DaN/3600)*(iax,I-i'a)
18.0151974097
kW
(DaN/3600)*(iax,II-i'a)
25.1923498625
kW
(DaN/3600)*(i''a-iax,I)
18.3928541753
kW
(D /3600)*(i''a-iax,II)
11.2157017226
kW
C
C
C
C
X Fluxurile de caldura:
Tevi:
Q1,I
Q1,II
Canalul inelar:
Q2,I
Q2,II
N
a
Q1,I/(ks1,I*tmed1,I)
1.2589515602
m2
S1,II
Q1,II/(ks1,II*tmed1,II)
1.7569234789
m2
Canalul inelar:
S2,I
Q2,I/(ks2,I*tmed2,I)
1.9544784093
m2
S2,II
Q2,II/(ks2,II*tmed2,II)
1.2812350168
m2
S1,I/(nt**de)
S1,II/(nt**de)
1.2523022745
1.7476441019
S2,I/(*d2)
S2,II/(*d2)
1.29610375
0.8496453591
l1,II
Canalul inelar:
l2,I
l2,II
l1,I*cos(450)
0.8855114304
H1,II
l1,II*cos(450)
1.2357709956
Canalul inelar:
H2,I
H2,II
l2,I
1.29610375
l2,II
0.8496453591
1.066
143.54
lt
2.029
Detalii de citire:
1.400
1.300
1.200
1.100
H
1
1.000
0.900
0.800
0.700
0.600
100
105
110
115
120
125
130
135
140
145
150
155
160
165
170
175
180
185
190
195
200
In a lti m e a re c u p e ra to ru l u i, H [m ]
H
tax
II
tax [C]
122.5
163.3333
H1 [m]
0.886
1.236
0.009
H2 [m]
1.296
0.850
-0.011
0
1.066
143.54
0
200
1.066
143.54
1.066
b
143.54
0.00
-0.165
1.066
2.635
1.066
1.066
ETAPA 6
CALCULUL PUTERII CONSUMATE DE VENTILATORUL DE AER
DVA
m3/s
0.1408808245
pVA
Pa
6178.6730970859
PVA
1648.5919705695
p1
Pa
874.7992840734
p2
Pa
233.6177818681
p3'
Pa
93.673038215
p3''
Pa
297.6370378972
p4
Pa
178.9459550323
p5
Pa
4500
Puterea consumata de ventilatorul de aer in cazurile in care cuptorul nu este prevazut cu ventilator de gaze de
ardere:
PVA
(DVA*pVA)/(VA*ME)
1648.5919705695
0.1408808245
m3/s
(DaN/3600)*(Ta'/T0)
=
VA
0,5...0,7
=
0.6
=
ME
0,85...0,9
=
0.88
Pi - Pa
, unde:
Pa
Pi
=
=
P6 + P7
P1 + P2 + P3 + P4 + P5 + P6 + P7
si
, iar
Pa
=
P1 + P2 + P3 + P4 + P5
Pi
wi
=
densitatea fluidului in conditii reale.
fi
Calculul coeficientului
necesita stabilirea regimului de curgere a fluidului, pe baza criteriului Reynolds:
(wi*di)/i
Rei
=
, unde
6178.6730970859
Pa
k/di
r
=
, unde
k
=
rugozitatea absoluta a suprafetei peretelui pe partea fluidului
=
0.001
mm
=
- Daca Rei < 10/r, traseul se considera neted hidraulic, iar coeficientul de frecare se determina cu relatia Blasius: f i = 0,3164*Re-0,25
10^(-6)
- Daca 10/r < Rei < 560/r, traseul se considera semirugos hidraulic, iar coeficientul de frecare se determina cu relatia: f i = 0,11*(r+68/Re)0,25
- Daca Rei > 560/r, traseul se considera rugos hidraulic, iar coeficientul de frecare se determina cu relatia Sifrinson: f i = 0,11*r0,25 sau Prandtl-Nikuradse: 1/f i = 2lg(3,72/r)
In continuare vom analiza fiecare traseu in parte:
i=1
clapeta de reglare (sau un alt organ de reglare):
Pentru clapeta de reglare se recomanda uramatoarele:
X Coeficientul de pierderi locale de presiune pentru o clapeta de reglare deschisa 50% intre 3 si 6.
1
Se alege:
=
5
X Viteza de curgere a aerului:
w1
=
10...20
m/s
w1
Se alege:
X Densitatea aerului:
17
m/s
'a
=
1.2107948568
2
1*(w1 /2)*1
=
kg/m3
P1
Deci:
=
874.7992840734
i=2
conducta de aer intre ventilator si recuperator:
Pentru conducta de aer dintre ventilator si recuperator se recomanda urmatoarele:
X Viteza de curgere a aerului:
w2
=
10...20
m/s
w2
Se alege:
=
15
X Diametrul hidraulic echivalent:
(4*DVA/*w2)
d2
=
Pa
m/s
=
X Lungimea conductelor intre ventilator si recuperator:
l2
=
3...6
m
0.1093541759
l2
Se alege:
=
4.5
m
X Coeficientul de pierderi locale de presiune pentru un cot se considera 0,5:
2
=
2*0,5
=
1
X Densitatea aerului:
=
X Viscozitatea aerului:
2x104
=
X Numarul Reynolds:
Re2
=
'a
1.2107948568
kg/m3
'ax104
0.1492366762
m2/s
(w2*d2)/2
109913.506562902
X Rugozitatea absoluta:
r
10/r
Re2
=
=
k/d2
=
1093541.75928533
=>
<
10/r
X Coeficientul de frecare:
f2
=
0,3164*Re-0,25
9.1445981967
*10^(-6)
0.0173769563
>
2320
P2
[f2*(l2/d2)+2]*(w22/2)*2
Deci:
=
i = 3
traseul aerului prin recuperator - primul drum:
X Viteza de curgere a aerului prin tevi in conditii reale:
wa1N*{[(ta+tax)/2]+273,15}/T0
w3
=
=
X Lungimea traseului:
l3
=
1.2523022745
m
=
X Diametrul hidraulic echivalent:
d3
daech,1
=
=
0.039
m
X Coeficientul de pierderi locale de presiune:
3
[1-(nt*di2/d22)]2
di
0.039
d2
0.1093541759
buc
nt
=
X Densitatea aerului:
3
=
81.02182452
21.0080257524
Pa*s
aa
ta
18.5
tax
143.54
a106
a106
=
t
o
C
m/s
0.0003074023
aNT0/(t'a+273,15)
(ta+tax)/2
Pa
l1,I
233.6177818681
14.273994135
ta1
3106
1.2107948568
Kg/m3
Pa*s
17.2
106
0
81.02182452
100
21.9
X Viscozitatea aerului:
3x104
a1x104
=
X Numarul Reynolds:
Re3
=
X Rugozitatea absoluta:
(w3*d3)/3
k/d3
r
=
=
10/r
=
390000
Re3
=>
<
10/r
X Coeficientul de frecare:
f3
=
0,3164*Re-0,25
P3
0.1735060703
32084.5126844649
25.641025641
Deci:
=
i = 3
traseul aerului prin recuperator - al II-lea drum:
X Viteza de curgere a aerului prin canalul inelar in conditii reale:
=
=
2320
*10^(-6)
=
0.0236408242
[f3*(l3/d3)+3]*(w32/2)*3
=
wa2N*{[(tax+ta)/2]+273,15}/T0
w3
=
X Lungimea traseului:
l3
=
1.066
m
>
m2/s
93.673038215
12.1249810642
H
m/s
Pa
=
0.02
m
X Coeficientul de pierderi locale de presiune:
Se considera 2 coturi, 1 intrare si o iesire, cu intrare/iesire = 1.
3
2*0,5+1+1
=
=
3
X Densitatea aerului:
3
=
aNT0/(t''a+273,15)
185.02182452
25.3858948053
Pa*s
ta2
(tax+ta)/2
tax
143.54
ta
226.50
a106
a106
3106
=
t
o
C
Pa*s
100
21.9
106
185.02182452
200
26
X Viscozitatea aerului:
3x104
a2x104
=
X Numarul Reynolds:
Re3
=
(w3*d3)/3
aa
0.8474530889
0.2995551629
8095.3243794304
>
Kg/m3
m2/s
2320
X Rugozitatea absoluta:
k/d3
r
=
=
10/r
=
200000
Re3
=>
<
10/r
X Coeficientul de frecare:
f3
=
0,3164*Re-0,25
50
*10^(-6)
=
0.0333563031
2
[f3*(l3/d3)+3]*(w3 /2)*3
=
P3
Deci:
=
i=4
conducta de aer intre recuperator si arzator:
X Viteza de curgere a aerului:
w4
=
10...20
m/s
w4
Se alege:
X Lungimea traseului:
l4
=
17
3...6
297.6370378972
Pa
0.1344492848
m/s
l4
Se alege:
=
5
m
X Diametrul hidraulic echivalent:
d4
=
[{(4*DaN/3600)*[1+(t``a/273,15)]}/*w4]
X Coeficientul de pierderi locale de presiune:
Se considera 2 coturi.
4
2*0,5
=
=
1
X Densitatea aerului:
4
a
=
=
Kg/m3
X Viscozitatea aerului:
4x104
ax104
=
X Numarul Reynolds:
Re4
=
(w4*d4)/4
m2/s
59872.0434100112
>
2320
X Rugozitatea absoluta:
k/d4
r
=
=
10/r
=
1344492.84849264
Re4
=>
<
10/r
X Coeficientul de frecare:
f4
=
0,3164*Re-0,25
Deci:
i=5
P4
-
7.4377487476
=
0.0202269525
2
[f4*(l4/d4)+4]*(w4 /2)*4
=
=
traseul aerului prin arzator:
P5
1...10
*10^3
Pa
Se alege:
P5
4500
Pa
P3
*10^(-6)
P3 + P3
391.3100761122
178.9459550323
Pa
Pa
ETAPA 7
CALCULUL IZOLATIEI TERMICE
Grosimea izolatiei
Se trec datele de la ultima iteratie
Ri
(m*K)/W
0.2640027797
Re
(m*K)/W
0.0800993441
Riz
(m*K)/W
0.3168048715
119.1029876792
tpi
tm
79.5514938396
ql
W/m
249.6899347185
diz
iz
m
m
0.5675925233
0.0287962616
Date de intrare:
X Temperatura exterioara:
te
20
W/(m2*K)
(a2,I + a2,II)/2
2.4114131411
W/(m2*K)
0,045 + 0,00011*(tpi+tpe)/2
40
0,045 + 0,00011*tm
0.5
mm
0.0005
Presupunem ca:
ql
=
W/m
0
X Rezistenta interioara:
Ri
1/(*d3*a2)
(m*K)/W
[1/(2**iz)]*ln(diz/d4)
(m*K)/W
X Rezistenta exterioara:
Re
1/(*sp*e)
(m*K)/W
X Grosimea izlolatiei:
iz
X Diametrul izlolatiei:
20
mm
0.02
=>
W/(m*K)
diz
d4 + 2iz
0.55
0.551
diz + 2sp
X Rezistenta interioara:
Ri
1/(*d3*a2)
0.2640027797
(m*K)/W
1/(*dsp*e)
0.0825278419
(m*K)/W
242.3424572979
W/m
X Rezistenta exterioara:
Re
(tpe - te)/Re
(ta2 - tpi)/Ri
=>
185.02182452
X Temperatura aerului:
ta2
ta2 - ql*Ri
121.0427421423
(tpi + tpe)/2
80.5213710712
0.0538573508
W/(m*K)
X Temperatura medie:
tm
0,045 + 0,00011*tm
[(ta2 - te)/ql] - Ri - Re
0.3344141305
(m*K)/W
d4*e2**iz*Riz
0.5711061159
0.030553058
(d*iz - d4)/2
X Eroarea:
=>
|iz - *iz|
=
Se reiau calculele:
0.010553058
0.5711061159
X Diametrul izlolatiei:
d*iz
d4 + 2*iz
d*iz + 2sp
0.572106
X Rezistenta interioara:
Ri
1/(*d3*a2)
0.2640027797
(m*K)/W
1/(*dsp*e)
0.0794832281
(m*K)/W
X Rezistenta exterioara:
Re
10.5530579602
mm
>
mm
ql
(tpe - te)/Re
251.6254119189
W/m
(ta2 - tpi)/Ri
=>
185.02182452
X Temperatura aerului:
ta2
ta2 - ql*Ri
118.5920163181
(tpi + tpe)/2
79.2960081591
0.0537225609
W/(m*K)
X Temperatura medie:
tm
0,045 + 0,00011*tm
[(ta2 - te)/ql] - Ri - Re
0.3123373578
(m*K)/W
d4*e2**iz*Riz
0.5667055336
0.0283527668
(d**iz - d4)/2
X Eroarea:
=>
|*iz - **iz|
=
Se reiau calculele:
0.0022002912
0.5667055336
X Diametrul izlolatiei:
d**iz
d4 + 2**iz
d**iz + 2sp
0.567706
X Rezistenta interioara:
Ri
1/(*d3*a2)
0.2640027797
(m*K)/W
1/(*dsp*e)
0.0800993441
(m*K)/W
249.6899347185
W/m
119.1029876792
X Rezistenta exterioara:
Re
(tpe - te)/Re
(ta2 - tpi)/Ri
=>
185.02182452
X Temperatura aerului:
ta2
X Temperatura medie:
ta2 - ql*Ri
2.2002911692
mm
>
mm
tm
(tpi + tpe)/2
79.5514938396
0.0537506643
W/(m*K)
0,045 + 0,00011*tm
[(ta2 - te)/ql] - Ri - Re
0.3168048715
(m*K)/W
d4*e2**iz*Riz
0.5675925233
0.0287962616
(d***iz - d4)/2
X Eroarea:
|**iz - ***iz|
0.0004434949
0.4434948523
mm
<
mm
ETAPA 8
CALCULUL ECONOMIC
Calculul economic
MR
IR
Miz
Iiz
kg
127.9283873793
6396.4193689662
kg
12.9901943017
129.9019430168
7026.321311983
PVA
72.187305934
Can
/an
7893.3362076336
Tr
ani
0.8901586259
I/Can
0.8901586259
ani
Investitiile se calculeaza pe baza unui deviz de materiale si lucrari corespunzatoare tuturor fazelor de executie si montaj.
Penteru un calcul aproximativ se vor folisi relatiile urmatoare:
X Investitia in recuperator:
IR
MR * PR
6396.4193689662
127.9283873793
kg
(/4)*(d22 - d12)*H
VR * R
X Valoarea recuperatorului:
VR
(/4)*(d42 - d32)*H
Valoarea virolei
exterioare
Valoarea virolei
interioare
0.015393804
0.016
m3
7800
0.001
129.9019430168
kg/m3
50
/kg
X Investitia in izolatie:
Iiz
Miz * Piz
nt*(/4)*(de2 - di2)*lt
Valoarea
tevilor
Valoarea
tevilor
Valoarea
virolei
=
nt*(/4)*(de2 - di2)*lt
Viz * iz
12.9901943017
kg
(/4)*(diz2 - d42)*H
0.0519607772
m3
7026.321311983
X Valoarea izolatiei:
Viz
250
kg/m3
10
/kg
500
IR + Iiz + IVA
X Investitia totala:
I
7893.3362076336
/an
(DaN/3600)*(ia`` - ia`)
36.4080515851
kW
35
/(MW*h)
| [(p3` - p3``)*(DaN/3600)*(Ta/T0)]/(ME*VA) |
p3`
p3``
=
=
93.673038215
Pa
297.6370378972
Pa
D
Ta
T0
ME
VA
=
=
=
=
=
N
a
475
Nm3/h
ta+273,15
=
C
273.15
0.6
0.9
85
/(MW*h)
7000
h/an
0.14
an-1
395.65
72.187305934
ANEXA 1
ANEXA 2
ANEXA 3
ANEXA 4