Frecvenţa L t Rserie

Nr. Nume LN t fQ Tm TM proprie de IN Rcc


Q o o măs. Q măs calc. calc.
crt. ref. [H] [%] [MHz]* [ C] [ C] rezonanţă [mA] [Ω]
[mH] * [%] [Ω]
[MHz] *
1. L1 10 µ ±10 40 7.96 M -20 100 22 370 0.72 8.79 µ 0.2456 12.1 0.225
2. L2 220 µ ±10 60 796 k -20 100 4 130 6.5 214.8 µ 0.2606 2.36 5.179
3. L3 1m ±10 50 796 k -20 100 1.15 60 30 906.1 m 0.2514 9.39 22.646
4. L4 2.2 m ±5 80 252 k -20 100 1.2 120 14 2.21 m 1.44 -0.64 9.66
5. L5 10 m ±5 60 79.6 k -20 100 0.5 65 74 10.46 m 1.11 -4.6 59.156
6. L6 100 µ ±10 30 796 M -20 80 4.1 800 0.32 104.3 µ 2.39 -4.3 0.274
7. L7 1m ±10 80 252 M -20 80 1.2 180 3 1.02 m 2.13 -2.2 3.003
8. L8 1µ ±10 30 2.52 M -55 125 33 189 2.1 1.143 µ 0.0104 -14.3 3
0.691
9. L9 4.7 µ ±10 30 7.96 M -55 125 50 224 1.5 4.62 µ 0.0205 1.66 1.417
10. L10 0.68 µ ±5 30 30 M -55 125 400 180 1.4 0.615 µ 0.005 9.56 0.773
11. L11 4.7 µ ±5 35 7.96 M -55 125 140 160 1.8 4.91 µ 0.0171 -4.64 1.807
12. L12 47 µ ±10 50 2.52 M -20 85 10 140 5 46.81 µ 0.0816 0.4 3.604
13. L13 1m ±10 20 252 k -20 85 2.5 30 40 1.04 m 0.1922 -4.6 34.195
14. L14 33 m ±10 90 796 M -20 80 0.21 30 110 33.62 m 2.628 -1.88 80.381
15. L15 100 m ±10 35 252 M -20 80 0.11 15 420 102.2 m 2.109 -2.2 304.477
Tabelul 4. Parametrii inductoarelor.

r 2 πf L mas la f =1 kH z
s=
Qmas
Tabelul 2 Variaţia inductanţei şi a factorului de calitate cu frecvenţa

f(kHz) L3 L5 L7 L9 L13 L14 L15


L (mH) 0.906 10.51 104 4.6 µ 1.046 34.23 104.2
0.1
Q 0.1963 0.1138 0.225 0.002 0.0192 0.2854 0.2235
L (mH) 0.906 10.52 104 4.78 µ 1.046 34.24 104.2
0.12
Q 0.2352 0.1365 0.2697 0.0025 0.0231 0.341 0.2680
L(mH) 0.906 10.48 102.3 4.637 µ 1.046 33.65 102.3
1
Q 2.2512 1.11 2.135 0.0206 0.1921 2.622 2.105
L(mH) 0.901 9.645 97.36 4.633 µ 1.044 31.48 96.49
10
Q 9.673 7.562 14.82 0.2057 1.882 15.57 12.95
L(mH) 0.895 8.632 136.6 4.577 µ 1.012 33.97 129.8
100
Q 15.92 13.39 30.67 2 14.46 56.45 27.03
L(mH) 0.887 9.082 -308.6 4.599 µ 1.002 47.36 -397.3
200
Q 23.49 17.29 9.726 3.906 26.06 25.91 4.803

Se observa o crestere foarte accentuate a factorului de calitate la frecvente mari , dar totusi inferioare frecventei de rezonanta, de unde
si cresterea monotona a parametrului Q. Inductanta ramand aproape constanta pe parcursul tuturor masuratorilor
Tabelul 3 Comportarea în funcţie de frecvenţă

UI I=UI/Rs La=UG/ωI
f(kHz)
[Vvv] [mAvv] [mH]

1 7.4 0.74 430.15


10 19.8 1.98 16.08
L14 UI I=U
50 16.6 I/Rs
1.66 La=U
3.84G/ωI
f(kHz)
100 [Vvv]
9.2 [mAvv]
0.92 [mH]
3.46
200 2.4 0.24 6.63
1 19.8 1.98 160.76
300
10 0.4
17.4 0.04
1.74 26.53
18.29
L15 400 0.4 0.04 -19.89
50 6.4 0.64 9.95
500
100 20
2.32 2
0.232 17
13.72
200 0.16 0.016 99.47
300 0.64 0.064 -16.58
400 1.04 0.104 -7.65
500 2 0.2 10
200

150

100
La (mH)

50

0
0 100 200 300 400 500 600

-50

f (kHz)