Sunteți pe pagina 1din 35

UNIVERSITATEA VASILE ALECSANDRI DIN BACU

FACULTATEA de INGINERIE
MASTER UNIVERSITAR
ECHIPAMENTE I TEHNOLOGII MODERNE N ENERGETIC

BILANUL
TERMOENERGETIC I
EXERGETIC AL UNUI CET

PROIECT

Coordonator,
Prof.dr.ing. ANETA HAZI

BACU 2016

Masterand,
Rusu Ioana Viorica

CUPRINS
1.

BILAN TERMOENERGETIC I EXERGETIC CAZAN DE ABUR ..................... 6


1.3.

1.1. Descrierea cazanului........................................................................................... 6

1.4.

1.2. Bilan termoenergetic ......................................................................................... 7

1.2.1.Caracteristici combustibil....................................................................................... 7
1.2.2. Date msurate ....................................................................................................... 10
1.2.3. Mrimi calculate ................................................................................................... 12
1.2.4.
2.

Bilan termoenergetic ....................................................................................... 14

BILAN TERMOENERGETIC I EXERGETIC TURBIN DE ABUR ............. 18


2.3.

2.1. Descrierea turbinei ........................................................................................... 18

2.4.

2.2. Bilan termoenergetic ....................................................................................... 18

2.2.1. Date msurate ....................................................................................................... 19


2.2.2. Mrimi calculate ................................................................................................... 20
2.3.3. Bilan termoenergetic ........................................................................................... 23
2.5.

2.3. Bilan exergetic ................................................................................................. 24

2.3.1. Mrimi calculate ................................................................................................... 24


2.3.2.Bilan exergetic ...................................................................................................... 25
3.

BILAN TERMOENERGETIC I EXERGETIC CIRCUIT TERMIC ................. 26


3.1.

Descrierea circuitului termic .................................................................................. 26

3.2.

Bilan termoenergetic i exergetic schimbtoare de cldur ............................... 27

3.2.1.

Bilan termoenergetic ....................................................................................... 27

3.2.2.

Bilan exergetic ................................................................................................. 28

3.2.3. Indici de calitate ................................................................................................... 28


3.3.

Bilan termoenergetic i exergetic circuit termic .................................................. 32

3.3.1.

Bilan termoenergetic ....................................................................................... 32

3.3.2.

Bilan exergetic ................................................................................................. 33

4. Stabilirea soluiilor optime de economisire a combustibilului n CET ......................... 34


BIBLIOGRAFIE .................................................................................................................... 36

TEMA DE PROIECTARE
S se realizeze bilanul termoenergetic i exergetic al unui CET care are schema termic din
figura 1 i este caracterizat prin urmtoarele date iniiale:
- puterea electric la bornele generatorului: 50 MW
-

debit nominal de abur: 420 t/h


parametrii aburului viu la ieirea din cazan: presiunea 137 bar; temperatura 540 0C
presiunea aburului la priza industrial: 10-16 bar
presiunea aburului la priza de termoficare: 0,7-2,5 bar
numrul de prenclzitoare regenerative: 4 PJP i 3 PIP
boilerul de baz: presiunea maxim a aburului: 2,5 bar, presiunea maxim a apei:
17 bar
- boilerul de vrf: presiunea maxim a aburului: 21 bar, temperatur apa n evi:
1500C
Bilanul se va realiza pentru cazan, turbin, prenczitoare, boilere i pentru circuitul termic.

Fig.1 Schema simplificat CET

Fig.2 Diagrama T-s

1. BILAN TERMOENERGETIC I EXERGETIC CAZAN


DE ABUR
1.3.

1.1. Descrierea cazanului

n CET este n funciune un cazan de abur CRG1870, cu circulaie natural avnd


urmtorii parametri nominali:
- debit nominal de abur: 420 t/h
- presiunea nominal a aburului viu: 137 bar
- temperatura nominal a aburului viu: 540 0C
- presiunea nominal a apei de alimentare la intrarea n economizor: 158 bar
- temperatura nominal a apei de alimentare la intrarea n economizor: 230 0C
- randamentul termic al cazanului la sarcina nominal la temperatura mediului
ambiant de 20 0C, la funcionarea pe lignit: 85%.
Cazanul poate funciona prin arderea combinat a urmtorilor combustibili: lignit,
pcur i gaze naturale.
n fig.1 este prezentat circuitul termic si in fig.2- procesele termice de transformare a
apei n abur supranclzit n diagrama T-s. De la presiunea din condensator p=0,01 bar
(punctul 1 de funcionare), condensului principal i este mrit presiunea pn la valoarea de
10 bar (corespunztor punctului 2 de pe diagram) dup care are loc o cretere de temperatur
n rcitoarele ejectoarelor 1 i 2 i prenclzitoarele de joas presiune PJP 1...4 de la 300C la
1600C pe traseul condensator-degazorul de 6 bar, corespunztor poziiei 3 din diagrama T-s.
Dup degazor, presiunea apei de alimentare crete de la 6 bar la 158 bar n electropompa de
alimentare (curba 3-4) i o cretere de temperatur n prenclzitoarele de nalt presiune PIP
5...7, pn la valoarea de intrare n cazan de 2300C. Apa parcurge economizorul E compus din
trei pachete succesive a, b, c i aflat n drumul II de gaze, nainte de intrarea gazelor n
prenclzitoarele de aer.
Are loc nclzirea apei de alimentare cu ajutorul gazelor de ardere, temperatura la
ieirea din economizor atingnd o valoare apropiat de temperatura de saturaie,
corespunztor punctului 5 din diagrama T-s. n aceast stare apa ptrunde pe traseul tamburvaporizator-tambur, unde are loc creterea coninutului de abur n ap de la titlul x=0
corespunztor curbei de lichid saturat, la titlul x=1 n punctul 6, aflat pe curba de lichid
saturat. n aceast stare de saturaie aburul colectat n tambur prsete vaporizatorul i este
supranclzit n peretele plafon i spate drum II al cazanului, pereii laterali ai drumului II, evi
susinere drum II, supranclzitorul I, supranclzitorul II i supranclzitorul III i IV, toate
aceste suprafee de schimb de cldur fiind nseriate. n final temperatura aburului viu ajunge
la 5400C. ntre supranclzitoarele I i II i supranclzitoarele II i III i IV se fac injecii cu
apa de alimentare pentru reglarea temperaturii.
Cu starea punctului 7 aburul viu intr n corpul de nalt presiune al turbinei (CIP) i
apoi n corpul de medie-joas presiune (CMP-CJP) i se destinde pe adiabata 7-8.

1.4.

1.2. Bilan termoenergetic


1.2.1.Caracteristici

combustibil
1.2.3.1.

1.2.1.1. Gaz

metan
Compozitia chimica a gazului metan
%
Hi kJ/mc
Hi*%

O2
0,2
0
0

N2
1,6
0
0

CO2
0
0
0

C5H12
0
145840
0

CH4
98,2
33678
33072

1.2.1.1.1. Puterea calorifica inferioara


Pres.barometrica
mmHg
743
Putere calorifica a gazului metan, corectata in functie de presiunea barometrica este:
[1]
Hi=Sum(Hi*%)*pB/760
Hi=
32350 kJ/Nmc

7739

kcal/Nmc

1.2.1.1.2. Aerul necesar arderii


Calculul aerului necesar arderii
[2] min.O = 0.01*(2*CH4+5*C3H8+8*C5H12+6.5*C4H10-O2)
[3] min.L = min.O/0.21
[Nm3/m3 gaz] - aerul

[Nm3/m3 gaz]

- oxigenul

1.2.1.1.3. Volumul gazelor de ardere


Volumul teoretic al gazelor de ardere :
[4] VCO2 = 0.01*(CO2+CH4+3*C3H8+5*C5H12+4*C4H10) [Nm3/m3 gaz]
[5] VN2 = 0.01*N2+0.79*min.L
[Nm3/m3 gaz]
[6] VH2O = 0.01*(2*CH4+4*C3H8+6*C5H12+5*C4H10)+0.0161*min.L
[Nm3/m3 gaz]

C4H10
0
123352
0

C3H8
0
93423
0

C4H10B
0
121429
0

CO
12624
33072

Volumul real al gazelor de ardere :


[7] Vg = VCO2+VN2+VH2O+1.00161*(n-1)*min.L
[8] Vaer = Vg-VCO2-VN2-VH2O [Nm3/m3 gaz]
SumV = VCO2+VN2+VH2O
min.O
min.L
1.962
9.343

VCO2
0.982

VN2
7.397

VH2O
2.114

SumV
10.493

1.2.1.2. Crbune
Compozitia chimica a carbunelui
O2
N2
%
8
0,77

C
15,53

H
1,62

S
1,08

A
41,4

W
31,6

1.2.1.2.1. Puterea calorifica inferioara


[9]

Hip = [335*C + 1030*H + 109*(S-O) - 25.1*W] [kJ/kg]


Hip =
5324 [kJ/kg]

1.2.1.2.2. Aerul necesar arderii


[10]
[11]

min.O'= 0.01*(1.867*C+5.6*H+0.7*S-0.7*O2) [Nm3/kg]


min.L'=1.016*min.O'/0.21
[Nm3/kg]

1.2.1.2.3. Volumul gazelor de ardere


Volumul teoretic al gazelor de ardere :
[12]
VCO2' = 1.867*C*0.01
[Nm3/kg]
[13]
VSO2' = 0.7*S*0.01
[Nm3/kg]
[14]
VRO2 = VCO2'+VSO2'
[Nm3/kg]
vol.gaze de ardere triatomice uscate
[15]
VN2' = 0.79*min.L' + 0.8*N*0.01 [Nm3/kg]
vol.teoretic de azot
VH2O' = 11.2*H*0.01 +1.242*W*0.01 + 0.00161*x*n*min.L' [Nm3/kg] vol.teoretic vapori de apa
[16]
[17]
Sum V'=VRO2+VN2'+VH2O'
[Nm3/kg] vol.teoretic gaz.de ardere
x = 10
[g/kg aer uscat] umid.aer
Volumul real al gazelor de ardere :
[18]
Vgu' = VRO2+VN2+(n-1)*min.L

[Nm3/kg]

vol.real al gaz.de ardere uscate

[19]
[20]
[21]
min.O'
0.332

Vg'*=VRO2+VN2+11.2*H*0.01+1.242*W*0,01
[Nm3/kg]
Vg'=Vgu'+VH2O=Vg'* +(n-1)*min.L'+0.0016*x*n*min.L' [Nm3/kg]
Vaer'=Vg'-Sum V' [Nm3/kg]
Vol.real de aer
min.L'
1.607

VCO2'
0.29

VSO2'
0.008

VRO2
0.298

VN2
1.276

VH2O'
0.651

vol.real de gaz.de ardere

Vgu'
4.474

Vg*
2.147

Vg'
5.391

Sum V'
2.224

Vaer'
3.166

1.2.2. Date msurate


Bilanul termoenergetic real pentru cazane se efectueaz pentru patru debite ale
cazanului i anume:
- debitul minim (debitul minim cu care poate funciona cazanul timp nedefinit fr a
suferi stricciuni);
- debitul normal (debitul corespunztor funcionrii cazanului cu randament optim;
acesta este aproximativ 80% din debitul nominal);
- debitul nominal (debitul maxim continuu de abur pe care cazanul trebuie s-l
asigure n timpul unei exploatri permanente);
- debitul mediu anual (debitul rezultat din raportul produciei anuale de abur la
numrul de ore de funcionare al cazanului)
Durata msurtorilor termotehnice pentru fiecare sarcin va fi de cel puin 4 h dup
atingerea strii de echilibru termic. Cazanul supus msurtorilor trebuie s fi fost pus n
funciune cu cel puin 48 h naintea nceperii ncercrilor. Echilibrul termic se consider atins
dac s-a meninut sarcina la care urmeaz s aib loc proba, cel puin 2-3 h naintea nceperii
msurtorilor.
n timpul unei ncercri, valoarea parametrilor pentru care se face msurarea nu
trebuie s depeasc 15% pentru debit i 7% pentru presiune.
Intervalul de timp pentru citiri se va alege astfel nct s poat cuprinde cu o siguran
suficient variaiile valorilor msurate. Se recomand urmtoarele frecvene de msurare i
nregistrare:
- debitele cu manometru diferenial: din 3 n 3 min;
- presiunile i temperaturile: din 15 n 15 min;
- indicaiile date de analizoarele automate de gaz: din 15 n 15 min;
- preluarea probelor de gaze de ardere pentru analiza chimic cu aparate tip Orsat:
din 30 n 30 min.
Citirile tuturor indicaiilor aparatelor la nceputul i sfritul ncercrii se vor face simultan.
Valorile de stare ale atmosferei (presiunea barometric, umiditatea aerului, etc.) se vor citi
naintea nceperii ncercrilor.
Dup efectuarea tuturor msurtorilor se vor face mediile pentru fiecare msurare la
fiecare ncercare.
n acest proiect se realizeaz bilanul pentru un singur regim de functionare.

10

COMBUSTIBIL
Denumire
Debit carbune
Putere calorifica inferioara
Debit gaz metan
Putere calorifica inferioara
Debit zgura uscata, inclusiv nearse
Putere calorifica zgura
Nearse in zgura
Nearse in cenusa
Putere calorifica nearse cenusa
Temp.carbune intrare cazan (ind./inreg)

Simbol
Bc
Hic
B
Hi
Bzg
Hizg
pzg
pcen
Hicen
tc

U.M.
t/h
kJ/kg
Nmc/h
kJ/Nmc
t/h
kJ/kg
%
%
kJ/kg
C

Valoare
148
4945
4015
35018
4
28533
10,52
0,22
29308
160

Mod de masurare

Simbol
Dab
pab
tab
Da
pa
ta
Dpj

U.M.
t/h
bar
C
t/h
bar
C
t/h
bar

Valoare
273
130
540
285
167
227
12
143

Debitmetru diferenial
manometru
termorezisten
Debitmetru diferenial
manometru
termorezisten
Carte tehnic cazan
manometru

Simbol
taer0

U.M.
C
C
C
C
C

Valoare
-9
2
3
324
-9

Termometru sticl
termorezisten
termorezisten
termorezisten
Termometru sticl

U.M.

Valoare
1,3

diagrama Ostwald

6
14,1
0,0067
2,97
150
0,4

analiza gaze arse


analiza gaze arse
diagrama Ostwald
diagrama Ostwald
termorezisten
Aproximare literatur

cntar
buletin
Debitmetru diferenial
buletin
cntar
Bomba calorimetric
Aproximare literatur
Aproximare literatur
literatur
termorezisten

APA-ABUR
Denumire
Debit abur supraincalzit
Presiune abur supraincalzit
Temp.abur supraincalzit
Debit apa alimentare
Presiune apa alimentare
Temp.apa alim
Debit purja
Presiune tambur
AER
Denumire
Temp. aspiratie VA1/VA2
Temp.inainte de calorifer st/dr
Temp.dupa calorifer C1/C2
Temp.dupa PAR1/PAR2
Temp.mediu ambiant

taer
tmed

GAZE DE ARDERE
Denumire
Coeficient exces de aer in focar
Analiza gaze ardere la VG1/VG2
CO2
O2
CO
Coeficient exces de aer dupa VG1/VG2
Temp.la cos
Coeficient pierderi prin radiatie

Simbol
nf

%
%
%
n
tg
qr

C
%

Clduri specifice gaze, kJ/(mc C)


csCO2
1,7

csSO2
1,5

csH2O
1,5

csN2
1,29

csAer
1,32

11

1.2.3. Mrimi calculate


Bilantul se efectueaza prin metoda directa.
Fluxul de cldur total introdus n cazan are trei purttori materiali:
- combustibilul solid (lignit) i gazos, de debit Bc [t/h], respectiv Bg [Nm3/h] i
puteri calorifice Hi,c, [kJ/kg], respectiv Hi [kJ/Nm3]. Crbunele se introduce n
cazan la temperaturile tc [0C];
- aerul de combustie de volum stoechiometric Vaer [Nm3/kg];
- apa de alimentare de debit Da Dab D pj [t/h] i temperatura ta [0C].
Fluxul de cldur fizic a crbunelui introdus n focar este:
[kW]
(1)
Qcf Bc cc t c / 3.6
Fluxul de cldur eliberat de combustibil prin ardere:
Qcc Qcg Bc H i,c / 3.6 B g H i / 3600

[kW]

Fluxul de cldur introdus cu combustibilul in cazan este:


Qc Qcc Qcg Qcf
[kW]
Fluxul de cldur fizic a aerului introdus n cazan la temperatura taer:
Qaer ( Bc L'1 f / 3600 B g L1 f / 3.6).i aer,i
[kW]
Fluxul de cldur introdus cu apa de alimentare:
Qa Da i a / 3.6

[kW]

(2)
(3)
(4)
(5)

Fluxul de cldur al aburului care prsete cazanul se poate calcula cu formula:


(6)
Qab Dab i ab / 3.6 [kW]
unde iab este entalpia aburului, in kJ/kg.
Fluxul de cldur al purjei evacuate din cazan:
Q pj D pj i pj / 3.6
[kW]
(7)
Fluxul de cldur util preluat de agentul termic n cazan este:
Qu Qab Qa Q pj
[kW]
(8)
Se definesc urmtorii indici specifici:
- randamentul termodinamic brut al cazanului, cb:
Q
cb u 100
[%]
(9)
Qc
- randamentul de exploatare, ce:
Qu
ce
100
[%]
(10)
Qc Qaer
- consumul specific de cldur:
1
[kJ/kJ]
(11)
csq

cb

consumul specific de combustibil conventional:


csq
csc
1000
[gcc/kJ]
H icc

(12)

Elementele bilanului energetic realizat prin metoda direct sunt prezentate n


continuare. Calculul a fost realizat pentru un regim stabilizat de funcionare al cazanului cu
funcionare pe crbune cu susinere pe gaz.

12

1.2.3.2.

Proprieti fizice ap, abur, aer, gaze de ardere. Debite aer, gaze,

combustibil
Denumire
entalpie abur
entropie abur
entalpie apa alim.
entropie apa
entalpie purja
entropie purja
ent. aer dupa cal.
cald.spec.carbune
debit carbune
debit gaz metan
coef.comb(Bg/Bc)
ent CO2,SO2 la tg
entalpie N2 la tg
entalpie H2O la tg
entalpie aer la tg
entalpie gaze ard.
entalpie gaze ard.
entalpie gaze ard.
debit aer ard.gaz
debit aer ard. carbune
vol.gaze de ard.gaz
vol.aer in g.a.gaz
vol.gaze de ard.carb.
coef.comb(Bg/Bc)
vol.tot.gaz.ard.
vol.vap.apa carb.
vol.aer in g.a.carb.

1.2.3.3.
Denumire
cald.sensibila carbune
cald.chimica carbune
cald.chimica gaz
cald.comb.total
cald.apa alim.
cald.aer ardere
cald.intrata
caldura gaze ard.
cald.prin nearse CO
cald.nearse
cenusa,zgura
cald.fizica zgura
cald.prin radiatie
cald.livr. cu abur
cald purja
caldura iesita
caldura utila
caldura consumata

Simbol
iab
sab
ia
sa
ipj
spj
iaeri
cc
Bc
Bg
m
iCO2
iN2
iH2O
iaer
igg
igc
ig
L1f
L1f'
Vg
Vaer
Vg'
m
VG
VH2O'
Vaer'

U.M.
kJ/kg
kJ/kgC
kJ/kg
kJ/kgC
kJ/kg
kJ/kgC
kJ/mc
kJ/kg
kg/s
Nmc/s
mc/kg
kJ/mc
kJ/mc
kJ/mc
kJ/mc
kJ/mc
kJ/kg
kJ/kg
mc/Nmc
mc/kg
Nmc/Nmc
Nmc/Nmc
Nmc/kg
mc/kg
Nmc/s
Nmc/kg
Nmc/kg

Valoare
3443.94
6.572
979.739
2.556
2627.97
5.348
3.96
1
41.11
1.115
0.0271
255
193.5
225
198
1094.289
1096.329
1126.007709
2.089
12.146
28.9283
18.435
5.390
0.0271
253.846
2.165
3.165

Mod de calcul
tab f(tab, pab)
tab f(tab,pab)
tab f(ta)
tab f(ta)
tab-abur la temp.sat la pres.tambur
tab-abur la temp.sat la pres.tambur
csAer . taer
tab

Valoare
6577.76
203293.895
39045.07
248916.725
77562.67083
1986.541154
328465.937
46291.30291
214.705085

Mod de calcul
Bc*cc*tc
Bc*Hic
Bg*Hi
Qcc+Qcg+Qcf
Da*ia/3,6
(Bc*L1f '+Bg*L1f')*iaeri
Qct+Qa+Qaer
Bg*igg+Bc*igc
VG*CO*HiCO*0.01

Bg/Bc
csCO2 . tg
csN2 . tg
csH2O . tg
csAer . tg
iCO2*VCO2+iN2*VN2+iH2O*VH2O+iaer*Vaer
iCO2*VRO2+iN2*VN2+iH2O*VH2O'+iaer*Vaer'
igc+m*igg
nf*min.L
nf*min.L'
SumV+1.00161*(n-1)*min.L
Vg-VCO2-VN2-VH2O =1.00161*(n-1)*min.L
(Vg'*) + (n-1)*min.L'+ 0.0016* x * min.L'*n
Bg/Bc
Vg'*Bc+Vg*Bg
VH2O'+(n-1)*0.00161*x*min.L'
Vg'-(VH2O'+VRO2+VN2)

Fluxuri de cldur
Simbol
Qcf
Qcc
Qcg
Qct
Qa
Qaer
Qi
Qg
Qco

U.M.
kW
kW
kW
kW
kW
kW
kW
kW
kW

Qcen
Qzg
Qr
Qab
Qpj
Qe
Qu
Qc

kW
kW
kW
kW
kW
kW
kW
kW

3497.421333
31703.33333
1313.863748
261165.45
8760
352946
192363
242338.965

13

Bzg/3,6*(pzg+pcen)*0,01*Hicen
Bzg/3,6*Hizg
qr*Qi/100
Dab*iab/3,6
Dpj*ipj/3,6
Qg+Qco+Qr+Qab+Qpj+Qcen+Qzg
Qab-Qa+Qpj
Qcc+Qcg

1.2.3.4.

1.2.3.3. Indici energetici

Denumire
rand.termic brut
rand.de exploatare

Simbol
rcb
rce

cons.sp.de caldura

csq

U.M.
%
%
kJ comb/kJ
ab

cons.sp. comb.conv.
cons.comb.conv.

csc
Bcc

gcc/kJ ab
kgcc/s

Valoare
79.37752774
78.73213165
0.012598024
0.000430451
8.28028035

1.2.4. Bilan termoenergetic

Denumire

Valoare, kW

Qcf
Qc
Qa
Qaer
TOTAL INTRARE - Qi
Qg
Qco
Qzg
Qcen
Qr
Qab
Qpj
TOTAL IESIRE - Qe
Eroare inchidere

6577.76
242338.965
77562.671
1986.541
328465.937
46291.30291
214.705085
31703.33333
3497.421333
1313.863748
261165.45
8759.9
352945.9764
24480.03942

2.002569904
73.77902477
23.61361167
0.604793657
100
14.09318218
0.065366012
9.651939444
1.064774438
0.4
79.51066476
2.666912764
107.4528396
6.935916842

14

Mod de calcul
100*Qu/Qc
Qu*100/(Qc+Qaer)
1/rcb
csq*1000/Hicc Hicc=29267kJ/kgcc pt.comb.conv.
Qu/(rcb*0,01*Hicc)

1.3. Bilan exergetic


1.3.1. Mrimi calculate
Bilanul exergetic se realizeaz pentru acelai regim de funcionare ca i bilanul
termoenergetic.
Exergia specific (e) a agentului secundar ap-abur ce evolueaz n instalaie este dat
de relaia:
e i i0 T0 s s0

[kJ/kg]

(13)

Exergiile fluidului de lucru n punctele caracteristice se calculeaz cu relaia:


E De

[kW]

(14)

Componentele bilanului exergetic al instalaiei sunt:


- exergia chimic a combustibilului
- exergiile fizice ale aerului i combustibilului;
- exergia agentului termic obinut (abur);
- exergia apei de alimentare;
- pierdere exergetice.
Exergia chimic specific a combustibilului se calculeaz pentru crbune cu formula:

ec H ic

[kJ/kg]

(15)

iar pentru gaz metan:

eg 0,95 H is 0.95 H ig 2509 9H W

[kJ/Nmc]

(16)

Exergia chimic a combustibilului:

Ech Ec m E g

[kW]

(17)

Exergia fizic a crbunelui:

T
Ecf 1 0 Qcf
Tc

[kW]

(18)

Exergia fizic a aerului:

T
E aer 1 0
Taer

Qaer [kW]

(19)

Exergia consumat n cazan este:


Econs Ech Ecf Eaer

[kW]

(20)

Exergia apei de alimentare:


Ea Da ia i0 T0 sa s0

[kW]

(21)

unde: ia, sa sunt entalpia apei de alimentare n kJ/kg i, respectiv, entropia apei, n kJ/kg0C la
temperatura ta a apei la intrarea n cazan ; i0, s0 sunt entalpia apei de alimentare n kJ/kg i,
15

respectiv, entropia apei, n kJ/kg0C la temperatura t0 de referin pentru calculul exergetic de


20 0C.

Exergia aburului la ieire din cazan:


Eab Dab iab i0 T0 sab s0

[kW]

(22)
0

unde: iab, sab sunt entalpia aburului n kJ/kg i, respectiv, entropia aburului, n kJ/kg C la
temperatura tab a aburului la ieirea din cazan.
Exergia util este:
Eutil Eab Ea

(23)

Se definete randamentul exergetic al cazanului:

exc

Eutil
100
Econs

[%]

(24)

1.3.1.1. Exergii specifice ap, abur, aer, gaze de ardere


Denumire
Puterea calorifica superioara gaz
xergie specifica gaz
Exergie specifi a carbune
Temperatura de referinta
Temperatura carbunelui la intrare cazan
Temp.aer dupa calorifer
Entalpia spec.a apei la referinta(20C,1bar)
Entropia spec.a apei la referinta(20C,1bar)
Exergia specifica a apei de alim.
Exergia specifica a purjei
Exergia specifica a aburului

Simbol
Hs
eg
ec
T0
Tc
Taer
i0
s0
ea
epj
eab

U.M.
kJ/Nmc
kJ/Nmc
kJ/kg
K
K
K
kJ/kg
kJ/kgC
kJ/kg
kJ/kg
kJ/kg

Valoare
35018
33267.1
4945
293
433
276
84
0.296
233.53263
1063.734
1521.072

Mod de calcul
Hi+2509*(9*H+W)
0,95*Hs
Hic
273+20 (t0=20C)
273+tc
273+taer
tabele
tabele
ia- i0-To*(sa-s0)
ipj- i0-To*(spj-s0)
iab- i0-To*(sab-s0)

1.4.1.2.Fluxuri de exergie
Denumire
Exergie chimica gaz
Exergie chimica carbune
Exergie chimica combustibil
Exergia fizica a carbunelui
Exergie fizica aer
Exergie apa alim.
Exergie purja
Exergie abur iesire cazan
Exergia utila
Exergia consumata

Simbol
Eg
Ec
Ech
Ecf
Eaer
Ea
Epj
Eab
Eutil
Econs

U.M.
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW

Valoare

37092.817
203293.895
204299.9151
2126.75843
-122.3594189
18487.99988
3542.23422
115342.8898
100397.1241
206304.3141

Mod de calcul
Bg*eg
Bc*ec
Ec+m*Eg
(1-T0/Tc)*Qcf
(1-T0/Taer)*Qaer
Da*ea
Dpj*epj
Dab*eab
Eab-Ea+Epj
Ech+Ecf+Eaer

1.4.1.3.Indici exergetici
Denumire
Randament exergetic cazan

Simbol
rexc

16

U.M.
%

Valoare
48.66457813

Mod de calcul
100*Eutil/Econs

1.4.2. Bilan exergetic i diagrama Sankey


Denumire

Valoare, kW

Ecf
Ech
Ea
Eaer
TOTAL INTRAT
Eab
Epj
Pierderi exergie
TOTAL IESIT

2126.758
204299.915
18488.000
-122.359

0.946099265
90.88385251
8.224480433
-0.054432208
100
51.31086901
1.575780843
47.11335014
100

224792.314
115342.890
3542.234
105907.190
224792.314

Realiznd o paralel ntre analiza energetic i analiza exergetic, se poate sesiza


faptul c, n timp ce randamentul energetic are valoarea de 77%, randamentul exergetic are
numai 48,66%.
Se poate spune c randamentul exergetic apreciaz gradul de perfeciune
termodinamic al proceselor care se desfoar din punctul de vedere al ireversibilitilor
interne. Pentru creterea randamentului exergetic este necesar reducerea pierderilor
exergetice.
Deoarece asupra procesului de ardere nu se poate aciona, rezult c cea mai
important cale este reducerea pierderilor datorate ireversibilitilor procesului de transfer
termic prin mbuntirea schimbului de cldur i n acest sens se pot aplica urmtoarele
msuri:

curirea corespunztoare a suprafeelor;

alegerea regimului aero-gazodinamic corespunztor;

pregtirea corespunztoare a combustibililor naintea introducerii n focar, n

vederea arderii (mcinare, prenclzire, etc.);

etanare corespunztoare pe tot traseul gazelor de ardere.

Urmrirea n timp a randamentelor exergetice pentru fiecare zon poate evidenia, cu


uurin, zona n care schimbul de cldur se desfoar cu eficien redus.
Ponderea ridicat a acestor pierderi se explic prin diferena mare ntre temperatura
gazelor de ardere (1430C) i temperatura aburului produs (540C).

17

2.

BILAN TERMOENERGETIC I EXERGETIC


TURBIN DE ABUR

2.3.

2.1. Descrierea turbinei

n CET este n funciune o turbin cu abur tip DSL 50-1, care este o turbin de
condensaie cu 2 prize reglabile i 5 prize fixe. Parametrii nominali sunt:
- puterea electric la bornele generatorului: 50 MW
- turaia nominal: 3000 rot/min
- parametrii aburului viu: presiunea 130 ata; temperatura 545 0C
- presiunea aburului la priza industrial: 10-16 ata
- presiunea aburului la priza de termoficare: 0,7-2,5 ata
- presiunea aburului n condensator: 0,053 ata
- debit maxim abur la admisie: 370 t/h
- debit nominal la priza de termoficare: 86 t/h
- temperatura maxim a apei de alimentare 237 0C
Din punct de vedere constructiv turbina este de tipul cu aciune pe o singur linie de
arbore. Turbina se compune din dou corpuri: corpul de nalt presiune (CP) i corpul de
medie i joas presiune (CMP-CJP).
Aburul viu intr n turbin prin ventilul de nchidere rapid (VIR), montat n faa
turbinei, fiind legat de aceasta prin 4 conducte de nalt presiune. De la VIR aburul ajunge
prin cele 4 conducte de admisie la 4 ventile de reglare montate 4 camere de abur, montate n
partea din fa a carcasei de P.
Aburul viu se destinde n CP de la presiunea de admisie (130 ata) pn la 13 ata (la
funcionarea n regim nominal). De aici, o parte din abur este dirijat spre camera prizei
industriale, iar cealalt parte, prin 4 ventile de reglare, intr n CMP-CJP. Dup ce strbate
cele 8 trepte ale CMP, o parte din abur este extras prin priza de termoficare de 1,2 ata, iar
restul prin diafragma ce separ CMP de CJP, intr n CJP, de unde, dup destindere, ajunge n
ondensator.

2.4.

2.2. Bilan termoenergetic


Pentru o turbin de abur cu condensaie i prize reglabile conturul de bilan este:
- pe partea de abur viu racordul la VIR;
- pe partea de abur livrat la termoficare la racordul prizelor reglabile dup
bifurcaia ce alimenteaz cu abur circuitul regenerativ;
- pe partea electric la bornele generatorului;
- pe partea de ap de rcire la racordul comun de intrare i la ieirile din
condensator, rcitorul generatorului i rcitorul de ulei;
- pe partea de condens de la termoficare la racordul degazorului;
- pe partea de ap de adaos la prenclzitor.
Regimurile caracteristice pentru bilan sunt:
18

regim de condensaie maxim, cu prizele reglabile nchise i puterea de la bornele


generatorului ct mai apropiat de cea nominal;

regimul de termoficare maxim, cu debit maxim de abur la admisie i debit mic de


abur n condensaie;
regim de putere electric maxim, cu debite maxime prin toate regiunile turbinei i
debit limitat la prizele reglabile.

2.2.1. Date msurate


Putere la borne generator
Debit abur viu
Debit apa alim iesire PIP7
Debit condes.de baza iesire
PJP4
Debit cond.de baza
ies.condensator
Debit cond.sec iesire BB
Debit cond.sec ies BV
Debit apa retea intrare BB
Pres ab viu intr.
Pres abur.dupa CIP
Pres.ab.priza 10-16 ata
Temp.ab.viu intr.turb.
Temp.ab.esapare CIP
Temp.abur priza 16
Debit abur priza 16
Pres.abur priza 1,2
Temp.ab.priza 1,2
Pres ab.esapare CIP
Pres.absoluta condensator
Temp.CDB ies.condensator
Debit apa racire intrare cond.
Temp.apa racire intr.cond.
ies.cond.
Temp.ulei turbina intr racitor
ies rac
Racitor hidrog.gen. Intr.R1
ies R1
Temp.buraj (esapare)
Pres.ab DG6
Pres.ab DG1,2
Pres.ab.intr.BB
Pres.apa retea intrare BB
Pres.ab.intr. PJP2
PJP3
PJP4
PIP5
PIP6
PIP7
Temp.ab.intr.PJP2
PJP3
PJP4
PIP5

Pbg
Do

MW
t/h
t/h

48
273
306

t/h

po

t5'
p2'
t2'
pes
pa,VIII
tVIII
ta,c1
ta,c2
tu1
tu2
th1
th2
tes
pdg6
pdg1
p2'
pabb1
p2
p3
p4
p5
p6
p7
t3
t4
t5

60

t/h
t/h
t/h
t/h
bar
bar
bar
C
C
C
t/h
bar
C
bar
bara
mc/h
C
C
C
C
C
C
C
bar
bar
bar
bar
bar
bar
bar
bar
bar
bar
C
C
C
C

19

55
118
12,3
2450
129
75
11
530
253
265
68
1,3
125
11,8
0,073
38
2624
16
30
55
44
45
39
44
3,9
0,3
0,15
12,5
0,3
2,4
2,5
10,7
18,4
26,0
108
156
191
304

PIP6
PIP7
Temp.cond
intr.PJP1
ies.PJP1
intr.PJP2
intr.PJP3
intrPJP4
ies.PJP4
Temp.apa alim intr PIP5
intr.PIP6
intrPIP7
iesPIP7
Temp.apa retea retur termof.
iesi BB
intr BV
ies BV

t6
t7
tc11
tc12
tc21
tc31
tc41
tc42
ta51
ta61
ta71
ta72
tabb1
tabb2
tabv1
tabv2

C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C

320
381
53
53
90
100
129
135
160
180
205
232
59
81
81
91

Temp.abur intr.BV
Temp.cond.sec ies.BB
ies.BV
Temp.cond.sec.iesire PIP5
ies.PJP4
Ies. PJP3
ies.PJP2

t5'
tc5
tc2
tc5
tcs4
tcs3
tcs2

C
C
C
C
C
C
C

304
105
187
180,3
135
108
105

SRR 13/6 pres.


temp

bar
C

6
228

2.2.2. Mrimi calculate


Ecuaia bilanului energetic este:
Pta 0 Pbg Ptap Ptcd DPmec DPgen DPdiv

(25)

unde: Pta0 [kW] fluxul de cldur intrat cu aburul viu;

Pta 0 D0 i0t [kW]

(26)

unde: D0 [kg/s] debitul de abur la intrarea n turbin; i0t [kJ/kg] entalpia aburului la
intrarea n turbin.
Pbg [kW] fluxul de energie electric (puterea la bornele generatorului);
m , g randamentul mecanic al turbinei, respectiv, randamentul generatorului electric.
Ptap [kW] fluxul de cldur evacuat la prize:
7

Ptap D pri ii

(27)

i 1

Ptcd fluxul de cldur cedat de aburul ce condenseaz n condensator:

Ptcd Dcd ie icd

(28)

unde: Dcd debitul de abur in condensator; ie, icd entalpia aburului la intrare, respectiv, a
condensului la ieirea din condensator.
DPmec pierderile prin frecri mecanice, DPgen pierderile generatorului; DPpiv eroarea de
nchidere a bilanului i pierderi diverse (radiaie, convecie spre mediul ambiant, scpri de
abur la labirini);
20

Ecuaia bilanului material este:


7

D0 Dcd D pri Dsc

(29)

i 1

unde: Dsc debit de abur de scpri la tija VIR, labirini.


Randamentul intern pe ansamblul turbinei este:

i0 ie
i0 iet

(30)

unde: iet [kJ/kg] entalpia teoretic a aburului la ieirea din turbin.


Randamentul intern se determin i pe treptele turbinei cu o relaie de forma (30).
Rezultatele analizei energetice a turbinei DSL 50-1 din CET-Bacu sunt prezentate n
continuare.
Denumire
Entalpie abur viu
Entropie abur viu
Ental.teoret.abur pr.7
Entalpie abur pr.7
Entropie abur pr.7
Ental.teoret.abur pr.6
Entalpie abur pr.6
Entropie abur pr.6
Ental.teoret.abur pr.5
Entalpie abur pr.5
Entropie abur pr.5
Ental.teoret.abur pr.4
Entalpie abur pr.4
Entropie abur pr.4
Ental.teoret.abur pr.3
Entalpie abur pr.3
Entropie abur pr.3
Ental.teoret.abur pr.2
Entalpie abur pr.2
Entropie abur pr.2
Ental.teoret.abur pr.1
Entalpie abur pr.1
Entropie abur pr.1
Cadere reala ent.pr.7
Cadere teor.ent.pr.7
Cadere reala ent.pr.6
Cadere teor.ent.pr.6
Cadere reala ent.pr.5
Cadere teor.ent.pr.5
Cadere reala ent.pr.4
Cadere teor.ent.pr.4
Cadere reala ent.pr.3
Cadere teor.ent.pr.3
Cadere reala ent.pr.2
Cadere teor.ent.pr.2
Cadere reala ent.pr.1
Cadere teor.ent.pr.1

Simbol

U.M.

Valoarea

Mod de calcul

i0t
s0t
i7t
i7
s7
i6t
i6
s6
i5t
i5
s5
i4t
i4
s4
i3t
i3
s3
i2t
i2
s2
i1t
i1
s1
Hi7
Ht7
Hi6
Ht6
Hi5
Ht5
Hi4
Ht4
Hi3
Ht3
Hi2
Ht2
Hi1
Ht1

kj/kg
kj/kgC
kj/kg
kj/kg
kj/kgC
kj/kg
kj/kg
kj/kgC
kj/kg
kj/kg
kj/kgC
kj/kg
kj/kg
kj/kgC
kj/kg
kj/kg
kj/kgC
kj/kg
kj/kg
kj/kgC
kj/kg
kj/kg
kj/kgC
kj/kg
kj/kg
kj/kg
kj/kg
kj/kg
kj/kg
kj/kg
kj/kg
kj/kg
kj/kg
kj/kg
kj/kg
kj/kg
kj/kg

3418.47
6.5437
2970.38
3193.73
6.913
3101.5
3071.61
6.863
2946.37
3055.79
7.061
2783.12
2844.7
7.198
2838.62
2771.01
7.046
2601.14
2688.52
7.2758
2794.11
2713.34
7.082
224.74
448.09
346.86
316.97
362.68
472.1
573.77
635.35
647.46
579.85
729.95
817.33
705.13
624.36

f(pot,tot)
f(pot,tot)
f(p7,sot)
f(p7,t7)
f(p7,t7)
f(p6,s7)
f(p6,t6)
f(p6,t6)
f(p5,s6)
f(p5,t5)
f(p5,t5)
f(p4,s5)
f(p4,t4)
f(p4,t4)
f(p3,s4)
f(p3,t3)
f(p3,t3)
f(p2,s3)
f(p2,t2)
f(p2,t2)
f(p1,s2)
f(p1,t1)
f(p1,t1)
iot-i7
iot-i7t

21

Rand.intern priza 7
Rand.intern priza 6
Rand.intern priza 5
Rand.intern priza 4
Rand.intern priza 3
Rand.intern priza 2
Rand.intern priza 1
Entalpie abur cond.
Entropie ab.cond.
Entalpie cond. cond.
Entropie cond.cond.

ni7
ni6
ni5
ni4
ni3
ni2
ni1
iacd
sacd
icd
scd

%
%
%
%
%
%
%
kj/kg
kj/kgC
kj/kg
kj/kgC

Titlu abur
Ental. teor.ies.turb.cond
Ent.real.ies.turb.cond
Titlu real
Entr.real.ies.turb.cond
Cadere reala ent.pr.cd
Cadere teor.ent.pr.cd
Rand.intern cond
Putere term. abur viu
Debit abur intr.turbina
Debit abur priza 7
Debit abur priza 6
Debit abur priza 5
Debit abur priza 4
Debit abur priza 3
Debit abur priza 2
Debit abur priza 1
Total abur prize
Scapari abur
Debit abur intr.cond.
Debit cond.returnat
Putere term.la priza 7
Putere term.la priza 6
Putere term.la priza 5
Putere term.la priza 4
Putere term.la priza 3
Putere term.la priza 2
Putere term.la priza 1
Total putere term.prize
Putere term.la cond
Pierderi in gen.
Pierderi mecanice
Puterea interna

x
iet
ie
xr
se
Hicd
Htcd
nicd
Ptao
Do
Dpr7
Dpr6
Dpr5
Dpr4
Dpr3
Dpr2
Dpr1
Dp
Dsc
Dcd
Dcdr
Pta7
Pta6
Pta5
Pta4
Pta3
Pta2
Pta1
Ptt
Ptcd
DPgen
DPmec
Pi

kj/kgC
kj/kg
kj/kg
%
kW
kg/s
kg/s
kg/s
kg/s
kg/s
kg/s
kg/s
kg/s
kg/s
kg/s
kg/s
kg/s
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW

Pierderi diverse
Putere term.cond.ret.
Randament generator

DPdiv
Pcdr
rg

kW
kW
%

Randament mecanic
Randament intern tot

rm
ri

%
%

kj/kg
kj/kg

22

50.15510277
109.4299145
76.82270705
90.30770441
111.659912
89.3090918
112.9364469
2572
8.264
166.6
0.569
0.87
2263.000
2441.000
0.95
7.845
245.00
423.000
57.91962175
259233.975
75.83333333
5,33
4,68
18,89
0,21
1,04
30,43
0
60,59
0,76
14,49
47,67
17022.5809
14375.1348
57723.8731
597.387
2881.8504
81811.6636
0
174412.4898
35370.090
400
400
48800
651.3952
2545.277778
99.17355372
99.18032787
84.59501328

100*Hi7/Ht7

la sat.la pres.in cond.


la sat.la pres.in cond.
la sat.la pres.in cond.
la sat.la pres.in cond.
(s2-scd)/(sacd-scd)
(1-x)*icd+x*iacd
i2-ri2(i2-iet)
(ie-icd)/(iacd-icd)
(1-xr)*scd+xr*sacd
i2-ie
i2t-ie
100*Hicd/Htcd
iot*Do/3,6
Do/3,6 masurat
calculat
calculat
masurat
Calculat
Calculat
Calculat
calculat
Dpr1+.......Dpr7
1%din debit abur viu
calculat
calculat
Dpr7*i7

Pta1+...Pta7
Dcd*ie
aprox
aprox
Pbg*1000+Dpgen+Dpmec
Ptao-Ptt-Ptcd-DPgen-DPmecPbg*1000
Dab,bb*icd
100*Pbg*1000/(Pbg*1000+DPgen)
100*(Pbg*1000+DPgen)/
(Pbg*1000+DPgen+DPmec)
100*(iot-ie)/(iot-iet)

2.3.3. Bilan termoenergetic


Denumire
Pta0
TOTAL INTRAT - Qi
Pbg
Pta7
Pta6
Pta5
Pta4
Pta3
Pta2
Pta1
TOTAL UTIL - Qu (Pbg+Pta1Pta7)
Ptcd
DPgen
DPmec
DPdiv
TOTAL PIERDERI-Qp (DPgen+mec+div)
TOTAL IESIT - Qe (Qu+Qp)

kW

259233.975
259233.975
48000
17022.5809
14375.1348
57723.8731
597.387
2881.8504
81811.6636
0
222412.4898
35370.09
400
400
651.4
36821.49
259233.9798

100
100
18.5160915
6.56649303
5.545235651
22.26709408
0.230443174
1.111679285
31.55900518
0
85.7960419
13.64407964
0.154300762
0.154300762
0.251278792
14.20395996
100.0000019

23

2.5.

2.3. Bilan exergetic


2.3.1. Mrimi calculate
Ecuaia de bilan exergetic pentru turbin este:
Pbg E pdiv Ei Ee [kW]

(31)

unde: Epdiv [kW] - pierderi diverse; Ei, Ee [kW] exergia la intrarea (a aburului la intrarea in
turbina), respectiv ieirea din turbin (a aburului iesit la prize si la condensator).
Ei Eta 0 D0 i0t i0 T0 s0t s0

[kW]

(32)

unde: s0t, s0 entropia aburului corespunztoare parametrilor de intrare n turbin, respectiv


strii de referin, n kJ/kg0C; i0- entalpia aburului la starea de referin, n kJ/kg; T0temperatura de referin (293 0K), n 0K.

Ee Dcd ie i0 T0 se s0 D pri i pi i0 T0 s pi s0

[kW] (33)

i 1

unde: se, spi entropia aburului la ieirea din turbin la condensator, respectiv la prize, n
kJ/kg0C.
Randamentul exergetic al turbinei cu abur este cel care arat msura n care exergia
preluat de agentul termic n cazan, se regsete sub form de lucru mecanic efectiv:

ex,t

Pbg
Eutil

(34)

.100

unde Eutil este exergia utila la cazanul de abur.


Analiza exergetic a turbinei a fost realizat pentru aceleai date ca i analiza
energetic. Rezultatele sunt prezentate n continuare.
Denumire
Exergia abur intrare
Exergie iesita la priza 7
Exergie iesita la priza 6
Exergie iesita la priza 5
Exergie iesita la priza 4
Exergie iesita la priza 3
Exergie iesita la priza 2
Exergie iesita la priza 1
Exergie iesita la cond
Exergia la borne generator
Total exergie iesita
Pierderi diverse de exergie
Rand.exergetic turbina

24

Simbol

U.M.

Eta0
Eta7
Eta6
Eta5
Eta4
Eta3

kW
kW
kW
kW
kW
kW

Eta2
Eta1
Etcond
Pbg

kW
kW
kW
kW

Epdiv

kW

rext

Valoare

114045.2874
6241.314339
4908.656844
18694.39405
155.06694
737.6304
17023.7166
0
2210
48000
49970.779
16075
47.81013443

2.3.2.Bilan exergetic
Denumire
Eta0
TOTAL INTRAT
Eta7
Eta6
Eta5
Eta4
Eta3
Eta2
Eta1
Etcond
Ebg
Epdiv
TOTAL IESIT

Valoare, kW
114045.2874
114045.2874
6241.314339
4908.656844
18694.39405
155.06694
737.6304
17023.7166
0
2210
48000
16075
49970.779

%
100
100
5.47266308
4.304129487
16.39207939
0.135969617
0.646787269
14.9271548
0
1.937826674
42.08854315
14.09527773
100.0004312

25

3.

BILAN TERMOENERGETIC I EXERGETIC CIRCUIT


TERMIC

3.1.

Descrierea circuitului termic

Aburul viu provenit din bara colectoare de abur viu este repartizat la admisia corpului
de P al turbinei prin 2 conducte. nainte de admisia n CP, aburul trece prin VIR. Dup
destinderea n CP, o parte din abur, este dirijat la consumatorul industrial prin 2 conducte
prevzute cu clapete de reinere iar cealalt parte intr n CMP-CJP prin 4 ventile de reglare.
ntre cele 2 conducte ale prizei industriale este prevzut un racord dotat cu vane de izolare
spre boilerul de vrf (BV). n CMP aburul se destinde pn la presiunea prizei de termoficare
iar cealalt intr n diafragma de reglare n CJP, de unde, dup destindere, ajunge n
condensatorul turbinei. Din camera prizei de termoficare aburul iese printr-o conducta spre
boilerul de baz (BB).
Condensatul de baz este aspirat din condensatorul turbinei de pompele de condensat
principal i este refulat prin PJP1... PJP4 spre degazorul de 6 ata.
Apa de alimentare este aspirat din degazor de electropompa de alimentare i dirijat
ctre prenclzitoarele PIP5, PIP6 i PIP7.
Condensatul secundar de la PIP-uri se scurge n cascad spre degazorul de 6 ata.
Condensatul secundar de la PJP4 se scurge n cascad n PJP3 i de aici n PJP2. Condensatul
secundar din PJP2 este trecut printr-un expandor. Aburul rezultat din expandor este rcit n
RE si ntors n condensator. Condensatul rezultat din expandor este introdus cu pompe
condens secundar (EPCS) n circuitul condensatului principal. Condensatul secundar de la
PJP1 se scurge n condensator.
Termoficarea este asigurat de 2 boilere, unul de baz i unul de vrf, n care apa de
reea poate fi nclzit pn la temperatura de 1500C . Boilerul de baz poate nclzi apa pn
la maximum 1140C, diferena de temperatur pn la 1500C fiind preluat de boilerul de vrf.
Boilerul de baz este un schimbtor de cldur abur-ap, de suprafa, orizontal, cu
evi drepte, cu 2 treceri pe partea de ap i o trecere pe partea de abur. Apa circul prin evi iar
aburul prin exteriorul evilor. Boilerul este compus din dou plci tubulare, 2 capace i evi
schimbtoare. Caracteristicile tehnice ale boilerului de baz sunt:
- presiunea maxim a aburului: 2,5 ata
- presiunea maxim a apei: 17 ata
- temperatur ap intrare: 55-700C
- presiune ap intrare: 14 bar
- debit maxim intrare: 2200 t/h
- temperatur maxim abur: 1300C
- suprafa de schimb de cldur: 1000 m2
- lungimea boilerului: 9270 mm
- diametrul interior al boilerului: 1600 mm
26

- masa boilerului n gol: 26600 kg


Boilerul de vrf este un schimbtor de cldur vertical, de construcie complet sudat.
Schimbul de cldur se efectueaz prin suprafa, aburul avnd o trecere printre evi iar apa 2
treceri prin evi. Caracteristicile tehnice ale boilerului de vrf sunt:
- temperatur apa n evi: 1500C
- presiune ap n evi: 19 bar
- presiune abur: 14 bar
- temperatur abur: 3700C
- suprafa de schimb de cldur: 550 m2
- nlimea boilerului: 3250 mm
- diametrul interior al boilerului: 1600 mm
- masa boilerului n gol: 23200 kg

3.2.

Bilan termoenergetic i exergetic schimbtoare de cldur

Circuitul regenerativ al CET este constituit din 4 prenclzitoare de joas presiune,


PJP1...PJP4 i 3 prenclzitoare de nalt presiune PIP5...PIP7. Acestea sunt schimbtoare de
cldur de suprafa abur-ap.
Orice schimbtor de cldur este un aparat imperfect ale crei pierderi se pot mpri
n 3 categorii:
- pierderi de temperatur datorit transferului cldurii la o diferen finit de
temperatur;
- pierderi de cldur prin pereii sau izolaia schimbtorului n mediul nconjurtor;
- pierderi de presiune datorit nvingerii rezistenelor hidraulice la curgerea agenilor
termic.
3.2.1. Bilan termoenergetic
Pentru fiecare schimbtor de cldur se scrie ecuaia bilanului termic i se calculeaz
indicii specifici. Ecuaia de bilan termic este:

Q1 Q2 Q p

Q2

[kW]

(35)

unde:

Q1 D1 i1 i1 W1 t1 t1 W1 t1 [kW]

Q2 D2 i2 i2 W2 t 2" t 2' W2 t 2

(36)
[kW]

(37)

W1 D1c p1 ;W2 D2 c p 2

[kW/0C]

(38)

t1 t1 t1; t 2 t 2 t 2

[0C]

(39)

D1 D1, ab D1, cd

(40)

Q1 , Q2 - fluxul de cldur cedat de agentul cald, respectiv primit de la agentul rece, n kW;
Qp - fluxul de cldur pierdut de aparat n mediul ambiant, n kW; r - coeficientul de reinere
a cldurii n aparat; t1,t2 - temperaturile medii n aparat a agentului cald, respectiv rece, n oC;
D1, D2 - debitul masic de agent cald, respectiv rece, n Kg / s; D1,ab - debit abur intrat, n Kg /
s, D1,cd - debit condens intrat (recuperat de la schimbtoarele cu presiune mai mare a
27

aburului), n Kg / s; cp1, cp2 - cldura specific medie la presiune constant a agentului cald,
respectiv rece , n kJ / KgoC; W1,W2 - capacitatea termic a agentului cald, respectiv rece, n
kW/0C; t1', t1" - temperatura agentului cald la intrare, respectiv la ieire din aparat, n oC; dt1,
dt2 - variaia de temperatur n aparat a agentului cald, respectiv rece, n oC; i1', i1" - entalpia
specific a agentului cald, intrarea, respectiv la ieirea din aparat, n kJ / Kg .
La notaiile de mai sus s-au utilizat urmtorii indici:
1 - pentru agentul cald; 2 - pentru agentul rece
' - pentru intrarea n aparat; " - pentru ieirea din aparat.
3.2.2. Bilan exergetic
Procesele de schimb de cldur se desfoar cu variaia exergiei agenilor termici.
Ecuaia bilanului exergetic este de forma:
E1 E2 E p

[kW]

(41)

unde E1 i E2 sunt exergia agentului cald, respectiv rece i Ep este exergia pierdut n
schimbtor.
Exergia agentului termic, E, este:
E D e D i i0 T0 s s0

[kW]

(42)

unde: e [kJ/kg] exergia specific a agentului termic; D [kg/s] debitul de agent termic;
fluidul care transport cldura are temperatura T, n 0K, entalpia i i entropia s, n J/kg, iar la
temperatura mediului ambiant T0 are parametrii i0 i s0, n J/kg.
3.2.3. Indici de calitate
Se calculeaz urmtorii indici de calitate ai schimbtoarelor de cldur:
- Randamentul termic (coeficientul de reinere a cldurii), r:

Q2
Q1

(43)

unde: Q2 - fluxul de cldur preluat de agentul rece, n kW; Q1 - fluxul de cldur cedat de
agentul cald, n kW; Qp - fluxul de cldur pierdut n mediul ambiant, n kW.
Coeficientul de reinere a cldurii are semnificaia unui randament al izolaiei termice.
- Randamentul termodinamic , td:

D2 i2 i2

td 0
(44)

Q1
D1 i1 i1

unde Q2 - fluxul transmis agentului rece, n kW; Q10 - fluxul de cldur transportat de agentul
cald; t10 - temperatura de referin a mediului ambiant, n 0C; i10 - entalpia agentului cald la
temperatura t10, n kJ/kg.
Mrimea Q10 reprezint fluxul de cldur pe care fluidul cald l poate transmite ntr-un
proces de transfer de cldur pn la echilibru cu mediul ambiant, la care fluidul cald are
temperatura t10 i entalpia i10. Cu ajutorul randamentului termodinamic se poate evalua gradul
de utilizare a cldurii transportate de agentul cald.
Q2

28

Randamentul exergetic, ex:

ex

D2 e2 e2
E 2 E 2

E1 E1
D1 e1 e1

(45)

unde: E1', E1" - fluxul de exergie al agentului cald la intrarea respectiv la ieirea din aparat, n
kW; E2', E2" - fluxul de exergie al agentului rece la intrarea, respectiv ieirea din aparat, n
kW; D1, D2 - debitul de agent cald, respectiv rece, n kg/s; e1', e1" - exergia specific a
fluidului cald la intrarea, respectiv la ieirea din aparat, n kJ/kg; e2', e2" - exergia specific a
fluidului rece la intrarea, respectiv la ieirea din aparat, n kJ/kg; Ep - fluxul de exergie
pierdut de aparat, n kW. Randamentul exergetic este un indice ce caracterizeaz n mod
complet funcionarea unui schimbtor de cldur, innd seama de toate pierderile termice i
hidrodinamice ale aparatului.
Rezultatele analizei energetice i a celei exergetice a schimbtoarelor de cldur din
circuitul regenerativ sunt prezentate n continuare.

29

Date msurate i calculate

AGENT CALD
p1
t'1
t"1 (temp.de saturatie)
i'1
s'1
i"1
s"1
D1,cd
D1,ab
D1
AGENT RECE
p2
t'2
t"2
i'2
s'2
i"2
s"2
D2

PJP2

PJP3

PJP4

PIP5

PIP6

PIP7

BB

BV

bara
C
C
kJ/kg
kJ/kgC
kJ/kg
kJ/kgC
kg/s
kg/s
kg/s

1,3
108
107
2688.52
7.27579
448.726
1.385
1,25
0,28
1,52

3,4
156
138
2771.01
7.04599
580.59
1.7185
0,21
1,04
1,25

3,5
191
139
2844.7
7.19802
584.874
1.7288
0
0,21
0,21

11,7
304
187
3055.79
7.06131
794.073
2.2067
10,01
3,18
13,19

19,4
320
211
3071.61
6.86316
902.198
2.433
5,33
4,68
10,01

27
381
228
3193.73
6.91291
980.81
2.5916
0
5,33
5,33

1,15
120
103
2715.08
7.4
431.827
1.3409

11
304
184
3057.61
7.0216
780.753
2.1779

30,16

2,79

bara
C
C
kJ/kg
kJ/kgC
kJ/kg
kJ/kgC
kg/s

4
90
100
377.372
1.192
419.466
1.3069
16,7

4
100
129
419.466
1.3069
542.279
1.6284
16,7

4
129
135
542.279
1.6284
567.869
1.687
16,7

168
180
205
771.341
2.1182
880.978
2.3537
85,1

168
205
232
880.978
2.3537
1002.64
2.60118
85,1

13,5
59
81
248.199
0.8179
340.323
1.0865
680,6

14
81
83
340.363
1.08648
348.753
1.1101
680,6

168
160
180
685.162
1.9237
771.341
2.1182
85,1

30

Bilan termoenergetic
FLUXURI TERMICE
Q1,ab(cedat de ab)
Q1,cd(ced.de cond
Q1(cedat total)
Q2(primit de apa)
Qp
Q1,0(la 20 C)

kW
kW
kW
kW
kW
kW

PJP2
627.14232
163.51136
790.65368
702.9698
87.68388
5212.2928

PJP3
2278.0368
0.89964
2278.93644
2050.9771
227.95934
3564.78546

PJP4
474.56346
0
474.56346
427.353
47.21046
705.5874

PIP5
7192.26006
1082.33125
8274.59131
7333.8329
940.75841
16702.24082

PIP6
10152.84816
419.00196
10571.85012
9330.1087
1241.74142
19388.04673

PIP7
11794.8636
0
11794.8636
10353.4362
1441.4274
17908.4802

BB
68862.91048

BV
6352.431

68862.91048
62699.5944
6163.31608
0

6352.431
5710.234
642.19703
0

PJP2
156.6436284

PJP3
737.6334472

PJP4
155.0657094

PIP5
3146.782261

PIP6
4976.862322

PIP7
6241.298722

BB
16576.17728

BV
2798.3957

PJP2
0.889099511
0.134867673

PJP3
0.899971173
0.575343768

PJP4
0.900518131
0.605669829

PIP5
0.886307568
0.439092753

PIP6
0.882542658
0.481229947

PIP7
0.87779194
0.578130365

BB
0.910498757

BV
0.8989053

Bilan exergetic
FLUXURI
EXERGETICE
E1,ab
E1,cd
E1
E2
Ep

kW
kW
kW
kW
kW

Indici de calitate
Indici de calitate
Rand.termic
Rand.termodinamic
Rand.exergetic

%
%
%

31

3.3.

Bilan termoenergetic i exergetic circuit termic

3.3.1. Bilan termoenergetic


Procedeul general de stabilire a eficienei termodinamice a unui ciclu const n
determinarea randamentului termic al acestuia.
Calculul fluxurilor energetice i al indicilor energetici ai circuitului termic i ai
centralei pe ansamblu este prezentat n tabelele urmtoare.
Denumire
Flux electric
Flux termic in putere mec.utila
Flux termic cedat in BB
Flux termic cedat in BV
Flux termic cedat in preinc
Flux termic cedat total
Flux util in cazan
Flux termic cedat in condensator
Flux term.iesit cu ab.din caz.
Flux term.intrare turbina
Flux pierdut pe conducte
Procent cons.serv.int.electric
Flux electric servicii interne
Flux electric trafo
Rand transformator electric
Flux electric retea
Flux termic util total
Flux util total CET
Flux consumat in cazan

Simbol
Pbg
Qm
Q1bb
Q1bv
Q1pr
Q1bt
Qu
Q2CET
Qab
Pta0
Qcond
e
Qsi
Ptr
rtr
Pr
Q2bt
QuCET
Qc

U.M.
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
%
kW
kW
%
kW
kW
kW
kW

Valoare
48000
48800
68862.91048
6352.43103

Mod de calcul

75215.34151
192363
32956.056
261165.45
259233.975
1931.475
5
2400
45600
99
45144
68409.8284
113553.8284
242338.965

Q1bb+Q1bv+Q1pr

Simbol
rcond
rt1
rt2
rCET
qb
qc
bsb
bsc

U.M.
%
%
%
%
kj/kj
kJ/kJ
kgcc/kWh
kgcc/kWh

Valoare
99.26044008
64.4695437
82.86774953
46.85743723
1.20
1.77
0.147
0.217

Mod de calcul
Pta0/Qab
100*(Qm+Q1bt)/Qu
100*(1-Q2CET/Qu)
100*QuCET/Qc
1/(rt*rm*rg)
1/(rt*rm*rg*rce*rcond)
3600*qb/29310
3600*qc/29310

Denumire
Qu
TOTAL
INTRAT
Qm
Q1bt
TOTAL UTIL
Epierdut
TOTAL
IESIT

Valoare, kW
192363

%
100

192363

100

48800
75215.34151
124015.3415
68347.65849

25.36870396
39.10073221
64.46943618
35.53056382

192363

100

Pbg/(rm*rg)

Dcd*(ie-icd)

Qab-Pta0
aproximat
0,01*e*Pbg
Pbg-Psi
aproximat
rtr*Ptr
Q2bb+Q2bv
Pr+Q2bt

Indici energetici
Denumire
Rand.conducte
Rand.termic al ciclului
Rand.termic al ciclului
Randament global CET
Cons.sp. cald.borne gen.
Cons.sp.cald.ciclu
Cons.sp.comb.conv.borne
Cons.sp.comb.conv.ciclu

32

3.3.2. Bilan exergetic


Fluxurile de exergie sunt similare fluxurilor de cldur din circuitul termic.
Denumire
Exergie electric
Exergie termic in BB
Exergie termic in BV
Exergie termic preinc
Exergie termic total
Exergie utila cazan
Exergie cedata in condensator
Exergie electric retea
Exergie utila total CET
Exergie consumata cazan

Simbol
Qm
E1b
E1v
E1pr
E2t
Eutil
E2CET
Pr
EuCET
Econs

U.M.
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW

Valoare
48800
16576.17728
2798.395668

Simbol
rex1
rexCET

U.M.
%
%

Valoare
48.60697001

Denumire

Valoare, kW

Eutil
TOTAL
INTRAT
Qm
E2t
TOTAL UTIL
Epierdut
TOTAL IESIT

100397.1241

100

100397.1241

100

48800

48.61

100397.1241
2065.610619
45144

Mod de calcul

Dcd*(ie-icd-T0(se-scd))

206304.3141

Indici exergetici
Denumire
Rand.exergetic al ciclului
Rand.exergetic global CET

33

Mod de calcul
100*(Qm+E2t)/Eutil
100*EuCET/Econs

4. Stabilirea soluiilor optime de economisire a combustibilului n


CET
Examinarea unei instalaii cu ajutorul unui bilan termic arat posibilitatea dirijrii
fluxurilor de cldur n direciile dorite, folosind mijloacele tehnice care stau la dispoziie.
Totodat se poate determina rapid randamentul termic prin raportul dintre cantitatea de
cldur obinut ca efect util i cantitatea de cldur intrat n proces.
Dei are avantaje incontestabile, analiza unei instalaii prin metoda bilanurilor
energetice rmne deficitar n dou privine: pe de o parte, opernd numai cu cantiti de
cldur nu ine seama de calitatea acestora (temperatura), iar pe de alt parte, calculnd
randamentul energetic folosete un criteriu incomplet pentru caracterizarea unui proces
termodinamic, care poate conduce uneori la concluzii greite.
Evitarea acestor inconveniente este posibil numai prin aplicarea simultan a celor
dou principii ale termodinamicii, fapt care presupune ntocmirea simultan a bilanurilor
energetice i exergetice.
Realiznd o paralel ntre analiza energetic i analiza exergetic att a
echipamentelor principale din central ct i a circuitului termic al acesteia se constat
urmtoarele:
- randamentul termic brut al cazanului este de 79,4% n timp ce randamentul exergetic
este de 49,5%. Randamentul exergetic apreciaz gradul de perfeciune termodinamic al
proceselor care se desfoar din punct de vedere al ireversibilitilor interne. Pentru creterea
randamentului exergetic este necesar reducerea pierderilor exergetice.
Deoarece asupra procesului de ardere nu se poate aciona, rezult c cea mai
important cale de reducere a pierderilor datorate ireversibilitii procesului de transfer termic
prin mbuntirea schimbului de cldur i n acest sens se pot aplica urmtoarele msuri:

curirea corespunztoare a suprafeelor;

alegerea regimului aero-gazodinamic corespunztor;

pregtirea corespunztoare a combustibililor naintea introducerii n focar, n


vederea arderii;

etanare corespunztoare pe tot traseul gazelor de ardere.

Ponderea ridicat a pierderilor exergetice se explic pri diferena mare ntre


temperatura gazelor de ardere (1430 0C) i temperatura aburului produs (540 0C).
- puterea la bornele generatorului electric reprezint 18,5% din puterea termic intrat
cu aburul n turbin pe cnd exergia la bornele generatorului este 42,1% din exergia intrat n
turbin. Pierderile termice n condensator reprezint 14,6% din fluxul termic intrat iar
pierderile exergetice n condensator reprezint numai 2% din exergia intrat n turbin.
Aceasta datorit nivelului sczut al temperaturii n condensatorul turbinei. Se impune ca
msur de reducere a pierderilor de exergie din turbin, reducerea pierderilor de abur de
scpri.

34

- n cazul schimbtoarelor de cldur se observ c randamentul exergetic cel mai


cobort l are boilerul de baz (36%). Aceasta se explic prin diferena mare de temperatur
ntre apa de retur din circuitul de termoficare i abur din boilerul de baz.
- n ce privete circuitul termic, randamentul termic este aproape egal cu randamentul
exergetic, dar repartiia este diferit: puterea la bornele generatorului reprezint 25,4% din
fluxul termic intrat i 48,4% din exergia intrat n turbin. Fluxul termic dat n circuitul de
termoficare consumatorului termic este 56,4% din fluxul termic intrat n timp ce exergia dat
n consumatorului termic este de 30% din exergia intrat n turbin. Aceasta se explic prin
faptul c energia electric este n ntregime exergie pe cnd numai o parte din cldura dat n
circuitul de termoficare este exergie. Rezult de aici, necesitatea aplicrii msurilor de
cretere a puterii electrice la bornele generatorului: meninerea parametrilor aburului la
intrarea n turbin i a vidului n condensatorul turbinei la valorile nominale, meninerea
temperaturii apei de rcire la intrarea n condensator la valori ct mai coborte.

35

BIBLIOGRAFIE
1. Hazi A., Hazi Gh, Balane i calitatea energiei, Editura Tehnica Info, Chiinu, 2003
2. Carabulea A., Carabogdan Gh, Modele de bilanuri reale i optime, Editura
Academiei, Bucureti, 1982
3. Carabogdan Gh., .a., Bilanuri energetice. Probleme i aplicaii, Editura tehnic,
Bucureti, 1986
4. Berindea T., .a., ntocmirea i analiza bilanurilor energetice n industrie, Editura
tehnic, Bucureti, 1976
5. Hazi A., Producerea energiei electrice i termice, Editura Alma Mater, Bacu, 2002
6. Hazi A., Instalaii termoenergetice, Editura Alma Mater, Bacu, 2002
7. Leca A., .a., Centrale electrice. Probleme, Editura didactic i pedagogic, Bucureti,
1977
8. Badea A., .a., Echipamente i instalaii termice, Editura tehnic, Bucureti, 2003
9. Ionel I., Ungureanu C., Centrale termoelectrice. Cicluri termodinamice avansate,
Editura Politehnica Timioara, 2004
10. Program de calcul SteamTab

36