Specific thermal bridges at load bearing masonry buildings - Punţi termice


specifice clădirilor cu pereţi structurali din zidărie

Book · September 2013

CITATIONS READS

0 214

2 authors, including:

Ligia Moga
Universitatea Tehnica Cluj-Napoca
47 PUBLICATIONS   76 CITATIONS   

SEE PROFILE

Some of the authors of this publication are also working on these related projects:

Thermal Bridges Catalogue – Calculation of temperature fields and heat flows for thermal bridges using specialized software View project

Energetics Perspective on the Environmental and Human Impact of Buildings View project

All content following this page was uploaded by Ligia Moga on 29 October 2017.

The user has requested enhancement of the downloaded file.


Colecţia: Ligia Mihaela MOGA
Ioan MOGA
Construcţii

PUNȚI TERMICE SPECIFICE CLĂDIRILOR


CU PEREȚI STRUCTURALI DIN ZIDĂRIE

EDITURA U.T.PRESS
str.Observatorului nr.34
C.P.42, O.P. 2
400775 Cluj-Napoca
e-mail: utpress@biblio.utcluj.ro

ISBN 978-973-662-799-6 9 789736 627996

www.utcluj.ro/editura UTPRESS
Cuprins
1. Introducere ............................................................................................................................................. 1
2. Considerente Teoretice ....................................................................................................................... 2
2.1. Aspecte Generale ......................................................................................................................... 2
2.2. Considerente Teoretice ............................................................................................................... 3
2.2.1. Introducere ............................................................................................................................. 3
2.2.2. Termeni, definiţii, simboluri şi unităţi de măsură......................................................... 3
2.2.3. Reguli de modelare .............................................................................................................. 5
2.2.4. Valori de calcul .................................................................................................................... 11
2.2.5. Date de intrare ..................................................................................................................... 12
2.2.6. Date de ieşire ....................................................................................................................... 12
2.2.7. Metodă de calcul ................................................................................................................. 16
2.3. Programul de Calcul „PSIPLAN” ............................................................................................ 22
2.3.1. Generalităţi ale programului de calcul de tip expert ................................................. 22
2.3.2. Algoritmul programului de calcul................................................................................... 22
2.3.3. Structura generală a programului de calcul „PSIPLAN” şi metoda de lucru ..... 24
2.4. Referinţe normative.................................................................................................................... 25
3. Tipuri de Punţi Termice ..................................................................................................................... 26
3.1. Sâmburi din b.a. înglobaţi în zidărie ...................................................................................... 26
3.1.1. Perete exterior de 24 cm............................................................................................... 27
3.1.2. Perete exterior de 29 cm............................................................................................... 28
3.1.3. Perete exterior de 36,5 cm ........................................................................................... 29
3.1.4. Perete exterior de 44 cm............................................................................................... 30
3.1.5. Perete exterior de 49 cm............................................................................................... 31
3.2. Intersecţie orizontală perete exterior - perete interior; secţiune orizontală................ 32
3.2.1. Perete exterior de 24 cm............................................................................................... 33
3.2.2. Perete exterior de 29 cm............................................................................................... 34
3.2.3. Perete exterior de 36,5 cm ........................................................................................... 35
3.2.4. Perete exterior de 44 cm............................................................................................... 36
3.2.5. Perete exterior de 49 cm............................................................................................... 37
3.3. Intersecţie pereţi la colţ ieşind ................................................................................................ 39
3.3.1. Pereţi exteriori de 24 cm............................................................................................... 40
3.3.2. Pereţi exteriori de 29 cm............................................................................................... 41
3.3.3. Pereti exteriori de 36,5 cm ........................................................................................... 42
3.3.4. Pereti exteriori de 44 cm............................................................................................... 43
3.3.5. Pereti exteriori de 49 cm............................................................................................... 44
3.4. Intersecţie pereţi la colţ intrând .............................................................................................. 45
3.4.1. Pereţi exteriori de 24 cm ................................................................................................ 46
3.4.2. Pereţi exteriori de 29 cm ................................................................................................ 47
3.4.3. Pereţi exteriori de 36,5 cm ............................................................................................ 48
3.4.4. Pereţi exteriori de 44 cm ................................................................................................ 49
3.4.5. Pereţi exteriori de 49 cm ................................................................................................ 50
3.5. Intersecţie perete exterior – planşeu nivel curent ............................................................. 51
3.5.1. Intersectie perete exterior de 24 cm – planşeu nivel curent ................................. 52
3.5.2. Intersecţie perete exterior de 29 cm – planşeu nivel curent ............................... 53
3.5.3. Intersecţie perete exterior de 36,5 cm – planşeu nivel curent............................. 54
3.5.4. Intersecţie perete exterior de 44 cm – planşeu nivel curent ............................... 55
3.5.5. Intersecţie perete exterior de 49 cm – planşeu nivel curent ................................ 56
3.6. Intersecţie perete exterior–planşeu cu placa balcon; secţiune verticală prin şpalet 57
3.6.1. Intersecţie perete – planşeu cu placă de balcon neizolată termic......................... 58
3.6.2. Intersecţie perete– planşeu cu placă de balcon izolată inferior cu 5 cm ............. 63
3.6.3. Intersecţie perete– planşeu cu placă de balcon izolată inferior cu 10 cm .......... 68
3.6.4. Intersecţie perete–planşeu placă de balcon izolată inferior şi superior cu 5 cm ..
................................................................................................................................................. 73
3.6.5. Intersecţie perete–planşeu placă de balcon izolată inferior şi superior cu 10 cm
................................................................................................................................................. 78
3.7. Secţiune orizontală prin fereastră .......................................................................................... 83
3.7.1. Secţiune orizontală prin fereastră montată la faţa interioară a zidului ................ 84
3.7.2. Secţiune orizontală prin fereastră montată în axul zidului ..................................... 89
3.7.3. Secţiune orizontală prin fereastră montată la faţa exterioară a zidului................ 94
3.8. Secţiune verticală prin fereastră în dreptul parapetului ................................................... 99
3.8.1. Fereastra montată la faţa interioară a zidului............................................................ 100
3.8.2. Fereastra montată în axul zidului ................................................................................. 105
3.8.3. Fereastra montată la faţa exterioară a zidului ........................................................... 110
3.9. Secţiune verticală prin fereastră sub buiandrug .............................................................. 115
3.9.1. Fereastra montată la faţa interioară a zidului............................................................ 116
3.9.2. Fereastra montată în axul zidului ................................................................................. 121
3.9.3. Fereastra montată la faţa exterioară a zidului ........................................................... 126
4. Bibliografie ......................................................................................................................................... 131
2. Considerente Teoretice
În această parte a lucrării se fac specificaţii care conţin limitele modelului geometric
şi subdiviziunile sale, condiţiile la limitele termice, valorile şi relaţiile termice care au fost
utilizate în faza de efectuare şi elaborare a cercetării.

2.1. Aspecte Generale


În elaborarea lucrării s-au parcurs următorii paşi:
- prezentarea consideraţiilor teoretice privind abordarea şi analiza punţilor termice;

- prezentarea programului de calcul de tip expert „PSIPLAN”, dezvoltat din


programul mamă „CIMPPLAN”, în scopul modelării şi evaluării punţilor termice.
Programul de calcul este structurat pe module cu algoritmi de calcul specifici
tipurilor principale de punţi termice. Activitatea complexă de modelare 2-D a
detaliilor de punţi termice liniare a fost efectuată de către unul din modulele
specifice dedicate acestei activităţi;

- prezentarea schemelor principiale ale mai multor tipuri de punţi termice, care
reprezintă o bază de plecare în generarea unor altor tipuri de punţi termice (cu şi
fără izolaţie termică). Totodată se prezintă pe aceste detalii modul de amplasare a
punctelor caracteristice în care se vor determina valorile coeficienţilor de transfer
termic liniar. Amplasarea acestor puncte caracteristice s-a efectuat atât pe faţa
exterioară a punţii termice, cât şi pe faţa interioară a acestora;

- prezentarea fazelor necesare a fi parcurse în rezolvarea a 3 tipuri de punţi termice


pentru înţelegerea modului de lucru cu programul „PSIPLAN”,

- prezentarea evaluării energetice a două tipuri de pereţi plini amplasaţi în câmpul


curent al faţadei şi în zona de colţ a faţadei;

Lucrarea s-a întocmit pe baza bibliografiei complexe prezentate în lucrare, precum


şi pe baza vastei experienţe în informatica aplicativă pentru calculule în domeniul
higrotermicii clădirilor. Pentru acest domeniu începând din anul 1978 au fost elaborate
câteva zeci de programe cu mai multe variante, pentru fiecare dintre acestea, toate
programele dispunând de variante actualizate la anul 2010.
Abordarea ştiinţifică a elaborării cataloglui de punţi termice este asigurată atât de
specialişti care formează echipa de lucru cât şi de utilizarea unui instrument de calcul
validat la cel mai înalt nivel actual, nu numai prin satisfacerea testelor internaţionale de
validare cât şi prin lunga perioadă de utilizare a acestui instrument de calcul în activitatea
de cercetare, proiectare şi reabilitare termică a clădirilor, precum şi în activitatea de
elaborare a altor cataloage de punţi termice pentru produse specifice.

2
3.2. Intersecţie orizontală perete exterior - perete interior;
secţiune orizontală
2.a Convenţia pentru dimensiunile de calcul

2.b Modelul geometric şi condiţii de contur pentru calculul:

32
3.2.1. Perete exterior de 24 cm

33
3.2.2. Perete exterior de 29 cm

34
3.2.3. Perete exterior de 36,5 cm

35
3.2.4. Perete exterior de 44 cm

36
3.2.5. Perete exterior de 49 cm

37
3.2.5. Perete exterior de 49 cm ( continuare )

38
3.6.4.2. Perete exterior de 29 cm

74
3.6.4.3. Perete exterior de 36,5 cm – planşeu de balcon la parapet

75
3.9.3.3. Perete exterior de 36,5 cm

128
3.9.3.4. Perete exterior de 44 cm

129
3.9.3.5. Perete exterior de 49 cm

130

View publication stats