Sunteți pe pagina 1din 44

Manual utilizare Coolwex Basic

20, 35, 45 kW
Cazan de joasa temperatura alimentat cu peleti

Cuprins
1. Avertizari generale ..............................................................................................................................................1 2. Instructiuni de siguranta ..................................................................................................................................... 2 3. Siguranta exploatarii ............................................................................................................................................ 4 4. Informatii despre cazan ............................................................................................................................. 5 4.1. Certi cat de calitate ........................................................................................................................................... 5 4.2. Declaratie de conformitate CE ........................................................................................................................ 5 5.1. Tipuri de cazane ................................................................................................................................................. 6 5.2. Date tehnice......................................................................................................................................................... 6 . .. 5.3. Intretinerea ......................................................................................................................................................... 8 5.4. Norme aplicabile .............................................................................................................................................. 11 5.5. Stare de livrare ...............................................................................................................................................11 5.6. Accesorii...............................................................................................................................................................12 5.7. Dimensiuni cazan ...........................................................................................................................................12 5.8. Schema electrica de conectare ....................................................................................................................14 5.9. Instalare ..........................................................................................................................................................16 5.9.1. Montarea cazanului ................................................................................................................................16 . 5. 9.2. Selectarea amplasarii ................................................................................................................................16 5.9.3. Example de montaj, scheme hidraulice .............................................................................................. 18 5.9.4. Pregatirea montajului ...............................................................................................................................19 5.9.5. Umplerea, alimentarea cu apa ..........................................................................................................19 5.9.6 Racordarea la cos ......................................................................................................................................19 5.9 .7. Conectarea electrica .............................................................................................................................. 20

5.10.8. Punerea in functiune ............................................................................................................................... 21 6. Selectarea functiilor ......................................................................................................................................... 23 6.1. Temperatura apa ............................................................................................................................................... 24 . 6.2. Dozarea aprinderii ..........................................................................................................................................25 6.3. Dozarea arderii ..................................................................................................................................................25 6.4. Dozarea stingerii ......................................................................................................................................26 6.5. Aerul de aprindere ...........................................................................................................................................26 6.6. Aerul de ardere ...............................................................................................................................................27 6.7. Aerul de stingere .............................................................................................................................................27 6.8. Setarea cu sau fara termostat de camera ................................................................................................28 6.4. Conectare modem telefon 6.11. Limba de comunicare .................................................................................... ............................29 ............................................................................................................................ 29 6.10. Resetare ............................................................................................................................................................ 29 6.12. Setare ora ........................................................................................................................................................ 30 6.13. Pornirea pompei ............................................................................................................................................30 6.14. Protectia impotriva inghetului .................................................................................................................... 31 6.15. Versiune software .......................................................................................................................................31 7. Curatarea si intretinerea cazanului ................................................................................................................ 31 7.1. Curatarea arzatorului .................................................................................................................................... 33 7.2. Pictograme operatiuni de curatare a cazanului ................................................................................ 33 8. Defecte, coduri de avarie si remediere .................................................................................................. 35

| Manual utilizare

Stimate utilizator! Va multumim pentru increderea acordata prin achizitionarea unui cazan Coolwex Basic - un produs modern, de inalta calitate si efcienta care va ofera cel mai inalt grad de confort, siguranta si abilitate in incalzirea centrala a locuintei dvs. serviciul nostru tehnic pentru asistenta si reglarea echipamentului. Pastrati manulul de utilizare deoarece contine informatii utile pentru instalarea rapida si exploatarea cazanului.

1. Avertizari generale
Cititi cu atentie acest manual pentru a va familiariza cu montajul corect, manevrarea, utilizarea si intretinerea cazanului. Acest produs este livrat intr-un singur colet. Daca continutul difera fata de comanda, luati legatura cu distribuitorul dvs. manual si normelor in vigoare. Se vor respecta atat normele locale cat si standardele europene. Fabricantul garanteaza ca produsul va functiona corect in perioada de garantie in condditii normale de functionare si cu respectarea instructiunilor din acest manual si a recomandarilor de garantie. Inainte de a efectua orice operatie la cazan cititi cu atentie manualul.

COOLWEX BASIC

Fabricantul nu isi asuma nici o raspundere pentru pagubele materiale sau accidentarea de persoane sau animale rezultate din greseli de montaj, reglare si intretinere sau datorate utilizarii necorespunzatoare. Pentru situatii de garantie informati imediat distribuitorul. cazanului nu depaseste limita superioara speci cata de 2,5 bar. Daca nu reusiti sa mentineti presiunea Daca nu utilizati cazanul montat o perioada mai lunga de timp exista diferite optiuni pentru a-l proteja impotriva inghetului. Se recomanda aplicarea uneia din procedurile de mai jos: - Setati selectorul de functii al cazanului la modul de protectie impotriva inghetului. Dupa aceasta electric. In acest caz functionarea cazanului este redusa la minimum necesar pentru a mentine in sistem o temperatura a apei de 5C.

- Umpleti instalatia sistemului de incalzire cu un lichid cu punct redus de inghetare. Puteti amesteca in apa de incalzire antigel sau alte produse similare: FSK, Schilling Chemie (proportie 2255 %) sau Glythermin N, BASF (proportie 2062 %) sau Antifrogen N, Hoechst / Ticona (proportion 2040 %). - Setati selectorul de functii al cazanului la OFF si goliti instalatia in caz de pericol de inghet. Intretinerea cazanului se va efectua cel putin o data pe an.

Acest manual face parte integranta din echipament si trebuie pastrat cu grija. Daca transmiteti cazanul altui utilizator, predati si manualul impreuna cu echipamentul. Daca manualul se deterioreaza sau se pierde, cereti o alta copie de la distribuitor.

2. Instructiuni de siguranta
Exploatarea de echipamente ce utilizeaza combustibil, electricitate si apa presupune respectarea anumitor reguli: - Se intrezice utilizarea cazanului de catre copii, persoane neresponsabile sau fara experienta. - Daca simtiti miros de combustibil in camera de montaj, aerisiti bine spatiul, deschizand usile si ferestrele,

| Manual utilizare

- Cazanul este un echipament electric: nu il atingeti cu parti ude ale corpului sau fara sa purtati incaltaminte. - Se interzice efectuarea oricarei interventii sau a curatarii cazanului inainte de a opri alimentarea electrica, setand selectorul de functii pe OFF. - Se interzice reglarea dispozitivelor de siguranta ale cazanului sau a regulatoarelor acestuia fara permisiunea prealabila a fabricantului. - Se interzice tragerea, deconectarea sau atingerea conductorilor, chiar daca alimentarea electrica a cazanului este oprita. - Cazanul nu este conceput pentru functionare in exterior.

- In cazul in care temperatura exterioara scade sub ZERO (pericol de inghet) si cazanul nu este in functiune, efectuati una din procedurile de mai sus. si nu lasati in apropiere de cazan combustibili lichizi, diluanti, vopsele, hartie, etc. - Daca sititi miros de gaze: Opriti cazanul.

Deschideti usile si ferestrele.

superioara, se aud zgomote puternice in interiorul cosului sau burlanul este foarte incins - atentie: pericol de arsuri! - opriti imediat cazanul. Inchideti si etansati toate deschiderile cazanului (usa arzatorului, cenusarul, carcase burlan). Inchideti toate celelalte deschideri posibile (usa pentru curatare si alte deschideri posibile) si asigurati-va ca nu se pot deschide datorita presiunii gazelor din cos. Dupa terminarea arderii si si apoi dupa auto-stingerea si racirea cosului urmariti constant cosul si Aceasta operatie produce in mod sigur explozia cosului si un incendiu in cladire. In cazuri extreme puteti raci obiectele din apropierea cosului incendiat si care pot lua foc la randul lor. Pe langa toate aceste operatii informati si serviciul de pompieri.

COOLWEX BASIC

- Trecere pe alt tip de combustibil:

Este interzisa montarea de dispozitive aditionale si utilizarea altui tip de

- Intretinere:

Utilizatorul raspunde de siguranta si de respectarea conditiilor de mediu la montaj Utilizati numai piese originale recomandate de fabricant!

- Aerul de ardere / aerul la locul de montaj:

Nu inchideti si nu reduceti priza de aer si ventilatia. Daca incaperea in care este montat cazanul are ferestre etanse, asigurati aductia de aer de ardere. evitati coroziunea.

Aerul de ardere / aerul din incapere nu trebuie sa contina substante agresive

3. Siguranta exploatarii
Explicarea simbolurilor
Acest simbol marcheaza in text avertizarile de siguranta in exploatare! daca nu se respecta masurile de reducere si prevenire a pagubelor. - Atentie arata ca se pot produce pagube materiale minore. - Avertizare arata ca se pot produce raniri usoare sau pagube materiale importante. - Pericol arata ca se pot produce raniri grave si in anumite cazuri deces.

Acest simbol marcheaza in text notele cu informatii. Notele contin informatii importante in cazurile in care nu se pot produce raniri sau pagube materiale.

| Manual utilizare

4. Informatii despre cazan 4.1.


Testarea acestui tip de cazan a fost efectuata de echipa de experti ai IMQ - primacontrol s.r.l. care a emis si Raportul de calitate. Asigurarea calitatii in productie garanteaza implementarea sistemelor de calitate aprobate pentu

cerintele pentru cazane de joasa temperatura. procesul de productie este supus unui control periodic de catre compania care a efectuat testarea.

4.2. Declaratie de conformitate CE


Conform urmatoarelor directive:
- Directiva europeana 73/23 EEZ si amendamentele ulterioare 93/68; - Directiva europeana 89/336 EEC si amendamentele ulterioare 93/68 EEC,92/31EEC,93/97EEC

Manual de utilizare

5.1. Gama de puteri


Denumire Putere

Coolwex Basic 35

Coolwex Basic 20

20 kW 35 kW 50 kW

Coolwex Basic 45

5.2. Date tehnice


Parametri
Tip cazan Putere termica nominala Putere termica minima Randament Clasa cazan

U/M
kW % -

20 kW
20 8

Basic 20

Basic 35 35 14 3

35 kW

50 kW

kW

Basic 45 50 92,6 3 20

91,8 3 48/372 119 2,5 95 50

90,7 139/311 131 65 2,5 95

CO masurat cu 10% oxigen la putere termica mg/m 3 niminala / putere termica minima (EN 303-5) Temperatura gaze arse Debit gaze la ardere m /h
3

335/264 142 2,5 neconditionata fara piederi 95 80

Presiune max. admisa a apei la functionar Temperatura max. admisa la functionare Temperatura max. in circuitul de retur cazan

bar C C

Pierdere presiune apa

mbar

neconditionata neconditionata fara piederi fara piederi

Conectare apa (circuit tur / retur) Conditii minime de tiraj cos Diametru racord gaze arse

Racorduri tur/retur, gaze arse

Inaltime racord cos

mm

mm

Pa

neconditionat 680 114

neconditionat 724 114

neconditionat 975 114

1 1/4

COOLWEX BASIC

Conectare electrica
Tensiune de control

Tensiune de conectare Putere instalata

V/Hz W V

UM

AC 220/50 DC 12 300 1024

20 kW

AC 220/50 DC 12 300 1024

35 kW

AC 220/50 DC 12 300 1024

50 kW

Putere instalata max. pompa

Dimensiuni

Capacitate apa Latime cazan Greutate

Lungime cazan

Inaltime cazan

mm kg

mm

1230 1360 310 600

110

1410 1550 395 600

145

1150 1690 480 930

150

mm

Combustibil

Peleti din lemn Durata de ardere Umiditate

mm h

normal 10/optional 25 normal 10/optional 25 normal 10/optional 27 pana la 12 pana la 12 pana la 12

6 umiditate pana la 12%

6 umiditate pana la 12%

6 umiditate pana la 12%

Manual de utilizare

5.3. Intretinerea
- Aceste cazane sunt proiectate pentru functionarea cu peleti (diametru: 6mm; lungime: max.30mm) Structura acestui cazan este realizata din otel, prin sudarea de straturi de tabla. Sunt 3 straturi de baza (partea interioara - foc, partea mediana - apa si partea exterioara de protectie), ansamblul arzatorului si rezervorul de depozitare peleti. Partea interioara este confectionata din tabla de otel 4/W4/HII /DIN 17155, iar partea mediana din tabla de metal 4/R St 37-2.

- Fluxul de gaze pe drumurile de fum: gazele erbinti de la arzator se ridica in prima camera, sunt partial racite de schimbul de caldura cu apa prin corpul cazanului, apoi sunt trase in jos si intra in a doua camera de schimb, trecand peste acara arzatorului intretinand in acest fel arderea compusilor de gaze combustibile, si peste cenusa, arzand toate resturile posibile care nu au ars complet. Mantaua camerei este in contact cu apa si astfel gazele calde circula in jurul acesteia, mergand in sus in a doua camera unde sunt racite si de unde pornesc in jos spre cea de-a treia camera. Al patrulea schimbator de caldura este tubular, permitand utilizarea maxima perioada de utilizare a caldurii. cu precizie dozarea peletilor. Acesta consta din doua roti melcate cuplate cu un angrenaj cu lant si conduse de un electromotor cu turatie redusa prin intermediul unui reductor. Aceasta solutie constructiva asigura dozarea controlata a peletilor si totodata protectia impotriva autoaprinderii peletilor din rezervorul de depozitare. Roata melcata inferioara se roteste mai repede decat cea de sub rezervorul de depozitare si astfel calea de aductie este intotdeauna libera de peleti. Ventilatorul de incalzire a aerului tarea controlata de aer de ardere se realizeaza cu o turbina de aer cu reglare directa a turatiei turbinei.

COOLWEX BASIC

- Exploatarea cazanului este automatizata cu modul electronic. Unitatea de reglare la intrare este Reglarea si exploatarea cazanului este realizata de acest modul. Functiile reglate direct in acest mod sunt: temperatura apei, dozarea aprinderii, dozarea arderii, dozarea stingerii, aerul de aprindere, aerul de ardere, aerul de stingere, pornirea pompei.

- Pentru asigurarea unei mai mari sigurante cazanul este dotat cu o sonda, intercalata in circuitul de reglare a curentului pentru control si reglare electronica, care masoara permanent temperatura apei. In cazul depasirii temperaturii limita (>100C) sonda de siguranta opreste automat cazanul si il

trerupator de siguranta si o broasca electronica pentru deschidere in siguranta in timpul functionarii cazanului. La deschidere, microintrerupatorul usii taie circuitul de curent al turbinei de aer si al inchiderea usii arzatorului cazanul este din nou in stare de functionare. Daca usa ramane deschisa mai mult timp si tmperatura scade, pe ecran apare eroarea furnace extinguish (stingere cazan); Deoarece pentru reglarea functionarii cazanului usa trebuie sa ramana deschisa, pe usa este montata o broasca electronica activata cu cheie. In acest mod se evita activarea microintrerupatorului. Cheia este o piesa detasabila. Cand este introdusa in broasca si rasucita la 90, broasca este activa si pana ce nu revine in pozitia initiala, iar pozitia broastei (montata intr-o carcasa de protectie) nu permite inchiderea usii exterioare a carcasei pana ce cheia nu este scoasa din broasca. Astfel nu puteti uita inchiderea broastei si nu puteti lasa usa arzatorului deschisa fara protectie. montat un ventilator, care este parte integranta a cazanului. Modulul electronic regleaza turatia acestuia, astfel ca aspiratia produsa sa aiba intotdeauna valoarea de 3540 Pa necesara pentru a invinge rezistenta din drumurile de fum si pentru a asigura aspiratia necesara de 20 Pa in arzator. Cand porniti cazanul porneste mai intai ventilatorul (astfel incat toate gazele remanente sunt trase in cos) si dupa o perioada de timp porneste si cazanul. Dupa stingerea cazanului ventilatorul continua sa functioneze 2 minute pentru a elimina gazele remanente produse de ardere. Ventilatorul functioneaza fara zgomot. Nu este necesara curatarea ventilatorului deoarece nu exista depuneri de impuritati ca funingine, cenusa, condens.

- Alte componente ale cazanului: carcasa tuburi de fum, bariere de turbulenta in tuburile de fum, carcasa arzator, manta exterioara cu izolatie termica, usa arzator, usa cenusar, usa deasupra tuburilor de fum, iesire fum, rezervor depozitare peleti.

10 |

Manual de utilizare

- Piese care pot

montate suplimentar: regulator temperatura camera, modem comanda prin telefon.

- Cazanul se porneste, apasand butonul de pe ecran sau telecomanda.

- Gradul de ardere: arderea peletilor este de 99%. La peletii de calitate standard in urma arderii a 1000 kgs masa de incalzire ramane mai putin de 1 kg de cenusa si zgura. de lucru este de 40C. Aceasta conditie este asigurata de controlul electonic al pompei de apa, astfel incat pompa nu porneste pana cand temperatura apei in cazan nu atinge valoarea minima necesara de 40C. - Dimensiunea tevilor depinde de puterea cazanului; pentru cazanul de 20 si 35 kW diametrul este R1, iar pentru 45 kW este R1. - Cazanul este complet izolat termic si nu incalzeste camera in care este montat. Temperatura max. la suprafata cazanului este sub 85C. De aceea nu sunt necesare masuri de protectie speciale pentru

- Presiunea de lucru a apei in sistem (presiunea masurata la conectare, cu cazanul in functiune) este de 1,02,0 bar. Montati o supapa de siguranta (conform schemei incluse) pe teava de iesire din cazan si reglati sa evacueze la 2,5 bar.

delor europene si fabricantul a prevazut elementele necesare de protectie si siguranta in conformitate cu acestea. speciale de pe spatele usilor si capacelor. - Cazanele de 20, 35 si 50 kW au o aerisire mecanica pe partea superioara a cazanului.

- Alimentarea electrica respecta cerintele de siguranta prevazute in reglementarile pentru de 3 x 1,5 mm2 , deci cu conductor de protectie. Alimentarea electrica se face printr-o priza speciala cu impamantare care nu permite conectarea altor echipamente.

- Toate componentele cazanului expuse la temperaturi ridicate sunt protejate cu un strat de vopsea ignifuga pentru metale, rezistenta la temperaturi de pana la 700C. Alte componente ale cazanului sunt protejate cu doua straturi de vopsea anticoroziva. Mantaua exterioara este protejata prin aplicarea de vopsea pulbere. Toate cazanele sunt vopsite in gri-galben. - Este asigurat si programul de protectie impotriva inghetului. - Nu exista emisii de gaze toxice in zona din jurul cazanului sau in camera acestuia.

COOLWEX BASIC

| 11

5.4. Norme aplicabile


Pentru proiectarea si constructia cazanelor s-au aplicat urmatoarele directive si reglementari: - Constructia de cazane armonizata cu directivele europene 98/37/EC, 97/23/ EC si standardele europene EN 292-1:1991, EN 292-2:1991, EN 12952-2, EN 12952-3, EN 12952-4, EN 12952-5, EN 60335-2.

- BS EN 292-1:1991 - Siguranta masinilor. Concepte de baza, principii generale de proiectare. Terminologie, metodologie de baza. - BS EN 292-2:1991 - Siguranta masinilor. Concepte de baza, principii generale de proiectare.

- BS EN 12952-2:2001 - Cazane cu tevi de apa si instalatii auxiliare. Materiale pentru piesele sub presiune ale cazanelor si accesoriilor. - BS EN 12952-3:2001 - Cazane cu tevi de apa si instalatii auxiliare. Proiectarea si calculul pieselor sub presiune.

- BS EN 12952-4:2000 - Cazane cu tevi de apa si instalatii auxiliare. Calcule durata de viata cazan in exploatare.

- BS EN 12952-5:2001 - Cazane cu tevi de apa si instalatii auxiliare. Fabricarea si constructia pieselor sub presiune ale cazanului. incalzire, ventilatie sau aer conditionat.

Testarea cazanului s-a efectuat in conformitate cu EN 303-5. Testele hidraulice se efectueaza cu control 100%. Fiecare cazan livrat a fost testat conform protocolului la o presiune a apei de 4 bar,

5.5. Stare de livrare


- Cazan pentru incalzire centrala - Accesorii pentru curatare - Container pentru peleti

- Manual de utilizare, montaj si intretinere - Dispozitiv avertizare sonora

12 |

Manual de utilizare

- Steker conectare pompa electrica

- Cazanul se livreaza pe un palet din lemn; este acoperit cu unstrat de polistiren, si infasurat in folie, in cutie de carton cu etichete si instructiuni imprimate.

5.6. Accesorii
- Razuitor

- Teava pentru curatat arzatorul - Lopatica

Ca accesoriu suplimentar puteti comanda aspiratorul corespunzator pentru cenusa.

5.7. Dimensiuni cazan


Coolwex Basic 20
400
600

780

1360

tur 1

ventilator racord cos

850

retur 1

golire 1

530 115

1230

770

O 114

COOLWEX BASIC Coolwex Basic 35


400
600

| 13

780

1550

tur 1

ventilator racord cos

850

retur 1

golire 1

530

770

O 114

1410

Coolwex Basic 45

1150

420

ra r

en

510

tur 1,1/4 ventilator


1690

racord cos O 114


1067

1160

R op ezer tio vo na r s l up lim en

R op ezer tio vo na r s l u

pl

im

ra r

golire 1 retur 1, 1/4


167

930

540

975

115

14 |

Manual de utilizare

5.8. Schema de conectare elemente electrice


Denumire piesa ALIMENTARE ELECTRICA ALIMENTARE ELECTRICA ALIMENTARE ELECTRICA SONDA DE SIGURANTA SONDA DE SIGURANTA VENTILATOR VENTILATOR TURBINA TURBINA POMPA POMPA Numar 1 2 3 4 5 6 7 8 10 12 11 9

SONDA GAZE ARSE SONDA GAZE ARSE SONDA APA SONDA APA

INTRARE TELEFON

INTRARE TELEFON

TERMOSTAT CAMERA

TERMOSTAT CAMERA

ALARMA

ALARMA

APRINZATOR (2kW)

APRINZATOR (2kW)

INSTALATIE DOZARE

INSTALATIE DOZARE

21 22 23 24 26 25

20

19

18

17

16

15

14

13

CONECTOR ECRAN

COOLWEX BASIC

| 15

Schema electrica

F1 32mA

napajanje

Alimentare

220V+N
Termostat Termostat
termostat

F2 10A

Motor 1 Motor 2 Motor 3 Motor 4

Blower 1 Suflanta 1
ventilator 1

1~

Blower 2 Suflanta 2
ventilator 2

1~

Pump Pompa
pumpa

1~

Stoker Focar
dozator

1~

Ignition Aprindere grija Door Broaste usa vrata Iocks


brava

NN L L NN L

Alarm Alarma

12 DC

Termostat Termostat Telefon Phone s Temp. senzor Senzor temp.


Temp. senzor s Senzor temp.

N L L L

16 |

Manual de utilizare

5.9. Instalare
Nota: Montajul, conectarea electrica, conectarea la cosul de fum si

5.9.1. Montaj cazan


- Inainte de a alege tipul de cazan consultati un distribuitor autorizat. - Inainte de prima punere in functiune cititi cu atentie manualul tehnic. Daca aveti neclaritati producatorului. - Cazanul se integreaza in sistemele de incalzire centrala conform DIN. 4751-1 si DIN. 4751-2 (componente de siguranta obligatorii pentru sisteme de incalzire deschise si inchise). Aceste componente cuprind: manometru de presiune cu termometru, robinet de izolare, pompa de circulatie, supape de siguranta, vas de expansiune. - Pompa de circulatie se conecteaza obligatoriu prin cazan.

- Este strict interzisa aprinderea si arderea in cazan a deseurilor sau altor materiale combustibile. - Este strict interzis sa adaugati si/sau sa turnati combustibil lichid. - Inainte de punerea in functiune a cazanului ventilati obligatoriu aerisirea mecanica. Atentie: Deoarece diferite deseuri si resturi ramase in tubulatura pot deteriora cazanul - spalati instalatia pentru a indeparta toate resturile.

5.9.2. Selectarea amplasarii


- Cazanul trebuie asezat pe o suprafata plana, necombustibila. Spatiul de manevra in fata cazanului de 50 sau 200 mm. Fetele laterale ale cazanului de la arzator si cosul lateral necesita un spatiu de minimum 400 mm. Consultati schema de montare a cazanului in camera repartizata.

COOLWEX BASIC

| 17

- Asigurati-va ca suprafata de montaj are capacitatea de sustinere necesara. Aceasta este determinata de rezervorul de depozitare si de tipul cazanului. (aprox. 2000 kg/m). Daca suprafata existenta nu respecta aceasta cerinta, luati masuri corespunzatoare in vederea unei mai bune distributii a sarcinii. - Respectati instructiunile de montaj al kiturilor de conectare a burlanelor referitoare la masurile mimine de incastrare. La montajul cazanelor se vor respecta reglementarile locale si profesionale si in special standardele internationale. - Functionarea economica si sigura a cazanului se asigura prin respectarea in timpul montajului a reglementarilor si instructiunilor din acest manual.

Schema de amplasare 50 kW Imagine vazuta de sus.

Schema de amplasare 20, 35 kW

200

930

400
600

1075

400

400
600

1180

600

50

400

18 |

Manual de utilizare

5.9.3. Exemple de montaj scheme hidraulice

Sistem cu vas de expansiune inchis pentru sisteme de incalzire centrala cu combustibil solid cu cazane de pana la 93 kW in cazul in care sunt montate echipamente speci cate pentru sisteme inchise (supapa de siguranta, termometru si maneometru vas de expansiune cu membrana cu volum corespunzator si protectie termica - sonda de protectie activata la depasirea temperaturii de 95C, bypass cu robinete de oprire). In cazul nostru este permisa o putere termica mult mai mare deoarece combustia poate oprita relativ repede.
C P 1 2 3 4

Sistem inchis, racordarea cazanului cu si fara acumulator tampon.

Cazan Pu er - acumulator tampon Vas de expansiune cu membrana Supapa siguranta 2,5 bar (2 buc). Pompa de circulatie Ventil termic de amestec
1

C 3 4

1 2

C 3 4

COOLWEX BASIC

| 19

5.9.4. Pregatirea montajului


Inainte de montaj indepartati cazanul de pe palet. Indepartati de asemenea toate capacele si cuplele de protectie. - Conectati cazanul la cos astfel incat sa asigurati o usoara inclinare spre cazan sau pozitia orizontala. de alimentare si evacuare. - Asezati cazanul pe locul ales pentru instalare.

5.9.5. Umplerea, alimentarea cu apa

alimentare spalati inca o data cu presiune intregul sistem de incalzire pentru a indeparta toate reziduurile din tevi patrunse la montaj sau inainte. - In timpul functionarii incalzirii centrale trebuie mentinute volumul constant si presiunea apei in sistem. Nu este permisa evacuarea de apa de incalzire din sistem cu exceptia situatiilor inevitabile, ca reparatii etc. Asigurati-va ca in timpul alimentarii in sistem nu patrunde aer. Evacuarea apei din sistem si realimentarea favorizeaza coroziunea si formarea de calcar. Alimentarea sistemului cu apa este permisa numai cand cazanul este rece, altfel exista pericolul deteriorarii acestuia. intregul sistem. - Ventilati cazanul prin aerisirea mecanica incorporata in cazan.

5.9.6. Conectarea la cos


pe iesirea din cazan ca parte integranta a acestuia. Turatia ventilatorului este controlata printr-un modul electronic, astfel incat aspiratia necesara de 20 Pa este permanent asigurata la nivelul arzatorului.

20 |

Manual de utilizare

- Diametrul recomandat al cosului este de 114 mm. Inaltimea cosului nu este conditionata (inalpatrunderea condensului din cos in cazan, introduceti burlanul cat mai adanc in cos. Tubul de iesire din cos trebuie confectionat din otel inoxidabil. impotriva vantului. Exemplu de cos amplasat corect

5.9.7. Conectarea electrica

Pericol de electrocutare!

Inainte de a efectua orice lucrare la partea electrica a cazanului scoateti stecherul din priza.

Toate dispozitivele de reglare, control si siguranta ale cazanului au fost cablate si testate in fabrica. - Montati o priza monofazata intr-un loc accesibil pentru alimentarea cazanului.

COOLWEX BASIC

| 21

Nota: Conectarea electrica trebuie sa respecte normele in vigoare pentru instalatii electrice casnice. CABLUL DE ALIMENTARE ELECTRICA SE CONECTEAZA NUMAI LA O PRIZA CU IMPAMANTARE - 230V/50Hz

- Circuitele electrice ale cazanului sunt protejate cu o siguranta fuzibila de 10A. Cand siguranta

CAZANUL TREBUIE PROTEJAT IMPOTRIVA FLUCTUATIILOR DE TENSIUNE ELECTRICA.

siguranta originala de acelasi curent nominal. Este strict interzisa orice improvizatie sau reparare * Conductorul de protectie este obligatoriu. Pornirea si oprirea electrica a cazanului (ON/OFF) Pornirea (ON) Porniti cazanul, conectand stecherul cablului de alimentare la priza monofazata alocata. intermediul tastelor de functii treceti prin meniul de acces si efectuati ajustarile necesare. Oprirea (OFF) Oprirea cazanului se realizeaza in ordine inversa. Cand apasati butonul de oprire cazanul incepe procesul de oprire. Aceasta procedura dureaza intre cateva minute si max. 10 minute, in functie modul de functionare a cazanului. Dupa oprirea cazanului de la butonul de oprire, cand ecranul

5.9.8. Punerea in functiune


Avertizare: Punerea in functiune fara apa distruge cazanul! - Nu lasati cazanul sa functioneze fara apa.

22 |

Manual de utilizare

- Pre-presiunea vasului de expansiune setata la inaltimea statica a instalatiei de incalzire. - Deschideti robinetele radiatoarelor. - Incarcati incet instalatia de incalzire la 1 bar.

- Conectati pompa de circulare la priza de pe cazan. - Aerisiti radiatoarele. - Completati apa din instalatia de incalzire pana la 1 bar. rezervor se face in functie de situatie, in functie de anumiti factori de in uenta asupra consumului: temperatura din exterior, temperatura dorita in spatiul incalzit, izolatia cladirii...) cand apare alarma furnace extinguish (stingere cazan). Aprinderea si incalzirea - Deschideti robinetele de izolare dintre cazan si sistemul de incalzire. - Curatati cazanul de cenusa si zgura. - Detalii despre exploatarea cazanului in capitolul Selectarea functiilor

- Daca este montat un regulator de temperatura suplimentar, reglati-l la temperatura dorita in camera (vezi instructiuni pentru regulatorul de temperatura). Toti utilizatorii de regulator de temperatura Pericol: Fiecare deschidere a usii cazanului in timpul functionarii acestuia trebuie efectuata treptat si lent, si nu inainte de perioada minima de 2 minute de cand cazanul inregistreaza ardere. Aceste precautii sunt necesare din motive de siguranta deoarece exista pericolul acumularii de gaze nearse care se pot scurge in spatiul inconjurator si pot exploda la deschiderea brusca a usii. Usa poate ramane deschisa numai pe perioada reglarii functionarii cazanului. Cand efectuati operatii de reglare

COOLWEX BASIC

| 23

6. Selectarea functiilor
Cazanele sunt dotate cu combustie auto-reglabila. Inainte de a pune cazanul in functiune

Pornire/oprire ON/OFF Navigare meniu Navigare meniu

Revenire din meniu

24 |

Manual de utilizare

6.1. Temperatura apa

Domeniul de reglare este cuprins intre 40C si 90C.

Modul 1 de functionare - fara termostat

Prin reglarea temperaturii apei se regleaza temperatura cazanului, temperatura radiatoarelor si temperatura de incalzire a zonei incalzite. - cladire bine izolata, temperatura din exterior foarte scazuta | apa 80C - cladire bine izolata, temperatura din exterior scazuta | apa 70C - cladire bine izolata, temperatura din exterior moderata | apa 60C Modul 2 de functionare - cu termostat

Pentru aceasta reglare se iau in calcul diferiti factori ca: raportul dintre spatiul incalzit si puterea instalata a cazanului, izolatia termica a cladirii, temperatura din exterior in momentul reglarii, calitatea si amplasarea corpurilor de incalzit, destinatia spatiului incalzit, etc. In general se recomanda reglarea la valoarea medie a temperaturii apei. Pe langa reglarea termostatului trebuie luata in consideratie si reglarea temperaturii apei in cazan. experienta acumulata in timpul exploatarii cazanului si pentru a obtine o incalzire mai

COOLWEX BASIC

| 25

6.2. Dozarea aprinderii

Este foarte important sa restrictionati functia de dozare a aprinderii la max. 15%. Selectarea incorecta a unui procent mai mare decat 15% pentru dozarea aprinderii poate deteriora cazanul. Daca utilizati peleti de calitate garantata se recomanda reglarea functiei de dozare a aprinderii la 10%. Dozarea minima a aprinderii este deja reglata la 5%.

6.3. Dozarea arderii

Pentru cazane de pana la 20kW:

- 25% pentru cazanul de 20 kW - 35% pentru cazanul de 35 kW - 45% pentru cazanul de 45 kW

Daca este necesara puterea termica maxima a cazanului pentru peleti recomandati de calitate garantata cu puterea de ardere/incalzire de 4,8 kWh/kg se recomanda reglarea functiei de dozare a arderii la:

Daca nu este necesara puterea tremica maxima a cazanului reglati functia de dozare a arderii la un procent mai mic.

Daca utilizati peleti de calitate mai slaba este permisa o crestere a functiei de dozare a arderii cu pana la 5% in cazul ecarui cazan.

26 |

Manual de utilizare

Supradozarea duce la arderea incorecta a peletilor. De asemenea poate determina acoperirea arzatorului si poate impiedica aprinderea peletilor. Daca conditiile necesare pentru cos nu sunt indeplinite, pentru a atinge puterea nominala trebuie montat un ventilator de tiraj in burlan.

Daca nu este necesara puterea termica maxima a cazanului reglati functia de dozare a arderii la un procent mai mic.

Reglajul minim pentru functia de dozare a arderii este limitat la 15% pentru modelele de 20 si 35 si 20% pentru Basic 45.

6.4. Dozarea stingerii


Functia dozarea stingerii se regleaza la aprox. jumatatea valorilor selectate la functia explicata mai sus dozarea arderii.

6.5. Aerul de aprindere


Reglarea acestei functii este limitata intre 5% si 100%. necesare de aer de aprindere. Pentru peletii produsi si comercializati in UE si pe baza experientei acumulate pana in prezent, se recomanda o cantitate de aer de aprindere intre 25% si 40%.

COOLWEX BASIC

| 27

6.6. Aerul de ardere

- calitatea peletilor si cantitatea acestora in arzator

Din aceste motive se recomanda reglarea vizuala a aerului de ardere. Valorile orientative de reglare sunt cuprinse intre 20% si 70%. Arderea corecta: Flacara stralucitoare fara aparitia de fum negru. Arderea incorecta: de aer de ardere.

6.7. Aerul de stingere


Dupa reglarea aerului de ardere trebuie reglata si funtia de aer de stingere. Este important de retinut ca modul de stingere al cazanului porneste la o temperatura cu 5C mai mare decat temperatura setata pentru functia temperatura apei.

28 |

Manual de utilizare

In modul de stingere alimentarea cu peleti se reduce si de aceea si volumul necesar de aer pentru arderea peletilor este de asemenea redus. Pentru acest reglaj se aplica toate recomandarile anterioare de la explicarea functiei aerul de ardere. Valoarea de ajustare a functiei aer de stingere este intotdeauna cu o nuanta mai mica decat valoarea functiei aer de ardere.

6.8. Setarea cu sau fara termostat de camera


Important:

Daca nu este montat un termostat aceasta functia trebuie setata la blocked (blocat) pentru a permite functionarea cazanului. Cazanul nu mai asteapta informatii de la temostat ci functioneaza pe baza functiei speci ce temperatura apei.

Cand termostatul este montat aceasta functie este setata la enabled (activat). Aceasta setare comanda cazanului sa astepte informatiile de la termostat inainte de a incepe sa functioneze.

COOLWEX BASIC

| 29

6.9. Conectare modem telefon


Aceasta functie da posibilitatea de montare a unor dispozitive care permit pornirea cazanului de la distante mari, prin semnal telefonic. Important: Daca dispozitivul mentionat nu este instalat, functia trebuie setata la blocked (blocat) pentru a permite functionarea cazanului.

6.10. Resetarea

Aceasta functie permite utilizatorului sa anuleze toate setarile efectuate prin meniu si sa revina la reglarile anterioare (implicite) din fabrica. cazanului sau in cazul unor nelamuriri, se recomanda notarea intotdeauna a valorilor de pornire a reglajelor.

6.11. Limba de comunicare


Aceasta functie permite selectarea limbii de comunicare din meniul dispozitivului software.

30 |

Manual de utilizare

6.12. Setare ora

Aceasta functie este in curs de perfectionare.

6.13. Pornirea pompei

Aceasta functie permite reglarea temperaturii la care porneste pompa de apa. Domeniul de reglare a functiei este cuprins intre 40C si 95C. Temperatura se regleaza in trepte de cate 1C.

COOLWEX BASIC

| 31

6.14. Protectia impotriva inghetului


Daca din anumite motive cazanul nu va functiona o perioada mai lunga de timp activati aceasta functie. Astfel cazanul va functiona la minimum si va regla temperatura apei din cazan la aprox. 5 C.

6.15. Versiunea software

Aceste date sunt necesare fabricantului sau personalul de service. Pentru dvs. aceste date sunt necesare daca doriti informatii de la fabricant sau personalul de service cu privire la exploatare pentru a le indica acestora versiunea software corecta a modulului electronic al cazanului.

7. Curatarea si intretinerea cazanului


zile curatati arzatorul si spatiul de dedesubtul acestuia.

32 |

Manual de utilizare

Explicatie: in arzator peletii ard la temperatura foarte ridicata (pana la 1200C) nisipul se topeste si se aglomereaza, formand bucati mari de zgura. Zgura umple in timp spatiul din arzator si impiedica procesul de ardere, iar cazanul incepe sa scoata fum, inseamna ca trebuie curatat.

5.7.12. Reinigungen des Rauchrohres

Drumurile de fum se curata o data pe luna sau cand cazanul incepe sa scoata fum.

Curatarea este simpla si practica. Indepartati capacul drumurilor de fum (desurubati piulita uture) pentru acces in camera tuburilor de incetinire (turbulatori) Retrageti turbulatorii si lasati cenusa sa cada din ele. Curatati interiorul camerei cu o perie si inchideti capacul.

Dupa curatarea drumurilor de fum cenusa cade in spatiul de sub camera. Cenusa se indeparteaza din cazan prin greblare sau cu un aspirator special pentru cenusa. Aceasta procedura este recomandata de ecare data cand reincarcati tancul de peleti. Drumurile de fum trebuiesc curatate o data pe luna sau cand apare fum negru.

COOLWEX BASIC

| 33

7.1. Curatarea arzatorului

5-7 zile si chiar mai des deca utilizati peleti cu continut mare de impuritati. O parte din nisipul neaglomerat in zgura cade prin gratar si ramane pe fundul arzatorului. Rotiti fundul arzatorului spre stanga, indepartati fundul arzatorului si murdaria acumulata.

34 |

Manual de utilizare

COOLWEX BASIC

| 35

8. Defecte, coduri de avarie si remediere


Defect Cauza Remedierea
pentru a opri semnalul sonor

Alarma emite o avertizare sonora care dureaza pana la interventia dvs. (apasati tasta si a efectua resetarea). Alarma: Sonda de fum 1. Sonda de fum defecta.

1. Cereti asistenta de la personal service autorizat. 2. Cereti asistenta de la personal service autorizat.

2. Comunicatie intrerupta (cablu deconectat).

Alarma: Sonda de apa

1. Sonda de apa defecta. 2. Comunicatie intrerupta (cablu deconectat).

4. Cereti asistenta de la personal service autorizat. 5. Cereti asistenta de la personal service autorizat.

Alarma: Eroare aprindere

1. Lipsa peleti. 2. Arzator blocat de zgura si cenusa. 2. Drumuri de fum infundate. 4. Acces blocat al peletilor in arzator. 4.1. Datorita calitatii reduse, peletii nu cad corect in axul melcat. 4.2. Aprindere electrica defecta (indicatie arzator rece). 4.3. Peleti de calitate inferioara (toate celelalte cauze sunt excluse dar aprinderea nu functioneaza)

1. Umpleti containerul cu peleti. 2. Curatati arzatorul. 3. Curatati burlanele. 4.1. Scuturati peletii, , resetati alarma si porniti din nou aprinderea cazanului . 4.2. Cereti asistenta de la personal service autorizat. 4.3. Reglati din nou functia de aprindere si functia de dozare. 5. Daca nu reusiti sa eliminati eroarea cereti asistenta de la personal service autorizat.

Cazanul a primit semnalul de pornire dar nu s-a putut aprinde.

36 |

Manual de utilizare

Defect
Alarma: Stingere cazan 1. Lipsa peleti.

Cauza

Remedierea
1. Umpleti containerul cu peleti. 2. Curatati arzatorul. 3. Montati corect capacul inferior al arzatorului. 4. Curatati burlanele. 5.1. Scuturati peletii, , resetati alarma si porniti din nou aprinderea cazanului . 5.2. Reglati din nou functia de ardere si functia de dozare.

2. Arzator blocat de zgura si cenusa. 3. Capacul inferior al arzatorului montat gresit dupa curatare. 4. Drumuri de fum infundante. 5. Acces blocat al peletilor in arzator. 5.1. Datorita calitatii inferioare peletii nu cad corect in arzator. 5.2. Peleti de calitate inferioara (toate cauzele de mai sus sunt excluse dar aprinderea nu porneste). cati sau reglati in afara domeniului.

necesar refaceti reglajele. 6. Daca nu reusiti sa eliminati eroarea cereti asistenta de la personal service autorizat. daca este necesar completati si apoi resetati termostatul, apasand butonul Apoi resetati alarma si porniti din nou aprinderea cazanului . 1.1. Daca dupa eliminarea cauzei nu puteti apasa butonul de resetare cereti asistenta de la personal service autorizat. 1.2. Daca dupa apasarea butonului deresetare eroarea persista, cereti asisten -ta de la personal service autorizat.

Alarma: Termostat de siguranta

1. Lipsa apa in sistemul de incalzire centrala

Apare in cazul supraincalzirii apei.

Alarma: Eroare de sistem

1. Defect mecanic cabluri.

1. Cereti asistenta de la personal service autorizat.

COOLWEX BASIC

| 37

Probleme posibile de functionare, cauze si remedieri


Nr.
1

Descriere
Cazanul functioneaza dar nu atinge temperatura setata.

Cauza

Remediere

1. Arzator si drumuri de fum murdare. 1. Curatati arzatorul si burlanele. 2. Peleti de calitate inferioara. 3. Eroare de selectare a puterii cazanului. rea prin functia dozarea arderii. 3. Consultati fabricantul pentru solutii posibiile. 1. Curatati burlanul, veri cati cosul. 2. Corectati cantitatea de aer cu functia aer de ardere si aer de stingere 3. Montati capacul corect. patrunde in cos si inchideti toate deschiderile si reparati partile deteriorate. 5. Montai un ventilator de tiraj - cereti asistenta de la un service de cazane autorizat.

Din cazan iese fum.

1. Burlan murdar. 2. Peleti de calitate inferioara. 3. Capac inferior arzator montat incorect. 4. Cos incorect. 5. Cosul nu are tirajul corect.

Aparitie condens

1. Cauze legate de cos, peleti si conditiile de ardere.

1. Mariti temperatura de initiere a pornirii pompei de circulare pana la disparitia condensului (max. pana la 60C).

1. Deschideti robinetele de izolare. Cazanul atinge tempera- 1. Robinete de izolare inchise. tura setata dar radiatoarele 2. Rotiti pompa cu un tirbuson sau 2. Dupa o perioada lunga de rapaus nu se incalzesc. pompa de circulare blocata sau defecta. 3. Temperatura de pornire a pompei reglata gresit.

temp. setata de incalzire).

38 |

Manual de utilizare

Afumarea frecventa a cazanului.

1. Peleti de calitate inferioara (determi- 1. Mariti aerul de ardere cu 1 % 3% fata de setarea existenta. 1. Corectati reglarea aer de ardere.

In cenusa este prezenta o 1. Surplus de aer de ardere. anumita cantitate de peleti nearsi. Cazanul se opreste si ecranul se stinge.

1. Eroare alimentare electrica. 2. Siguranta de 10 A de pe placa electronica arsa. 2. Inlocuiti siguranta cu una originala. 2.1. In caz ca siguranta se arde din nou cereti asistenta de la personal service autorizat.

Ecranul este aprins dar cazanul nu raspunde la comanda de aprindere.

1. Intrare telefon.

1. Daca dispozitivul nu este montat functia trebuie setata pe blocked pentru a permite functionarea cazanului. 2.Daca termostatul nu este montat functia trebuie setata pe blocked pentru a permite functionarea cazanului. Daca este conectat termostatul consultati instructiunile acestuia pentru rezolvarea problemei. 1. Contactati fabricantul sau distribuitorul de peleti. 1. Contactati fabricantul sau distribuitorul de peleti. 1. Contactati fabricantul sau distribuitorul de peleti.

2. Intrare termostat.

10

Probleme de functionare datorita acumularilor excesive de zgura in arzator.

1. Peleti de calitate foarte proasta.

11

Probleme de functionare datorita acumularilor excesive de cenusa.

1. Peleti de calitate foarte proasta.

Consum crescut excesiv de 1. Peleti de calitate foarte proasta cu putere calorica redusa. peleti (neprovocat de scaderea majora a tempe2. Cantitate mare de praf in peleti. raturii exterioare).

COOLWEX BASIC

Note: ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________

Importator: SC AGENT TRADE SRL Sos. de centura, nr. 32, 77180 Tunari, Ilfov Tel. +4021-266.51.31; +4021-266.51.32 Fax +4021-266.51.33

S-ar putea să vă placă și