INTERNAIONAL
"Soluii pentru sisteme de
alimentare cu ap i canalizare
n localiti pn la 10.000
locuitori"
Bucureti
2008
-
Comitetul de Organizare:
-
628.1 (498)
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
CUPRINS
Sectiunea 1 Sisteme de Alimentare cu Apa
Necesitate obiectiva a construciilor hidroedilitare pentru asigurarea confortului
ambiental n colectivitile din mediul rural .......................................................................... 5
I. Mirel, C.Florescu, C.E.Podoleanu,C. Staniloiu,
Poster:
Consideratii privind aplicarea unor filiere unitare de tratare a surselor subterane cu
continut ridicat de azotati ................................................................................................... 56
C. Cosma, M. Nicolau, C. Dumitrescu, C. Bumbac, M. Stefanescu
- 1-
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Poster:
Poluarea surselor de apa si monitorizarea calitatii acestora ........................................... 152
M. Cohl
Network modelling solution for water supply using GIS concepts ................................... 202
Al. Aldea, Mihaela Aldea
Using benchmarking in the UK water industry to support efficiency improvements ........ 209
D. Druett, D.Dimitriu, T.Povall
Poster:
Abordarea integrat calitate-mediu a procesului de ntreinere i reparaii reele de
transport i distribuie ap pentru sisteme de alimentare cu ap i canalizare n
localiti pn la 10000 locuitori....................................................................................... 225
Daniela Simona Moldovan
- 2-
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Seciunea 1
SISTEME DE ALIMENTARE CU AP
- 3-
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 4-
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
REZUMAT
n cadrul lucrrii se subliniaz importana economic, social i ecologic a construciilor
hidroedilitare pentru asigurarea confortului ambiental n cadrul colectivitilor din mediul
rural. Construciile hidroedilitare sunt ansambluri de construcii i instalaii prin care se
asigur alimentarea cu ap potabil i canalizarea apelor uzate din activitile diferitelor
categorii de consumatori. n mediul rural, toate aceste categorii de construcii i instalaii
trebuie s asigure confortul ambiental n spaiile de locuit precum i s previn poluarea
mediului nconjurtor, prin modul de colectare i de epurare a apelor uzate menajere
nainte ca acestea s fie vrsate n emisarii naturali.
Sistemele hidroedilitare concepute pentru mediul rural trebuie s fie simple, robuste i
uor de exploatat, astfel nct impactul economic, social i ecologic asupra fiinelor umane
s fie ct mai redus. Schemele i sistemele tehnologice propuse n cadrul lucrrii se
refer la implementarea de soluii moderne/avansate, att pentru lucrrile de alimentare
cu ap ct i pentru cele care privesc colectarea i epurarea apelor uzate din localitile
rurale.
- 5-
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
n Romnia, sunt n prezent peste 15000 localiti rurale care nu dispun de instalaii
hidroedilitare complete, motiv pentru care sunt necesare proiecte cu soluii tehnologice
moderne, specifice fiecrei localiti, funcie de mrimea acestora, zona geografic i
poziia fa de resursele de ap disponibile i de vecintile cu localitile urbane dotate
cu sisteme centralizate de alimentare cu ap.
- 6-
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 7-
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Apa de la rezervorul 2 este adus gravitaional sau prin pompare la filtrul rapid fr
vane (6) unde sunt reinute suspensiile grosiere, dup care este trecut apoi prin filtrul
lent (8), pentru desvrirea procesului de limpezire i n continuare la rezervorul de ap
filtrat.
Membrana biologic care se formeaz la suprafaa filtrului lent reine bacteriile
patogene i nepatogene, nefiind deci necesar o dezinfecie ulterioar a apei.
Pentru sigurana i securitatea consumatorilor se recomand totui administrarea unei
doze minime de clor sau de hipoclorit de sodiu de 0,50 mg/dm3.
Instalaia, astfel conceput este relativ simpl i uor de exploatat, asigurnd debite
cuprinse ntre 0,50 i 6,00 l/s.
- 8-
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
n tabelul 1 sunt redate dimensiunile geometrice pentru filtrele rapide i cele lente.
Tabelul 1
Q
l/s
0,5
1,0
2,0
3,0
4,0
5,0
6,0
m3/h
1,8
3,6
7,2
10,8
14,4
18,0
21,6
m3/zi
43,2
86,4
172,8
259,2
345,6
432,0
518,4
St
m2
0,36
0,72
1,44
2,20
2,88
3,60
4,30
Filtre rapide
D
mm
600
1000
1200
1600
2x1600
2x1600
2x1600
Hi
m
4,0
4,0
4,0
4,0
4,0
4,0
4,0
St
m2
10
20
40
60
80
100
120
Sl
m2
5
10
20
30
40
50
60
Filtre lente
l
m
2,5
5
5
6
8
10
10
b
m
2x2
2x2
2x4
2x5
2x5
2x5
2x6
Hi
m
2,3
2,3
2,3
2,3
2,3
2,3
2,3
n cazul captrii apelor subterane cu coninut ridicat de fier, deferizarea apei se poate
realiza prin intermediul instalaiei redat n figura 1. Instalaia se compune dintr-un
rezervor metalic mprit pe vertical n dou compartimente. n apa brut din conducta 1,
se injecteaz, aerul comprimat 2. Amestecul apei brute cu aerul comprimat se realizeaz
n toba de aerare 3, de unde apoi trece n compartimentul superior al instalaiei, unde
strbate masa de contact C de jos n sus, dup care prin tubul central trece n
compartimentul inferior unde se afl filtrul rapid echipat cu nisip cuaros. Apa deferizat
iese prin conducta 4. Instalaia hidraulic este completat cu conductele de ap pentru
splare 5, 6, evacuare 7, golire 8, supap pentru evacuarea aerului n exces 9 i dintr-o
gur de vizitare 10 [10].
- 9-
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 10 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
(3) apele uzate sunt conduse la o staie de epurare de tip compact sau sunt transportate
pe cale gravitaional la o staie de epurare comunal sau oreneasc aflat n
vecintatea localitii rurale.
Staia de epurare compact poate deservi chiar mai multe localiti aflate n imediata
vecintate [1], [3], [20].
Vacuum Pipe
Interface
Valve Unit
Vacuu
m
1
3
n cazul sistemelor clasice de canalizare (Figura 7) apele uzate
menajere 1 sunt
2 prevzut cu o treapt mecanic 2 echipat cu
conduse la o staie de epurare compact,
grtar, deznisipator i separator de grsimi i apoi de o treapt biologic constituit dintrun bazin de activare 3 i dintr-un decantor secundar 4 Apele epurate sunt evacuate direct
prin canalul 5 n emisarul 6. Nmolul din decantorul secundar 4 este preluat de conducta
7 i stocat n bazine de stocare i de concentrare a nmolului 8, dup care este utilizat ca
fertilizant pentru culturile agricole 9, [3], [4].
4
3
7
8
9
- 11 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
5
I
III
10
11
2
6
5
1
III
I
11
II
- 12 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
4. Concluzii
Lucrrile hidroedilitare din mediul rural sunt construcii i instalaii indispensabile
pentru asigurarea confortului ambiental n spaiile de locuit dar i pentru prevenirea
polurii mediului nconjurtor.
Schemele tehnologice propuse n cadrul lucrrii sunt doar cteva din alternativele care
se pot utiliza n zonele rurale pentru alimentarea cu ap potabil i canalizarea apelor
uzate menajere.
n acest cadru general, lucrrile de canalizare trebuie s se deruleze n paralel cu
lucrrile de alimentare cu ap sau chiar s le devanseze pe acestea.
5. Bibliografie
Kainz. H., Kauch, P., Renner, H., Siedlungswasserbau und Abfallwirtschaft, Manz Verlag Schulbuch, Wien,
2002.
Mnescu, A., Sandu, M., Ianculescu, O., Alimentri cu ap. Editura Didactic i Pedagogic, Bucureti, 1994.
Mirel, I., Florescu, C., Stniloiu, C., Podoleanu, C., E., Consideraii privind realizarea lucrrilor hidroedilitare n
mediul rural, Conferin Tehnico-tiinific Internaional Probleme actuale ale urbanismului i
amenajrii teritoriului 31 septembrie - 1 octombrie 2004 Chiinu, Republica Moldova.
Mirel, I., Carabe, A., Consideraii cu privire la tratarea apei de suprafa pentru consumatorii din mediul rural,
Simpozionul Instalaii pentru construcii i confort ambiental, 1-3 aprilie 1993, Timioara.
Mirel, I., Epurarea apelor de la gospodrii i uniti izolate. Revista Instalatorul, nr.3, 1993, Bucureti.
Mutschmann, I., Stimmelmayer, F., Taschenbuch der Wasserversargung, Frankh Kosmos Verlag,
Gmbh&Co, Stuttgart, 1991.
Robescu, D., Robescu Diana, Szabolcs, L., Constantinescu, I., Tehnologii, instalaii i echipamente pentru
epurarea apei. Editura Tehnic, Bucureti, 2000.
Rojanschi, V., Bran, F., Diaconu, G., Protecia i igiena mediului. Editura Economic, Bucureti, 1997.
Tchobanoglous, G., Burton, F., Wastewater Engineering, Treatment, Disposal and Reuse. Mc. Graw Hill,
Inc. New York, 1991.
Trofin, P., Alimentri cu ap, EDP Bucureti, 1983.
*** Water Treatment Handbook, vol.1 i2, Degemont, 1991.
*** SR 1343/1 06. Determinarea cantitilor de ap pentru localiti.
*** Legea Proteciei Mediului nr. 137/95, modificat prin HG 314/98 i OG 91/02.
*** Legea Apelor nr.107/96 completat cu legea nr.310/04.
*** Legea privind calitatea apei potabile nr.458/02, completat cu Legea 311/04.
*** NTPA 001/04 privind limitele de ncrcare cu poluani a apelor uzate industriale i oreneti la evacuarea
n recipienii naturali.
*** NTPA 002/04 privind limitele de ncrcare cu poluani a apelor uzate industriale i oreneti la
descrcarea n reelele de canalizare.
*** ATV DVWK A131 ab 5000 Einwohnerwerten.
*** ATV DVWK A126 - 500-10000 Einwohnerwerten.
*** ATV DVWK A116 Unterdruckentwasserung Druckentwasserung.
- 13 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Rezumat
Cercetrile efectuate n ultimii ani n domeniul tehnologiilor neconvenionale cu membrane
de microfiltrare (MF) i ultrafiltrare (UF) demonstreaz c acestea constituie o alternativ
viabil pentru rezolvarea unor probleme din potabilizarea apei, acolo unde tehnologiile
clasice nu mai asigur indicii de calitate corespunztori, n conformitate cu standardele
internaionale.
Performanele acestor
tehnici membranare la tratarea surselor de ape sunt
demonstrate de avantajele oferite fa de procedeele clasice i anume: nu necesit
ageni chimici-coagulani, floculani; cantitile de reactivi folosii la dezinfectare sunt
reduse; separarea se face pe principiul excluderii datorit dimensiunii; apa tratat produs
este de calitate superioar, indiferent de calitatea apei brute; instalaiile sunt compacte;
automatizarea procesului este simpl, etc.
Pentru a asigura o calitate superioar a apei potabile n Timioara, Romnia, am
studiat pe o staie pilot (SP) folosirea acestor tehnologii moderne de microfiltrare
ultrafiltrare ca i soluie alternativ la procedeele clasice utilizate n acest moment pe
Staia de tratare. Varianta de flux adoptat pe SP pentru tratarea apei de suprafa a
rului Bega a fost simpl i a constat n folosirea unui rezervor pentru stocare ap brut,
microfiltrarea (cu filtru de cartue spiralate de 50m) fiind urmat de ultrafiltrare
(tangenial, cu membrane din fibre goale, Hollow Fiber). S-au analizat n paralel probe de
ap brut din rul Bega i de permeat, urmrindu-se gradul de reducere a unor parametrii
msurabili importani (turbiditatea, carbonul organic total i numrul de bacterii coliforme
totale). Rezultatele au fost foarte bune, obinndu-se randamente de reducere a turbiditii
de 97%, n cazul TOC-ului de 20% iar pentru bacteriile coliforme totale de 94%.
n lucrare sunt descrise i aspecte tehnice legate de aceste tehnologii neconvenionale
cu membrane, fiind prezentate i dezavantajele care pot apare prin utilizarea acestora n
diverse aplicaii.
n concluzie, considerm c microfiltrarea i ultrafiltrarea sunt procese excelente n
potabilizarea apelor, ce ofer noi posibiliti de a mbunti calitatea tratrii, ce vor juca
un rol major n viitorul apropiat.
Cuvinte cheie: ap de suprafa, staie pilot, microfiltrare ultrafiltrare.
- 14 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Abstract
The research done in last years in the field of unconventional technologies based on
microfiltration (MF) and ultrafiltration (UF) proved that they are available alternatives for
fixing some problems in drinking water treatment, when classical technologies were not
able to ensure the corresponding quality index, in accordance with the international
standards.
The performances of membrane techniques for water source treatment are
demonstrated by the advantages offered: the use of chemical agents for coagulationflocculation is not necessary; the quantities of reagents used for disinfection are reduced;
separation is based on the principle of exclusion because of size; the treated water
produced has superior quality regardless of the row water quality; the installations are
compact; the automation process is simple, etc.
To ensure high quality of the drinking water in Timisoara, Romania, we have studied
the modern technologies of MF-UF on pilot plant (PP), as an alternative solution to
classical procedures used at present in the treatment plant. The flux adopted in PP for
surface water treatment of the Bega river was simple and consisted in using of a storage
tank for raw water, MF (with spiralled cartridge filter of 50 m) followed by UF ( tangential,
with hallow filter membrane). Samples of raw water and permeate were analyzed in order
to assess the decrease of certain important parameters (turbidity, total organic carbon and
the total number of coliform bacteria). The decrease efficiencies were very good: 97% for
turbidity, 20% in the case of TOC and 94% for total coliform bacteria. The technical
aspects regarding the unconventional membrane technologies are described in this paper,
also highlighting disadvantages that may appear by using this technique in various
applications.
In conclusion, MF and UF proved to be excellent processes for drinking water
treatment, offering new possibilities to improve water quality, which will play a major role
in the near future.
Key words: surface water, pilot plant, microfiltration-ultrafiltration
Introducere
Apa potabil se obine prin diverse tehnici de purificare, adoptate n funcie de numrul de
consumatori, calitatea iniial a apei, tipul sursei (de adncime sau de suprafa), modul
de distribuire a apei ctre consumatori, etc.
Tehnologia clasic de obinere a apei potabile implic etape succesive de tratare
chimic, decantare, filtrare, cu consumuri materiale, energetice i de manoper foarte
mari, aspecte care au determinat cutarea de alternative viabile, tehnici moderne,
performante, cum sunt procesele membranare.
n Romnia, sursele de ap natural sunt relativ srace i distribuite neuniform n timp
i spaiu. Datele statistice arat c circa 80-85% din populaia urban i 10-15% din cea
rural este racordat la sisteme centralizate de alimentare cu ap, iar instalaiile de
captare, transport, pompare, tratare, nmagazinare i distribuie asigur pe ansamblul rii
un debit de ap de circa 115 - 120 m3/s. Acest debit s-a dovedit insuficient i de aceea sa impus necesitatea promovrii de noi tehnici i tehnologii de tratare i mrire a capacitii
instalaiilor de distribuie a apei.
n acelai timp, trebuie rezolvat o alt problem cu care se confrunt populaia din
anumite zone geografice ale rii noastre i anume imposibilitatea aplicrii tehnologiilor
clasice de potabilizare sau utilizarea acestora n condiii neeconomice.
- 15 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 16 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Materiale i metode
Descrierea procedeelor de microfiltrare i ultrafiltrare
Microfiltrarea i ultrafiltrarea sunt procese nrudite distincia ntre cele dou rezid n
mrimea porilor membranei. Membranele de microfiltrare au pori mai mari i sunt folosite
pentru a separa particule de 0,1-10m, spre deosebire de ultrafiltrare care n general este
considerat a se limita la membrane cu diametrul porilor ntre 10-1000. (Baker, 2004)
Prima aplicaie major a membranelor de microfiltrare era pentru culturile de
microorganisme din apa potabil, aceasta rmnnd o aplicaie important n
laboratoarele de microbiologie i biotehnologie. (Kolega and al,1991)
Membranele folosite pentru MF i pentru UF sunt membrane tip por ce funcioneaz
ca nite site. Solventul i particulele de mrime molecular pot trece prin pori, n timp ce
particulele suspendate, particulele coloidale, bacteriile, viruii i chiar i macromoleculele
mari sunt reinute.
Fora conductoare a procesului este diferena de presiune de-a lungul membranei. n
cea mai mare parte a sistemelor cu membrane regenerabile, pentru a se realiza o
funcionare continu, se utilizeaz microfiltrarea tangenial. Aceasta permite evitarea n
principiu a operaiei de colmatare la splarea membranelor. (Kalbfuss and al,2005)
Fluxul tangenial este fluxul permeabil direcionat perpendicular spre fluxul de
alimentare. Impuritile rmn n alimentare care, reducndu-se n volum, prsete
sistemul membranei sub form de flux de reziduu concentrat (un procent de aproximativ
10% din volumul de alimentare). Trebuie fcut o evaluare a concentratului, nainte ca
acest reziduu s poat fi ndeprtat i depozitat, deoarece substanele prezente n acesta
au concentraii de aproximativ 10 ori mai mari dect concentraia lor din fluxul de
alimentare iniial.
Consumul de energie este direct legat de rata fluxului tangenial i de necesarul de
presiune.
Debitele unitare folosite pentru UF se situeaz ntre 0.1-1m3/h.m2.bar pentru o ap
relativ curat, dar se diminueaz considerabil n prezena coloizilor din dou raiuni
eseniale: polarizarea i colmatarea. (Memento Technique de leau,1989)
Primul fenomen este responsabil de apariia unui flux limitat de presiunea
transmembranar.
Influena presiunii transmembranare asupra fluxului n UF este redat n Figura 1.
asupra fluxului n UF
- 17 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Costuri de capital
Pompe
Module de membrane
Spaii de amplasare
Conducte, vane, construcii
Control/altele
Total
Costuri de operare
30
20
10
20
20
100
nlocuirea membranelor
Costuri pentru curare
Energie
Laborator
Total
30-50
10-30
20-30
15
100
Directiva EPA pentru apa de suprafa cere ca toate utilitile n SUA s asigure un
grad de reducere de log 3 pentru Giardia i de log 4 pentru virui. Legislaia european a
adoptat reguli similare.(USEPA, 1999)
Se estimeaz c 40.000 de staii de tratare a apei din SUA sunt afectate de noile
implementri ale EPA, aa c potenialul de pia existent pentru MF n controlul
bacteriologic al apei potabile este foarte ridicat.(Hirata,1998) Multe dintre aceste staii sunt
mici, dar sunt cteva staii de tratare mari care au fost echipate cu sute de module.
Totodat este necesar dezvoltarea sistemelor de filtrare cu curgere transversal,
capabile s dea filtrelor o durat de via de luni sau chiar ani. Astfel de sisteme se
instaleaz acum n staiile de tratare a apelor municipale. Unitile pot fi curate prin
splare invers i se obin astfel performanele dorite. (Baker, 2004)
- 18 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 19 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Condiii de operare
Condiiile de operare pe Staia Pilot au fost:
9 debit alimentare cu apa rului Bega: QAB= 200 L/h;
9 volumul de concentrat (reziduu) s-a fixat n procent de aproximativ 10% din
volumul de alimentare;
9 ciclul de splare n contracurent s-a realizat la fiecare 30 de minute;
9 presiunea diferenial ntre intrare i ieirea de pe membran este
controlat astfel nct s nu depeasc valoarea de 3 bar.
Aparatura
- turbidimetru de laborator, de tip HACH 2100N;
- pH-metru de laborator, de tip Mettler Toledo MP 225;
- analizor TOC, de tip SHIMADZU;
- incubator la 35-37 C, de tip Gallenkamp;
- autoclav pentru 1.2 atm i 121C, de tip Varioklav;
- conductometru, de tip Jenway 4310;
- spectrofotometru, de tip Merck SQ 118;
- truse de reactivi pentru determinarea aluminiului, fierului, manganului, amoniului,
azotiior i azotailor, de tip Spectroquant Merck;
- truse de reactivi pentru determinarea alcalinitii, duritii i calciului, de tip
Aquamerck;
- pipete automate cu volum repetabil, de tip Multipette Eppendorf plus 4981;
- sticlrie de laborator.
Rezultate i discuii
Studiile s-au desfurat n perioada august - octombrie 2007, perioad n care Staia
Pilot a funcionat continuu. Pentru a se asigura funcionarea corespunztoare, diferena
de presiune de-a lungul membranei a fost monitorizat continuu.
S-au analizat n paralel probe de ap brut din rul Bega i de permeat, urmrindu-se
gradul de reducere a unor parametrii msurabili importani: turbiditatea, carbonul organic
total (TOC) i numrul de bacterii coliforme totale (CT).
Frecvena de msurare a parametrilor tehnologici a fost :
- din 2 n 2 ore pentru: debitul de alimentare al SP, turbiditatea i pH-ul apei brute i a
permeatului;
- o dat la 24 ore s-au efectuat determinri pentru: temperatur ap, turbiditate, pH, TOC,
CT, la apa rului Bega i la permeat;
- sptmnal s-au efectuat determinri pentru: turbiditate, pH, alcalinitate, duritate, TOC,
aluminiu, mangan, fier, coliformi totali la apa rului Bega, permeat i concentrat;
- analize generale s-au efectuat trei zile consecutiv pentru apa brut i permeat.
Sinteza datelor experimentale obinute pe SP pentru permeat i apa brut a rului
Bega este prezentat n Tabelul 2.
- 20 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
200
Apa brut
(min-max)
14 - 22
3.1 19.3
7.5 7.7
1.68 2.38
3480 34800
Permeat
(min-max)
14 - 22
0.1 - 1.4
7.5 7.7
1.28 1.99
130 - 1609
Pe Staia de Tratare (ST) a apei rului Bega din municipiul Timioara se aplic
tehnologia clasic de potabilizare cu etape succesive de tratare chimic (cu sulfat de
aluminiu ca i coagulant i aluminat de sodiu ca alcalinizant i coagulant), decantare,
filtrare i dezinfecie cu clor. Eficiena procesului de tratare a apei rului Bega n vederea
potabilizrii (permeat fa de ap brut) pe SP, n ceea ce privete reducerea turbiditii,
este de 97.7% fa de 96.7% ct s-a obinut pe Staia de Tratare.
9 9,0
9 8,5
9 8,0
%
, 7,5
9
e
re
9 7,0
c
u
9 6,5
d
e
r9 6,0
e
9 5,5
d
d5,0
9
ra
g
9 4,5
Statia Pilot
Statia Tratare
9 4,0
0
zile
10
11
12
2,5
2
/L
C1,5
g
m
,
e
i 1
d
e
m
. 0,5
c
n
o 0
c
2,0 1
2,01
1,63
0,43
- 21 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
n Tabelul 3 sunt prezentate valorile medii ale analizelor generale ce s-au efectuat trei
zile consecutiv pentru apa brut i permeat, ct i a analizelor sptmnale ce s-au fcut
pe concentrat.
Tabelul 3. Valorile medii ale analizelor generale obinute pe SP pentru apa brut, permeat i concentrat
Parametrul
analizat
Temperatur
Turbiditate
pH
TOC
Coliformi Totali
Amoniu
Azotii
Azotai
Aluminiu dizolvat
Mangan dizolvat
Fier dizolvat
Conductivitate
Duritate
Calciu
Alcalinitate
CCO-Mn
U.M.
0
C
NTU
mgC/L
nr./100 cm3
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
S/cm
D
mg/L
mmol/L
mgKMnO4/L
Metoda de
analiz
STAS 6324/61
turbidimetru
pH-metru
analizor TOC
STAS 3001/91
Spectroquant
Spectroquant
Spectroquant
Spectroquant
Spectroquant
Spectroquant
conductometru
Aquamerck
Aquamerck
Aquamerck
STAS 3002/85
Apa brut
Permeat
Concentrat
14
6.3
7.65
2.03
9580
0
0.042
1.16
0.01
0.03
0.13
222
4.9
29
1.86
9.28
14
0.84
7.66
1.64
745
0
0.05
2.2
0
0.01
0.08
229.6
4.86
29
1.73
7.98
14
9.22
7.56
2.53
10936
0
0.3
1.5
0.03
0.03
0.17
212
4.86
29
1.56
10.65
Concluzii
1. Studiul efectuat confirm faptul c utilizarea tehnologiilor neconvenionale cu
membrane de microfiltrare (MF) i ultrafiltrare (UF) la tratarea surselor de ap de
suprafa este o soluie alternativ viabil la procedeele clasice de potabilizare.
2. S-au obinut pe Staia Pilot randamente de reducere a turbiditii de 97%, n cazul
TOC-ului de 20% iar pentru bacteriile coliforme totale de 94%.
3. Ca principale dezavantaje ale proceselor membranare enumerm: costurile relativ
ridicate deoarece debitul de ap tratat este limitat de suprafaa filtrant a
membranei; se utilizeaz cantiti destul de mari de energie; modulele de membran
trebuie curate des i viaa membranelor este scurt.
4. Ca principale avantaje ale proceselor membranare, oferite fa de procedeele clasice,
amintim: nu necesit ageni chimici-coagulani, floculani; cantitile de reactivi folosii
la dezinfectare sunt reduse; apa tratat produs este de calitate superioar, indiferent
de calitatea apei brute; instalaiile sunt compacte; rapiditate la punerea n funciune;
automatizarea procesului este simpl, etc.
5. Simplitatea acestor procese va determina alegerea lor n viitorul apropiat n locul altor
procese mai sofisticate i costisitoare.
6. Instalaiile de potabilizare prin filtrare cu membrane permit o monitorizare mai bun,
mai complet i mai facil a surselor de ap.
7. Obinerea apei potabile prin tehnologiile neconvenionale membranare va contribui la
sigurana alimentar i sanitar a populaiei, n special a celei din locuri izolate.
- 22 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Bibliografie
[1] Baker, R.W. (2004) Membrane Technology and Applications, 2nd Edition, Ed. Wiley Interscience, 273299.
[2] (1989) Memento Technique de leau, Neuvieme edition, Tome1, Ed. Degremont, 215-217.
[3] Stumm, W. and Morgan,J.J. (1996) Aquatic Chemistry - Chemical Equilibria and Rates in Natural
Waters,Third Edition, Ed. Wiley Interscience, 823-832.
[4] Cross, R.A. (1993) Purification of Drinking Water with Ultrafiltration, The 1993 Eleventh Annual Membrane
Technology/Separations Planning Conference, Newton, MA.
[5] Kolega, M., Grohmann, G.S., Chiew, C.and Day, A.W. (1991) Disinfection and Clarification of Treated
Sewage by Advanced Microfiltration, Water Sci. Technol. 23, 1609.
[6] Rogers, A.N. (1984) Economics of the Application of Membrane Processes, in Synthetic Membrane
Processes, Academic Press, Orlando, FL, 437477.
[7] Eykamp, W., Noble, R.D. and Stern, S.A. (1995) Microfiltration and Ultrafiltration, in Membrane Separation
Technology: Principles and Applications, Elsevier Science Amsterdam,140.
[8] United States Environmental Protection Agency (1999), National Primary Drinking Water Regulations:
Alternative Desinfectants and Oxidants, Guidance Manual, Office of Water, EPA 815-R-99.
[9] Hirata,T. and Hashimoto,A.(1998) Experimental assessment of the efficacy of microfiltration and
ultrafiltration for Cryptosporidium removal. Wat. Sci. Tech. 38(12), 103107.
[10] Yamamura, H., Kimura, K., Watanabe,Y. (2007) Mechanism involved in the evolution of physically
irreversible fouling in microfiltration and ultrafiltration membranes used for drinking water treatment.
Environ.Sci.Technol. 41(19), 6789-6794.
[11] Howe, K.J and Clark, M.M. (2002) Fouling of microfiltration and ultrafiltration membranes by natural
waters. Environ.Sci.Technol. 36(16), 3571-3576.
[12]
Wickramasinghe,S.R., Kalbfuss,B.,Zimmermann,A.,Thom,V.,Reichl,U. (2005) Tangential flow
microfiltration
and
ultrafiltration
for
human
influenza
A
virus
concentration
and
purification.Biotechnol.Bioeng. 92(2),199-208.
[13] Yuasa, A.(1998) Drinking water production by coagulation-microfiltration and adsorption-ultrafiltration.
Wat. Sci. Tech. 37(10), 135146.
*** STAS 3001-1991.
*** Legea 458-2002.
- 23 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Rezumat
Sunt numeroase locatii de foraje de adancime, in special in Campia Romana unde apa
contine hidrogen sulfurat si amoniu. Se impune elaborarea tehnologiilor pentru incadrarea
acestor indicatori in limitele impuse de Legea 458/2002.
Cercetarile efectuate au pus in evidenta faptul ca oxidarea cu doze stoechiometrice de
clor si filtrarea conduc la concentratii de amoniu, hidrogen sulfurat si clor rezidual care se
incadreaza in limitele normelor privind calitatea apei potabile. Calitatea apei tratate
depinde de timpul de reactie a clorului si de tehnologia de filtrare utilizata. Astfel, filtratea
pe membrane (ultrafiltrare) a condus la eficiente ridicate de retinere a sulfului coloidal si la
o stabilitate a calitatii apei in timp in timp ce filtrarea pe nisip cuartos a condus la eficiente
ridicate dupa o perioada de formare a unei membrane pe granulele materialului filtrant.
Cercetarile au analizat doua filiere tehnologice: conventionala cu post-oxidare cu ozon
si adsorbtie pe CAG si o filiera cu ultrafiltrare. Se prezinta concluzii privind criteriile de
alegere a filierei.
Introducere
Cercetarile experimentale au fost efectuate pe o apa subterana avand continut de amoniu
(2 3 mg/l), hidrogen sulfurat (2 4.5 mg/l) si incarcare organica mare (25 30 mg
KMnO4/l). Calitatea acesteia este prezentata in tabelul nr. 1.
Acestea au avut scopul de a identifica cea mai buna tehnologie pentru potabilizarea
apelor cu continut de hidrogen sulfurat si azot amoniacal dar si cu incarcare organica
ridicata.
- 24 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Rec. 1
Rec. 2
Rec. 3
Rec. 4
Rec. 5
7.45
14.8
114
1339
748
7.40
14.5
19.7
1315
751
7.45
14.2
6.2
1396
746
7.45
15
3.04
1285
742
7.42
15
7.9
1044
737
Legea
458/2002
modificata si
completata
de Legea
311/2004
6.5 9.5
5
2500
-
5
19.074
5.074
5.1
17.95
3.67
5.2
19.07
4.51
4.8
17.92
4.48
4.7
17.92
4.76
min.5
-
14
14.28
14.56
13.44
13.16
Valori obtinute
Nr.
crt.
1
2
3
4
5
Indicator
U.M.
pH
Temperatura
Turbiditate
Conductivitate
Sruri
total
dizolvate
Alcalinitate
Duritate totala
Duritate
permanenta
Duritate
temporar
Calciu
Magneziu
Amoniu
Azotiti
Azotai
Bicarbonati
Cloruri
Sulfati
CCO - Cr
Carbon
organic total
uniti
0
C
NTU
S/cm
mg/l (ca
NaCl)
mechiv/l
0
d
0
d
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
mg O2/l
mg/l
64.12
43.74
2
<0.001
3.6
305
262.7
44
10.56
4.29
64.12
38.88
2.5
<0.001
5.1
311.1
252
46
10.56
5.12
72.14
38.88
2.96
<0.001
6.2
317.2
276.9
39
28.8
6.52
56
43.74
1.2
<0.001
4.3
292.8
266.25
44
7.68
-
56
43.74
2.4
<0.001
5.2
286.7
259.15
42
10.56
-
20
Oxidabilitate
29.68
29.21
30.05
23.2
26.22
21
22
Fier
Sulfuri
hidrogen
sulfurat
Sodiu
potasiu
si
mg
KMnO4/l
mg/l
mg/l
0.5
0.5
50
250
250
nici o
schimbare
anormala si
acceptabila
consumatoril
or
20
0.01
2.52
0.01
2.5
0.02
4.32
0.02
0.52
0.01
2.1
0.2
0.1
si
mg/l
148.5
152
185
200
6
7
8
9
10
11
12
13
14
15
16
17
18
19
23
Determinari experimentale
Experimentele au fost efectuate pe instalatia pilot aflata in patrimoniul U.T.C.B. si care
contine urmatoarele trepte de tratare: pre-oxidare cu clor, filtrare rapida pe nisip (inaltimea
stratului de nisip 120 cm), bazin contact ozon, adsorbtie pe carbune activ granular
(inaltimea stratului de carbune 120 cm, EBCT 12 min.), filtrare pe membrane
(ultrafiltrare). Instalatia pilot este prezentata in figura 1.
- 25 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Clor
N - NH4 (mg/l)
3
2.5
2
1.5
1
0.5
0
0
12
- 26 -
16
20
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Apa bruta
Apa bruta
3
Q =38 dm /h
FILTRU CAG 1
POST-OXIDARE CU
OZON
vF = 3.0 m/h
Q =33 dm /h
INSTALATIE
ULTRAFILTRARE
FILTRU CAG 2
vF = 3.0 m/h
Rezultate si discutii
Rezultatele determinarilor experimentale sunt prezentate in cele ce urmeaza.
12
70
CCO-Mn
CCO-Cr
10
AB
8
6
4
O3
AFRN
0.5
1.5
2.5
Apreox.
60
Turbiditate (NTU)
AFCAG1
AFCAG2
3.5
Treapta de tratare
50
40
30
20
AFRN
AB
AFCAG
10
0
0.5
1.5
2.5
3.5
4.5
Treapta de tratare
a.
b.
Figura 4. Variatia concentratiei de sulfuri si hidrogen sulfurat (a) si a turbiditatii (b) pe filiera de tratare
AB apa bruta; Apreox apa preoxidata cu clor; AFRN apa filtrata rapid pe nisip; AFCAG 1 apa filtrata pe
carbune activ granular; AFCAG 2 apa filtrata pe carbune activ dupa oxidare cu ozon.
- 27 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
a.
b.
Figura 5. Imagini la microscop ale perticulelor stratului filtrant inainte de filtrare (a) si dupa filtrare (b).
- 28 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
12
Amoniu (mg/l)
AB
2.5
2
1.5
1
0.5
AFCAG1
AFRN
AFCAG2
0.5
1.5
2.5
CCO-Mn
CCO-Cr
10
AB
8
6
4
2
AFCAG1
AFRN
AFCAG2
3.5
0.5
1.5
2.5
3.5
a.
b.
Figura 6. Variatia concentratiei de azot amoniacal (a) si a concentratiei de substante
organice (b) pe filiera de tratare
AB apa bruta; AFRN apa filtrata rapid pe nisip; AFCAG 1 apa filtrata pe carbune
activ granular; AFCAG 2 apa filtrata pe carbune activ dupa oxidare cu ozon.
Tabel 2. Concentratie trihalometani in apa filtrata pe nisip si apa filtrata pe carbune activ granular.
AFRN
AFCAG1
Legea 458/2002
modificata si completata
de Legea 311/2004
10
15.44
urme
absent
25.44
1.83
15.45
urme
absent
17.28
100
Valoarea
Nr.crt.
1
2
3
4
Compus
Cloroform
Bromdiclormetan
Clordibrommetan
Bromoform
TOTAL THM
UM
g/l
g/l
g/l
g/l
g/l
concentratia de clor liber in apa filtrata a fost de 0.4 0.5 mg/l iar concentratia de
clor total 0.8 0.9 mg/l; aceasta pune in evidenta faptul ca toata cantitatea de clor
introdusa in apa a reactionat cu hidrogenul sulfurat si cu azotul amoniacal;
Au fost recoltate probe la intervale de 30 min. iar rezultatele sunt prezentate in tabelul 3.
- 29 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Nr.crt.
Indicator
U.M.
Rec. 1
Rec. 2
Rec. 3
Rec. 4
Rec. 5
Rec. 6
Turbiditate
NTU
0.08
0.07
0.07
0.05
0.05
0.05
Sulfuri si
hidrogen
sulfurat
Amoniu
Clor liber
Clor total
Substante
organice
CCO - Cr
mg/l
< 0.001
< 0.001
< 0.001
< 0.001
< 0.001
< 0.001
mg/l
mg/l
mg/l
mg KMnO4/l
0.01
1.82
3.2
2.84
0.01
1.4
2.03
2.53
0.01
0.51
0.96
2.53
0.01
0.50
0.85
1.96
0.01
0.42
0.82
1.96
0.01
0.40
0.85
1.96
mg O2/l
0.96
1.01
0.96
0.96
0.92
0.9
3
4
5
6
7
Concluzii
In urma analizei rezultatelor experimentelor efectuate se poate concluziona:
- 30 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
100
90
80
AFRN
AFCAG 1
AFCAG 2
AFM
70
60
50
40
S2si H2S
H2S
NH4+
NH4
CCO - Mn
CCO-Mn
CCO-Cr
CCO-Cr
Figura 7. Eficiente de reducere a concentratiilor principalilor parametrii fata de concentratia in apa bruta.
costurile de operare in etapa actuala sunt mai mari pentru tehnologiile care
utilizeaza membrane (0.11 0.12 /m3 apa fata de 0.075 0.08 /m3 apa pentru
tehnologiile conventionale).
Bibliografie
AWWA Water quality and treatment, Fifth Edition, McGraw Hill, New York, USA, 1999.
Degremont - Memento Technique de lEau, Lavoisier, Paris, 1989.
Taylor, J.S., Wiesner, M. Membranes, In Water Treatment Membrane Process, Mallevialle, J., Odendaal,
P.E., Wiesner, M.R. (ed) McGraw-Hill, New York,. pg.11.1 11.70 (1996).
Taylor, J.S., Wiesner, M. Mallevialle, J., Odendaal, P.E., Wiesner, M.R. Water Treatment Membrane
Process, McGraw-Hill, New York, USA, 1996.
Desjardins, R. Le traitement des eaux - Editions de lEcole Polytechnique de Montreal, 1990.
E.D.H. Guideliness for Canadian Drinking Water Quality, 1993.
- 31 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Summary
An increase of nitrate content in the underground waters used in the rural water supply
systems and even in the large urban systems, above the limits foreseen by Law
no.458/2005 on drinking water quality, was noticed in the last years, leading to the
measure of stopping the exploitation of some underground catchments by the sanitary
authorities and their abandonment.
The article presents data related to the nitrate content increase in the rural water
supply systems from Constanta County. The spreading of nitrate content in the aquifers
developed in Constanta County, where catchments of the centralized water supply
systems by means of boreholes have been executed, is analyzed. Furthermore the
factors which determined the increase of nitrate concentration of the underground waters,
the evolution of the nitrate concentration in time and the measures to be taken for hydrogeological protection of the catchments and of the aquifers exploited are approached.
Solutions for quality improvement of the water distributed through rural centralized
systems are proposed depending on the hydro-geological conditions of each area, the
water demand of each locality, the nitrate concentration, as follows: new catchment works
for good quality high depth aquifers; connecting the water supply system to a neighbour
water source; installing treatment equipments for nitrate reduction, the solution being
chosen also considering the investment and operational costs and assurance of the
stability in time of the drinking water quality.
Given the nitrate concentration increase in the underground waters in general and in
the underground water catchments in particular, registered at country level, the
experience and the solution proposed and partially implemented in Constanta could be
detailed and used also in other areas of the country.
Date generale
In ultimii ani s-a constatat prezenta in apa potabila distribuita intr-o serie de localitati din
judetul Constanta a unui continut peste limitele admise de Legea nr. 458/2002 privind
calitatea apei potabile, cu risc de imbolnavire a populatiei.
Asemenea cresteri au fost inregistrate in peste 30 localitati din judet, situatie sesizata
de organele sanitare judetene (A.S.P.J). La o parte din localitati s-a dispus intreruperea
utilizarii surselor de apa subterana si gasirea unor solutii pentru alimentarea cu apa a
acestor localitati, cu apa de calitate corespunzatoare. Astfel au fost scoase din functiune
captarile de apa Credinta, care asigurau alimentarea cu apa a localitatior Cobadin,
- 32 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 33 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 34 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Harta structurala prezentata in fig. 2.1 arata blocurile separate de catre doua sisteme
de falii orientate VNV-SSE si NNE-SSV. Faliile din primul tip, paralele cu falia importanta
Capidava-Ovidiu, au fost mai active, prezentand si deplasari pe orizontala. Fundamentul
de roci cristaline este abrupt, coborand spre vest (Dunare), generand o crestere
semnificativa a grosimii complexului de carbonati (peste 1000m), cu orientare ascendenta
spre NE (zona de nord a Constantei) si coborand spre sud si est (de-a lungul litoralului).
Directia principala de curgere este V-E. Descarcarea in Marea Neagra are loc in
special in zona orasului Constanta, prin blocurile delimitate de faliile CapidavaOvidiu si Cernavoda-Constanta (zona Lacului Mamaia).
Valorile permeabilitatii acviferului variaza intre zeci sau sute pana la peste 150.000
m2/zi. Inclinarea hidraulica este, de obicei, mai mica de 0.05%. Conductivitatea hidraulica
este de regula mai mare de 102 km/zi, iar coeficientul de inmagazinare variaza intre 10-3
si 10-4.
- Principala directie de curgere este S-N si devine V-E langa falia Capidava-Ovidiu si
in blocul Costinesti-Mangalia. Centrul natural de drenare este reprezentat de catre Marea
Neagra prin Lacul Mamaia (in principal) si zona mlastinoasa de la nord de Mangalia (in
secundar). Realimentarea sistemului acvifer este realizata din zona S, V si SV.
- Acviferul este inchis pe 60% din suprafata sudului Dobrogei. In partea de vest si
sudul orasului Cernavoda exista o zona ce prezinta conditii pentru deschidere. Acolo
acviferul poate fi direct influentat de precipitatii, infiltratii din sistemele de irigare si scurgeri
din acviferul superior.
- 35 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 36 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Analiza continutului de nitrati se refera mai putin la captarile de apa din acviferul de
adancime din depozitele jurasice respeciv captarile Caragea Dermen, Cismea, Basarabi
si Medgidia, care alimenteaza municipiul Constanat si Medgidia in care apa are un
continut scazut de nitrati si in care in perioada de peste 30-40 ani de exploatare nu s-au
constatat modificari importante in continutul de nitrati.
Analiza continutului de nitrati in apele subterane a cuprins in special captarile mici din
judet care asigura alimentarea cu apa a majoritatii localitatilor rurale din judet, captari
vulnerabile la poluarea cu nitrati, dar si la captarile importante din Sarmatian, din partea
de sud a litoralului, si in care se constata cresteri, uneori semnificative, a continutului de
nitrati.
- 37 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- In acviferul jurasic care este resursa cea mai importanta din Dobrogea de Sud,
continutul in nitrati se inscrie in cea mai mare parte in limitele prevazute de legea
458/2002 privind caliatea apei potabile, avand valori de regula sub 10 mg/l. Fac
exceptie cateva captari in care se produc poluari locale fie datorita executiei proaste a
forajelor (Valu Traian), fie lipsei unui strat protector impermeabil deasupra acviferului
(Deleni, Poiana, Independenta). Continutul ridicat in nitrati din captarile din zona
Harsova si Corbu este determinat de circulatia redusa a apei in acvifere limitate si de
poluarea antropica.
b.
in acviferul cretacic:
- 38 -
V iis oara
V alul T raian
T argus or
T ortom anu
S ilis tea
P oiana
R as ov a
P lopeni
P ietreni
O ltina
P es tera
M irc ea V oda
M edgidia-RA J A
Lipnita
M edgidia-E dilm ed
Iv rinez u M are
Independenta
Hars ov a
D eleni
C uz a V oda
C orbu de S us
C ioc arlia
C iobanita
Cernav oda
Chirnogeni
A lim an
B aneas a
300
250
200
150
100
50
-
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
NO3
mg/l
120
100
80
60
40
20
Vlahii
Sipote
Sat u Nou
Salign i
Razoare
Raristea
O strov
Nisipa ri
Negureni
Ion Corvin
G arlita
Esech ioi
Coslugea
Cernav oda
Carvan
Breben i
Basarabi
Almalau
Ada mclisi
- Acviferul din depozite cretacice din partea sud-vestica a Dobrogei de sud este legat
hidraulic de acviferul de adancime din depozitele jurasice, avand de regula acelasi nivel
piezometric. S-a preferat o analiza separata a acviferului cretacic utilizat pentru
alimentarea cu apa a unor localitati rurale prin foraje de adancime medie, 100-200 m,
spre deosebire de forajele care capteaza acviferul jurasic al acestei zone executate la
adancimea de 300-500m. Din graficul b, se constata existenta a numeroase zone in
care continutul in nitrati se inscrie in limite admisibile dar si zone in care aceste limite
sunt depasite. Aceasta situatie este determinata de faptul ca in majoritate, in aceste
zone acviferul cretacic este deschis, fiind influientat de infiltratii de apele de suprafata de
pe vai, de acvifere superficiale cuaternare avand continut ridicat de nitrati si de
activitatile antropice, sectoare zootehnice, ingraseminte chimice sau de lipsa sistemelor
de canalizare din localitatile rurale adiacente.
- Acviferul din depozitele sarmatiene prezinta modificari importante in ce priveste
continutul in nitrati fiind un acvifer freatic, vulnerabil la poluare datorita activitatilor
antropice. Se constata cresteri importante ale continutului de nitrati in majoritatea
captarilor din acest acvifer, in mod deosebit in zonele Plopeni, Casicea, Credinta,
Negresti, Osmancea. O parte din captari au fost scoase din functiune din cauza
continutului ridicat de nitrati, cum sunt Credinta, Plopeni, Casicea, pentru alte localitati
se cauta solutii alternative, cum sunt foraje de adancime care capteaza acviferul jurasic.
c.
in acviferul sarmatian
NO3
mg/l
Valcele
Techirghiol
Tatlageac
Tataru
Pecineaga
Osmancea
Mereni
Dulcesti
Comana
Costinesti
Casicea
Negresti
Biruinta II
Biruinta I
Amzacea
Albesti
450
400
350
300
250
200
150
100
50
-
O situatie speciala o prezinta captarile din sarmatian din zona litoralului, care asigura
alimentarea cu apa a zonelor turistice intre Eforie si Vama Veche. Daca in captarile
Costinesti, Tatlageac, Albesti, Vartop, situatia este inca buna, in captarile Techirgiol,
Biruinta, Dulcesti, Pecineaga, se constata o crestere alarmanta a continutului in nitrati la o
parte din foraje, asa cum se vede din graficele privind evolutia continutului de nitrati in
perioada 2000-2007. Captarea Biruinta II a fost deja scoasa din functiune.
- 39 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
100
80
60
40
20
an executie
2000
2001
2002
P1
2003
P2
P3
2004
P9
P11
2005
2006
2007
Psonda
120
100
80
60
40
20
an executie
2000
2001
P1
2002
P2
2003
P3
P4
P8
2004
P10,10bis
2005
2006
2007
2006
2007
P13
200
150
100
50
an executie
2000
2001
2002
2003
P1
- 40 -
P5
2004
P7
2005
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
70
60
50
40
30
20
10
an executie
2000
2001
2002
P1
2003
P2
P3
2004
P4
P6
2005
2006
2007
2005
2006
2007
P7
100
80
60
40
20
an executie
2000
2001
2002
2003
P1
d.
P2
2004
P3
P4
in acviferul cuaternar:
140
120
100
80
60
40
20
an executie
2000
2001
2002
2003
P4
P5
- 41 -
2004
Pvinalcool
2005
2006
2007
Ostrov
Vadu
Vadu Oii
Tichilesti
Tepes Voda
Tariverde
Targusor
Sinoe
Sibioara
Saraiu
Sacele
Pantelim onul de
Jos
Nistoresti
Pantelim onul de
Sus
Nuntasi
Mireasa
M.Viteazu
M.Kogalniceanu
Horia
Gradina
Faclia
Crucea
Corbu de Sus
Ciobanu
Cogealac
Calugareni
180
160
140
120
100
80
60
40
20
0
Cheia
NO3
m g/l
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 42 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Fata de situatia prezentata privind calitatea apei in principalele acvifere utilizate pentru
alimentarea cu apa din judetul Constanta, solutile posibile pentru imbunatatirea calitatii
apei sunt :
- pentru captarile care exploateaza acviferul de adancime jurasic dezvoltate in Dobrogea
de Sud, unde depasirile in nitrati sunt mai rar intalnite, datorate unor conditii locale sau
deficiente de executie a forajelor cu izolare necorespunzatoare a stratelor superioare
(Deleni, V. Traian) :
-
- pentru captarile care exploateaza acviferul de medie adancime din cretacic, dezvoltate in
la sud de falia Capidava-Ovidiu :
-
sursa noua de apa care sa capteze acviferul jurasic de adancime. Solutia nu este
valabila in partea de sud-est a judetului unde acviferul jurasic de adancime are un
continut ridicat de hidrogen sulfurat, zona limitata la vest de o linie care trece
aproximativ prin localitatile Lazu, Cumpana, Topraisar, Amzacea, Cotu Vaii.
- pentru captari care exploateaza acviferul freatic din depozitele cuaternare, dezvoltate in
Dobrogea Centrala la nord de falia Capidava-Ovidiu:
-
- 43 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Bibliografie
Victor Moldoveanu Studiul conditiilor hidrogeologice ale Dobrogei de Sud pentru reevaluarea resurselor
exploatabile, Teza de doctorat,1008, Universitatea din Bucuresti.
Kim Rudolph-Lund, Florian Zamfirescu Pilot Study of Romanias Dobrogea aquifer to asist in implementation
of the ECs environmental directives 2000/60/EC (Water Framework Directive) and 1999/31/EC
(Landfill Directive), ianuarie, 2006.
Hidroedil S.A. Bucuresti, Fluid Serv S.A. Constanta, - Studiu hidrogeologic pentru delimitarea zonelor de
protectie ale surselor de apa ale RAJA Constanta, conform HG 930/2005, Noembrie 2006.
Romproed S.A. Bucuresti, Fluid Serv S.A. Constanta, - Studii de oportunitate pentru reducerea nitratilor din
apa potabila pentru 22 localitati rurale din jud. Constanta, 2007.
- 44 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Optarea pentru una sau alta din cele dou soluii, are la baz analiza sistemului,
respectiv a sursei de ap.
Ideal, (din punct de vedere economic i administrativ) ar fi ca fiecare localitate s
beneficieze de surs proprie de ap (de preferat din surs de adncime care s elimine
mcar parial necesitatea tratrii apei), i n acest caz opiunea ar fi n sensul gestionrii
fiecrui sistem centralizat de ctre un operator unic situat n zon.
Realitatea, cu care ne confruntm n ultima perioad din ce n ce mai acut, este cea a
dificultii gsirii unor surse de ap care s corespund cantitativ i calitativ cerinelor.
n acest sens se poate cita ca exemplu municipiul Iai a crui prim surs important
de ap este la Timieti (captare prin drenuri i puuri), la o distan de peste 100 km.
Apa provenit din aceast surs este de bun calitate, dar limitat la un debit
exploatabil de max. 1,8 m3/s.
Avnd n vedere c sursele de adncime sunt punctuale, au n general debit redus,
nepretndu-se la o exploatare centralizat sistemic (macro sau microzonal), singurele
surse exploatabile sunt cele de suprafa (n cazul jud. Iai din rul Prut), care de altfel se
constituie n a doua surs de alimentare a municipiului Iai.
Necesarul de ap al municipiului Iai n etapa de perspectiv 2025 este de circa 3,5
m3/s, din care 1,5 m3/s din sursa Timieti i 2,0 m3/s din sursa Prut.
innd cont de faptul c n prezent de la sursa Prut se poate livra municipiului Iai (la
o distan de circa 12 km) un debit de ap brut de 3,5 m3/s, i c de curnd s-au finalizat
lucrrile la staia de tratare Chiria pentru un debit de 2,6 m3/s din sursa Prut, rezult un
disponibil de ap potabil de 0,6 m3/s, posibil de a fi livrat consumatorilor funcie de
necesiti.
- 45 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Comuna Romneti
Comuna ignai
Comunele
i Bivolari
Localitate sediu
comun Vldeni
Comunele ipote i
Plugari
Comunele Movileni,
Gropnia, Probota i
Trifeti
- 46 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Varianta VI
Alimentarea cu ap din dou surse: orogari Iai, pentru 8 comune, respectiv Sculeni
(Victoria), pentru 4 comune, prin extinderea staiei de tratare existent de 15 l/s cu nc 40
l/s.
Varianta VII
Alimentarea cu ap din dou surse:Sculeni (se menine alimentarea existent pentru 2
din cele 3 localiti ale comunei ignai), i orogari Iai pentru 11 comune, cu conduct
de legtur ntre cele 2 ramuri ale sistemului.
Varianta VIII.a
Alimentarea cu ap din 3 surse:
-
Sculeni
Lunca Prut
Varianta VIII.b
Este o subvariant a variantei III, constnd ntr-un traseu alternativ al conductei de
aduciune pe ramura N-V cu modalitate diferit de realizare a alimentrii cu ap pentru
localitile Bora, Vlcele i M. Koglniceanu.
Varianta VIV
Const n propunerea alimentrii cu ap a celor 12 comune din surs unic orogari
Iai.
Sursa existent Sculeni va alimenta comuna Victoria (pentru care a fost proiectat), i
localitatea Cotu Morii din zon, pentru care exist capacitate disponibil n staia de
tratare existent.
Obiectivele existente ale alimentrii comunei ignai (rezervor nmagazinare,
distribuie), se vor ntegra n schema de alimentare a variantei propuse.
Varianta VV.a
Propune alimentarea cu ap din 4 surse:
meninerea alimentrii existente (idem Varianta VIII);
Sculeni
- 47 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Lunca Prut
Varianta VV.b
Subvariant a variantei V.a, constnd n traseu alternativ al conductei de aduciune pe
ramura N-V (similar subvariantei III.b).
n urma analizei multicriteriale ce a inut cont de: lungimea traseului, numrul
locuitorilor deservii, volumul capacitii de nmagazinare, consumul energetic precum i
flexibilitatea sistemului, a rezultat ca optim din punct de vedere al variantelor analizate
varianta VIV.
LEGENDA
Conduct aduciune existent
Conduct aduciune propus
Figura 1 Zon jude Iai propus a fi alimentat n sistem macrozonal (12 comune)
- 48 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 49 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 50 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Figura 10 Subsisteme
- 51 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Nr.
Crt.
Comuna
Nr. locuitori
Popricani
9.498
11.197
25,89
34,55
2
3
4
Romneti
Movilemi
Gropnia
2.188
3.119
3.356
2.415
3.677
3.956
8,15
8,74
9,54
11,8
11,16
12,15
Vldeni
4.500
5.305
12,35
17,55
67
ipote+Plugari
9.051
10.000
21,07
25,07
Andrieeni
4.500
5.306
12,78
17,54
9
10
11
ignai
Probota
Trifeti
4.879
3.921
5.000
5.610
4.623
5.895
13,1
10,62
13,81
17,52
14,15
18,98
12
Bivolari
4.500
5.205
12,39
17,88
TOTAL
54.512
63.189
139,34
187,43
2008
Qa (l/s)
2035
2010
2035
- 52 -
Observaii
Nu are sistem centralizat de alimentare cu ap. S-a elaborat un
Studiu de fezabilitate pentru alimentarea comunei cu ap potabil.
S-a preluat modalitatea de rezolvare a problemei.
Comun alimentat din sursa Timieti.
Nu are sistem centralizat de alimentare cu ap.
Nu are sistem centralizat de alimentare cu ap.
Localitatea Vldeni dispune de sistem de alimentare cu ap n
sistem centralizat, din surs n curs de eutrofizare accentuat.
Comune alimentate n sistem centralizat din acumularea Hlceni
(sursa Vldeni) aflat n prezent n curs de eutrofizare.
Comuna este n prezent alimentat din sursa Stnca Costeti, jud.
Botoani cu o aduciune de circa 50km.
Comuna alimentat din sursa Sculeni.
Nu are sistem centralizat de alimentare cu ap.
Nu are sistem centralizat de alimentare cu ap.
Comun alimentat din sursa Stnca Costeti, jud. Botoani
printr-o aduciune de circa 50km.
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Lungimi (km)
Variante
Aduciuni
Interconectri
OBSERVAII
TOTAL
VI
192,55
27,6
220,15
VII
184,85
30,8
215,65
VIII-a
185,65
25,8
211,45
VIII-b
183,90
25,8
209,70
VIV
189,60
16,0
205,60
VV-a
158,0
48,8
206,80
VV-b
155,05
48.8
203,85
- 53 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Nr.
Crt.
Varianta
VI
VII
VIII.a
Sursa
VIII.b
VIV
VV.a
orogari
1.822.262
2.535.874
0,496
0,612
820.885
1.201.726
0,6348
1,189
0,7467
1,212
orogari
Sculeni
(existent)
2.490.066
3.516.921
153.117
220.679
0,7954
1,7467
1,021
1,645
orogari
1.822.265
2.535.874
0,5266
0,64
667.804
981.047
1,259
1,24
153.117
220.679
1.737.911
2.420.607
1,7467
0,671
1,645
0,799
667.804
981.047
1,259
1,2408
237.505
335.946
1,30295
1,2085
2.643.220
1.599.649
3.737.600
2.210.002
438.985
640.538
0,6334
0,45
1,38254
0,763
0,54846
1,4418
220.679
1,746
1,6446
Sculeni
(extindere)
Lunca Prut
Lunca Prut
Sculeni
(existent)
orogari
orogari
Sculeni
(existent)
orogari
Lunca Prut
VV.b
mediu pe sistem
Stnca
Costeti
jud.Botoani
pe surse
2035
Lunca Prut
6
2010
Sculeni
(existent)
orogari
4
Volum ap livrat
(m3/an)
153.117
451.432
666.380
1.515.298
2.094.735
438.985
640.558
Sculeni
(existent)
237.505
335.946
Stnca
Costeti
jud.Botoani
451.432
666.380
2010
5
2035
6
fr
consumurile
energetice
necesare tratrii i
aduciunii
0,592
0,699
1,3725
1,382
1,2085
1,303
fr
consumurile
energetice
necesare tratrii i
aduciunii
2010
7
2035
8
0,7113
0,805
0,85
1,0578
0,7824
0,857
0,87636
0,95186
0,6334
0,768
0,7276
0,81355
0,82735
0,8954
NOT:
Coloanele 5 6 au la numrtor consumul energetic exclusiv cel din staia de tratare
iar la numitor consumul total.
Valorile coloanelor 5 8 nu cuprind consumurile energetice necesare aduciunii i
tratrii apei din sursa orogari Iai, la nici una din variante.
- 54 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
CONCLUZII
n urma analizrii celor 7 variante i subvariante, au rezultat o serie de observaii, ce se pot
extrapola la macrosistemele de alimentare cu ap zonale.
-
- 55 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Introducere
Resursele naturale de apa subterana, in special cele cantonate in acviferele freatice sunt
supuse unui risc ridicat de poluare cu nitrati cu precadere in zonele rurale, cauzele fiind
cunoscute: administrarea incorecta a fertilizantilor, depozitare neconforma a deseurilor,
prezenta unor surse locale de infestare (grajduri de animale, WC-uri amplasate in
apropierea fantanilor etc). Conform OMMGA 241/2005, un numar important de localitati
(zone rurale) din diverse spatii/bazine hidrografice se confrunta cu acest tip de poluare:
sh.Somes-Tisa, sh.Crisuri, sh.Mures, sh.Banat, bh. Jiu, bh.Siret, sh.Arges Vedea, sh.BuzauIalomita, sh.Siret, sh.Prut-Barlad.
Consumul de apa cu continut ridicat de nitrati este asociat cu un numar semnificativ de
afectiuni grave, dintre care se mentioneaza methemoglobinemia acuta infantila, diverse
forme de cancer (bucal, rectal, gastrointestinal, de colon), maladia Alzheimer, scleroza
multipla, hipertrofie tirodiana etc (Comly, 1987; Forman et al., 1985).
La nivel national nu exista statii/instalatii de potabilizare a surselor subterane poluate cu
nitrati.
Procesele fizico-chimice care pot conduce la eliminarea/diminuarea nitratilor din apa sunt
schimbul ionic, osmoza inversa, electrodializa si reducerea chimica/catalitica. Conform
datelor prezentate de Agentia de Protectia Mediului din USA (USEPA 1995), cele mai bune
tehnologii disponibile (BAT) pentru indepartarea nitratilor din sursele destinate consumului
uman sunt schimbul ionic, electrodializa si osmoza inversa (Soares et al., 2000). In Europa
s-au studiat si aplicat procese biologice de denitrificare anaeroba (produs final azot), atat
cele heterotrofe care folosesc sursa externa de carbon (etanol, acid acetic, glucoza, derivati
celulozici) cat si cele autotrofe, care utilizeaza ca donor de electroni sulf sau hidrogen (Darbi
et al., 2003; Buttiglieri et al., 2005).
La ora actuala, sunt in curs de dezvoltare procesele chimice alternative la BAT, avand in
vedere unele dezavantaje prezentate de acestea din urma: consumuri energetice ridicate
pentru electrodializa si osmoza inversa, dependenta eficientei de matricea de impurificare, in
special in cazul electrodializei si schimbului ionic, generarea unor solutii reziduale
concentrate in ioni nitrat (osmoza inversa, schimb ionic). Procesele alternative chimice se
bazeaza pe reducerea ionului nitrat in prezenta de Feo/CO2, cu formare de ioni amoniu
(indicator limitat de L 458/02 la 0,5 mg/l) precum si de denitrificare partiala in prezenta de
radiatii UV, cu generare de azotiti (Ruangchainikom et al., 2005).
Cercetarile de data recenta in domeniul proceselor biologice incearca sa evalueze
posibilitatea utilizarii surselor de carbon organic solid, care are rol atat de matrice suport
- 56 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Parte experimentala
Premisele care au stat la baza abordarii cercetarii sistematice in vederea dezvoltarii unei
filiere de tratare pentru ape subterane cu continut de azotati au fost urmatoarele:
- 57 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
(substante organice, turbiditate, nitriti, celule bacteriene etc.). In acest sens, s-a impus
pozitionarea in filiera de tratare a unei trepte de filtrare a efluentului treptei de denitrificare pe
carbune activ (carbune PICABIOL suprafata specifica 1500 m2/g). S-a lucrat in sistem
dinamic (timp de contact 1030 minute) in coloana cu umplutura de carbune activ, cu
aerarea prealabila a influentului.
Rezultate si discutii
Experimentari de denitrificare heterotrofa
Perioada de amorsare s-a considerat terminata dupa stabilizarea concentratiilor de azotati si
azotiti in efluent (NO3- 40 mg/l, NO2- < 0,2 mg/l) si implicit dezvoltarea peliculei biologice
la suprafata suportului.
Analiza microscopica a biocenozei dezvoltate pe suportul de bumbac a relevat, dupa
incheierea perioadei de insamantare/aclimatizare, urmatoarele aspecte:
prezenta ciliatelor libere Litonotus sp. si Euplotes sp., cu rol in limpezirea efluentului
foto 1.1., 1.2.;
aparitia rotiferilor.
- 58 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
50
45
Y1-NO3-
40
Y2-NO2-
Y3-CCOCr
35
mg/l
30
25
20
15
10
5
0
0
10
15
20
25
30
35
40
45
50
Zile
- 59 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
pH = 7,76;
Apa tratata nu contine germeni patogeni, iar incarcarea organica remanenta (TOC 0,5
mg C/l) se situeaza sub valoarea nominalizata pentru asigurarea unui continut remanent de
THM sub 100 g/l.
Rezultatele experimentale obtinute la nivel micropilot au demonstrat posibilitatea de
indepartare a nitratilor din resurse naturale de apa subterana, fluxul de tratare elaborat
(fig.1.2) avand in componenta urmatoarele trepte:
aerare;
dezinfectie cu clor/ClO2.
- 60 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
apa bruta
NO3- 100 mg/l
Sursa de fosfor
anorganic (dupa caz)
DENITRIFICARE ANAEROBA
(bioreactor cu suport fibra
celulozica/bumbac)
TRH 24 h
Aer tehnologic
AERARE
O2diz. 7 mg/l
Cl2 /ClO2
SORBTIE/BIOSORBTIE
CARBUNE ACTIV
20 min
DEZINFECTIE
Apa potabila
Figura 1.2. Schema flux tehnologic de tratare ape subterane cu continut de azotati
(surse foarte incarcate)
Concluzii
Experimentarile efectuate la nivel micropilot confirma eficienta procesului dedenitrificare
heterotrofa pentru indepartarea ionului azotat (sute mg/l) din resurse naturale, avantajele
procesului fiind urmatoarele:
operarea in sistem biofiltru anaerob, fara consum de energie;
utilizarea unei surse externe de carbon solide, care nu necesita dozare avand
si rol de suport pentru dezvoltarea biomasei specifice proceselor de
denitrificare;
produsul final de denitrificare este azotul gazos, cu caracter netoxic.
Ca dezavantaj major, specific de altfel tuturor proceselor biologice heterotrofe, se
mentioneaza cresterea incarcarii organice biodegradabile in faza solubila, datorita
actiunii bacteriilor celulozolitice asupra suportului de celuloza.
Incarcarea organica remanenta biodegradabila se indeparteaza prin adsorbtie/ biosorbtie
pe carbune activ, dupa aerarea prealabila a efluentului treptei de denitrificare anaeroba.
Apa tratata in fluxul de denitrificare heterotrofa si adsorbtie/biosorbtie pe carbune activ se
incadreaza in normele de calitate impuse pentru indicatorii fizico-chimici de legislatia in
vigoare, necesitand tratare finala cu clor sau ClO2 pentru dezinfectie.
- 61 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Referinte bibliografice
Comly, H.H. (1987) Cyanosis in infantes caused by nitrate in well water. Journal of the American Medical
Association 257, 2788-2792
Forman, D., Al-Dabbagh, S. and Doll, R. (1985) Nitrates, nitrites and gastric cancer in Great Britain. Nature 313,
620-625.
Soares, M.I.M., Brenner, A., Yevzori, A., Messalem, R., Leroux, Y. And Abeliovich, A. (2000) Biological
denitrification of groundwater. Water Air&Soil Pollut, 123, 183-193.
Buttiglieri, G., Malpei, F. (2005) Denitrification of drinking water source by advanced biological treatment.
Desalination 178, 211-218.
Darbi, A., Viraraghavan, T., Butler, R., and Corkal, D. (2003) Column studies on nitrate removal from potable
water. Water, Air&Soil Pollut 150, 235-254.
Ruganchainikom, C., Liao, C.H., Antotai, Y., and Lee, M.T. (2005) Innovative process using Feo/CO2 for the
removal of nitrate from groundwater. Water Sci&Technol: Water Supply 5(5), 41-48.
Della Roca, C., Belgiorno, V., and Meric, S., (2005) Cotton supported heterotrophic denitrifcation of nitrate rich
drinking water with a sand filtration post-treatment. Water SA, 31(2), 229-236.
- 62 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Abstract
This study treats the problem of surface and ground water used in the water supply systems,
in order to process the water and make it drinkable, regarding the characteristics of the water
sources used in the water treatment plants.
The spectacular increase of the water demand in the contemporary society results in the
use of often very polluted water sources for the supply of the consumers living in
communities with less than 10,000 inhabitants, while treatment conditions remained the
same, or are slightly upgraded, not enough to reach maximum performances.
The study wants to be a warning on the necessity to use these waters at the indicator
parameters in the water categories used for water treatment, as there are risks for human
health in case of long-term use of drinking water of a certain chemical composition .
Pentru alimentarea cu apa a Judetului Iasi si a localitatilor cu pana la 10,000 locuitori sunt
utilizate urmatoarele surse naturale care se disting intre ele prin caracteristicile calitative,
regimul de curgere si posibilitati de captare si tratare:
surse de apa de suprafata, care sunt constituite din ape curgatoare: rauri raul Prut,
afluenti, lacuri naturale si artificiale lacul Chirita si acumularile de la Prcovaci , Belcesti,
Tungujei, Halceni...
surse de apa subterana sursa Timisesti si toate sursele proprii de apa existente care
vor fi prezentate ulterior.
- 63 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
sedimentare a materiilor in suspensie, viteza unor reactii chimice sau intensitatea proceselor
metabolice ale bacteriilor sau organismelor acvatice.
Dintre factorii fizici, cei mai importanti sunt: sedimentarea, lumina, temperatura, regimul
de curgere a apei (care influenteaza direct procesele de amestec si viteza de aerare).
Dintre factorii chimici, oxigenul dizolvat detine cel mai important rol, prin influenta sa in
procesele biologice de descompunere a materiei organice sau in procesele de oxidare
chimica.
Oxigenul introdus in apa prin aerare naturala sau produs de catre plantele acvatice, are
un rol esential in mentinerea vietii ecosistemului, cantitatea minima de oxigen dizolvat
necesara existentei vietii acvatice fiind de 4mg/l. Deficitul de oxigen se determina ca fiind
diferenta dintre concentratia de saturatie si concentratia existenta de oxigen, ambele
determinate la aceeasi temperatura a apei.
Bioxidul de carbon, CO2, este sursa principala de carbon pentru plante acvatice si se
poate identifica sub forma libera sau de carbonati si de bicarbonati de calciu sau magneziu.
Apele, continand bicarbonati de calciu, formeaza un sistem tampon cu mare capacitate de
neutralizare a acizilor si bazelor.
Dintre factorii biologici, bacteriile au cel mai important rol datorita caracteristicilor
metabolismului lor (multiplicare extrem de rapida intr-un timp foarte scurt) si datorita faptului
ca utilizeaza compusi organici sau anorganici poluanti, pentru a produce material celular
nou, energie si produsi de degradare inofensivi (CO2, N2,SO22-, H2O, NO3).
In procesele bacteriene aerobe sau anaerobe, sub actiunea enzimelor, poate fi degradata
o varietate de compusi, cum ar fi: proteine, hidrati de carbon, grasimi, uree, o parte din
compusii organici de sinteza, rezultand compusi mai simpli cu toxicitate redusa.
In afara de bacterii, un rol deosebit in autoepurare il mai au protozoarele (ciliate,
flagelate), care mentin echilibrul biologic prin ingerarea bacteriilor, macrovertebratele
(spongieri, lamele branhiate), care au rol de filtrare a apei, aerare si irigare a malului si plante
clorofiliene care produc oxigen prin fotosinteza.
Obisnuit, autoepurarea apelor curgatoare poluate, intr-o singura repriza se realizeaza in
circa 10 zile, eliminandu-se inclusiv germenii patogeni. Distrugerea germenilor patogeni este
consecinta faptului ca acestia nu beneficiaza in apa de conditii de viata si multiplicare,
inregistrand astfel fenomene de imbatranire si atenuare a patogenitatii.
De asemenea, distrugerea se datoreaza antagonismelor si concurentei cu alte
organisme, precum si faptul ca sunt ingerate de catre alte organisme acvatice actiune
bacterivora. Se mentioneaza, de asemenea, actiunea litica a fagilor, care duce la distrugerea
germenilor.
In general, autopurificarea apelor de suprafata nu este suficienta pentru a asigura
conditiile de calitate necesare unei ape potabile, impunand un tratament adecvat al acesteia.
Raurile sunt caracterizate de prezenta urmatoarelor impuritati existente in stare naturala,
compozitia specifica fiind dependenta de natura solurilor traversate de cursul de apa, a
solurilor din bazinul de receptie, a apelor uzate deversate de diferiti utilizatori si a
capacitatilor de dizolvare a gazelor din atmosfera:
saruri dizolvate: bicarbonati, cloruri, azotati, fosfati, sulfati de : Na+, K+, Mg2+, Ca2+,
- 64 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
detergentii;
Unitate de masura
Valori obtinute
Valori admise
ml HCl
mg/l
mg/l
mg/l
3,7
0,05
8
36
2
50
200
unitati pH
factori dilutie la 25C
Ge
mg/l
mgO2/l
mg/l
mg/l
S/cm
UNT
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
7,8
1
12,77
0
2,5
8
105
423
0,03
0
0,003
0,0002
0
0,05
0,0006
5,5 - 9,0
10
5
0,05
30
25
250
1000
5
0,1
0,05
0,005
0,001
0,5
0,005
In urma rezultatelor obtinute se constata ca apa din raul Prut indeplineste conditiile apelor
de suprafata si poate fi utilizata in sistemele de alimentare cu apa.
Localitatile din zona judetului Iasi care folosesc surse de apa de suprafata pentru sisteme
de alimentare cu apa si canalizare in localitati cu pana la 10.000 locuitori, sunt : Aroneanu,
Dorobanti ; Bivolari, Andrieseni ; Harlau : Parcovaci, Ceplenita ; Belcesti : Coarnele Caprei,
Focuri, Tansa, Satu Nou ; Gorban : Raducaneni, Scoposeni, Isaia, Bohotin ; Sculeni :
Victoria, Sendreni, Luceni, Icuseni ; Tibanesti : Tungujei, Tansa, Suhulet, Razboieni, Glodenii
Gandului ; Vladeni : Chiscareni, Sipote, Mitoc, Halceni, Iazu Nou.
1.2 Lacurile naturale si artificiale
Lacurile - lacul Chirita, si acumularile Parcovaci, Belcesti, Tungujei, Halceni sunt formate prin
bararea naturala sau artificiala a unui curs de apa, fiind complet inconjurate de suprafete
uscate.
Lacurile se caracterizeaza printr-o suprafata de contact apa apa atmosfera cvasi
imobila si prezinta modificari ale indicatorilor de calitate comparative cu efluentul principal,
datorita fenomenelor de stagnare a apei si de stratificare (vara si iarna) si respectiv de
- 65 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
destratificare (primavara si toamna). Aceste fenomene se manifesta atat din punct de vedere
termic, cat si al compozitiei apei in lac.
Stagnarea apei in lacuri (lipsa circulatiei apelor), conduce la decantarea naturala a
materiilor in suspensie si partial a celor coloidale. Stratificarea termica si minerala in lacuri se
datoreaza diferentei de temperatura, densitate si respectiv adancimii lacurilor.
Densitatea apelor influentata in mod direct de temperatura (densitatea maxima a apei la
40C, se atinge, de obicei, la partea inferioara a lacului, la suprafata temperatura fiind mai
ridicata sau mai coborata, dupa anotimp) conduce la o separare de natura fizica a masei de
apa, separare care influenteaza ulterior si procesele fizice, chimice si biologice care au loc in
lacuri (Rojanschi, 1996).
Stratificarea termica, combinata la lacurile adanci si cu o stratificare minerala, conduce
vara si iarna, la excluderea completa a circulatiei apei pe verticala. Efectele directe ale
stratificarii sunt:
saruri minerale;
nutrienti;
biomasa;
microorganisme.
- 66 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
aparitia unei coloratii specifice (verzuie). Procesul de eutrofizare evolueaza in trei faze:
oligotrofa, mezotrofa si eutrofa, denumirea acestor faze generand si denumirea specifica
lacurilor.
Astfel, lacurile oligotrofe (lacurile tinere) sunt albastre si transparente, avand un continut
redus de biomasa si o saturatie in oxigen de aproximativ 70 %. Fitoplanctonul cuprinde in
special diatomee si alge verzi. Lacurile mezotrofe sunt caracterizate de imbogatirea in
substante nutritive care contribue la cresterea productivitatii biologice si, respectiv, a
concentratiei compusilor organici biogeni (rezultati prin descompunerea materiei vegetale si
animale). Lacurile eutrofe se caracterizeaza printr-un continut foarte mare de nutrienti, o
dezvoltare biologica foarte rapida (predomina algele albastre), deficit de oxigen in straturile
inferioare (saturate in oxigen sub 10%) si o imbogatire a acestora in materii organice.
Trecerea lacurilor de la un stadiu la altul se realizeaza intr-un timp indelungat, de ordinul
sutelor de ani. Acest fenomen este accelerat datorita activitatii umane, prin deversare de
efluenti cu un aport mare de nutrienti si compusi organici.
Acumularea compusilor poluanti toxici in sedimente, cu influente directe asupra
proceselor de bio-acumulare si bio-magnificare in lantul trofic. Majoritatea compusilor
poluanti toxici de natura organica sau anorganica, cu solubilitate redusa in apa, sunt
preferential adsorbiti de particulele solide, de origine anorganica sau biologica, care se
regasesc in sedimentele din lacuri. O parte din acesti compusi toxici este preluata de catre
organismele acvatice si incorporate in lantul trofic. Riscurile contaminarii oamenilor cu
poluanti, cum ar fi: pesticide, metale grele, apar ca urmare a consumarii pestilor din aceste
lacuri.
Acidifierea lacurilor este datorata ploilor acide, a caror aparitie este legata in principal de
arderea combustibililor fosili si generarea de oxizi de sulf si azot, oxizi care in combinatie cu
precipitatiile atmosferice, conduc la formarea acizilor sulfuric si azotic. In afara existentei
precipitatiilor cu caracter acid, o conditie esentiala in acidifierea lacurilor o constitue
continutul scazut al acestora in saruri dizolvate si in special, in saruri de calciu si magneziu .
Apele de suprafata se clasifica, in functie de valorile limita in 3 categorii : A1, A2, A3.
Fiecarei categorii ii corespund o tehnologie standard adecvata de tratare :
A1 - Trarare fizica simpla si dezinfectie( ex : filtrare rapida si dezinfectie) ;
A2 - Tratare normala fizica, chimica si dezinfectie [ex : preclorinare, coagulare,
floculare, decantare, filtrare, dezinfectie (clorinare finala)] ;
A3 - Tratare fizica, chimica avansata, perclorare si dezinfectie [ex : clorinare
intermediara, coagulare, floculare, decantare, filtrare prin adsorbtie (pe carbune activ),
dezinfectie (ozonizare, clorinare finala)].
- 67 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Parametri
1
3
4
pH
Coloratie (dupa filtrare
simpla)
Materii in suspensie, total
Temperatura
5
6
Conductivitate
Culoare
Azotati
8
9
Fluoruri
Compusi organici cu clor,
extractibili, total
Fier dizolvat
Mangan
Cupru
Zinc
Bor
Beriliu
Cobalt
Nichel
Vanadiu
Arseniu
Cadmiu
Crom total
Plumb
Seleniu
Mercur
Bariu
Cianuri
Sulfati
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
Cloruri
Agenti
de
suprafata
anionici (prin metoda
spectrometrica
cu
albastru de metilen)
Fosfati
Fenoli (indice fenolic) pnitroanilina 4
aminoantipirina
Hidrocarburi
dizolvate
sau in emulsie (dupa
extractia cu eter de
petrol)
Hidrocarburi
policiclice
aromatice
Pesticide totale (paration,
HCH, dieldrin)
Consum
chimic
de
oxigen (CCO)
Gradul de saturatie in
oxigen dizolvat
Consum biochimic de
oxigen (CBO5) (la 20C,
fara nitrificare)
Azot Kjeldahl (fara NO 3
Unitatea
de masura
2
unitati pH
mg/l pe scara
Pt
mg/l
C
A1
G
3
6,5-8,5
10
25
22
A2
I
4
A3
20 (O)
G
5
5,5-9
50
I
6
100
25 (O)
22
25 (O)
1000
10
G
7
5,5-9
22
I
8
25
(O)
S/cm
(factor de dilutie
la 250C)
mg/l
1000
3
25
50 (O)
mg/l
mg/l
0,7 la 1
1,5
0,7 la 1
1,7
0,7 la 1
50
(O)
1,7
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
0,1
0,05
0,02
0,5
1
0,3
1
0,1
0,05
1
1
1
1
1
1
0,05 O
3
1
50 (O)
0,05
0,01
0,001
0,0005
150
0,05
0,005
0,05
0,05
0,01
0,001
0,1
0,05
250
1000
20
0,05
0,001
0,0005
150
0,05
0,005
0,05
0,05
0,01
0,001
1
0,05
250 O
0,1
0,05
0,001
0,0005
150
mg/l
200
200
200
mg/l
0,2
0,2
0,2
mg/l
0,4
0,7
0,7
mg/l
0,001
mg/l
0,001
0,1
0,005
0,05
0,05
0,01
0,001
1
0,05
250
(O)
0,005
0,01
0,1
0,05
0,2
0,5
mg/l
0,0002
0,0002
0,001
mg/l
0,001
0,0025
0,005
mg O2 /l
10
20
30
% O2
> 70
> 50
> 30
mg O2 /l
<3
<5
<7
mg/l
- 68 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
43
44
45
Amoniu (NH+4)
Substante extractabile in
cloroform
Carbon organic total
Carbon organic rezidual
dupa floculare si filtrare
pe membrana (5) TOC
Coliformi totali la 37 C
Coliformi fecali
Streptococi fecali
46
Salmonella
39
40
41
42
mg/l
mg/l
0,05
0,1
1
0,2
50
20
20
Absent
in
5.000
ml
5.000
2.000
1.000
Absent
in
5.000
ml
1,5
2
0,5
4 O
mg/l
mg/l
/100ml
/100ml
/100ml
50.000
20.000
10.000
I = valori obligatorii
G = valori orientative
O = conditii climatice si geografice exceptionale
straturi acvifere freatice de mica adancime (pana la 20 m), cantonate in roci granulare
sau fisurate :
-
fara influenta directa a unei ape de suprafata, alimentate din bazine subterane intinse;
straturi acvifere de mare adancime, cantonate in roci granulare si roci fisurate, la adancimi
mari (100-500 m). De cele mai multe ori, apa aflata in aceste straturi se afla sub presiune,
avand caracter ascensional. Aceste straturi sunt alimentate de la distante mari, din diferite
bazine hidrologice.
straturi acvifere alimentate prin infiltratii artificiale in scopul imbogatirii stratului de apa
subteran. Aceste straturi sunt cantonate in roci granulare, nisip si pietris. Infiltratiile artificiale
se realizeaza, de obicei, prin aportul apelor de suprafata (rauri, lacuri, acumulari).
izvoare, provenite din straturi acvifere aflate sub nivelul panzei de apa subterana, care
sarurile dizolvate (in concentratie mai mare fata de apele de suprafata, de aprox 400
mg/l).
Principalele saruri sunt: bicarbonatii, clorurile, sulfatii, azotatii de Na+, K+, Ca2+, Mg2+,
Fe2+, Mn2+), dar compozitia chimica depinde mult de compozitia mineralogica.
- 69 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
microorganisme.
Sursele de apa subterana, datorita calitatii lor, sunt preferate surselor de suprafata,
principala problema constituind-o, insa, cantitatea de apa care poate fi furnizata
consumatorilor, insuficienta, mai ales, pentru alimentarea cu apa a oraselor mari.
Modurile de alegere a sursei in vederea alimentarii cu apa potabila sau industriala sunt
de natura:
calitativa: trebuie cunoscuta compozitia apei la sursa, pe categorii de impurificatori de
natura biologica, minerala, organica si radioactiva, cauzele posibile de poluare si
imbunatatirile artificiale sau tratari, daca este posibil , chiar in zona de aductiune/captare, la
priza;
economica: costul minim pe metru cub de apa este corelat cu calitatea sursei si necesarul /
gradul de tratare. Costul include: costurile de investitii pentru toate instalatiile si anexele de
tratare, costurile de operare si executie, cheltuielile cu resursele umane si toate costurile
indirecte.
Localitatile din zona judetului Iasi care folosesc surse de apa subterana pentru sisteme
de alimentare cu apa si canalizare in localitati cu pana la 10.000 locuitori, sunt : Valea
Lupului ; Letcani : Bogonos, Cogeasca ; Turn Sabaoani ; Strunga : Cucova, Habasesti,
Farcaseni, Bratulesti ; Butea ; Tamaseni, Sabaoani ; Pastraveni ; Targu Frumos ; Braiesti :
Lungani, Razboieni ; Podu Iloaiei, Scobalteni, Pietrarie, Paun, Cercu.
Localitatile din zona judetului Iasi cu surse proprii de apa sunt : Golaiesti, Repedea,
Verseni, Ciohorani, Mitesti, Soci, Miroslovesti, Mircesti, Halaucesti, Luncasi, Rachiteni,
Ursaresti, Izvoare, Scobinti : Zagavia, Fetesti, ; Deleni, Poiana, Maxut, Siretel, Lespezi,
Gropnita : Bulbucani, Sanger, Saveni, Malaesti.
2.1 Parametrii de calitate ai apei potabile
Parametrii de calitate a apei sunt microbiologici, chimici si indicatori.
Apa pentru a putea fi consumata in siguranta trebuie sa respecte limitele admise a
parametrilor din Legea 458 / 2002 Legea calitatii apei potabile
Valorile concentratiilor maxime admise pentru parametrii de calitate ai apei potabile sunt
cele prevazute in tabelele :
Tabel 3 Parametri microbiologici
Parametrul / Unitatea de masura
Escherichia coli (E. coli)/ 100ml
Enterococi (Streptococi fecali)/ 100ml
Valoarea
admisa
0
0
- 70 -
Metoda de analiza
ISO 9308-1
STAS 3001/1991: ISO 7899-2
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
g/l
g/l
g/l
g/l
mg/l
g/l
g/l
g/l
g/l
Cupru
mg/l
Cianuri (totale)
g/l
Cianuri (libere)
g/l
Dicloretan
g/l
Epiclorhidrina1)
g/l
Fluor
mg/l
4)
Hidrocarburi policiclice aromatice g/l
Mercur
g/l
Nichel3),5)
g/l
6)
Nitrati
mg/l
6)
Nitriti
mg/l
Pesticide7),8)
g/l/clasa
Pesticide7),9)
g/l/Total
3),10)
Plumb
g/l
Seleniu
g/l
Stibiu
(g/l
Tetracloretan si Tricloretena g/l
concentratiilor compusilor specificati)
1)
Trihalometani
g/l/Total (suma
concentratiilor compusilor specificati)
100
STAS 12997/91
*) Metode de analiza care nu sunt acoperite de standarde romanesti (STAS) sau ISO ori care nu sunt preluate ca
standarde romanesti (SR ISO) si care urmeaza sa fie stabilite ulterior.
NOTA:
1)
Valoarea se refera la concentratia in apa a monomerului rezidual, calculata conform specificatiilor privind
concentratia maxima eliberata de catre polimer in contact cu apa. Statiile de tratare vor notifica autoritatii de
sanatate publica judetene, respectiv a municipiului Bucuresti, utilizarea compusului in procesul de tratare a apei
pentru potabilizare.
2)
Unde este posibil, valoarea concentratiei trebuie sa fie cat mai joasa, fara a compromite eficienta dezinfectiei.
Pentru apa la care se refera respectarea in practica a valorii se va realiza in maximum 10 ani de la intrarea in
vigoare a prezentei legi, in primii 5 ani acceptandu-se o valoare de 25 g/l.
3)
Pentru cupru se accepta valoarea de 2,0 mg/l, daca reteaua de distributie are componente din cupru.
4)
Valoarea se aplica la o proba de apa prelevata de la robinetul consumatorului printr-o metoda de prelevare
adecvata, astfel incat sa fie reprezentativa pentru cantitatea medie saptamanala ingerata de catre consumator.
Metoda de monitorizare trebuie sa tina seama si de frecventa concentratiilor maxime care pot cauza efecte
asupra sanatatii.
5)
Compusii specificati sunt: benzo(b)fluorantren, benzo(k)fluorantren, benzo(ghi)perilen, indeno(1,2,3-cd)piren.
6)
Se va aplica urmatoarea formula:
nitrat/50 + nitrit/3
1, in care concentratiile de nitrati si nitriti sunt
exprimate in mg/l.
7)
Prin pesticide - clasa se intelege: insecticide, erbicide, fungicide, nematocide, acaricide, algicide, rodendicide,
slimicide organice, compusi inruditi (ca de exemplu regulatori de crestere) si metabolitii relevanti , produsii de
degradare si de reactie. Se vor monitoriza numai pesticidele presupuse prezente in sursa de apa.
8)
Concentratia se refera la fiecare compus individual. Pentru aldrin, diedrin, heptaclor si heptaclor epoxid,
concentratia maxima este de 0,030 g/l.
9)
Prin Pesticide -Total se intelege suma tuturor compusilor individuali, detectati si cuantificati in urma procedurii
de monitorizare.
10)
Pentru apa la care se refera respectarea in practica a valorii se va realiza in maximum 15 ani de la intrarea in
vigoare a prezentei legi, in primii 5 ani acceptandu-se o valoare de 25 g/l.
11)
Concentratia totala a THM trebuie sa fie cat mai mica, fara a compromite dezinfectia.
- 71 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Compusii individuali
bromdiclormetan.
specificati
sunt:
cloroform,
bromoform,
dibromoclormetan,
3)
mg/l
250
4)
Clostridium perfringens
numar/100ml
mg/l
g/l
Gust
Mangan
Oxidabilitate
PH
2500
Acceptabila
consumatorilor si nici o
modificare anormala
5
200
Acceptabila
consumatorilor si nici o
modificare anormala
3),6)
5)
50
Acceptabila
consumatorilor si nici o
modificare anormala
Nedetectabili
la 100ml
5,0
6,5; 9,5
Sodiu
mg/l
Substante tensioactive Total g/l
Sulfat3)
Sulfuri si hidrogen sulfurat
STAS 6326/90
STAS 6328/85
STAS 3001/91 ISO 9308-1
SR ISO 8245/95
STAS 3049/88
SR ISO 9297/98
STAS 3001/91
SR ISO 6461-1;2/98
STAS 6364/78
0,5
0,25
g/l
Miros
Metoda de analiza
200
200
mg/l
g/l
250
100
7)
Turbiditate
UNT
Zinc
g/l
Tritiu
Bq/l8)
8),9),10)
Doza efectiva totala de referinta
mSv/an
11)
Activitatea alfa globala
Bq/l
Activitatea beta globala
Bq/l11)
5
5000
100
0,10
0,1
1
- 72 -
STAS 7722/84
SR EN 27888/97
SR ISO 7887/97
STAS 3326/76
STAS 3086/68
SR13315/96; SR ISO 6332/96
STAS 6324/61
SR EN 1622/97
STAS 3264/81;
SR 8662-1;2/96;
SR ISO 6333/96
STAS 6324/61;
SREN 1622/97
STAS 3001/91;
EN ISO 6222/
STAS 3002/85;
SR ISO 6060/96
STAS 6325/75;
SR ISO 10523/97
-*)
STAS 7576/66;
SR ISO 7875-1;2/96
STAS 3069/87
SR 7510/97;
SR ISO 10530/97
STAS 6323/88
STAS 6327/81
SR ISO 9698/1996
-*)
SR ISO 9696/1996
SR ISO 9697/1996
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
*) Metode de analiza care nu sunt acoperite de standarde romanesti (STAS) sau preluate ca standarde romanesti
(SR ISO) si urmeaza a fi stabilite ulterior.
NOTA:
1)
Pentru apa imbuteliata unitatea de masura este numar/250 ml.
2)
Acest parametru va fi masurat numai pentru sistemele de aprovizionare care furnizeaza mai mult de 10.000 m3
pe zi.
3)
Apa nu trebuie sa fie agresiva.
4)
Acest parametru trebuie monitorizat atunci cand sursa de apa este de suprafata sau mixta, iar in situatia in
care este decelat trebuie investigata si prezenta altor microorganisme patogene, ca de exemplu: criptosporidium.
5)
Acest parametru se va analiza cand nu se poate sau nu este prevazuta determinarea COT.
6)
Pentru apa plata imbuteliata valoarea minima poate fi redusa pana la 4,5 unitati de pH. Pentru apa imbuteliata
care contine in mod natural sau este imbogatita cu bioxid de carbon, valoarea pH poate fi mai mica.
7)
Pentru apa rezultata din tratarea unei surse de suprafata nu se va depasi 1,0 UNT (unitati nefelometrice de
turbiditate) inainte de dezinfectie.
8)
Frecventa, metodele si localizarile pentru monitorizare vor fi stabilite.
9)
Doza efectiva totala de referinta acceptata pentru un adult corespunde unui consum zilnic de 2 litri apa potabila
pe o durata de un an. Monitorizarea tritiului si a radioactivitatii in apa potabila se face in cazul in care nu exista
datele necesare pentru calcularea dozei efective totale. In situatia in care este demonstrat pe baza unor
monitorizari efectuate anterior ca nivelurile de tritiu la doza efectiva totala de referinta sunt cu mult inferioare
valorii parametrice, se poate renunta la monitorizarea tritiului.
10)
Exclusiv tritiu, potasiu-40, radon si descendentii radonului. Frecventa, metodele si localizarile pentru
monitorizare vor fi stabilite.
11)
Caracterizarea calitatii apei din punct de vedere al continutului radioactiv se face prin masurarea activitatii alfa
si beta globala. In cazul in care valoarea de referinta este depasita, este necesara determinarea activitatii
specifice a radionuclizilor, conform Normelor de supraveghere, inspectie sanitara si monitorizare a calitatii apei
potabile ( L 458, 2002).
3 Concluzii
Apele de suprafata din zona judetului Iasi, se incadreaza, in general, in normele de calitate
pe care trebuie sa le indeplineasca apele de suprafata utilizate pentru potabilizare, cu
exceptia situatiilor in care pot aparea poluari accidentale;
Aceste ape pot fi folosite pentru sisteme de alimentare cu apa si canalizare in localitatile
pana la 10 000 locuitori, dupa ce vor fi supuse procesului tehnologic de tratare a apei.
Apele subterane din sursa Timisesti, pot fi, de asemenea, destinate potabilizarii, dupa o
dezinfectie corespunzatoare .
Sursele de apa proprii, pot fi folosite in scop potabil, dupa o dezinfectie eficienta si un
timp de contact al clorului cu apa de minimum 30 minute. Exceptie fac :
Apele din surse proprii, cu un continut de nitrati de peste 50 mg/l, care nu pot fi utilizate in
sistemele de alimentare cu apa .
La extinderea sistemelor de aprovizionare cu apa, se vor folosi surse de apa care
respecta normele de calitate pentru potabilizare, din reglementarile in vigoare.
Referinte bibliografice
Teodosiu,C. (2001)Tehnologia apei potabile si industriale, Ed.Matrix Rom, Bucuresti.
Rojanschi,V. (1996) Cartea operatorului din statii de tratare si epurare a apelor.
Legea 458/2002/2005, Legea calitatii apei potabile.
NTPA - 013/2002, Norme de calitate pe care trebuie sa le indeplineasca apele de suprafata utilizate pentru
potabilizare
- 73 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 74 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Sectiunea 2
SISTEME DE CANALIZARE SI
EPURARE A APELOR UZATE
- 75 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 76 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
1.1.Generaliti
La nceputul secolului XXI , aproximativ 45% din populaia Romniei reprezint mediul rural.
Exist unele sate(comune) mai importante n care alimentarea cu ap se face n sistem
centralizat, in timp ce evacuarea apelor uzate ntr-o reea de canalizare este mai puin
dezvoltat.
n prezent, epurarea apelor uzate din Romnia se face la sursele mari de poluare (orae
i mari industrii) unde au fost construite reelele de canalizare care conduc apele uzate la o
staie de epurare i apoi n receptor. n acest caz reelele de canalizare sunt construite de-a
lungul strzilor unde exist muli locuitori pe kilometrul de canal, iar costurile de investiie i
exploatare pot fi recuperate de la locuitori i sunt suportabile.
n schimb n mediul rural, nu se justific ntotdeauna executarea de colectoare, deoarece
exist grupuri de gospodrii izolate, motiv pentru care se aleg alte soluii de epurare i
evacuare final a apelor uzate, care s fie economice i uor de executat. n comunitile
mici rurale receptorii reprezint mici cursuri de ap i cteodat cu regim hidrologic
nepermanent; n acest caz eficiena staiei de epurare trebuie s fie superioar celei de tip
urban, iar efluentul trebuie s fie dezinfectat. Pentru asigurarea n bune condiii a proceselor
de epurare este necesar un personal de exploatare permanent, iar instalaiile s fie
automatizate; deoarece staia este amplasat n apropierea zonelor locuite, instalaiile
trebuie s realizeze un grad avansat de stabilizare a nmolului. rspund.
La evaluarea debitelor i calitii apelor uzate, n localtiile mici i mijlocii trebuie s se
in cont de micile industrii cu caracter agro-alimentar (lptrii, mici abatoare, fabrici de
conserve de fructe etc.) precum i de apele uzate din sectorul agrozootehnic al gospodriilor
(urina animalelor, fraciunea lichid scurs de la platformele de blegar, apele uzate din
grajduri etc.)
n Romnia exist un important numr de case individuale care au sisteme de colectare a
apelor uzate (bazine etane vidanjabile) cuplate cu sisteme de evacuare periodic.
Conform Normativului elaborat de Universitatea Tehnic de Construcii Bucureti din
punct de vedere al debitului de ape uzate, se deosebesc urmtoarele categorii:
- debite mici (5 < q < 50l/s);
- debite foarte mici (q < 5l/s).
Cazul nostru se ncadreaz la debite mici i foarte mici. Din punctul de vedere al
evacurii apelor uzate n receptorii naturali de suprafa (ruri, lacuri) se poate aplica
normativul NTPA 001/2002 care prezint valorile limit admisibile ale principalilor indicatori
fizico-chimici.
Un alt caz de evacuare a apelor uzate de la aceste comuniti mici, este acela al
evacurii n apele subterane, caz n care trebuie respectate valorile limit admisibile
- 77 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
prevzute pentru apa potabil (Legea nr. 451/2002), deoarece se presupune c apele
subterane pot fi n orice moment solicitate ca surs de ap potabil.
Rezult c apele uzate rezultate n mediul rural de la comuniti mici i mijlocii, nu pot fi
evacuate fr a fi epurate innd cont de reglementrile menionate mai sus.
n ansamblul de msuri de protecia mediului care urmeaz a se prevedea n acest caz,
nu trebuie neglijat problema nmolurilor care rezult n urma proceselor de epurare.
Nmolurile rezultate n urma epurrii apelor uzate, la debite mici i mijlocii, poate fi
studiat din punct de vedere al pretabilitii nmolurilor la folosirea n agricultur i la
condiiile pedoclimatice din zona respectiv.
- 78 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 79 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 80 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
BIBLIOGRAFIE
. AQUAPROIECT S.A. 2007 Studiu privind epurarea apelor uzate prin mijloace ecologice inovative pentru
localiti sub 2000 locuitori din zona de frontier Ministerul Mediului i Dezvoltrii Durabile - Bucureti
- 81 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Cuvinte cheie: retea de canalizare in mediul rural, retea sub presiune, retea sub vacuum, pompare.
Introducere
Sarcinile asumate de Romania, in perioada de preaderare, in ce priveste ridicarea
standardului de viata al populatiei din mediul rural are si o importanta dimensiune legata de
realizarea lucrarilor edilitare in speta a lucrarilor pentru asigurarea cu apa potabila si
evacuarii apelor uzate epurate. Concret pana in 1918 ( deci in 10 ani) trebuie sa aiba apa
potabila toate localitatile peste 50 locuitori iar apa uzata colectata de la aglomerarile peste
2000 LE (populatie echivalenta) trebuie sa fie epurata mecanic si biologic. Pentru localitatile
care vor avea apa dar nu au 2000 loc. ce se intampla? Distinctia intre cele doua cazuri apare
numai in ce priveste fondurile. Pentru localitatile peste 2000 LE fondurile vor putea fi
asigurate din UE ( nerambursabile) pe cand pentru celelalte localitati vor fi folosite fonduri
din bugetul local/ general. In concluzie se poate spune ca anul 2018 este anul in care marea
majoritate a localitatilor vor avea apa potabila la robinet si canalizarea si epurarea adecvata
a apelor uzate. Pentru aceasta vor trebui insa realizate cateva mii de sisteme de alimentare
cu apa si de canalizare.
Cum pentru alimentarea cu apa problemele pot fi solutionate dupa tehnica folosita in
general ( cu anumite particularitati) pentru canalizare lucrurile sunt mai complicate.
- 82 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
sunt racordati si in aceste conditii rezulta debitul de calcul. In realitate , din motive economice
de obicei, racordarea se face lent si neuniform. Si atunci cum va functiona reteaua?
In tehnica incetatenita la noi in tara se aplica un singur sistem de retea; canalizare
gravitationala cu apa curgand cu nivel liber. Acest sistem constructiv, in conditiile mentionate
mai sus, va functiona fara sa asigure viteza de autocuratire in majoritatea timpului si pe cea
mai mare a lungimii colectoarelor /7/. Desi posibila spalarea artificiala este greu de aplicat
(costuri mari).
Normele tehnice actuale ( SR EN 752, SR 1846-1)impun trei elemente cheie in
dimensionarea retelei de canalizare : diametrul minim al canalizarii-250mm, viteza minima de
curgere 0,7 m/s si panta minima I= 1000/DN,in %0. Daca se tine seama de debitul mic si de
faptul ca se poate recurge la o spalare hidraulica eficienta s-ar putea admite si diametrul 200
mm si in acest caz panta minima ar trebui sa fie 5%0. De multe ori aceasta panta nu poate fi
asigurata din cauza terenului.
- 83 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
comprimat. Cum dimensionarea hidraulica are unele aspecte particulare se va reveni asupra
acestui element.
dupa STAS 1479/ 87, care se refera la calculul debitelor din reteaua interioara de
canalizare; se poate accepta ca este posibil un model in care colectorul seamana cu
o coloana de scurgere la un bloc asezat orizontal; debitul este functie de suma
- 84 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Studiu de caz.
Rezolvarea simplificata a unui caz poate da un ordin de marime a dimensiunilor
colectorului, marimii pompei, consumului de energie si costurilor.
a- Datele de baza pentru studiul de caz sunt: localitatea este amplasata intr-o zona
de ses cu panta longitudinala a drumului de 5%0; localitatea are 2000 loc.;
distributia locuitorilor este uniforma pe strada cu lungimea de 6000m; se
presupune ca frontul la strada este de 20m/casa; o familie locuieste intr- o casa
individuala si are 3 membrii; consumul specific de apa este 100 l/om.zi; coeficientii
de variatie zilnica si orara sunt 1,3 respectiv 5,0; toata localitatea este alimentata cu
apa si toate casele vor fi racordate la canalizare; debitul de apa uzata restituita la
canalizare 100 l/om.zi.
b- Cu aceste date rezulta: localitatea are 668 familii (case).
c- Cu variatia considerata se calculeaza debitul de calcul si debitul minim pe calector
in sectiunile de colector aflate la 20,1500,3000,4500 si 6000m. Valorile sunt date in
tabelul 1.
c-1- dupa SR 1343-1/05 rezulta un debit cu crestere liniara cu valoare maxima in
sectiunea finala, vezi tab 1.
c-2-Dupa STAS 1479 se evalueaza numarul de echivalenti pentru o familie ( dotare tip :
1 chiuveta= 0,33 l/s (1E), 1 baie= 0,66l/s (2E), un spalator=0,33l/s (1E), 1 WC=2l/s (6 E)
sau 3,33l/s (10E) in total. Cu valorile date in standard se poate calcula numarul de
echivalenti si debitul de dimensionare pentru aceleasi sectiuni. Valorile sunt date in
tabelul 1. Valorile nu mai cresc liniar si sunt mai mari decat cele calculate cu SR 1343.
c-3- Pentru estimarea debitului prin metode probabilistice se adopta urmatoarea metoda:
se considera ca fiecare consummator va utiliza volumul de apa afectat (100l/om.zi)
folosind cel putin un robinet; cum debitul tip al unui robimet este 0,13 l/s rezulta un timp
maxim de folosire a apei in 100: 0,13l/s = 769 sec. sau cca 13 minute din cele 1440
minute durata unei zile. Problema care se pune este : cati din locuitori folosesc apa in
acelasi timp, considerand ca apa este folosita toata intr-o singura transa. Daca se
foloseste metoda propusa de ing C Felix /1/ rezulta ca numarul cel mai probabil de familii
care functioneaza simultan este 6 ( unde T=1440 min/an, t=13min., n=667 familii).
Rezulta ca debitul maxim pe colector va fi 6x 0,13 = 0,78 l/s; debitul pare deosebit de
mic; pentru siguranta dimensionarii cele 6 familii vor fi considerate la capatul amonte al
colectorului.
c-4- estimarea debitului functie de numarul maxim de pompe in functiune simultana; se
foloseste tot metoda data in /1/; numarul maxim de pompa in functiune este calculabil cu
relatia
- 85 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
t( n+1)
t(n-1)
----------- > a > -------- -1
T
T
(1)
Sectiunea
SR 1343 mc/zi
l/s
STAS 1479 E
l/s
Probabilitate de
funct. locuinte,
l/s
Prob de funct.
pompe;
l/s
20m
0,3
0,003
10
0,43
0,16
1500m
325
3,76
1670
7,14
0,16
3000m
650
7,5
3330
11,1
0,16
4500m
975
11.3
5000
14,33
0,16
6000m
1300
15,05
6660
17,10
0,16
2,4
2,4
2,4
2,4
2,4
Se poate constata ca: debitele date de SR 1343 sunt apropiate de cele obtuinute cu
STAS 1479 cu mentiunea ca debitele dupa STAS 1479 sunt mai favorabile dimensionarii in
portiunea initiala a colectorului; valoarea debitelor obtinute folosind ideea de functionare
simultana a familiilor sau pompelor conduce este foarte mica( valori de debite usor de
depasit in practica). Se poate lua in calculul de dimensionare a colectorului varianta cu
debite calculate cu STAS 1479.
d- Dimensionarea colectorului se face pentru tuburi din PVC, cu panta hidraulica
medie egala cu panta medie a terenului (5%0) si pe tronsoane de 1500m; viteza
apei trebuie sa fie min. 0,7 m/s; pentru comparatie este dat si diametrul tubului in
varianta canalizare gravitationala cu nivel liber. Valoarea diametrului colectorului
este data in tabelul 2
Tabel 2: dimensiunea diametrului colectorului
Sectiunea
20m
Canalizare.
250mm
gravitationala
Canalizare cu 75mm
pompare
1500m
250mm
3000m
250mm
4500m
250mm
6000m
250mm
125mm
160mm
160mm
160mm
- 86 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
colector
camine
nr
Pu/buc Inv.
nr
DNmm L/m Pu/m Inv.
6
6
10
10
lei
lei
Gravit.
250
6000 352
2,112 120 1500
0,18 Pompare 125
1500 246
0,369 12 1500
0,018 167
*
160
4500 274
1,223
Varianta
pompe
Pu/buc Inv.
106
lei
30000 4,993
Total
106
lei
2,638
6,61
Concluzii
a- In urmatorii 10 ani vor trebui realizate cateva mii de sisteme de canalizare pentru
localitatile din mediu rural.
b- Retelele de canalizare realizate in stil clasic-curgere gravitationala cu nivel liber- vor
avea mari probleme de exploatare din cauza debitului redus si a imposibilitatii realizarii
vitezei de autocuratire pe cea mai mare parte a lungimii acesteia.
c- In lume au fost realizate solutii alternative: canalizare functionand sub vacuum,
canalizare functionand sub presiune. Reteaua de canalizare sub presiune are multe
avantaje, cum ar fi: adancime mica de pozare, dimensiunui mici pentru colector, depasirea
usoara a obstacolelor de pe traseu etc. Reteaua are nevoie de o buna dimensionare si o
exploatare specializata. Intr-o prima etapa se poate accepta ca dimensionarea colectorului
se poate face la debitul calculate dupa STAS 1479.
d- Din studiul de caz rezulta un cost mai mare de investitie dar un consum relativ mic de
energie. Este esentiala gasirea unor sisteme de pompare de dimensiuni mici si cost cat mai
redus; costul statiilor de pompare a fost facut ca pentru lucrari mari.
e- Determinarea debitelor de calcul se poate face in mai multe metode; din calcul se
poate constata diferente relativ mari ale valorilor. Aplicarea calculului probabilistic nu
conduce inca la o solutie economicoasa de determinare a debitului maxim in retea si a
ritmului de pompare.
- 87 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Bibliografie
1. C St Felix; Consideratii asupra dimensionarii conductelor de distributie a apei; Bul. Soc. Politehnica 5-8/1845
2. P Trofin ; Consideratiuni asupra dimensionarii conductelor de distributie a apei; Bul. Soc Politehnica /1945
3. J Doinel ; Assainissement; Lalternative des reseaux ramifies sous pression; Leau, Lindustrie, Les Nuisances
nr 306/ 2007
4. xxx
Sisteme de canalizare sub presiune: Prospect/ ROMET- Buzau, 2007
5. D Cvaci, F W Gunthlet; Analiza a 20 sisteme speciale de canalizare in mediul rural (canalizare sub presiune si
prin vacuum); ARA conference 2006
6. F Gergely, Peter Alex. ; Sistem de canalizare prin vacuum; Conference of Yung Professionels- Bucharest
2005.
7. Al Manescu-Derspre necesitatea dezvoltarii de solutii noipentru sisteme de canalizare pentru localitatile din
mediul rural; ROMAQUA 1/2008
- 88 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Date generale
Problema alegerii solutiei optime de epurare a apelor uzate si tratare a namolurilor rezultate
de din statiile de epurare, pentru localitati dispersate pe arii extinse, este o problema
complexa, care implica o analiza detaliata pentru fiecare caz in parte.
O astfel de analiza s-a realizat pentru alegerea solutiei de epurare, respectiv deshidratare
a namolurilor rezultate din statiile de epurare, pentru 6 localitati din judetul Giurgiu: Giurgiu,
Bolintin Vale, Ogrezeni, Gradinari, Buturugeni si Mihailesti.
A fost necesara efectuarea unei analize detaliate pentru selectarea celor mai favorabile
locatii pentru statiile de epurare si selectarea modului de realizare a deshidratarii namolului
rezultat in urma procesului de epurare.
Referitor la epurarea apei uzare s-au analizat optiuni legate de amplasarea statiilor de
epurare, astfel:
SE Giurgiu - 82.400 l.e.; SE Bolintin Vale - 11.200 l.e.; SE Ogrezeni - 4.500 l.e.;
SE Gradinari - 3.500 l.e.; SE Buturugeni - 4.200 l.e.; SE Mihailesti - 6.600 l.e.
sau
- 89 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Tinand cont de elementele expuse anterior s-au identificat 7 optiuni diferite ce vor fi
analizate in cele ce urmeaza. Optiunile identificate sunt prezentate in tabelul urmator.
Tabel 1. Descrierea optiunilor identificate privind epurarea apelor uzate si deshidratarea namolurilor
Nr.
Parametru
crt
Epurarea
apelor
uzate
Deshidrata
re namol
Optiunea 1
Optiunea
5
Optiunea 2
Optiunea 3
Optiunea 4
SE Giurgiu
independenta
82.400 l.e.
SE Giurgiu
independenta
82.400 l.e.
SE Giurgiu
independenta
82.400 l.e.
SE Giurgiu
independenta
82.400 l.e.
SE Giurgiu
SE Giurgiu
independenta independenta
82.400 l.e.
82.400 l.e.
SE Bolintin Vale
independenta
11.200 l.e.
SE Bolintin
Vale
independenta
11.200 l.e.
SE Ogrezeni
independenta
4.500 l.e.
SE Gradinari
independenta
3.500 l.e.
SE Buturugeni
independenta
4.200 l.e.
SE Mihailesti
independenta
6.600 l.e.
Deshidratare
locala in SE
Giurgiu
SE Bolintin
Vale
independenta
11.200 l.e.
SE Ogrezeni
independenta
4.500 l.e.
SE Gradinari
independenta
3.500 l.e.
SE Buturugeni
independenta
4.200 l.e.
SE Mihailesti
independenta
6.600 l.e.
Deshidratare
locala in SE
Giurgiu
Centralizat in
Buturugeni,
pentru Bolintin
Vale,
Ogrezeni,
Gradinari,
Buturugeni si
Mihailesti
30.000 l.e.
Centralizat
in
Buturugeni,
pentru
Bolintin
Vale,
Ogrezeni,
Gradinari,
Buturugeni
si Mihailesti
30.000 l.e.
Centralizat in
Mihailesti
pentru
Bolintin Vale,
Ogrezeni,
Gradinari,
Buturugeni si
Mihailesti
30.000 l.e.
Deshidratar
e locala in
SE Giurgiu
Deshidratare
locala in SE
Bolintin Vale
Unitate mobila
- 3 zile in
Bolintin Vale
Deshidratare
locala in SE
Ogrezeni
Unitate mobila
- 1 zi in
Ogrezeni
Centralizat in
Giurgiu,
pentru
Giurgiu,
Bolintin Vale,
Ogrezeni,
Gradinari,
Buturugeni si
Mihailesti
Transportul
namolului
stabilizat de la
SE Buturugeni
la SE Giurgiu
Centralizat in
SE Giurgiu,
pentru
Giurgiu,
Bolintin Vale,
Ogrezeni,
Gradinari,
Buturugeni si
Mihailesti
Transportul
namolului de
la SE
Mihailesti la
SE Giurgiu
Deshidratare
locala in SE
Gradinari
Unitate mobila
- 1 zi in
Gradinari
Deshidratare
locala in SE
Buturugeni
Unitate mobila
- 1 zi in
Bututurgeni
Deshidratare
locala in SE
Mihailesti
Unitate mobila
- 1 zi in
Mihailesti
SE Ogrezeni
independenta 4.500
l.e.
SE Gradinari
independenta 3.500
l.e.
SE Buturugeni
independenta 4.200
l.e.
SE Mihailesti
independenta 6.600
l.e.
Deshidratare
centralizata in SE
Giurgiu, pentru
Giurgiu, Bolintin
Vale, Ogrezeni,
Gradinari,
Buturugeni si
Mihailesti
Transportul
namolului stabilizat
de la Bolintin Vale
la Giurgiu
Transportul
namolului stabilizat
de la Ogrezeni la
Giurgiu
Transportul
namolului stabilizat
de la Gradinari la
Giurgiu
Transportul
namolului stabilizat
de la Buturugeni la
Giurgiu
Transportul
namolului stabilizat
de la Mihailesti la
Giurgiu
- 90 -
Deshidratar
e locala in
SE
Buturugeni
Optiunea 6
Optiunea 7
Giurgiu
independent
SEAU 82.400 p.e.
Centralizat in
Mihailesti
pentru
Bolintin Vale,
Ogrezeni,
Gradinari,
Buturugeni si
Mihailesti
30.000 l.e.
Deshidratare
locala in SE
Giurgiu
Deshidratare
locala in SE
Mihailesti
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Fiecare optiune a fost evaluata din mai multe puncte de vedere; astfel s-a avut in vedere:
Costul de intretinere estimat, considerat ca procent fix de 1.5% din costul investitiei;
- 91 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
SE Giurgiu 82.400 l.e.; SE Bolintin Vale 11.200 l.e.; SE Ogrezeni 4.500 l.e.;
SE Gradinari 3.500 l.e.; SE Buturugeni 4.200 l.e.; SE Mihailesti 6.600 l.e.
Transportul namolului stabilizat din fiecare localitate dotata cu statie de epurare (total
52 m3/zi) la SE Giurgiu, unde este deshidratata intreaga cantitate de namol
(480+52=532 m3/zi).
- 92 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Costurile:
Vehicularea unor cantitati mari de namol intr-o singura locatie implica dificultati de
natura tehnica si costuri mari de pentru depunerea namolului procesat.
Descrierea optiunii 2
In optiunea 2 au fost analizate urmatoarele ipoteze:
SE Giurgiu 82.400 l.e.; SE Bolintin Vale 11.200 l.e.; SE Ogrezeni 4.500 l.e.;
SE Gradinari 3.500 l.e.; SE Buturugeni 4.200 l.e.; SE Mihailesti 6.600 l.e.
- 93 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Descrierea optiunii 3
In optiunea 3 au fost analizate urmatoarele ipoteze:
SE Giurgiu 82.400 l.e.; SE Bolintin Vale 11.200 l.e.; SE Ogrezeni 4.500 l.e.;
SE Gradinari 3.500 l.e.; SE Buturugeni 4.200 l.e.; SE Mihailesti 6.600 l.e.
- 94 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Costuri:
- 95 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Descrierea optiunii 4
In optiunea 4 au fost analizate urmatoarele ipoteze:
Aceasta solutie implica transportul apei uzate colectate dupa cum urmeaza:
Figura 4. Plan descriptiv al optiunii 4 centralizarea epurarii in Giurgiu si Buturugeni si centralizarea deshidratarii
namolului in SE Giurgiu
- 96 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Costuri:
Vehicularea unor cantitati mari de namol intr-o singura locatie implica dificultati de
natura tehnica si costuri mari de pentru depunerea namolului procesat.
Descrierea optiunii 5
In optiunea 5 au fost analizate urmatoarele ipoteze:
Aceasta solutie implica transportul apei uzate colectate dupa cum urmeaza:
- 97 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Costuri:
Descrierea optiunii 6
In optiunea 6 au fost analizate urmatoarele ipoteze:
Aceasta solutie implica transportul apei uzate colectate, gravitational de la Bolintin Vale la
Mihailesti (doar 1 statie de pompare la traversarea raului Arges).
Figura 6. Plan descriptiv al optiunii 6 centralizarea epurarii in Giurgiu si Mihailesti si centralizarea deshidratarii
namolului in SE Giurgiu
- 98 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Costuri:
Vehicularea unor cantitati mari de namol intr-o singura locatie implica dificultati de
natura tehnica si costuri mari de pentru depunerea namolului procesat.
Descrierea optiunii 7
In optiunea 7 au fost analizate urmatoarele ipoteze:
- 99 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Aceasta solutie implica transportul apei uzate colectate, gravitational de la Bolintin Vale la
Mihailesti (doar 1 statie de pompare la traversarea raului Arges).
Principalele avantaje ale acestei optiuni sunt:
Costuri:
Parametru
Costul de investitie
(Euro)
Costul de operare
(Euro/an)
Costul apei
3
epurate (Euro/m )
AVANTAJE
Optiunea 1
DEZAVANTAJE
Optiunea 3
Optiunea 4
Optiunea 5
Optiunea 6
Optiunea 7
16,578,000
15,289,000
15,444,000
18,968,000
17,654,000
19,106,000
17,792,000
1,513,174
1,224,286
1,238,855
1,496,276
1,294,455
1,461,477
1,248,925
0.256
Colectoare
scurte fara
statii de
pompare
Deshidratare
centralizata in
SE Giurgiu,
pentru toate
localitatile
Fara epurare
centralizata
5
Optiunea 2
0.207
Colectoare
scurte fara
statii de
pompare
Evacuarea
namolului in
zona de
producere
0.210
Colectoare
scurte fara
statii de
pompare
Evacuarea
namolului in
zona de
producere
0.254
Epurare
centralizata
doar in 2 SE
Deshidratare
locala si
evacuarea
namolului in 2
locatii
Volume mici
Doar o unitate Fara problema Fara
ale bazinelor
de
namolului in
transportul
de stabilizare a deshidratare a Buturugeni
namolului pe
namolului
namolului
drumurile
pentru 5 locatii
publice
Cost scazut al
investitiei
Cost de
operare scazut
Personal
Volume mari Transport
Colectoare
calificat
ale bazinelor dificil al
lungi de
necesar pentru de stabilizare namolului
canalizare de
operarea
a namolului
folosind
la Bolintin
unitatilor de
autocamioane Vale,
deshidratare
speciale
Ogrezeni,
Gradinari,
Mihailesti la
Buturugeni
- 100 -
Deshidratare
centralizata in
SE Giurgiu
0.219
Epurare
centralizata
doar in 2 SE
0.248
Epurare
centralizata
doar in 2 SE
0.212
Epurare
centralizata
doar in 2 SE
Deshidratare
centralizata in
SE Giurgiu
Deshidratare
locala si
evacuarea
namolului in 2
locatii
Fara problema Fara
namolului in
transportul
Mihailesti
namolului pe
drumurile
publice
Transport
dificil al
namolului
folosind
autocamioane
speciale
Colectoare
lungi de
canalizare de
la Bolintin
Vale,
Ogrezeni,
Gradinari,
Buturugeni la
Mihailesti
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Nr.
crt
Parametru
Optiunea 1
Optiunea 2
Optiunea 3
Optiunea 4
Optiunea 5
Optiunea 6
Optiunea 7
Consum
ridicat de
energie
datorita
statiilor de
pompare din
Bolintin Vale si
de pe sectorul
Mihailesti Buturugeni
Cost mare al
investitiei
Cost de
operare mare
Cantitati mari
de namol
deshidratat vor
fi evacuate in
zona Giurgiu
Consum ridicat
de energie
datorita statiei
de pompare
Bolintin Vale
Cost mare al
investitiei
Cost de
operare mare
Cost mare al
investitiei
Cost de
operare mare
Cantitati mari
de namol
deshidratat vor
fi evacuate in
zona Giurgiu
Cost mare al
investitiei
Cantitati mari
de namol
deshidratat vor
fi evacuate in
zona Giurgiu
Cost mare al
investitiei
Cost de
operare mare
Cost de
operare mare
Cost mare al
investitiei
Cost de
operare mare
Optiunile bazate pe transportul namolului stabilizat prin pompare sau prin mijloace
auto pe distante mai mari de 2.0 2.5 km conduc la costuri de investitie si operare
prohibitive (vezi optiunea 5 si optiunea 6);
Concluzii
Alegerea solutiei de epurare a apelor uzate si tratare a namolurilor rezultate din statiile de
epurare este o problema complexa, care depinde de multi parametri variabili. Pentru fiecare
caz in parte este necesara o analiza detaliata, in care trebuie sa se tina cont de toate
elementele care influenteaza procesele de epurare si de operare, atat la nivel de localitate,
cat si la nivelul intregului ansamblu format de localitatile din zona analizata.
Analiza tehnico-economica a solutiilor propuse este necesar sa fie completata de
realizarea unei analize a impactului asupra sanatatii umane, efectele asupra dezvoltarii
sociale a zonei analizate, efectele asupra resurselor si impactului asupra mediului.
Pentru localitati mici, dispersate pe arii largi, adoptarea solutiei pentru epurarea apelor
uzate si deshidratarea namolurilor trebuie sa ia in consideratie:
- 101 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Se impune sa fie remarcat ca fiecare locatie sau ansamblu de mici localitati prezinta
particularitati proprii si nu poate exista o solutie generala si unica.
Solutia optima va rezulta din analize tehnico-economice. In aceasta etapa (2007-2010)
se contureaza solutia:
Bibliografie
CES Consulting, GFA Consulting, U.T.C.B. Asistenta Tehnica pentru Pregatirea Proiectelor in Sectorul de Apa
Potabila si Apa Uzata din Romania EuropeAid/119083/D/SV/RO2003/RO/16/P/PA 013-04 - STUDIU DE
FEZABILITATE JUDETUL GIURGIU August 2007
- 102 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Gabriel Racoviteanu*
* Universitatea Tehnica de Constructii Bucuresti Facultatea de Hidrotehnica, Catedra de Inginerie Sanitara si
Protectia Apelor Bd. Lacul Tei nr. 124, sector 2, Bucuresti, E-mail: rgabriel@utcb.ro
ABSTRACT
Water supply and sewerage systems for small and isolated communities is based on special
technological elements related to the way in which this types of problems are solved in larger
communities.
The treatment technologies available for small and very small communities are often very
different than the usual technologies for large communities. A small scale replica of the
technological objects from a classical wastewater treatment plant determines low efficiency
of the process and higher investment and operating costs.
The paper presents the experimental trials on a compact aerobic treatment system
belonging to Valrom Industrie but also other type of systems available on the market.
- 103 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 104 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Tabelul 1. Caracteristici ale efluentului unui sistem de epurare anaerob pentru apa uzata de tip menajer.
Parametru
Universitatea
din Wisconsin
(1978)
Harkin si
altii
(1979)
Ronayne
si al.
(1982)
Ayres
Associates
(1993)
Ayres
Associates
(1996)
7
Wisconsin
150
138
327
49
45
13
4.6
33
Wisconsin
140 - 215
132
445
87
82
21.8
6.5
8
Oregon
56
217
146
57.1
6.4
8
Florida
36
141
161
39
11
36
5.1 8.2
1
Florida
3
179
59
66
17
37
7
Tabelul 2. Caracteristici ale efluentului sistemelor de epurare anaerobe - apa uzata menajera, comunitati mici
(valori medii).
Parametru
CBO5 (mg/l)
CCO (mg/l)
Materii in suspensie (mg/l)
Azot total (mg N/l)
Fosfor total (m/l)
Grasimi (mg/l)
Coliformi fecali (log unit./l)
pH
Debit (l/pers/zi)
Westboro,
WIa
168
338
85
63.4
8.1
7.3
6.9 7.4
136.2
Bend, ORb
Glide,
Manila, CAd
c
OR
157
118
189
276
228
284
36
52
75
41
50
65
16
22
6.4 7.2
6.4 7.2
6.5 7.8
151.4 227.1
181.7 151.4 215.7
College
Sta. TXe
266
29.5
8.2
6.0
7.4
-
Parametru
pH
Restaurant A
Restaurant B
Restaurant C
582
245
880
1196
622
1667
187
65
372
82
64
71
24
14
23
101
40
144
8 22
8 22
13 23
5.6 6.4
6.6 7.0
5.8 6.3
Restaurant D
Restaurant E
Restaurant F
Motel
Restaurant rural A
377
693
261
171
197
772
1321
586
381
416
247
125
66
66
56
30
78
73
34
36
15
28
19
20
13
101
65
47
45
24
16 21
4 26
7 25
20 28
6 20
5.7 6.8
5.5 6.9
5.8 7.0
6.5 7.1
6.5 6.8
Restaurant rural B
Restaurant rural C
Bar / gratar
333
101
179
620
227
449
121
44
79
63
36
61
17
10
7
46
33
49
13 26
10 23
8 - 22
6.2 6.8
6.2 7.4
6.0 7.0
Nota: Valorile reprezinta medii a 2 9 probe instantanee (depinzand de parametru) luate in perioada Martie
Septembrie 1983 (Siegrist si al., 1985).
- 105 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 106 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Initial fosa se umple cu apa curata. In momentul conectarii la conducta de apa uzata va
intra in functiune aeratorul care va ramane pornit pe toata perioada functionarii.
Pentru a fi biologic stabila este necesara o perioada de timp de 4 pana la 12 saptamani
de la punerea in functiune pentru dezvoltarea biomasei.
O unitate tipica de epurare aeroba din trei compartimente consta in:
un compartiment de aerare;
Epurarea aeroba asigura atat oxidarea materiilor organice cat si a amoniului si conduce
la reducerea concentratiei de organisme patogene. O unitate de epurare aeroba care are
incorporata si o treapta de dezinfectie ofera o eficienta de epurare echivalenta cu o statie de
epurare oraseneasca.
- 107 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Sistemele septice de epurare aerobe sunt proiectate dupa principiile generale ale statiilor
de epurare orasenesti. Calitatea efluentului unitatilor de epurare aeroba este puternic
influentata de calitatea apei uzate, temperatura, conditii de exploatare si agentii chimici
utilizati in gospodarie. Pentru o unitate care lucreaza parametrii proiectati, influentul fiind apa
menajera de la locuinte, caracteristicile tipice ale efluentului sunt:
CBO5 = 25 mg/l;
MTS = 30 mg/l;
Azotati NO3;
Azotiti NO2;
Amoniu NH4;
- 108 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 109 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 110 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
functionare sunt sub valoarea maxim admisa la deversarea in emisar (incluzand si soluri
permeabile) conform NTPA 011 (35 mg/l).
Din punct de vedere al retinerii MTS se poate afirma ca sistemul cu aerare corespunde
cerintelor de descarcare impuse de NTPA 011.
10000
Influent
Efluent
MTS (mg/l)
1000
100
Valoare NTPA 011 - 35 mg/l
10
1
1
10
Proba
Figura 5. Evolutia concentratiei MTS in apa uzata influenta si in efluent.
- 111 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
1000
Influent
Efluent
100
10
1
10
Proba
Figura 6. Evolutia concentratiei CBO5 in apa uzata influenta si in efluent.
- 112 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Efluent
1000
100
Valoare NTPA 011 - 125 mg/l
10
1
10
Proba
Figura 7. Evolutia incarcarii organice in apa uzata influenta si in efluent.
Concluzii
Experimentele pentru evaluarea eficientei sistemului de epurare Valrom au pus in evidenta
cele ce urmeaza:
valorile concentratiilor MTS in efluent sunt sub valoarea maxim admisa la deversarea
in emisar (incluzand si soluri permeabile) conform NTPA 011 (35 mg/l).;
din punct de vedere al incarcarii organice exprimata prin consumul chimic de oxigen
determinat prin metoda cu dicromat de potasiu se constata ca la o concentratie
medie a CBO5 in influent de 450 mg/l, concentratia medie de CBO5 din efluent este
de 43 mg/l (valoare mai mica decat cea dintr-un curs natural de apa);
din punct de vedere al incarcarii organice exprimata prin CBO5 se poate afirma ca
sistemul de epurare Valrom corespunde cerintelor de descarcare impuse de NTPA
011 in cazul folosirii acesteia in conditii normale de functionare (fara incarcari
suplimentare);
valoarea medie a incarcarii organice (CCO-Cr) din influent este de 983 mg O2/l, iar
valoarea medie a incarcarii organice din efluent este de 107 mg O2/l; rezultatele
analizelor pun in evidenta faptul ca din punct de vedere al retinerii materiilor organice
fosa F02 cu aerare corespunde in totalitate cerintelor de descarcare impuse de NTPA
- 113 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Bibliografie
Ayres Associates Onsite Sewage Disposal Systems Research in Florida: Performance Monitoring and
Groundwater Quality Impacts of OSDSs in Subdivision Developments, Report to the Departament of Health
and Rehabilitative Service, Tallahassee, Fl. Ayres Associates, Madison.
Bicki, T.J., R.B. Brown, M.E. Collins, R.S. Mansell, D. J. Rothwell Impact of On Site Sewage Disposal on
Surface and Groundwater Quality. Report to florida Department of Health and Rehabilitative Services,
Institute of Food and Agricultural Science, University of Florida, 1984.
Baumann, E.R., and H.E. Babbit.. An Investigation of the Performance of Six Small Septic Tanks. University of
Illinois Engineering Experiment Station. Bulletin Series No. 409. Vol. 50, No. 47. University of Illinois, Urbana,
IL. 1953.
Boller, M., A. Schweger, J. Eugster, and V. Mettier. Dynamic behavior of intermittent sand filters. Water
Science and Technology 28(10):98-107. 1994.
Boyer, J.A., and C.A. Rock. Performance of Septic Tanks. Proceedings, ed. R.W. Seabloom, Seventh Northwest
On-Site Wastewater Treatment Short Course and Equipment Exhibition, University of Washington,
Seattle1992.
Cantor, L.W. R.C. Knox Septic Tank System Effects on Groundwater Quality Lewis Publishers listserve, Inc.,
Chelsea, 1985.
Converse, James C.. - Aeration Treatment of Onsite Domestic Wastewater Aerobic Units and Packed Bed
Filters, University of Wisconsin-Madison. 1997, 1999, 2000, 2001.
Crites, R., and G. Tchobanoglous - Small and Decentralized Wastewater Management Systems, McGraw-Hill,
San Francisco, CA. 1998.
Guvernul Romaniei HG 188/2002 Hotarare pentru aprobarea unor norme privind conditiile de descarcare in
mediul acvatic a apelor uzate.
The water quality Program Committee, Virginia Tech Alternative onsite wastewater treatment and disposal
options 1996.
U.S. EPA - Onsite Wastewater Treatment and Disposal System Design Manual, EPA 625/1 80 - 012, U.S.
EPA, Washington, DC.
U.S. EPA - Guide to Septage Treatment and Disposal, EPA 625R 94/002, U.S. EPA, Washington, DC.
U.T.C.B. Lucrari de cercetare-dezvoltare si proiectare tehnologica pentru sistemele de epurare a apelor uzate.
Contract 44/2005.
Victor Ianuli, Gh. Rusu Statii de epurare a apelor uzate orasenesti exemple de calcul partea I, Institutul de
Constructii Bucuresti, 1983.
Weymann, D.F., A. Amoozegar, and M.T. Hoover. Performance of an on-site wastewater disposal system in a
slowly permeable soil - On-Site Wastewater Treatment: Proceedings of the Eighth National Syposium on
Individual and Small Community Sewage Systems, ed. D.M. Sievers, pp. 134-145. American Society of
Agricultural Engineers, St. Joseph, MI. 1998.
- 114 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Abstract:
Tehnologia RESETILOVS un CO, reconstruiete prin proiectele staiilor de epurare,
condiiile naturale pentru dezvoltarea organismelor de la nivelele lanului de nutriie detritic,
care va avea urmtoarele urmri: ndeprtarea poluanilor ca urmare a completei mineralizri
a acestora pn la transformarea lor n compui anorganici; completa dezinfectare
biologic; lipsa surplusului de nmol.
Cuvinte cheie: epurarea apelor uzate, epurare biologica, lant trofic detritic
- 115 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 116 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
- 117 -
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
3. Tehnologia
Statiile de epurare RESETILOVs sunt statii modulare, executate din inox.
Apele uzate ntr n staia de pompare, din canalizare, gravitational. De la staia de pompare,
apele uzate intr printr-o conduct de presiune, n blocul de epurare mecanic, unde sunt
eliminate elementele separabile folosindu-se un gratar des. Elementele separabile sunt
colectate si indepartate din sistem.
Dup epurarea mecanic, apele reziduale sunt
unde are loc epurarea biologic.
118
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
Valoare
Uniti
de
msur calculat
*tolerat
C
1317
1025
7
6,57,5
Valoare tolerat
deviaii
pe zi
pe or
2
23
0,10,2
0,3
m/zi
m/or
m/or
mg/l
100%
Gda/18
Gda/14
420
30100%
140420
10%
20%
mg/l
mg/l
mg/l
mg/l
mg/l
300
550
350
50
31
10
5,2
4,8
50
12,5
30
100
50
106
1000
100300
100550
0350
550
331
110
15,2
14,8
30300
012,5
050
50100
050
106108
5002000
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
buc./l
mg/l
119
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
9
8
7
6
5
pH intrare
pH iesire
3
2
1
0
3,2004
3,2005
3,2006
3,2007
3,2008
1600
1400
1200
1000
CCO-Cr (mg/dm3) intrare
800
600
400
200
0
3,2004 3,2005 03.,006 3,2007 3,2008
Eficienta de indepartare a CCO - Cr a fost intre 81% si 97%, valorile CCO-Cr in effluent
fiind cuprinse intre 34 si 114 mg/dm3 in limitele reglementate
120
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
140
120
100
80
60
40
20
0
3,2004
3,2005
32.006
3,2007
3,2008
Eficienta de indepartare a Azotului total a fost intre 73% si 99%, valorile Azotului total in
effluent fiind cuprinse intre 7,9 si 25 mg/dm3 in limitele reglementate
35
30
25
20
15
Fosforului total
(mg/dm3)iesire
10
5
0
3,2004
3,2005
3,2006
3,2007
3,2008
Eficienta de indepartare a Fosforul total a fost intre 48% si 89%, valorile Fosforului total in
effluent fiind cuprinse intre 0,52 si 5,28 mg/dm3 in limitele reglementate
121
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
pH intrare
7,6
pH iesire
7,5
7,4
7,3
9 ,200 7
10,2007
11,2007
500
450
400
350
300
250
200
150
100
50
0
9,2007
10,2007
11,2007
3
Eficienta de indepartare a CCO - Cr a fost intre 86% si 92%, valorile CCO-Cr in effluent
fiind cuprinse intre 28 si 56 mg/dm3 in limitele reglementate
122
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
50
45
40
35
30
25
20
15
10
5
0
9,2007
10,2007
11,2007
Eficienta de indepartare a Azotului total a fost intre 74% si 81%, valorile Azotului total in
effluent fiind cuprinse intre 8 si 12 mg/dm3 in limitele reglementate
14
12
10
8
Fosforului total
(mg/dm3)iesire
4
2
0
9,2007
10,2007
11,2007
Eficienta de indepartare a Fosforul total a fost intre 89% si 99%, valorile Fosforului total in
effluent fiind cuprinse intre 0,13 si 0,84 mg/dm3 in limitele reglementate
123
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
8
7,8
7,6
pH intrare
7,4
pH iesire
7,2
7
6,8
2,2007
3,2007
4,2007
5,2007
350
300
250
200
150
100
50
0
2,2007
3,2007
4,2007
5,2007
Eficienta de indepartare a CCO - Cr a fost intre 86% si 96%, valorile CCO-Cr in effluent fiind
cuprinse intre 10 si 12 mg/dm3 in limitele reglementate
124
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
50
45
40
35
30
25
20
15
10
5
0
2,2007
3,2007
4,2007
5,2007
Eficienta de indepartare a Azotului total a fost intre 66,6% si 81%, valorile Azotului total in
effluent fiind cuprinse intre 8 si 9 mg/dm3 in limitele reglementate
12
10
8
Fosforului total
(mg/dm3)iesire
4
2
0
2,2007
3,2007
4,2007
5,2007
Eficienta de indepartare a Fosforul total a fost intre 73,5% si 93,6%, valorile Fosforului total
in effluent fiind cuprinse intre 0,66 si 1,98 mg/dm3 in limitele reglementate
125
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
6. Concluzii
Din datele prezentate se poate concluziona ca:
- datorit adaptrii independente i auto-echilibrrii, procesul se desfoar fr
intervenia permanenta operatorului;
- Cnd se modific anumite condiii precum: temperatur, grad de mineralizare;
concentraia i proporia de substane nutritive din apele reziduale, - biocenoza i modific
independent structura cantitativ i calitativ, adaptndu-se la noile condiii.
- n caz de sarcini de oc de durat scurt, sistemul se regenereaz singur;
- Statiile de epurare tip RESETILOVs pot fi folosite pentru epurarea apelor uzate
menajere cu parametrii prevazuti de NTPA 002/2005;
126
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
ECODISK
M.Selo*, N. Schmitt*
*info@pmtwater.com
The treatment of the sewage plants of little communities needs rustic, economic systems,
easy to exploit, a few sensitive to the changes of organic and hydraulic charges, and this all
more than the installation has a small size.
Various systems have been used (sand filter, etc) and it appears today constraints or
dysfunctions sometimes important (problems of cleaning and evacuation of sludge,
insufficient level of rejection, clogging, smells).
ECODISK, Rotating Biological Disks or Biodisks, well conceived and correctly
calculated represent a solution particularly interesting to resolve these problems.
1. History
Rotating Biological Disks arrived in France at the end of the 60s attracted by their simplicity,
their rusticity, their reliability thanks to the fixed culture, and their functioning saving.
After many years of functioning we noticed that the installed material was not enough
reliable mechanically by its conception (expanded polystyrene disks, fragile, porous and
subject to oafs, wear of the chains and drive crowns, pulling up of the motors sealing under
the effect of the oafs, wear of the overloaded and insufficiently greased bearings, breaking of
the shaft, buckling of the tubes due to their big length which brings about plays and
disorganisation of the Rotating Biological Disks assembly, corrosion problems, etc).
Shaft made of chromium stainless steel without welding, with a reduced reach limited to 2
m between bearings.
y Motor well calculated, with direct coupling by
elastic muffs without chain or gable.
y
127
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Improvements useful to the good functioning have been carried out device of the flows
regulation, half-cylindrical tanks in order to avoid deposits.
By its conception and the employed materials, Rotating Biological Contactors have
resolved all problems met with on the first generation of Rotating Biological Disks.
Bio-disks
Final clarification or
lamellar separator
Wastewater
Treated water
Overflow or
Tertiary
treatment
Sludge storage
Sludge extraction
Sludge pump
3.1. Pre-treatments
These are carried out by a sedimentation and digesting device, (or by a compartmentalized
sedimentation tank) which handles the functions of screening, sand removal, removal of fats,
elimination of matter that can be sedimented, storage and digestion of excess sludge, and, if
needed, a buffer tank.
128
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
4. Advantages
4.1. Operational simplicity
Because of their open structure, the bio-discs cannot get choked up, and they carry out the
purification without needing any regulation, as the excess bacteria peel off automatically and
are swept away in the water.
The degree of reduction of the organic pollution can be adjusted depending on the specific
load (SL) expressed in g DBO5/m2 of bio-disc surface.
The e + NK1 level" can be reached at a temperature of 13C with an SL of 10 to 12 g
DBO5/m.
The treatment for nitrogen (NK2 level), requires an SL of the order of 5 to 6 g DBO5/m2.
Physico-chemical dephosphatization can be performed by simultaneous precipitation with
the addition of iron salts in the last section of the bio-discs ( PT1 level).
129
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
6. Applications areas
Rural communities
Hamlets market town
Camping
Housing development
Barracks
Hotel, holiday village
Mountains resort, winter sports resort
Work-site
Staff canteen
Reinstatement, modernisation and
development of existing sites
Some of the farm-produce and industrial
applications, etc
130
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Rezumat
n practica de proiectare curent a sistemelor de canalizare menajer pentru localitile mici,
reeaua de canalizare este considerat ca parte independent a sistemului de canalizare,
care are ca scop colectarea apelor uzate de la abonai si debueul acestora n staia de
epurare. Debitele de ap intrat n staie sunt aleatorii, diferind de la o or la alta, n funcie
de cronograma consumurilor de ap potabil, respectiv de programul diurn de activitate al
comunitii.
n prezent, calculul hidraulic al reelei de canalizare i al staiilor de pompare are n
vedere doar asigurarea capacitii necesare de transport spre staia de epurare, ct i de
autocurare a seciunilor de transport.
Potrivit conceptelor actuale, staia de epurare se dimensioneaz lund ca baz debitele
maxime orare pentru treapta de epurare mecanic i debitele maxime zilnice pentru treapta
biologic. n aceast situaie este interpus un bazin de omogenizare a debitelor i
ncrcrilor n amonte de staia de epurare.
Soluiile de automatizare aplicate n prezent pentru dirijarea i monitorizarea proceselor
din sistemul de canalizare-epurare realizeaz aceast funcie n corelare cu semnalele
transmise de senzorii instalai n sistem. Cu toate c prin proiectare se aplic o monitorizare
complet a componentelor individuale din reeaua de canalizare, pn acum nc nu s-a
urmrit mbinarea logic a tuturor acestor componente pentru a asigura o exploatare optim
a reelei sau chiar a sistemului retea-staie de epurare.
De asemenea, pn n prezent nu s-a urmrit mbinarea exploatrii staiei de epurare cu
dirijarea supraordonat a reelei de canalizare. O singur excepie o reprezint sistemul de
evacuare a apelor uzate sub presiune, la care operarea staiilor de pompare individuale
poate fi acordat prin sistem.
Experii n concepia i exploatarea sistemelor tehnico-edilitare apreciaz din ce n ce mai
mult avantajele unei uniti de dirijare supraordonate comun pentru ntreg sistemul de
canalizare - epurare. Avantajele acestui concept sunt evidente, ntruct staiile de epurare
sunt dimensionate de regul funcie de debite i ncrcri de vrf, iar o
uniformizare/echilibrare a debitelor influente ar avea drept consecin o staie de epurare mai
mic.
Soluia pe care o propunem implic dirijarea optim a staiilor de pompare din sistemul de
canalizare, pe baza utilizrii volumelor de retenie i a capacitii de stocare a apei uzate n
reeaua public de canalizare.
131
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
132
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
133
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
134
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Volumul mic al conductelor de transport, ct mai ales regimul de viteze mrit, impus
pentru vehicularea sub presiune a apelor uzate, conduc la diminuarea timpului de meninere
a apei reziduale n canalizare. n acest fel se prentmpin producerea unor fenomene de
fermentaie pe traseul reelei. n sistemele clasice de canalizare gravitaional, stagnarea
apei pe traseul reelei conduce la apariia n apa uzat a fazei de fermentaie anaerob
acid, care produce mirosuri dezagreabile i face ca apa s devin coroziv pentru betoane,
mai ales la contactul cu atmosfera, respectiv n zona gurii de deversare.
Un alt avantaj al transportului sub presiune a apelor uzate const n evitarea depunerilor.
135
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
din material plastic sunt asigurate mpotriva presiunii, fiind etane la apa freatic. Ele sunt
amplasate n sol, fr lucrri suplimentare de betonare. Datorit dimensiunilor constructive
compacte i a greutii reduse, instalarea se realizeaza rapid, necesitnd un volum de
excavaie minim. Cminele sunt livrate ca produse finite, prevzute cu toate armturile
necesare.
Montajul, ct i ntreinerea extrem de uoar a SPAU, sunt asigurate de sistemul de
conducte i instalatii electrice montate de furnizor care asigura efectuarea interventiilor
pentru cuplarea pompei din exterior.
Dotarea cminului este completat cu un clapet de reinere (clapet de sens unic), un
dispozitiv de blocare i un racord pentru instalaia de splare. Cminul dispune de asemenea
de o deviaie de presiune, ncepnd cu DN 40.
Sistemul de comand
Se pot realiza diverse concepte de comand: de la comanda cu electrocontacte la comanda
cu microprocesoare i de aici pn la telecomunicaie i acionare de la distan, dintr-un
punct central de comand.
Operarea pompelor funcie de nivel este asigurat prin intermediul a dou contactoare de
nivel ce lucreaz independent unul fa de cellalt, garantnd o siguran maxim n
exploatare.
136
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
137
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Prognozarea capacitii,
138
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Este posibil ca prin sistemul de dirijare s se adapteze n mod optim ansamblul format din
reeaua de canalizare i staia de epurare, la regimul de variaie orar a debitelor de
canalizare.
Considerarea funcionrii celor dou sisteme total independente unul fa de cellalt, are
drept consecin dimensionarea staiei de epurare la debitele de vrf, n timp ce n canalizare
conductele erau dimensionate ori prea mari ori prea mici, ceea ce a dus fie la o
suprasolicitare a staiei de epurare, fie la o subsolicitare. Asemenea dezavantaje sunt
remarcate acolo unde s-au produs modificri n structura populaiei i deci i a cantitilor de
ape uzate, fa de cele calculate i proiectate n baza prognozelor anterioare.
Sistemul integral de dirijare nlesnete adaptarea n timp a ntregului sistem de
canalizare-epurare la transformrile demografice, cauzate de migraia populaiei sau
reducerea natural a numrului de locuitori.
De asemenea acest sistem nlesneste coordonarea optim a fluxurilor de ape uzate n
sistem. Astfel, dac volumul de stocare din reeaua de canalizare este epuizat la un anumit
moment dat, sistemul verific ce debit poate fi tratat n staia de epurare (operaiune PUSH),
i n functie de acesta, regleaz regimul de funcionare. Sistemul mai poate asigura
aprovizionarea staiei de epurare cu debite de ape uzate n perioadele de reducere natural
a debitelor canalizate, de exemplu pe perioada nopii (operaiune PULL).
nregistrarea on-line i interpretarea permanent a procesului pe baza datelor stocate,
care evideniaz anumite regimuri de funcionare istorice, garanteaz o evoluie normal a
sistemului.
Asfel se realizeaz o baz de date sigur, pentru luarea deciziilor i a realizrii
prognozelor pe termen lung.
nregistrarea detaliat a tuturor cantitilor de ape uzate de la fiecare gospodrie i/sau
productor de ape uzate permite decontarea exact a taxelor pentru ap uzat, precum i o
evaluare exact n cazul introducerii eronate a unor volume de ap n reea sau a unor cazuri
de daune.
Unitile descentralizate de automatizare i comunicaie instalate la staia de pompare
SPAU asigur nregistrarea variaiei nivelurilor de ap din bazinul staiei, a consumului de
energie, a presiunii manometrice, i sesizeaza toate datele, n special perturbaiile din
sistemul de canalizare. Toate aceste date din sistemele pariale sunt nregistrate de sistemul
integral de dirijare, care evalueaz i prelucreaz datele pentru dirijarea supraordonat a
procesului. Un flux perfect de date este garantat prin interfee de comunicare, pentru
realizarea unei comunicri LAN conform normei europene IEC.
Posibilitatea de a influena fluxul apelor uzate i ncrcarea lor ntr-un sistem total, format
din reeaua de canalizare i staia de epurare, determin i dimensionarea staiei de epurare.
Un exemplu: O staie de epurare cu sistem integrat HST-SBR pentru o cantitate de
aduciune de 1000 mc/zi (cca. 6700 LE) va fi dimensionat dup normele internaionale
convenionale (fr sistemul integral de dirijare a sistemului) ca i cnd toat cantitatea de
ap uzat ar sosi la staia de epurare n timp de 10 ore, deci staia va fi dimensionat pentru
a putea prelua debitele i ncrcrile maxime orare.
139
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
10 ore
100 m/h
226 m
16 ore
63 m/h
141 m
24 ore
42 m/h
94 m
1402 m
125 Nm/h
30 kW
3 kW
1297 m
115 Nm/h
25 kW
2 kW
1238 m
110 Nm/h
22 kW
1,5 kW
Dup cum se poate vedea n tabelul de mai sus, conducerea unitar a sistemului asigur
reducerea volumului bazinului de compensare i omogenizare cu peste 50%, iar pentru
bazinul SBR volumul poate fi redus cu 10%. Necesarul de oxigen scade, capacitatea
suflantelor poate fi redus, n final realizndu-se economii importante de investiie i energie.
Cu ct mai mare este cantitatea ncrcrilor intrate n staia de epurare, cu att mai mari
sunt posibilitile de reducere a costurilor.
Concluzii
Sistemul integral de dirijare prezint urmtoarele avantaje:
Asigur echilibrul ntre fazele cu debite i ncrcri de vrf i cele cu sarcini reduse
140
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Zoltn Natchev*
RobEx Automatizri S.R.L., 410605, Oradea, os. Borului, Nr. 40, E-mail: natchev@robexrom.ro
Istoric
Trgu Mure dispune de o reea de canalizare de 236 km. O mare parte a acesteia constituie
un sistem unificat, adic apa rezidual i cea pluvial sunt colectate ntr-un canal comun.
Reeaua de baz a fost construit n 1910. n vederea micorrii solicitrii canalelor n caz de
precipitaii abundente s-au construit deversoare n diferite puncte ale reelei, astfel o parte
din apa rezidual amestecat cu cantiti mari de ap pluvial este dirijat ctre canalele
deversoare.
Deversoarele au fost proiectate astfel nct numai apele diluate, cu un coninut sczut de
impuriti, s ajung n canalele deversoare, iar din acestea n emisar (direct, sau prin
prurile adiacente indirect, n rul Mure).
Descriere
Scopul proiectului este modelarea reelei de canalizare. ns pentru atingerea acestuia este
necesar calibrarea modelului obinut pe baza msurrilor reale. Avnd la baz modelul
calibrat, se poate stabili, care deversoare trebuie reconstruite astfel nct s corespund
normelor UE n privina raportului ap pluvial/ap rezidual, considernd de asemenea
extinderea ulterioar a reelei.
Sarcina firmei Robex a fost realizarea msurtorilor necesare calibrrii i asigurarea
rezultatelor. Cerinele impuse msurtorilor: n cazul nivelului n domeniul 50 mm...2 m
precizie de +5 mm i rezoluie de 2 mm; n cazul vitezei de curgere n domeniul 0,2...3 m/s
precizie de + 0,05 m/s i rezoluie de 0,01 m/s; execuie antiex.
n cadrul campaniei de msurare s-a utilizat debitmetrul ultrasonic PCM Pro, cu
funcionare pe baza principiului corelrii ncruciate, productor Nivus GmbH. Acest aparat
satisface n totalitate cerinele de mai sus.
141
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
n dou locuri au existat i staii de distribuie, n cazul acestora s-au msurat evident
ambele ramuri. Dei exist posibilitatea msurrii cantitilor deversate, aceasta nu mai
avea rost, deoarece ea se poate calcula cunoscnd cantitile totale de influent i efluent la
deversori. Un punct de msurare a fost instalat n canalul bazinului de avarie.
Deoarece, ncepnd cu primul deceniu al secolului trecut i pn astzi, reeaua de
canalizare este n permanent construcie i dezvoltare, fazele i perioadele de construcie
putnd fi clar distincte, am putut ntlni diverse forme ale seciunii canalelor (circulare,
ovoide, semicirculare, etc.). Materialul canalelor este betonul.
142
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
n mod interesant canalele i cminele construite cu aproape 100 de ani n urm sunt
ntr-o stare mai bun, dect cele care au o vrst de numai 30-40 de ani. Acest fapt
dovedete ns regresul construciilor...
Montarea i instalarea senzorului se realizeaz diferit n funcie de forma seciunii
canalelor. Montajul este mai dificil n cazurile n care exist depuneri de 10-20 cm, de diferite
structuri (afnat sau compact), ntlnite n zonele cu un unghi de nclinaie mai mic. Cel
mai simplu a fost montajul n seciunile circulare, unde condiiile hidraulice nu au permis
formarea depunerilor. n aceste puncte de msurare am utilizat dispozitivul tip colier (utilizabil
la diametre de la 20 cm chiar i pn la 1 m), reducnd semnificativ timpul montrii. Aceast
soluie s-a dovedit a fi aplicabil i la seciuni ovoide de dimensiuni mai mici (30/45, 40/60).
n celelalte locuri senzorii au fost montai pe o tabl special care la rndul ei a fost fixat
pe fundul i pe peretele canalului sau n alte cazuri pe cei doi perei ai canalului, cu ajutorul
uruburilor. Dac am ntmpinat depuneri solide, tabla a fost fixat de aceasta. n cazul
depunerilor moi s-a aplicat scoaterea senzorului peste nivelul depunerilor cu ajutorul unui
suport, sau senzorul a fost montat n lateral, pe peretele canalului. n aparat se pot introduce
dimensiunile stratului de depuneri respectiv nlimea suportului sau mrimea deplasrii
senzorului, astfel rezultatul este n continuare debitul exact, nefiind necesare alte calcule de
corecie.
143
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Nivelul mediu al apei n timpul instalrii n majoritatea cazurilor a fost de 5-35 cm. n cazul
colectoarelor principale (n aval de deversori) nivelul a fost i mai mare, chiar i n perioade
lipsite de precipitaii, astfel pe timpul lucrrilor de instalare a fost necesar redirijarea apei n
staiile de distribuie pe cealalt ramur de canal.
Datele msurate au fost extrase sptmnal din mediul de stocare al aparatului (card
CompactFlash). Aceste date au fost predate proiectanilor n format Microsoft Excel (.xls).
Datele sptmnale (nivel, vitez de curgere, debit) extrase din fiecare aparat au fost
reprezentate i grafic. Pe graficele trasate se pot identifica ciclurile zilnice ale perioadelor
lipsite de precipitaii, respectiv influena evenimentelor de precipitaii.
144
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Concluzii
n concluzie se poate constata c modelarea reelei este un proces complicat, n care este
nevoie de colaborarea experilor furnizorului de servicii de canalizare, ale proiectantului i ale
firmei care efectueaz msurtorile. Numai prin aceast colaborare se poate asigura
invizibilitatea canalizrii apelor reziduale i pluviale.
145
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Aurel Presura *
ing. Director Tehnic SC RAJA SA
Summary
With regard to the operation of the modern wastewater treatment plants, the electricity costs
represent an important component of the WWTPs operational costs, estimated at ~ 30-35%.
Considering the program for extension of the wastewater treatment plants in the county in
the following years, foreseen by the Sectorial Operational Programme for Environment (SOP
ENV), which comprises over 50 small and medium WWTPs, SC RAJA SA Constanta
initiated a project for modernization of Poarta Alba Waste Treatment and Energy Recovery
Facility.
The new wastewater treatment plant will assure the treatment of wastewaters for a
population of ~ 25,000 inhabitants, including Poarta Alba, Murfatlar and Valu lui Traian
localities.
The modernization of the energetically independent wastewater treatment plant is based
on an American concept which propose the use of the locally available biomass sources, as
well as other renewable energy systems as wind turbines.
The article comprises a description of Poarta Alba project which assures the energetic
independence of the Wastewater treatment plant, a solution that could be extended also to
other wastewater treatment plants which have the capacity to assure renewable additional
sources of energy.
SC RAJA SA este al doilea mare operator in domeniul alimentarii cu apa a populatiei din
Romania, dupa Bucuresti si are ca actionari Consiliul Judetean Constanta si un numar de 33
de Consilii Locale. Deserveste o populatie de peste 577.000 de locuitori din 10 orase si 44
de localitati din Judetul Constanta, care in sezonul estival ajunge la 2.000.000 datorita
turismului
RAJA detine si opereaza in prezent un numar de noua statii de epurare, din care doua
sunt modernizate prin programe europene, doua sunt in curs de modernizare si se
intentioneaza sa se modernizeze si celelalte cinci statii.
146
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Prin Programul Operational Sectorial de Mediu (POS Mediu) sunt propuse a se construi
opt noi statii de epurare pana in anul 2013, iar pana in anul 2018, RAJA intentioneaza sa
modernizeze si sa construiasca 54 de statii de epurare pentru a se conforma la
angajamentele asumate de Guvernul Romaniei fata de Uniunea Europeana. In total este
estimata o investitie de peste 230 milioane in sectorul de apa uzata pana in anul 2015, in
scopul de a se asigura colectarea si epurarea apei uzate pentru comunitatile de peste
10.000 locuitori.
O prioritate importanta pentru RAJA o reprezinta costurile de exploatare ale acestor statii
de epurare, in mod deosebit costurile energetice. Pornind de la acest deziderat, SC RAJA
SA si-a propus sa modernizeze Statia de epurare Poarta Alba, care sa devina independenta
din punct de vedere energetic.
147
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Luna
Ianuarie
Februarie
Martie
Aprilie
Mai
Iunie
Iulie
August
Septembrie
Octombrie
Noiembrie
Decembrie
Total
Tabelul 1
Anul
2006
23527
23626
24542
23807
21732
19383
18420
23931
20594
21230
20893
24437
266122
2007
22186
20391
20677
18663
17408
16997
17288
19671
20654
20488
20510
21200
194383
Din acest tabel se constata ca media de consum lunar este de 22.000 kwh, iar cea
anuala este de 250Mwh.
Noua propunere de proiect este pentru o statie de epurare care sa deserveasca o
populatie de aproximativ 25.000 de locuitori, incluzand Poarta Alba, Basarabi si Valu lui
Traian.
Realizarea acestui concept impune aplicarea urmatoarei strategii in proiectarea statiei de
epurare:
- Caracterizarea completa a debitului de apa uzata influent, curent si viitor, si a
incarcarilor de la Statia de epurare. In urma procesului de epurare a apelor uzate,
cantitatea de namol preconizata este de aproximativ 3800 t/an.
- Identificarea tuturor surselor de biomasa din zona. Podgoria Murfatlar produce
anual aproximativ 6000 tone de reziduuri organice, ferma de animale Poarta Alba produce
70 tone balegar pe luna, ferma Valu lui Traian 60 tone de balegar pe luna, iar inchisoarea
Poarta Alba 1,5 tone de grasimi pe luna, alte reziduuri disponibile fiind cele agricole: rapita si
porumbul.
- Sursele de energie suplimentara valorificand potentialul eolian din zona. Conform
studiului facut de Agentia Romana pentru Conservarea Energiei privind potentialul eolian
reiese ca Dobrogea, in special zona Murfatlar-Poarta Alba, reprezinta regiunea cea mai
148
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
favorabila instalarii turbinelor eoliene, cu o viteza medie anuala a vantului cuprinsa intre 5.0
si 11,5 m/s. (Fig.1).
Fig.1
Noul concept privind abordarea tehnica a SE Poarta Alba este indicat in Fig. 2:
Fig.2
Nota: Descarcarea se face in Canalul Dunare-Marea Neagra.
Etapele de producere a energiei in urma procesului de epurare se prezinta astfel:
1. debitul de apa uzata cu incarcarea specifica intra in statia de epurare
2. are loc procesul de prelucrare a apei uzate in urma caruia rezulta namolul
3. se adauga sursele suplimentare de biomasa
4. namolul si biomasa colectata sunt transformate in gaz
5. gazul este transformat in energie.
Avand in vedere aporturile de biomasa previzionate, tehnologiile folosite in SUA vor fi
evaluate raportat la ultimii doi pasi pentru a determina care este cea mai potrivita.
149
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Tehnologiile care vor fi avute in vedere pentru Pasul 4 includ gazificarea si fermentarea
anaeroba. Tehnologiile avute in vedere pentru Pasul 5 includ motoarele cu pistoane,
celulele de combustibil, microturbinele si turbinele cu abur.
Completarea necesarului de energie pentru functionarea in parametrii a statiei de epurare
se face prin aport de energie eoliana (Pasul 6). In proiect s-a prevazut amplasarea a uneia
sau a doua turbine eoliene in incinta SE Poarta Alba.
Capacitatea totala a statiei de producere a energiei va fi cuantificata si evaluata raportat
la necesul energetic al statiei (Pasul 7). Reziduurile de biosolide vor fi evaluate in ceea ce
priveste pretabilitatea acestora pentru reutilizare locala (Pasul 8). Va fi evaluata necesitatea
unei tratari suplimentare, ca de exemplu compostarea sau pasteurizarea.
Costurile estimate pentru executia SE Poarta Alba sunt prezentate in tabelul 2:
Tabelul 2
Costurile de capital
Statia de epurare
Manipularea/Fermentarea namolului
Unitatile de transformare a gazului in energie
Turbina (turbine) eoliene
Subtotal
Constructii si neprevazute
Total
Costurile estimate ()
5.000.000
2.000.000
170.000
270.000
7.170.000
1.500.000
8.940.000
150
Costuri estimate
714.000
100.000
135.000
949.000
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Tabelul 4
Venituri anuale
Tarif canalizare
Valoare energie produsa
Tarif de basculare
Certificate verzi
Total
Venituri estimate
1.015.000
90.000
1.105.000
Bibliografie:
1. Proiect Studiu de Fezabilitate SE Poarta Alba executat de PROED SA Bucuresti, 2006
2. Propunere proiect Reabilitare SE Poarta Alba executata de Coler&Colantonio SUA, 2008
151
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
This study regards the pollution of water sources by modifying their physical, chemical and
microbiological indicator parameters over admitted limits, which make water improper to the
purposes for which it had been used previously as sources for water supply systems.
The phenomenon may have a long-term nature, which is a transient alteration of the
balance between aquatic ecosystems with ecological and economical effects.
The presence of polluting compounds depends on the human activities and the
geological characteristics of the penetrated grounds.
The detection of the pollutants is made by quantifying them and determining the physical,
chemical and microbiological indicator parameters.
We recommend the use of water sources which observe the conditions specific to water
used for water treatment.
152
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
153
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Tinand cont de faptul ca apele uzate care provin dintr-o serie de mari intreprinderi si
combinate industriale, contin importante cantitati de petrol, fenol, metale grele, detergenti,
pesticide, fertilizanti etc. substante care exercita efecte deosebit de nocive asupra florei si
faunei acvatice, ca .si asupra sanatatii si confortului populatiei. Ne vom referi succint la
citeva din aceste principale genuri de poluari :
Daca unii poluanti cum ar fi de pilda detergentii, pesticidele, fenolii, reziduurile petroliere
etc. in concentratiile in care se intilnesc de regula in apele de suprafata si respectiv in apele
de baut, nu determina efecte toxice evidente, ele produc in schimb modificari intense ale
proprietatilor organoleptice ale apei, perturba si ingreuneaza procesele de prelucrare a apei
de suprafata in scop potabil si pentru alte necesitati, exercita efecte daunatoare asupra
culturilor irigate cu astfel de ape etc.
Alti poluanti cum ar fi : metalele grele, cianurile, nitratii si altele, atunci cand ating
concentratii crescute in apa sau in produsele acvatice ce servesc de hrana omului (peste,
scoici etc.), pot exercita efecte toxice sau chiar letale (Draghici, Perniu, 2002).
Vom mentiona in sfarsit si existenta unei poluari naturale, in parte inevitabila,
determinata de constitutia geologica particulara a solului care constituie bazinele de
alimentare ale unor surse de apa sau, alteori, de prezenta in apa a unor substante care sunt
rezultatul unor sinteze realizate de organismele telurice si acvatice.
154
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
155
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
se clorfenoli, care poseda un gust si miros intens, asemanator iodo-formului, cunoscut sub
numele de miros de farmacie. Acest miros si gust se produc prin actiunea clorului asupra
apei care contine chiar si numai citeva grame de substante fenolice. Cu ani in urma s-au
semnalat urme fine de fenoli in raul Prut
156
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
157
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
S-au intalnit insa si situatii cind apa de fantina continea cantitati crescute de nitrati, fara
nici un semn de poluare. In aceste cazuri nitratii proveneau din depozitele de nitrati existente
in mod normal in sol (origine telurica). Mentionam in sfirsit posibilitatea ca nitratii sa creasca
in sursele de apa, in cele de surafata indeosebi, ca urmare a deversarilor de ape reziduale
provenite din intreprinderile si combinatele care prepara fertilizante.
158
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
de numerosi alti autori care, in plus, subliniaza si corelatia dintre tumorile pleurei si
peritoneului si expunerea omului in industria azbestului si in vecinatatea ei. Asocierea intre
cancerul pulmonar si expunerea la azbest a fost constatata intai in industria textila din Marea
Britanie. Anchete necropsice efectuate au aratat proportii crescute de cancer pulmonar
printre azbestozici iar alte investigatii clinice efectuate au confirmat aceasta asociere.
159
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
160
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
161
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Nr
crt
1
2
3
4
5
6
7
8
9
10
11
Valoare
admisa
0,5
0,1
0,5
50
0,005
0,05
0,001
0,005
0,1
1
0,001
Din verificarile pe teren, s-a constatat ca poluarea a fost cauzata de evacuarea de ape
incarcate organic, cu irizatii de natura petroliera si uleiuri neidentificate, printr-un colector de
pe malul stang al raului Prut, localitatea Ungheni - Republica Moldova, situat in zona amonte
pod CF Iasi - Ungheni . S-a oprit evacuarea apelor uzate prin conducta din localitatea
Ungheni - Republica Moldova.
In urma poluarii produse, nu s-au inregistrat modificari semnificative asupra ecosistemului
acvatic si nici mortalitati piscicole.
162
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Concluzii
Identificarea la timp, a tuturor poluantilor nocivi / cancerigeni si
potential asupra sanatatii umane ;
estimarea riscului
Referinte bibliografice
Teodosiu, C. (2001)Tehnologia apei potabile si industriale, Ed.Matrix Rom, Bucuresti.
Draghici, C. si Perniu, D. (2002) Poluarea si monitorizarea mediului, Ed. Universitatea Transilvania, Brasov
Simionescu, C.M. si Stanescu, R. (2002) Poluarea si protectia mediului, Ed. Printech, Bucuresti
NTPA -001/2002, privind stabilirea limitelor de incarcare cu poluanti a apelor uzate industriale si orasenesti la
evacuarea in receptorii naturali.
NTPA - 002/2002, privind conditiile de evacuare a apelor uzate in retelele de canalizare ale localitatilor si
direct in statiile de epurare.
163
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Abstract
Nmolul activ al unei staii de epurare ape uzate,prevzut cu treapt biologic de tratare,
este un ecosistem creat artificial, cu rol important n reducerea concentraiilor de substan
organic i de nutrieni deversae n emisar (Madoni, P., Gugliermi, L..2005). Prin analiza
biologic la microscop a acestei culturi mixte de microorganisme, meninute n condiii
limitative i cu o structur variabil funcie de factori interni i externi, se obin informaii
importante asupra caracteristicilor de epurare la un moment dat i a condiiilor de procesare
din staie, precum i asupra compoziiei apei uzate influente ct i calitatea efluentului final.
Keywords: Ap uzat, biologie, nmol activ, staie de epurare
164
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Arcella sp.(100X)
Zooflagelatele, prezente in namol intr-un procent semnificativ de 13%, indica prezenta de
substante organice in fermentare si intra in bazinele de aerare odata cu infuentul statiei, din
canalizare, unde se gasesc in numar ridicat. Valoarea sulfurilor totale la intrarea in statie
este de 2-3 mg/l, valoare peste cocentratia maxim admisa, dar faptul ca procesele de
epurare biologica se desfasoara eficient este atestata de concentratia medie de 1mg/l la
efluentul final..
Fitoflagelatele apar in bazinele de aerare odata cu influentul diluat, sau in perioada
ploilor.reprezinta 8% din microfauna.
Ciliatele reptante, prezente cu un procent semnificativ in namol, de 17%, si dintre
acestea ca specie dominanta Aspidisca sp., indica obtinerea unor randamente bune de
indepartare a incarcarii organice si a desfasurarii nitrificarii, atestate prin valori de 30mg/l
CBO5 la efluentul final.
Prezenta lui Euplotes sp. in biocenoza este legata de infuzia de apa diluata pe treapta
biologica, cu incarcare organica mica, indica eficienta epurativa buna si namol cu capacitati
bune de sedimentare in decantorul secundar.
Ciliatele fixate reprezinta 12% din microfauna namolului. In cadrul acestui grup ca specie
dominanta se observa Cothurnia sp. ce indica tot desfasurarea unui bun proces de
nitrificare, incarcare organica mica-medie a namolui si oxigenare eficienta.
165
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
166
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Referine
Catrina, V., Dimitriu, G., i colab.(2006) Monitorizarea parametrilor tehnologici de epurare biologic n Staia de
tratare a apelor uzate din municipiul Iai. Conferina internaional Sigurana sistemelor de alimentare cu ap
i canalizare,ARA.
Chierici, E., Madoni, P., (1991) Comparative analysis of the activated sludge microfauna in small municipal plants.
Biological aproach to sewage treatment process, (83-87).
Curds, C. R., (1973) The role of protozoa in activated-sludge process. American Zoologist 13 (161-169).
Delgado, A.F., Campos J. G., Vazquez J.R. (1996) Protozoos como bioindicadores en procesos de depuracion
biologica Arranque de la EDAR de Aquadulce (Sevilla). Tecnologia del agua 155 (33-40).
performance of activated sludge plants based on the microfauna analysis. Water Research, 28 (1), 67-75.
Madoni, P., Gugliermi, L.,(2005) Elementi de la biologia della depurazione. n Depurazione biologica nei fanghi
attivi. De la Universita degli studi di Parma.
Madoni, P. (1994) A sludge biotic index (SBI) for the evaluation of the biological performance of activated
sludge plants based on the microfauna analysis. Water research 28 (67-75)
Madoni, P., (2005) La mirofauna del fango attivo in Depurazione biologica nei fanghi attivi de la Universita degli
studi di Parma.
Motta, M., Amaral,A.L.,Pons, M.N., Vivier H. (2001) Estudo por anlise de imagem do comportamento de uma
estaao de tratamento de efluentes sob condies transientes. Energias Renovables y Medio Ambiente 9,
( 49-55).
NTPA 003/2005 Metodologie de conducere a procesului de epurare biologic aerob cu nmol activ n staiile
de epurare a apelor uzate- Anexa 1 la Ordinul Ministerului apelor, Pdurilor i Proteciei mediului.
Sear-Brown, M.R., Collins, F., (2003) Activated sludge microbiology problems and their control. The 20-th Annual
USEPA National Operator Trainers Conference, NY.
Vazquez, J.R., Delgado, A., Sosa, E.G., Tello,A.D. (1999) Bioindicadores del fango activado y su relacion con el
rendimiento de la EDAR El Rompido (Huelva). Tecnologia del agua 193 (41-54 ).
167
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Fin + FR
Influent
Fin
Aeration
basin
Secondary
clarifier
Waste sludge
Fw
Recycle sludge
FR
Aeration basin: Pre-treated wastewater is mixed with activated sludge, containing the micro
organisms which transform and eliminate the organic pollutants in the wastewater by means
of bio catalysis. Oxygen must be supplied. Usually this is accomplished by blowing air in the
mixed liquor (the mixture of water and activated sludge).
Secondary clarifier: The activated sludge is separated from the purified water under the
influence of gravitation. The major part of the settled sludge is sent back to the aeration
basin. Part is wasted to keep the growing biomass in the system at certain level.
168
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
F ( z, t ) = u C + v C
Where:
C
F
=
t
z
The question that arises is Is it possible to derive the mass balance model such that a
limitation of flux is implicitly included? A possible solution to the above question and to that of
the presence of spatial gradient in settlers is indeed to introduce a second order derivative
term with respect to z in the mass balance model. A possible interpretation of such a term is
that it represents diffusion following Ficks law. In such a case, the flux F is written as
follows:
F = u C v C Da
C
z
C
C (v C )
2C
= u
+
+ Da 2
t
z
z
z
If v = v 0 e aC , v 0 , a > 0 (Vesilind model) then
C
C
2C
= u (1 a C ) e aC
+ Da 2
t
z
z
Equivalent with:
C
C
2C
+ u (1 a C ) e aC
= Da 2
t
z
z
The modelling is based on the measurements made in the purification stations for wastewaters IAWPRC (Henze et al. 1992) and CEIT, San Sebastien, Spania. Several zones can
be distinguished in a secondary clarifier (Figure 2). The height of each zone can be
calculated separately using empirical formula (Billmeier 1992).
For the clarifier zone,
u = u0 =
Fin Fw
Ase
with Ase the cross-sectional surface of the circular clarifier, and the boundary conditions are:
C ( H 1 , t ) = C in ,
169
C (H 2 , t) = 0
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
u = ub =
FR + Fw
Ase
C ( H 1 , t ) = C in ,
C (0, t ) = C R
Clarifier
z=H2
Effluent
Fin - Fw
Fin + FR
Feed
z=H1
Influent
z=0
Settler
FR + Fw
Figure 2. The different zones in a secondary clarifier.
t
C j +1 C i j
C
= i
t
t
tj+1
=
+
z 2 2z
2 z
*P
tj
0
xi-1
xi
xi+1
=
+
2z 2
2z
z 2 2
170
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
C C
2C
= F z, t , C ,
,
2
z t
z
with
F = f1 (z, t , C )
C
C
+ f 2 (z, t , C )
z
t
Ci
2
z
j+
j + 12
1
1
j
j
j
C
= F iz; j + t ; C i ; z C i ;
C i ,
t i
2
1
2
Ci
j+
1
2
i = 0, n
Correction step:
1 2 j +1
z C i + z2 C i j = F iz;
2
( j + 1)t;
Ci
j+
1
2
1
1
z C i j +1 + z C i j ;
C i j +1 C i j
t
2
where
z Ci j =
C i +j 1 Ci j1
;
2z
z2 C i j =
C i j+1 2C i j + C i j 1
z 2
4
3.5
3
height [m]
2.5
2
1.5
1
0.5
0
2000
4000
6000
8000
10000
12000
concentration [g/m ]
171
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
100
90
80
height [m]
70
60
50
40
30
20
10
0
2000
4000
6000
8000
10000
12000
14000
16000
concentration [g/m ]
Figure 5 Simulated suspended solids concentrations with experimental dates.
Example:
u 0 = 17.6 m / d ,
Da = 13 m 2 / d ,
H 1 = 2.51 m,
u b = 16.5 m / d ,
v0 = 370 m / d ,
a = 4.16 10 4 m3 / g
H 2 = 3.66 m
In this study model parameters were assessed based on an analysis of field and pilotscale experimental data. Results of the analysis are presented in Figure 5, where the
logarithm of the solids concentration is plotted as a function of depth. A logarithmic scale was
chosen for the solids concentration to provide more detail at lower concentrations.
Conclusions
In this paper, we have demonstrated the versatility of the Crank Nicholson scheme,
unconditionally stable, with regard to the modelling and simulation of activated sludge
processes in the secondary clarifiers. A multi-layer model of the clarification/ thickening
process was presented. Based on the solid flux concept and a mass balance around each
layer of a one-dimensional settler, the model is designed to predict the solids profile along
settling column, including the effluent and underflow suspend solids. The model was applied
to the one pilot scale and full scale experimental data with good results.
172
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
References
Anderson H. M. and Edwards R. V., (1981) Afinite differencing scheme for the dynamic simulation of continuous
sedimentation, AIChE Symp. Ser. 77 (Water), 227-238.
Berzins M., Dew P. M. and Furzeland R. M., (1989) Developing software for time-dependent problems using the
method of lines and differential-algebraic integrators, Appl. Numer. Math. 5, 375-397.
Billmeier E., (1992) Dimensioning of Final Settling Tanks of Large Activated Sludge Plants for High Quality
Effluent. Wat. Sci. Tech., 25 (4-5), 23-34.
S. H. Cho, et al, (1993) Settling Velocity Model of Activated Sludge, Wat. Res. Vol. No. 7, pp. 1237-1242.
D. Dochain, (1997) Modelling the Dynamics of Settlers: A Basic Problem, Med. Fac. Landbouww. Univ. Gent,
62/4b.
J. Hamilton et al, (1992) Modeling and Pilot-Scale Experimental Verification for Predenitrification Process, Journal
of Environmental Engineering, Vol. 118, No. 1.
Henze M., R. Dupont, P. Grau and A. de la Sota, (1992) Characterization of wastewater for modelling of activated
sludge process, Wat. Res. 27, 231-236.
Kenneth F. Cacossa and David A. Vaccari, (1994) Calibration of a Compressive Gravity Thickening Model from a
Single Batch Settling Curve, Wat. Sci. Tech. Vol. 30, No. 8, pp. 107-116.
Pennington S. V. and Berzins M., (1994) New NAG Library software for first order partial differential equations,
ACM Trans. Math. Softw. 20, 63-99.
Roe P. L., (1981) Approximate Riemann solver, parameter vectors, and difference schemes, J. Comput. Phys. 43,
357-372.
173
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
174
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Sectiunea 3
MANAGEMENTUL SISTEMELOR DE
ALIMENTARE CU APA SI CANALIZARE
175
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
176
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Rezumat
Realizarea de noi sisteme de ap-canal sau dezvoltarea celor existente, de mici dimensiuni,
din mediul rural, impune operarea acestora dup cele mai noi sisteme de management
pentru atingerea performanelor preconizate.
Lucrarea i propune s ofere elemente, date, proceduri i etape de aplicare la sistemele
de ap-canal a unui sistem de management integrat calitate-mediu-sntate securitate
ocupaional.
Abstract
The development of new small or medium size water/wastewater systems or the
development of existing ones, in rural environment, imposes operating them accordingly to
the newest management systems in order to achieve the best previewed performances.
The paper will offer some elements, data, procedures and stages in the applying the
integrated quality-environment-health management systems at water/wastewater companies.
177
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
se recomand s abordeze n sistem integrat cele trei problematici. Se obin astfel anumite
avantaje, dintre care citm:
-
coordonare intern eficient a celor trei specialiti sau echipe, ce sunt implicate n
certificarea organizaiei, conform celor trei sisteme;
Ca elemente definitorii pentru demararea aciunilor de certificare pe cele trei sisteme, ntro viziune integrat, care pot asigura succesul demersului, sunt de remarcat urmtorii pai:
-
178
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
179
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Politica Managementului. n toate cele trei cazuri trebuie acionat conform ciclului din
schema de mai jos (figura nr. 1) :
mbuntire i adaptare
continu
Evoluii n
domeniile MCS
Politic i declaraie
MCS
Analiza efectuat
de management pe sistem
integrat
Planificare
integrat
Verificare i aciuni
corective pe
componentele
managementului
integrat
Implementare i
funcionare pe
componentele
managementului
integrat
180
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
funciei de performanele realizate. Este foarte important a se face toate eforturile de ctre
conducerea organizaiei pentru a se realiza contientizarea la toate nivelele organizaiei, ca
aplicarea SMI aduce mari avantaje, n special din punct de vedere al performanelor interne
economice, tehnologice, sociale etc.
181
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Instruirea reprezentanilor
multidisciplinare;
managementului
organizaiei
echipei
Concluzii
Implementarea integrata la operatorii hidroedilitari de dimensiuni mici si mijlocii a celor trei
sisteme de mediu-calitate-sntate ocupaional ca un concept global de management
confer multiple avantaje dintre care citm:
- reducerea pierdelor economice;
-
relaii mai bune ale operatorilor cu bnci, firme de asigurare, administraia local;
Bibliografie:
1. Sisteme de management integrat pentru ageni economici, Prof.univ.dr.ing. Vladimir Rojanschi,
Asist.univ.drd.ing. tefan Duduman, ef lucrari dr. Florian Grigore, Editura Tribuna Economic, 2007, ISBN
978-973-688-088-9;
2. * * * SR EN ISO 14001 Sisteme de management de mediu Cerine i ghid de utilizare;
3. * * * SR EN ISO 9001 Sisteme de management al calitii Cerine;
4. * * * OHASAS 18001 Sisteme de management al sntii i securitii ocupaionale Specificaie.
182
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Abstract
The complex and long standing activities developed in any entity that provides water supply
and sewerage public services, from water catchement to discharge of the waste water into
emissary, requires management means, a strategically organization, planning and approach
that should be based on techniques and tool to protect the environment, having as ground
the promotion of the development concept of sustainable development. By acquiring of this
concept, in conditions of respect for the environment where we live, we can keep the
inheritance for the good of the next generations.
The accurate identification of the environment issues, respectively of the past, present
and potential impacts on the environment produced by the entitys activity has the primordial
role in implementation of environment management system.
The paperwork shows the process of environment issues identification and associated
impact assessment, as well as two methods for evaluation that can be used by the provider
of water supply and sewerage public services that implement an environment management
system with the purpose to improve the performances in this field in small and middle size
communities.
1. Introducere
Managementul de mediu este o component a sistemului de management general care
include structura organizatoric, activitile de planificare, responsabilitile, practicile,
procedurile, procesele i resursele pentru elaborarea, implementarea, realizarea, analizarea
i meninerea politicii de mediu (conform standardului internaional ISO 14050).
Un sistem de management de mediu (SMM) ajut organizaia s reduc la minim
impacturile asupra mediului. El prezint foarte multe avantaje i de aceea este important
implementarea i funcionarea acestuia. Atingerea acestor deziderate depinde de eforturile
fcute la toate nivelurile organizaiei, iar sprijinul i implicarea activ a managementului de la
cel mai nalt nivel sunt indispensabile pentru succesul implementrii i funcionrii unui SMM.
Reuita demersului de protecie a mediului necesit gsirea unor tehnici i instrumente
prin intermediul crora obiectivele i intele de mediu s poat fi atinse, concomitent cu o
corect previzionare legislativ i o mbuntire a relaiilor cu prile interesate
Reglementrile de mediu actuale incluznd legi, norme, regulamente, directive,
standarde, .a, sunt extrem de complexe i de o mare diversitate, de la o zon geografic la
alta, de la o ar la alta, de la o cultur la alta. Principala lor caracteristic i diferen n
183
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
raport cu reglementrile din alte domenii de interes social major este c ele nu au aprut ca
urmare a promovrii unor principii, ci ca o reacie la evenimente.
Odat cu mbogirea actualului cadru legislativ referitor la mediu, se constat o evoluie
de la simplu la complex, de la o reacie de aprare la una de prevenire. Aceast evoluie
ascunde, de fapt, drumul de la contientizare la sistematizare, de la luarea n considerare a
mediului, la managementul de mediu.
Standardul internaional SR EN ISO 14001:2005 stabilete cerine referitoare la un SMM.
Toate aceste cerine reprezint baza operaional a construirii unui sistem de management
de mediu, coerent i eficient.
-interviuri,
-msurtori, inspecii,
monitorizri,
-analiza nregistrrilor
Gril de evaluare
Identificarea
aspectelor de
mediu
Elaborarea Programul
analizei de mediu
Elaborare
Lista aspectelor de mediu i
a impacturilor asociate
(pe proces/amplasament)
Stabilirea apectelor
semnificative de
mediu
Actualizarea aspectelor de
mediu
Definirea obiectivelor
generale i specifice
de mediu
Elaborarea Programului
de management de
mediu
184
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Aspectele de mediu, care pot fi controlate i influenate de organizaie i care pot avea un
impact important asupra mediului, se regsesc sub denumirea de aspecte semnificative de
mediu.
Organizaiile care nu dispun nc de un SMM trebuie s porneasc n aceast direcie
prin efectuarea unei analize iniiale de mediu (AIM).
185
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
emisii n aer,
deversri n emisar,
gestionarea deeurilor,
poluarea solului,
incidente/accidente ecologice.
ntruct nu exist reguli stricte i nici criterii obligatorii pentru evaluarea impacturilor,
fiecare prestator de servicii de alimentare cu ap i canalizare i va stabili propriile sale
reguli i criterii de evaluarea impactului. Chiar unor criterii identice, organizaii diferite le pot
acorda grade diferite de importan.
Impactul asupra mediului al activitilor din organizaie este msurat i monitorizat, iar
eventualele neconformiti identificate trebuie tratate conform procedurii Aciuni corective i
preventive stabilit la nivelul organizaiei.
186
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
187
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
de
Impact
Evaluare impact (P)
accidental (max o data/an)
2
rar (1 - 12 ori/an)
4
foarte des, permanent (mai mult de 12 ori/an)
6
nu sunt reglementati prin prevederi legale
1
3
sunt reglementati prin indicatorii monitorizati nu depasesc
limitele maxim admise
prevederi legale
indicatorii monitorizati depasesc
6
limitele maxim admise
impactului asociat
b) Evaluarea nivelului de risc (Nr) pentru evaluare se iau n considerare urmtorii factori:
-
probabilitatea de apariie: cu ct aceasta este mai mare,cu att factorul de risc este
mai ridicat;
severitatea consecinelor: cu ct este mai mare vtmarea prin poluare, cu att este
mai ridicat nivelul de risc.
188
Severitatea consecinelor
(C)
f. ridicat 10 pct.
ridicat 8 pct.
moderat 6 pct.
sczut 4 pct.
f.sczut (nul) 2 pct.
Nivelul riscului
( A+B X C)
50 pct.
20 pct.
21 pct.
18 pct.
11 pct.
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
nesemnificative: 1 punct.
e). Probleme ale comunitii i mediului local (P) la stabilirea semnificaiei aspectelor de
mediu se vor lua n considerare i elemente referitoare la comunitate i mediul local,
acordndu-se un punctaj de la 0 la 60, aa cum se prezint n tabelul nr. 3.
Suma (1+2+3) reprezint problemele comunitii i mediului local.
Tabel 3: Probleme ale comunitii i mediului local
Zgomot
Aspect peisagistic
Reclamaii
Probleme ale
comunitii i
mediului local (P)
lips zgomot 0 pct.
Plcut 0 pct.
lips reclamaii - 0 pct.
0 pct.
n incinta societii necorespunztor n ale
vecinilor, 30 pct.
10 pct.
incinta societii beneficiarilor 10 pct.
10 pct.
pn la vecini 20 deranjant
pentru ale prilor interesate/ 60 pct.
pct.
vecini 20 pct.
organismelor de control
20 pct.
Toate aspectele de mediu care n urma evalurii impactului asupra mediului au peste 50
puncte sunt considerate aspecte semnificative de mediu.
4. Concluzii
Cele dou metode de identificare i evaluarea impactului asociat aspectelor de mediu pot fi
utilizate de ctre prestatorii serviciilor de alimentare cu ap i canalizare din localitile mici i
mijlocii n implementarea sistemului de management de mediu, cu scopul de a-i propune ca
efectele activitilor sale asupra mediului s fie n limitele legale i/ sau de reglementare, n
vigoare i s acioneze pentru diminuarea continu a acestora.
Prima metod poate fi utilizat la proiectarea i implementarea unui sistem de
management de mediu, pe cnd cea de-a doua metod este mai complex i poate fi
utilizat la mbuntirea performanelor de mediu.
Fiecare dintre aceste metode prezint avantaje i dezavantaje, are domenii n care este
mai eficient i domenii n care rezultatele aplicrii ei sunt mai puin relevante.
189
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
ntruct nu exist reguli stricte, nici criterii obligatorii pentru evaluarea impacturilor, fiecare
sistem de alimentare cu ap i canalizare i va stabili propriile sale reguli i criterii.
Bibliografie:
Moldovan, Daniela Simona (June, 2007) Cercetri privind sistemul de management intergat calitate mediu, Tez
de doctorat, Universitatea Transilvania din Braov.
Moldovan, Daniela Simona (June 1-3, 2005) The implementation and certification of the quality-environment
integrated management system to public services suppliers, Challenges in Higher Education & Research in
the 21 st Century, Sozopol, Bulgaria, vol.3, Heron Press, Sofia, pag.351-356.
ISO 14001 : 2004 Environment Management Systems. Guide book regarding the principles, systems and
application techniques.
ISO 14050 : 1998 Environment Management. Vocabulary.
190
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
A. S. Dobre *,
*Prof. Dr. Eng., Technical University of Civil Engineering Bucharest, tel/fax: +40-21-242-35-95,
E-mail: danca@utcb.ro
Abstract
Water specialists have been examining results from past national and around the world
efforts and applying experience learnt to create new approaches to solving difficulties in
getting efficient, effective water services to rural communities. As an important conclusion,
success is formulated by a mixture of investment, policy and institutional reform; capacity
building and learning that will vary with each country and even with each region within a
country.
Whether in developed or developing countries, we face the same or similar challenges in
managing small community water supplies. Cooperation on water small community water
system management might also serve as a catalyst for greater regional integration, both
economical and political, with benefits.
Main challenges related to the management of small community water supplies are
presented in the paper and also pertinent proposal to overcome them. Specific requirements
for programs that should be in place to manage small community water systems are detailed.
Most of the problems in these areas stem from limited budgets and the lack of financial
ability of many associations to staff and operate their systems properly.
Small water systems operated in the small communitiesthose with a population less than
10,000 are an important part of the quality of life in rural zones. In many cases, economic
opportunities in rural areas are also connected to the availability of water from these small
systems.
Small water systems serve a lower percentage of the total population, but usually they
comprise the majority of the water systems operating in a country.
Water system capacity is the ability to plan for, achieve, and maintain compliance with
applicable drinking water standards. For a system to have capacity, adequate capability in
three key areas technical, financial, and managerial is necessary (see Fig. 1). TFM
capability has been the buzzword from water system regulators for several years, yet almost
everyone agrees that it is a good policy and, in theory, benefits all water systems. However,
many small water systems still lack TFM capacity and do not understand the basic concept,
including short- and long-term planning.
Ongoing technical assistance and effective training are the keys to continuing and
improving TFM capacity.
191
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Small system needs for capacity may differ from those of larger systems, and policy
makers must be cognizant of these differences.
It is important to understand the need for capacity and the challenges the very small
systems face in operating and maintaining compliance with increasing standards.
Main challenges related to the management of small community water supplies are the
following:
Appropriate agents do not have the resources to control small community water
supplies
Poor decision making stemming from perception that there is no ownership and/or
awareness of the true cost of water
Lack of training for operators and managers of small community water supplies and
lack of expertise, necessary to ensure that systems are sustainable
Health surveillance
Framework for implementing WSP for small community water supplies. Public
awareness and participation in decision making is relative because public perceptions
and attitudes towards environmental issues have been conditioned by cultural,
traditional, socio-economic and political factors. It is also considerably changing in
time. Recent studies revealed marked differences in opinion between the public and
192
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Management of priorities
Information
Tools to ensure that decision makers at community, regional and national levels are
aware of their roles and responsibilities
Capacity development for water operators and managers, including incentives to stay
within the community
Activities to be undertaken that would have the greatest impact on improving the
management of small community water supplies:
o
Support training and education, such as through universities, colleges and ongoing liaison and support
Increase visibility
Information or tools on how to use The Water Safety Plan approach to identify
hazards and risks and prioritise improvements
Work on information and advocacy tools that would lay the groundwork for
change
193
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Increase access to supportive technology (the right tools for the job)
In order to achieve this target list, we consider that the minimum elements to be included
in drinking water system management plans are the following:
Group A
Well-defined responsibility
Operators manual/log book to identify what should be and has been done
Training
Group B
b.
c.
d.
b.
194
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Group C
Provide training and technical assistance to improve knowledge and skill competency
in technical, managerial, and/or financial capacity of drinking water system personnel
Communication of risk
Establish and develop resource centres (materials, information exchange, advice and
equipment)
Drinking water system management plans shall be correlated with the elements included
in general development plans for the entire zone referring to existing and anticipated
agricultural uses and appropriate best management practices assembled from one or more
of the following planning elements:
a. livestock management system
b. horticultural management system
c. site development plan (agricultural construction plan, for purposes of this rule)
d. agricultural drainage system
e. fish and wildlife system, and
f. dairy nutrient management plan
The plan may also include best management practices as those for installing field access
roads, livestock bridges, manure lagoons, livestock flood sanctuaries, covered manure
compost bins, etc.
Conclusions
Community driven development is an approach to development, not a model. The entry point
sequencing, and rules of the game established by the approach vary according to the nature
of the society in which work is taking place.
Using the community approach to reach the specific sector objectives requires a new
approach to development that is different from the exclusive involvement of government as
provider. Achieving sustainability and scale it in a community system requires actions from
the donors and organizations, otherwise it will not be sustainable.
The diagram - Application of water safety plan principles to small systems is shown
below.
195
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
References
*** Handbook for Small Water Systems, Asset Management, Performance Guide Series, 2003, EPA, USA 816-R03-016
*** Guidelines for the Preparation of Planning Documents for Developing Community Water System Projects,
Department of Agriculture, USA, 2004
*** Training and Technical Assistance for Small and/or Rural Public Water Systems, EPA, USA, 2002
Environmental Engineering Elements, Dobre, A., Ed Conspress, Bucuresti, 2003
196
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Conf. Dr. Ing. Dorin Staicu, Drd. Ing. Savoiu Sorin, Ing. Gradinaru Sebastian
OBIECTIVE:
Alegerea solutiilor si a schemelor de proiecatare, automatizare (actionare, comanda si
contrlol) si de monitorizare a sistemelor de alimentare cu apa a localitatilor trebuie sa tina
cont de urmatoarele exigente:
-
2.
3.
197
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
4.
5.
Controlul debitelor de apa la utilizatori si a presiunilor din retea prin metoda reglajului
pentru consumatorul cel mai defavorizat.
6.
7.
Analizarea posibilitatii de creare a unui sistem informatic integrat tip EXPERT pentru gestiunea resurselor si controlul functionarii echipamentelor.
8.
9.
198
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Caracteristica
instalatiei
H(Q)=Hg+KQ2
Economia energiei de pompare, conform fig 1 este ilustrata de aria delimitata de curbele
V1-Hg, Hg-Hmax si Hmax-f1, fiind definita de urmatoarea formula:
Eh = g(Hmax x Qmax)
Q max
( Hg + kQ 2 )dQ
Dupa cum se observa din inregistrarile experimentale (fig. 2), utilizind metoda conform
inventiei, se obtine o reducere a consumului specific de energia de pompare de 20-25%, fata
de reglarea turatiei cu mentinerea constanta a presiunii de refulare (H= Hmax = ct.)
In fig.2 se prezinta o diagrama inregistrata pe o perioada similara de 24 de ore cu cele
doua metode.
199
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Kw/mc
2c
Figura 3
200
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
anumita perioada de timp, ci mentinerea unei presiuni constante la consumatorul cel mai
defavorizat.Acest sistem are trei avantaje de foarte mare importanta, si anume:
reduce pierderile de apa, deoarece cantitatea de apa pierduta prin sparturi depinde
de presiune.
201
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
1. Basic concepts
This document addresses some issues that are frequent in building hydraulic models from a
GIS database. Although old modeling software relied exclusively on text file input and output,
while modern modeling software use a graphical user interface for easier model construction
and visualization of the results, they are all based on the database concept. Despite the fact
that there are more or less subtle differences between the content and structure of the GIS
database and the hydraulic model database, creating both of them has in time proved to be
an expensive, time consuming and most important - a duplicate effort. The main problem is
that GIS focuses on details, while hydraulic modeling tends to makes things as simple as
possible for its purpose. The conversion between a GIS model and the corresponding
hydraulic model is a process that requires full understanding of both GIS and hydraulic
concepts. This document focuses on NetSET (GIS platform) and RET (hydraulic modeling
software).
The concept of hydraulic modeling allows for many new approaches concerning the
behavior of a water supply network. Often the big challenge is to build this hydraulic model
from inconsistent or chaotic data. GIS software has the advantage of collecting and
validating all the available information, thus providing the hydraulic modeler with a coherent
set of data. However, much information that exists in current GIS databases is not required
or is not compatible with the specifications of hydraulic modeling software.
Solving this task is part of a CEEX project (GISHIDRO) that teamed-up Technical
University of Civil Engineering of Bucharest and Data Invest, amongst others. Both partners
provided a software solution; one for GIS (NetSET from Data Invest) and the other for
hydraulic modeling (RET from UTCB Hydraulics Department).
When designing a water supply system for a small locality is like thinking on a smaller
scale. However, the complexity of such system should not be overlooked. The problem is to
make and keep things very simple. Often it involves establishing water sources that can
supply several localities.
Pipes
A pipe represents a portion of a conduit with non-zero length, with a constant diameter,
delimited by two nodes with no consumption between them. A pipe may have regulating
202
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
valves and/or fixed hydraulic resistances. Apart from this, there is also the concept of virtual
pipe with zero length that is used for placing booster stations and pressure breaks. In case of
pipes with uniformly distributed demands, the sum of the demands is moved evenly in the
two nodes that define the pipes. Briefly, a pipe is identified by its characteristics: length,
diameter, roughness, minor losses coefficient and of course, flow rate and velocity.
According to the sign rule, the flow rate Q is positive when the fluid flows from the node with
a lower index to the node with the greater index.
Nodes
A node is any vertex in the network graph. In the network, the node represents the
connection point for more pipes. It can be an end-node for a tree-like pipe, but also a
separating node on a pipe for obtaining lengths within the range imposed by the model. From
a topological point of view, the node unifies the pipes and defines theirs spread and
connections. At the same time represents the point where the liquids enter and exit the
network. Also it can be used to connect another network or specific equipment. The node is
defined by several parameters, including the X and Y coordinates, elevation, necessary
service pressure, base demand and of course the calculated pressure. In order to facilitate
the modeling of various situations existing in a real water distribution network, the RET model
contains several type of nodes.
HN(K)
Z3
hr
A reservoir is directly attached at a node from the network. It supplies the network but at the
same time it can be supplied by the network, operating at fixed head and variable exchange
flow rate with the network. Reservoirs from the water networks where the temporarily
operating sequences must be optimized are an exception from this rule (these are reservoirs
that have both the height and the flow rate variables).
203
ZN
Z5
hrb
PN
HP
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
k10
k1
k11
Z3
QR
k2
k14
k12
RLA = 0
k1
a)
k2
b)
Figure 3 Node with pressure break tank
This tank can be real or, very often, is simulating the function of a control valve. These
are used for reducing the pressures in certain areas of the network. The tank is allocated at
the exit node K2.
For these tanks, a correct solution should meet the following two demands:
204
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
The hydraulic grade HN(K1) should be greater than the fixed set geodetic height
Z3(nd) for tank water level
If the first condition is not met, the tank will appear as supplied by the network trough
node K2 and the water will be accumulated in the reservoir. This may indicate that the
reservoir is useless. If the only the second condition is not met, this will indicate a
malfunction.
Regarding the pipes, in order to ensure a better precision for optimization calculations, for
drawing the supply zones and for continuing with the transient flow calculations, it is
recommended that the pipes should have a length of the same order. In order to obtain this,
the long pipes will be divided by additional nodes and the short pipes will be merged in the
adjacent nodes.
If the pipes are correctly described and the exact coordinates are given, RET can
automatically compute their length.
205
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
The nodes represent a more complicated problem, because there are several types.
Except from XX and XY fields, all other values are mandatory for the hydraulic model.
The XX/XY are used for drawing the network with RET (but this feature is obsolete now that
this task is handled by the GIS interface) and optionally for computing the lengths of pipes,
so they are not mandatory.
For the other node types, additional information must be provided. Typically, a water
network GIS database will not contain this information. In this case, the user must check if
this is the case and will have to decide if he can afford to ignore them or if he must update
his database.
206
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
5. Conclusions
GIS is becoming an increasingly valuable tool for the water distribution modeller both as a
source for modelling data and as a decision-support tool, but we cant talk about using a GIS
database for a hydraulic model as long as the above conditions are not respected by the
developers and as a result, the problems often faced by modellers using GIS data include
the following:
207
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
References
D. Cioc, A. Anton, Retele hidraulice calcul, optimizare, sigutanta, Ed. Orizonturi Universitare, Timisoara, 2001
C. Iamandi, V. Petrescu, L. Sandu, R. Damian, A. Anton Hidraulica Instalatiilor vol. II,Editura Tehnica, Bucuresti,
2002
D. Cioc, E. Trofin, C. Iamandi et al, Hidraulica culegere de probleme, Editura Didactica si Pedagocica,
Bucuresti, 1973
ESRI, Building a Geodatabase, USA, 2002
Data Invest, Manual de Utilizare NetSET HYDRO, unpublised
B. Dimitriu, A.Aldea,Monitorizarea presiunii si a debitului in retelele de distributie, Conferinta Internationala ARA
editia a V-a, Brasov, Mai 2003
HAESTAD METHODS, Advanced water distribution modeling and management
Paul Ginther, Use of GIS Growing in the Municipal Water, Wastewater Business
Werner de Schaetzen and Paul F. Boulos, Optimal Water Distribution System Management Using ESRI
MapObjects Technology
208
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
1. Introduction
In literature on economic organisations there pertains to be two leading approaches to
efficiency as business strategy. These approaches have developed much in the last 15
years and offer a general framework that provoke insights into the economic organisation.
One of the basic tenants of these theories is the assumption that organisations are
constructed from different resource bundles and capabilities, underlying production which are
heterogeneous across firms. These resource bundles can be described as productive factors
that have intrinsically differential levels of efficiency.
This paper suggests that it is the differential in resource bundles that lead to differential
operating efficiencies. In theory then this should lead the economising manger directly to the
source of such inefficiency. However, due to complexities in operating large water and waste
water operating companies there exists a degree of causal ambiguity around which
resources are of a superior or marginal nature. The key to unlocking efficiency improvement
potential lies in understanding the scope of improvement for each resource bundle. Whilst it
is impractical to conduct a full analysis on the scope for improvement for all assets in this
paper, a journey is embarked upon that takes the reader from a high level, top down view of
industry costs and efficiency finishing with analysis at the level of a specific site and cost
allocation.
Included within this paper is a case study based upon the waste water element of a water
and waste water company in the UK. The Company delivers water to and treats the waste
water of circa 3m customers using a number of process plants with population equivalents
ranging between 900,000 and less than 250. These process plants operate in both urban
and rural environments and over a wide geographical area.
209
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
varies. It is concluded through analysis of data from the case study that this is due to the
existence of heterogeneous resources across the sector resulting in efficiency variation.
Pressure from the city and regulators often lead to a top down price setting agenda which
result in generic efficiency targets that are not informed by efficiency potential. The presence
of causal ambiguity often obfuscates options for potential efficiency from managers keen to
pursue a first order economising agenda. These two factors combined can lead to suboptimal efficiency drives that fail to deliver the full potential for improvement.
The second part of this paper suggests that the key to realising this scope, and delivering
an effective economising strategy lies in understanding what the key determinants to
efficiency are and what their scope for improvement is. Several determinants of efficiency
are either outside the control of the economising manager such as fluctuating costs of key
operating inputs (i.e. such as power or increasing consent levels from key environmental
stakeholders), or are heterogeneous in nature and are not transferable. Much economising
effort has been wasted in attempt to influence the un-influenceable. This section seeks to
give practical guidance, based upon experience gained through recent work within the water
industry and focuses upon 3 areas, Supply Chain management, Performance Improvement
and Effective Delivery Strategies (Lean engineering).
The third section looks to support the economising manager by proposing practical
methods of achieving real terms efficiency improvement through a case study looking at
actual delivery of improvement. These focus on delivering efficiency through the key
determinants of efficiency discussed in the second section.
3500
3400
3300
3200
3100
3000
2900
2800
2700
2600
19
89
19
90
19
91
19
92
19
93
19
94
19
95
19
96
19
97
19
98
19
99
20
00
20
01
20
02
20
03
20
04
20
05
20
06
's Million
210
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
In the last year (2005/6) costs increased by 151m, this is partly due to a change in
accounting around leakage spend. 67m of the increase is due to rising energy prices
across the industry. Figures 2 & 3 break this number into the different operating companies
looking at the unit costs of production for Water and Waste Water. The UK water industry is
divided into Water and Waste water companies, of which there are 10 and 15 clean water
only companies (making a total of 25 Clean Water Companies) resulting in a reduced
number of data sets in the waste water chart.
Cost of operations
Dwr Cymru
Folkestone &
Dover
Tendring
Hundred
Industry
Average
Wessex
United
Utilities
South West
Anglian
Capital Maintenance
South East
Severn Trent
Bristol
Yorkshire
Thames
Sutton &
East Surrey
Mid Kent
Dee Valley
Northumbrian
Cambridge
Three
Valleys
Southern
160
140
120
100
80
60
40
20
0
Portsmouth
Bournmouth
&W
South
Stafordshire
's per m3
Return on Capital
's per M3
200
150
100
50
Cost of operations
Capital Maintenance
Av
er
ag
e
W
es
t
W
ei
gh
te
d
So
ut
h
An
gl
ia
n
til
iti
es
U
U
ni
te
d
So
ut
he
rn
rC
ym
ru
D
w
W
es
se
x
or
th
um
br
ia
n
sh
i re
Yo
rk
Tr
en
t
Se
ve
rn
Th
am
es
Return on Capital
It is clear from the figures above that there is variation in the unit cost of delivery across
the water and waste water operating companies. However, for both water and waste water
there is a central tendency around the mean, with the exception of a couple of outlying
organisations. The variation in unit costs across the operating companies is a useful
comparison of efficiency across the industry. Our experience suggests that due to the high
level (top down) nature of the data, it should not be solely relied upon to provide a true view
of efficiency. One of the reasons for this is that such analysis fails to pick up on idiosyncratic
issues associated with particular companies. It also fails to identify causal factors which are
outside of the control of operating companies, such as the price rise in energy costs suffered
211
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
by the whole industry. Of the two outliers in figure 2 it has been reported that Tendring
Hundred has a large capital base as a result of work undertaken to improve water quality. It
also has a lower customer demand, which has had a negative effect upon the figures. South
West has a disproportionately high return on capital figure as a result of its quality
programme impacting on its performance. However South Wests clean water treatment
costs also tend towards the more expensive, suggesting the presence of marginal resources
leading to underlying inefficiency.
More meaningful analysis on the quality of resources requires greater levels of data
granularity. This is possible if the focus of analysis is narrowed. Figure 3 looks at the cost of
treatment for large (band 6) waste water treatment companies across the UK. The analysis
looks at the cost of treatment by population equivalent (pe) and splits costs into various
different operational cost buckets. In this figure Power means Power used in the treatment
of waste. Other Direct Costs are the direct costs involved in treatment of waste excluding
power (i.e. maintenance, labour, chemicals etc). General and support costs equate to head
office costs for the site, service charges are the total services charged (e.g. by the
Environment Agency).
Average
Scottish Water
Yorkshire
Wessex
United Utilities
Thames
Southern
South West
Severn Trent
North-umbrian
Dwr Cymru
Anglian
0.00
2.00
Power costs
4.00
Other Direct Costs
6.00
8.00
10.00
12.00
Service Charges
Prices range from Scottish water at 3.70 /pe to South West Water at 11.48 /pe. This
could be suggestive of the presence of superior resources on the part of Scottish Water.
Power makes up circa 26% of operating costs, however, from the data it is clear that Dwr
Cymrus power costs are closer to 50% of their total operating costs. Figure 4 is
representative of an aggregation of costs from a number [400+] large works and allows us to
draw some conclusions on the scope for efficiency within the waste treatment companies.
This analysis indicates that there is some potential scope for efficiency improvement in a
number of operating companies. To get a better understanding of efficiency, a more bottom
up approach is required. This is commenced in figure 5, which shows the distribution of
operational treatment costs for a particular treatment type (i.e. Secondary Activated Sludge);
this is the most frequently occurring treatment type in the dataset. To avoid bias arising from
different operating establishments all non direct operational costs have been removed from
this data.
212
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Frequency of Occurance
14
12
10
8
6
4
2
Upper Quartile
Median
13
12
12
.5
11
11
.5
10
10
.5
9.
5
8.
5
7.
5
6.
5
5.
5
4.
5
3.
5
2.
5
1.
5
0.
5
's PE
In this population the mean is 3.99/ pe. However, there is a clear skew to the
distribution of results, the median (3.39/ pe) is more indicative of the average cost of
treatment. In figure 5 the median is highlighted by the green data point, upper quartile
performance is indicated by the pink data point. If we take these figures and use them to
compare the performance of a water companies SAS treatment plants, it is possible to arrive
at some conclusions around the scope for efficiency improvement. The data used in the
following analysis has been gathered from field work, for this reason it has been made
anonymous. It does have the benefit of providing further breakdown of the costs of treatment
by site into 6 main operating costs.
's/pe
7.00
Maintenance
6.00
BIS
5.00
Power
4.00
Chemicals
3.00
Labour
2.00
1.00
ed
ia
n
M
Up
G
pe
rQ
ua
rti
le
It is clear from the histogram that of the 7 SAS sites in company A only 1 achieves upper
quartile performance and 3 works are able to treat waste at below median cost. It shows
213
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
clearly that power efficiency is a principal determinate in the efficiency of a SAS treatment
works. From this analysis it is reasonable to suggest that sites A & C are of a superior
nature and contribute towards the efficiency of the firm. It is also evident that sites E & F are
of a marginal nature and are detrimental to the firms cost efficiency. A manager pursuing an
agenda of first order economising would be well advised to target their efforts towards
improving the marginal nature of these resources.
Such a manager may well pursue such an efficiency agenda due to pressure from the city
and regulators. These often lead to a top down price setting agenda which result in generic
efficiency targets that are not informed by efficiency potential. In figures 1-5 above, it has
been demonstrated that it is possible to identify and isolate both superior and marginal
resources. This allows for a more targeted approach to efficiency improvement to be taken.
The figures also demonstrate the existence of scope for efficiency improvement across much
of the industry. It is clear that the realisation of these improvements is within the
expectations of the UK Water Regulator who set prices in accordance with these
expectations.
The next part of this paper suggests that the key to realising this scope, and delivering an
effective economising strategy lies in understanding what the key determinants to efficiency
are and what their scope for improvement is.
214
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
215
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
treatment/ disposal costs. The following examples are indicative of work undertaken to
improve the efficiency performance of the Client.
Power
BIS
Labour
Chemicals
Maintenance
Carbon
Industry
Average
Average
Other
Sitting behind this is analysis containing unit cost data sets that allow for individual
process steps to be compared across populations of treatment works. The average for the
industry is dictated by the grey data point, it was clear from the analysis that moving all sites
to average or upper quartile performance would deliver significant improvement to the
operating costs of the case study organisation. The solution was divided into two parts,
Supply Chain Management and Effective Delivery Strategies.
216
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
for a category management approach to be commenced and the supply chain to be broken
up into manageable groups, allowing for effective category management. Category
management plans were then drawn around each of the categories.
The Benefits:
Joint working with the Client and partners delivered a comprehensive review of the
supply chain that was endorsed by all parties
Category management has ensured that each of the key categories are governed in a
systematic way meeting key client objectives
Joint working teams between change practitioners and operators have delivered a
joined up approach towards efficiency
Work is ongoing to ensure that the delivery of projects is done in a robust and
sustainable way
217
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
5. Conclusion
The experience of EC Harris in the UK water industry suggests that benchmarking is a
practical method of identifying the potential scope for efficiency improvements within water
industry. Once sub-optimal performance has been identified then targeted improvements
can be delivered. EC Harris experience suggests that these tend to fall into one of three
categories, Performance Improvement, Supply Chain management, and Effective Delivery
Strategies. This is equally relevant to large or small process works, and on above and below
ground assets. This knowledge is readily transferable across international boundaries, and
will allow the operating companies in the Romanian water industry to benchmark their
performance against each other, and against international datasets. This can lead to the
efficient and effective delivery of efficiency improvements.
References
-------- (2006): Water and Sewerage Service Unit Costs and relative efficiency: 2005-2006 report, Birmingham,
Office of Water Services
-------- (2003): Office of Water and Sewerage Services. The Scope for Efficiency Improvement in the Water and
Sewerage Industries: London, Europe Economics
Drew, J., McCallum, B., Roggenhofer, S. (2004) Journey to Lean, London, Palgrave Macmillan press
Peteraf, M. (1993) The Cornerstones of competitive advantage: A resource based view Strategic Management
Journal, 14, 179-188.
Williamson, O. (1996) The Mechanisms of Governance, Oxford, Oxford University Press, 307-321
218
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
1. Introducere
Principiile si valorile de baza privind sectorul apei n mediul rural din Romnia sunt
ncorporate n urmtoarea declaraie acceptata de autoritile centrale la sfarsitul Proiectului
de Dezvoltare Rurala, finanat de Banca Mondiala:
Viziunea sectorului apei din mediul rural din Romnia consta n furnizarea eficienta a
serviciilor de alimentare cu apa, colectare si epurare a apelor uzate n mediul rural din
Romnia, ntrunirea cerintelor privind sanatatea populatiei, protectia mediului si ale
utilizatorilor printr-o maniera durabila si la un nivel acceptabil al capacitatii de plata a
utilizatorilor.
Considernd Viziunea ca tinta a acestui sector, Misiunea este urmatoarea:
Sectorul va furniza echiparea tehnico-edilitar si infrastructura ntr-o maniera planificata
si economica, ca raspuns la cererea de servicii a utilizatorilor, folosind tehnologia adecvata si
cele mai bune practici n management, proiectare si operare pentru a asigura servicii
complete si sigure, conforme cu reglementarile n vigoare.
In alti termeni situaia dorit poate fi enunat asfel - Atingerea Obiectivului nr.7 de
Dezvoltare a Mileniului, inta 19: Dublarea, pn n 2015, a procentului persoanelor care au
acces durabil la surse sigure de ap i la servicii de igienizare de baz.
Propunerile pe care le facem in acest scop vizeaz:
-
aspectele de mediu;
219
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
2. Consideraii generale
Guvernul Romniei considera investitiile pentru furnizarea de servicii sigure de alimentare cu
apa si canalizare, la un pret pe care utilizatorii sa si-l poata permite, ca fiind eseniale pentru
cetenii din mediul rural.
Datorita insuficientei fondurilor n perioada anterioara, lipsei capacitatii si coordonarii si
cooperarii ineficiente ntre ministere, de-a lungul timpului, guvernele Romniei nu au fost
capabile sa asigure servicii corespunzatoare si durabile de alimentare cu apa, colectare si
epurare a apelor uzate, pentru majoritatea populatiei din mediul rural.
Ritmul actual de extindere, sprijinit financiar de la Uniunea Europeana si Banca Mondiala,
este insuficient pentru a atinge obiectivele pentru acest sector.
Pentru ndeplinirea sarcinilor asumate, inclusiv atingerea Obiectivelor Mileniului pentru
Dezvoltare si a angajamentelor asumate n Tratatul de aderare, Guvernul a introdus o serie
de initiative pentru a accelera rata de crestere a ariei de acoperire a serviciilor comunitare de
utilitati publice.
Provocarea cu care se confrunta Guvernul Romniei este aceea de a accelera procesul
de crestere a ariei de acoperire a utilitatilor publice de alimentare cu apa, colectare si
epurare a apelor uzate n mediul rural, si n acest scop considera elaborarea unei Strategii
pentru sectorul Sistemelor Rurale de Alimentare cu Apa si Igienizare (SRAAI) ca fiind
esentiala. Principalul obiectiv al Strategiei va fi acela de a mbunatati conditiile de viata si
starea de sanatate a populatiei Romniei si de a sprijini dezvoltarea economica a zonelor
rurale. Acest lucru poate fi obtinut prin cresterea accesului populatiei la surse sigure de
alimentare cu apa pentru 85% din totalul populatiei pna la sfrsitul anului 2020 si prin
asigurarea unui sistem de colectare a apelor uzate pentru 80% din populatie pna la sfrsitul
anului 2015.
3. Solutii si recomandari
3.1. Organizarea instituional
n prezent mai multe ministere gestioneaz programe privind alimentarea cu ap,
canalizarea i tratarea apei uzate: Ministerul Mediului i Dezvoltrii Durabile, Ministerul
Dezvoltrii, Lucrrilor Publice i Locuinei, Ministerul Agriculturii i Dezvoltrii Rurale,
Ministerul Internelor i Reformei Administrative, Cancelaria Primului Ministru. Toate aceste
programe ar trebui s contribuie la implementarea unei politici consistente n domeniu i ar
trebui coordonate.
La nivelul operatorilor regionali este necesar s fie constituite echipe de asistenta care
s poat acorda asisten unittilor administrativ teritoriale cu o populaie sub 10.000 s
iniieze si sa implementeze proiectele de investiii, iar apoi s verifce delegarea operrii
acestora ctre operatorul regional.
220
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
221
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
222
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Apa nu va fi furnizata fara plata unor tarife. Principiul de facturare al operatorilor trebuie
sa se bazeze pe volumul de apa consumat. Facturarea se va face lunar pentru a evita
acumularea de datorii din partea utilizatorilor si pentru a mbunatati fluxul de numerar al
serviciilor de utilitati. Se va asigura colectarea corespunztoare a tarifului i managementul
financiar al serviciului. Serviciul de apa nu trebuie sa fie vzut ca un serviciu de protectie
sociala. Lucrurile ar trebui clar separate: populaia plteste serviciul iar autoritatea locala va
asigura, daca este cazul, protecia social prin acordarea unui ajutor pentru a asigura plata
unui volum minim de ap.
223
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
4. Concluzii
Leciile din trecut au aratat necesitatea unei abordari integrate din partea autoritatilor, dar si a
operatorilor de specialitate, pentru a asigura:
a. Coordonarea investitiilor n sectorul apei din mediul rural pentru a sustine utilizarea
rationala a resurselor de apa i protectia mediului;
b. Planificare cuprinzatoare a resurselor financiare n sectorul apei din mediul rural, cu
scopul de a oferi o abordare globala n ceea ce priveste serviciile comunitare de
utilitate publica de alimentare cu apa si de canalizare si epurare a apelor uzate;
c. Stabilirea unor tarife realiste care sa finanteze cadrul institutional necesar si sa
acopere costurile de operare, dar n acelasi timp sa fie suportabile pentru utilizatori.
Trebuie fcut observaia c, dei sunt mici, lucrrile sunt uneori foarte dificil de realizat,
datorit condiiilor geografice specifice. Din acest motiv, chiar dac este vorba de contracte
cu valori relativ mici, ele trebuie abordate cu maximum de seriozitate, uneori fiind mai dficile
dect o lucrare mare.
In elaborarea Strategiei integrate privind alimentarea cu apa i igienizarea n mediul rural
i n localitile urbane cu o populaie sub 10.000 locuitori va trebui sa se tina cont de
urmtoarele aspecte:
224
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Abstract:
Alike other fields, also in the case of water supply and sewerage system for communities up
to 10000 inhabitants, the engineering must solve, through optimal solutions, the
interconditioning between the installations/equipments efficiency and treatment process
respectively waste water treatment, on one hand, and the level of environment quality on the
other hand. It is obviously the such a desideratum rise the question of personnel training and
perfecting and the existence of a very professional documentation for quality-environment
management integrated system that provides solutions for identification of possible
improvement in this field. Moreover, the last years experience proves that the implementation
of a coherent and efficient quality-environment management integrated system become a
priority for water supply and sewerage public service.
1. Introducere
n ultimul timp preocuparea pentru sistemele de management integrat calitate-mediu a
devenit o prioritate pentru tot mai multe organizaii din Romnia, att din domeniul produciei
ct i din sfera serviciilor sau a instituiilor publice.
Companiile prestatoare de servicii publice de alimentare cu ap i canalizare, sub
presiunea diverselor motoare externe gen globalizare, integreaz deja principiile mbuntirii
continue, orientarea spre proces i alinierea ctre satisfacia consumatorul i mediului la
nivel de obiective i n momentul analizei pe obiective.
Relevana sistemelor de management integrat este reflectat de faptul c un numr n
cretere de companii implementeaz sisteme speciale de management pentru calitate i
mediu, n acelai timp.
Discuia ntre experi i activitile n multe companii indic faptul c sistemele integrate
de management sunt vzute astzi precum concepte organizaionale i de management
orientate ctre viitor. n practic, totui, sistemele de management separate sunt
predominante, situaie datorat n principal faptului c ele au fost iniiate pe baza
standardelor speciale sau se bazeaz pe acestea.
Totui, recent, au aprut o serie de semne chiar i n practic de regndire a
proceselor, cum ar fi: numrul crescut de sisteme de management implementate ntr-o
companie, problemele generate de implementarea n paralel a mai multor sisteme de
225
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
management separate i chiar discuiile tot mai aprinse privind sistemele integrate de
management.
PROCEDUR
(Mod specificat de desfurare
a unei activiti sau a unui proces)
Intrare
(Include
PROCES
EFICACITATE
a procesului =
abilitatea de a obine
rezultatele dorite
Ieire
(ansamblu de activiti
corelate sau n interaciune)
PRODUS/SERVICIU
Resurse)
EFICIEN
a procesului =
rezultatele obinute vs.
rezultatele planificate
MONITORIZARE
I MSURARE
(nainte, n timpul i dup proces)
226
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
CU CINE?
(personal: competene,
calificri, instruire)
CU CE?
(materiale,
echipamente)
Elemente de intrare
PROCESUL
CT?
(msurri,
evaluri)
Elemente de ieire
CUM?
(metode,
proceduri, tehnici)
227
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
PLAN
- identificare
procesului
- stabilirea
proprietarului
de proces;
- stabilirea
obiectivului
procesului
Elemente
de intrare
DO
implementea
z procesele
astfel nct
s se asigure
atingerea
obiectivelor/
indicatorilor
de
performan
ACT
- acioneaz
pentru
mbuntire
a continu a
performanei
procesului
de
ntreinere i
reparaii
reele
NU
OK?
DA
Elemente
de ieire
CHECK
- msoar i
monitorizeaz
procesul de
ntreinere i
reparaii reele
prin raportare
la indicatorii
de
performan
Figura 3. Procesul de ntreinere i reparaii reele de transport i distribuie ap potabil, n abordarea ciclului
PDCA
228
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
1. Date generale:
Proprietarul procesului
Proces furnizor
Proces beneficiar
Procesul
Resurse umane
Resurse documentare
Resurse materiale
3. Planificarea procesului
Scopul
procesului
Meninerea
instalatiilor si
echipamentelor
hidraulice n
parametrii
funcionali fr
ntreruperi
Obiective specifice
1. Obiectiv al calitii
Respectarea timpului maxim
dintre sesizarea unei avarii,
restabilirea serviciului si
revenirea la starea normala, in
activitatea de transport i
distribuia apei
2. Obiectiv de mediu
Respectarea masurilor si a
termenelor stabilite prin
Programe de Conformare
229
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
4. Secvenele procesului:
Intrri
Registrul de sesizri i
intervenii, cod R-.....
Fia de intervenie,
cod F-.....
Instruciune de lucru
Subprocese/ Activiti
7.1. ntreinere i reparaii reele
7.1.1. Planificare zilnic a
interveniei:
- planificare execuie,
- planificare utilaje,
- planificare materiale,
- planificare formaie de lucru,
- obinerea autorizaiei de
intervenie n domeniul public
7.1.2. Deplasare n zona de lucru
i pregtirea pentru executarea
interveniei:
- manevre de nchidere golire
reea;
- completare materiale i utilaje
funcie de necesitile lucrrii.
7.1.3. Executare intervenie:
spturi i reparaie
Ieiri
Fia de intervenie, cod
F-.....
Aviz de intervenie
tipizat
Fia de intervenie,
cod F-.....
Fia de intervenie,
cod F-.....
Fia de intervenie,
cod F-.....
Fia de intervenie,
cod F-.....
Instruciune de lucru
Fia de intervenie,
cod F-.....
Fia de intervenie,
cod F-.....
Fia de intervenie,
cod F-.....
Planificare zilnic;
Aviz intervenie;
Instruciune de lucru
Fia de intervenie,
cod F-.....
Registru refacere
imbracaminte asfaltica
Fia de intervenie
Fia de intervenie
Reclamaii scrise
Registre de sesizriintervenii
Rspuns n scris, (dup
caz), suport hrtie;
Registru de
coresponden
Rspuns n scris pentru
reclamaiile scrise;
Fia de tratare a
reclamaiilor
Situaia reclamaiilor
Fia de intervenii, cod F....
230
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Interaciuni
Cu procesul de captare,
tratare, transport i
nmagazinare ap potabil
Cu procesul de distribuie ap
potabil
Cu procesul de intervenii n
reeaua de ap-canal
Cu procesul de aprovizionare
Registrele de sesizri i
intervenii
Materiale aprovizionate
Rezultat buletin de analiz
Date de intrare conform
documentaiei SMCM
Documente
Cu procesul de monitorizarea
calitii apei potabile din
reeaua de distribuie
Cu procesul de comunicare
Cu procesul de controlul
documentelor
Cu procesul de controlul
nregistrrilor
Cu procesul de controlul
produsului/serviciului
neconform
RNAc/Ap
Plan de AI ; Chestionar de
AI ; Raport de AI ;
RNAc/Ap
Personal competent
conform fiei post; PV de
instruire;
Diplome, certificate, teste.
Note interne, adrese,
legislaie, Fie de
aptitudini
Ieiri
Planificarea interveniei
Manevre oprire-deschidere
reea
Comunicare perioad de
oprire
Registrele de sesizri i
intervenii completate
Referat de necesitate,
Necesar de achiziii,
Bon de consum.
Solicitare efectuare analiz
Date de ieire conform
documentaiei SMCM
Informaii i date privind
modificarea, difuzarea i
arhivarea documentelor
nregistrri
Corecie + Ac
Corecie + Ac + mbuntire
Cu procesul de aciuni
corective/aciuni preventive
Cu procesul de alocarea i
meninerea competenei
resurselor umane
Ac/Ap
Necesar de instruire,
pontaje, note de concediu
Cu procesul de asigurarea
securitii i sntii n munc
6. Monitorizare i msurare:
Metoda / Criteriu
Planificare
Criterii de acceptare
Program anual de
audit intern
Constatarea
conformitii cu criteriile
de audit
6.2. Monitorizare,
msurare n
proces
Planificarea
interveniilor
Constatarea
conformitii privind
intervenia efectuat
231
nregistrri
Notificare de AI;
Chestionar de AI;
Raport de AI;
RNAc/Ap.
Fia de intervenie,
cod F-.
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
4. Concluzii
Beneficiile abordrii procesuale ntr-un sistem de management integrat calitate-mediu sunt n
principal, pentru formularea policitii n domeniul calitate-mediu i strategiei: utilizarea
proceselor definite n ntreaga organizaie duce la obinerea unor rezultate previzibile,
utilizarea mai eficient a resurselor, scurtarea duratei de execuie a procesului i costuri
sczute.
Prin abordarea procesului de ntreinere i reparaii reele de transport i distribuie ap
potabil ntr-un sistem de management integrat calitate-mediu se asigur controlul
permanent asupra procesului i asupra interdependenei n cadrul sistemului, se confer
cadru unitar bine structurat pentru gestionarea problemelor de mediu (monitorizare aspecte
de mediu, gestionare deeuri) i se asigur capabilitatea de a furniza n mod constant
serviciu de calitate corespunztoare cerinelor clienilor i legislaiei n vigoare.
Pentru managementul funcional, abordare procesului de ntreinere i reparaii reele de
transport i distribuie ap n ciclul mbuntirii continue duce la obinerea unor rezultate
previzibile, utilizarea mai eficient a resurselor, scderea costurilor, prevenirea erorilor i
obinerea de rezultate prezivibile.
Bibliografie:
Pischon, A. (1999), Integrierte Management systeme fr Qualitt, Umweltschutz und Arbeitswissenschaft, Berlin,
Springer.
Moldovan, Daniela Simona (June, 2007) Cercetri privind sistemul de management intergat calitate mediu, Tez
de doctorat, Universitatea Transilvania din Braov.
The advantages of process approach in the quality management system within the companies that provide public
water supply and sewerage services, COPH OA OT PBA OHEPEH C
MEHAPOHO ACTE, MAHO3HAHE MAHH EEMEHT, 4-6 Hoombp, Sofia
Bulgaria, pag. 226-236
Moldovan, Daniela Simona (15th 17th june 2005) Monitoring of quality-environment integrated management
system processes to Compania Apa Brasov, Inovations in the Field of Watwr Supply, Sanitation and Water
Quality Management, Conference for young professionals Bucharest, Bucharest, Romania, pag. 477-483.
ISO 9001 : 2000 Quality management systems. Requirements.
ISO 14001 : 2004 Environment Management Systems. Guide book regarding the principles, systems and
application techniques.
232
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Abstract
The riparian zone is an exceedingly important transitional land between lake, river, stream, or
wetland and upland ecosystems, such as forests. The riparian zone provides shelter and
home to many animals, birds, insects, and plant species. It also provides a buffer zone for
lakes and streams by absorbing excess water run-off, breaking down pollutants, and holding
sediments. With a well-functioning riparian zone, water quality is maintained and the aquatic
systems are able to support life and life cycles, such as spawning fish.The riparian zone is so
essential to a healthy ecosystem that forestry practice requires that this area be
protected.Although riparian areas may occupy only a small percentage of the area of a
watershed, they represent an extremely important component of the overall landscape.
Ecosisteme ripariene
Programele de conservare a naturii trebuie sa ia in considerare politicile de dezvoltare rurala,
strategiile agricole si forestiere, precum si numeroase alte interese socio-economice.
Deciziile ar trebui sa fie luate printr-un dialog real intre autoritatile guvernamentale si
societatea civila, autoritati care ar trebui sa manifeste o deschidere dublata de cunostinte
stiintifice aprofundate.
In general in Romania, bazinele riurilor nu sint considerate niste ecosisteme functionale,
ele sunt administrate tehnicist, aflindu-se sub autoritatea inginerilor hidrotehnici. Investitiile sau indreptat astfel doar spre constructii de baraje, indiguiri, desecari, praguri, captari, etc,fara
a fi luate in calcul nevoile de conservare a biodiversitatii din aceste bazine.
Zona ripariana este definita ca fiind invecinata sau conectata hidrologic cu reteaua apelor
de suprafata (de exemplu ape curgatoare, rauri, lacuri sau lacuri de acumulare). Zonele
ripariene sunt zonele tampon imediat superioare unei ape de suprafata cat si zone ce pot fi
mai departate fizic dar care sunt conectate hidrologic prin fluxul subteran (de exemplu soluri
hidrice sau umede ce se afla in apropierea unei ape curgatoare).
233
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
234
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Zonele ripariene sunt importante din punct de vedere ecologic pentru o varietate de
motive. Ele asigura un control al eroziunii prin regularizarea transportului si distributiei
sedimentelor, sporesc calitatea apei, produc materie organica pentru habitatele acvatice si
asigura habitatul salbatic. Zonele ripariene sunt de asemenea considerate indicatori ai
schimbarilor globale de mediu deoarece sunt sensibile la variatiile ciclului mediului
inconjurator si ale celui hidrologic (Risser, 1990). In plus, oamenii pretuiesc zonele riverane
ce reflecta beneficiile socio-economice. Desi zonele riverane cuprind de obicei o foarte mica
parte a peisajului, ele sunt foarte bogate in plante si animale, asigurind habitatul esential al
multor specii (Thomas et al. 1979, Knopf et al. 1988). Zonele riverane se numara printre cele
mai diverse, dinamice si complexe sisteme biologice de pe Pamant, avand o contributie
semnificativa la biodiversitatea regionala (Naiman et al. 1993).
Ecosisteme ripariene au forma liniara ca urmare si functie a vecinatatii lor cu ape
curgatoare si au adesea rapoarte mari intre margine si arie. Ecosisteme ripariene primesc si
prelucreaza mai multa energie si material de la peisajele invecinate decit alte tipuri de
ecosisteme, sunt conectate la alte ecosisteme, atit din aval cat si din amonte, superioare
(ecosisteme superioare) si inferioare (ecosisteme acvatice). In mod functional exista
interactiuni continue intre ecosistemele ripariene, acvatice si superioare prin schimb de
energie, substante nutritive si specii.
Ecosisteme ripariene apar de-a lungul cursurilor de apa, raurilor, paraiaselor, lacurilor sau
altor corpuri de apa si cresterea vegetatiei depinde de continutul relativ ridicat de umiditate
din sol. Au configuratii hidrologice si geomorfice complexe si sufera inundari periodice.Au
soluri aluviale sau de alte tipuri caracteristice (unele, nu toate zonele).Poseda functii speciale
legate de apa, cum ar fi controlul eroziunii.Sunt locuri productive cu nevoi speciale de
management. Implica o gama de tipuri de plante si de comunitati de plante.Au multiple valori
si utilizari ale resurselor.Au fost promovate interesul crescind al publicului, legislatia si
programele guvernamentale pentru a proteja, reface, schimba si spori zonele riverane.
Sunt caracterizate de o combinatie de puternica diversitate si densitate a speciilor
precum si de o mare productivitate.Au natura ecotonala (de tranzitie), aparind intre
ecosistemele acvatice si cele superioare; in orice caz, ele tind sa aiba caracteristici distincte
de vegetatie si de sol.
Ecosistemele ripariene asigura un habitat anual pentru multe specii de mamifere, reptile,
amfibiene si pasari, precum si locuri de crestere, de iernare si habitate de oprire pentru o
gama remarcabila de pasari migratoare.
235
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Pentru a mentine sanatoase zonele ripariene este necesara intelegerea modului lor de
functionare si a felului in care practicile agricole le afecteaza.Se va reduce, in orice caz,
disponibilitatea si alegerea naturala a ramasitelor lemnoase mari nesesare habitatului
pestilor. Se va pierde si umbra, permitind temperaturii curentului sa creasca si facind
curentul mai putin propice pastravilor chiar in curenti bazati pe ape subterane.
Dupa cum se poate vedea, administrarea zonelor riverane nu este usoara. De fapt este
un proces foarte complex ce implica multe interese diferite si ceea ce serveste unui interes
poate dauna altuia. Cel mai important lucru de retinut este ca nu exista o politica
unidimensionala general valabila.
Vegetatia riverana are cea mai mare influenta de-a lungul cursurilor superioare. Efectul
microclimatului descreste spre aval pe masura ce largimea curentului, raului sau lacului
creste relativ la inaltimea vegetatiei riverane. In orice caz, trebuie remercat ca atunci cind
apa din cursul superior are o temperatura ambientala joasa acest beneficiu ecologic se
transmite in aval. Atunci cind inversul este adevarat, exista putine posibilitati de racire iar o
crestere brusca a temperaturii apei semnaleaza inceputul unor impacturi adverse cumulative.
Efectele de eroziune ale climatului in geologia cumpenelor de ape determina in mod
fundamental structura si functia zonei riverane. Desi cumpenele sunt relativ uniforme intr-o
arie fiziografica, diferente exista din cauza ordinei, aspectului, elevatiei, geologiei locale,
solurilor, transportului de sedimente, apei, frecventei si momentelor inundatiilor, precum si
vegetatiei. Acesti factori sunt critici pentru planificarea managementului in zonele riverane.
Zona de management riparian (ZMR) este o zona proiectata si administrata in mod
constient pentru a proteja functiile si valorile zonelor ripariene. Ea poate fi un subset al, egala
cu, sau sa se extinda dincolo de zona riverana. De exemplu, zona riverana a unui curent de
apa anumit se poate extinde ecologic pina la virful unui mal abrupt adiacent aflat la 100 de
picioare de canalul curentului, insa zona sa de management riveran se poate extinde la 300
de picioare sau mai mult fata de canal pentru a atinge probleme legate de estetica si de
calitatea apei.
ZMR-urile constituie ultima linie de aparare impotriva poluantilor ce se indreapta spre un
canal. Vegetatia adecvata dintr-un ZMR ajuta la filtrarea si oprirea poluantilor cum sunt
sedimentele, excesul de substante nutritive si alte substante contaminante inainte de a
ajunge la apele de suprafata.
Din pacate curentii de apa ce curg prin zone cu o topografie relativ plana transporta
sedimente nisipoase foarte incet astfel incit efectele negative ale sedimentarii pot persista
decenii sau secole. Astfel, este critica prevenirea eroziunii excesive in cel mai inalt grad
posibil din cauza timpului lung necesar pentru refacerea sanatatii curentilor afectati de
sedimente.
Efectele distructive ale eroziunii excesive nu se reduc la organismele acvatice. Hrana
multor amfibieni, reptile, pasari si mamifere se cuprinde partial sau total din nevertebrate
acvatice sau din peste. Oprirea eroziunii in ZMR-uri este o prioritate inalta pentru
profesionistii ce se ocupa cu protectia resurselor deoarece efectele negative datorate
eroziunii se transmit de la mica musca la maiestuosul vultur plesuv. Sedimentarea excesiva
de la solurile expuse din ZMR-uri poate fi datorata eroziunii zonei superioare, insa lipsa unei
structuri de radacini ale plantelor de-a lungul malurilor face mai usoara taierea si eroziunea
acestora.
Dovada eroziunii malurilor si a largirii curentului este adesea foarte evidenta la curentii
unde proprietarii de pamint au eliminat copacii si i-au inlocuit cu iarba sau cu pajisti
ingrijite.Rezolvarea problemei stabilizarii eficiente a malurilor este mentinerea unei densitati
mari de tipuri de vegetatie cu radacini adinci de-a lungul malurilor pentru a proteja solurile
impotriva fortei de eroziune a apei.
236
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Zonele riparene in general sunt probabil pe locul doi dupa marginile drumurilor in
clasamentul celor mai vazute zone impadurite. Spre deosebire de acestea, zonele riverane
sunt observate cind oamenii se recreaza si se misca intr-un ritm mai lent. De aceea ei sunt
mai critici din punct de vedere estetic. Acesta este alt factor ce trebuie luat in considerare la
administrarea ZMR-urilor.
Sunt dese discutiile in care se pune problema daca coridoarele riverane impadurite sunt
superioare celor dominate de iarburi. Cheia este de a administra vegetatia coridorului
riparian pentru specii naturale mature care au ajuns sa creasca in conditiile specifice acelei
zone.
Este important de tinut minte ca ecosistemul riparian de-a lungul unui curent este
controlat de forma vailor, platoul apei (water table), conditiile de sol, curgerea apei
subterane si alte caracteristici ale curentului insusi. Vegetatia joaca un rol foarte important la
mentinera stabilitatii canalului astfel incit acesta sa nu se erodeze excesiv.
Canalul se va modifica in functie de cresterea sedimentelor, care va insemna depuneri
crescute de sedimente, eroziunea malurilor si schimbari in gradientul canalului. O consecinta
a acestora vor fi schimbarile in meandrele curentului pe masura ce acesta cauta sa se
stabilizeze. In final aceasta va duce la degradarea habitatului acvatic.
Dupa cum se poate vedea, administrarea zonelor ripariene nu este usoara. De fapt este
un proces foarte complex ce implica multe interese diferite si ceea ce serveste unui interes
poate dauna altuia. Cel mai important lucru de retinut este ca nu exista o politica
unidimensionala general valabila.
Vegetatia riverana are cea mai mare influenta de-a
lungul cursurilor superioare. Efectul microclimatului descreste spre aval pe masura ce
largimea curentului, raului sau lacului creste relativ la inaltimea vegetatiei ripariene. In orice
caz, trebuie remercat ca atunci cind apa din cursul superior are o temperatura ambientala
joasa acest beneficiu ecologic se transmite in aval. Atunci cind inversul este adevarat, exista
putine posibilitati de racire iar o crestere brusca a temperaturii apei semnaleaza inceputul
unor impacturi adverse cumulative.
Substratul de lunca influenteaza infiltratia. Intrucit nu sunt disponibile harti ale solului si
nu a fost remarcata nici o relatie simpla intre tipul solului si reflectanta suprafetei observate in
imaginile satelitare, se foloseste aici o cale indirecta de explicare a rolului acestui factor. In
raportul privind interactiunile dintre apele de suprafata si cele subterane (Wolski, 2003) s-a
consemnat ca infiltratia a fost determinata de evapotranspiratie si ca in cele citeva locuri
studiate solul de lunca a jucat un rol lipsit de importanta in determinarea fluxului de infiltratie.
Locurile studiate s-au situat in principal in zonele superioare si mijlocii ale Deltei, acolo unde
solurile de lunca sunt relativ nisipoase. In partea periferica a Deltei probabilitatea aparitiei
unui substrat argilos creste. Acolo solurile de lunca pot avea un efect limitativ asupra
infiltratiei. Ceea ce, la rindul sau, poate duce la o mai slaba dezvoltare a vegetatiei riverane.
In orice caz, zonele riverane sunt acolo adesea bine dezvoltate (Ringrose et al., 2003), ceea
ce indica faptul ca in zona periferica substratul luncii joaca un rol neinsemnat in determinarea
fluxului infiltrational. De aceea noi presupunem ca infiltratia poate fi evaluata indirect dupa
marimea unitatilor de vegetatie riverana.
Zonele ripariene sunt sensibile la practicile manageriale si la interventii pagubitoare.
Pasunatul excesiv, agricultura, despaduririle masive, constructia de drumuri, dezvoltarile
urbane si recreative se numara printre utilizarile zonelor ripariene si a zonelor umede
invecinate ce au in principal efecte negative asupra ecosistemelor riverane si acvatice.
Instalatiile militare pot avea probleme specifice asociate cu exercitiile militare din zonele
ripariene. Managementul judicios al pasunatului si al exploatarii lemnului poate fi compatibil
cu mentinerea unor habitate ripariene diverse si productive.
237
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
238
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
239
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Figura 5.
Figura 6
Rulourile din fibra stabilizeaza malurile permitind cresterea vegetatiei de zona umeda.
Fibra de nuca de cocos acumuleaza sedimente si se biodegradeaza pe masura ce radacinile
plantelor se dezvolta devenind un sistem stabilizator (de la Bestmann-Green Systems).
(Figura 6)
Figura 7
240
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
se aseaza in gauri sau santuri inguste astfel incit numai lastarii aerieni (aerial sprouts) sa
fie deasupra solului (Figura 7)
Figura 8
Acoperirea cu iarba este o metoda prin care bucati mari de sol si iarba sau plante
erbacee sunt desprinse din straturile in care se afla si transplantate in locurile cu probleme.
Mici sectiuni (5-10 cm latime si 5-10 cm lungime) pot fi sapate si luate din locurile necultivate
sau crescute in sera. Ele sunt asezate la o anumita adincime in sol ce permite expunerea
partilor aeriene ale plantei(Figura 8)
In Romnia sunt sectoare ale cursurilor de apa care pot constitui obiect al restaurarii unor
zone inundabile. Distrugerea zonelor inundabile este doar una din ameninrile la adresa
ecosistemului din zona carpato-dunrean, pe lng sistematizarea albiei fluviului,
privatizrile i retrocedrile de terenuri din lunca Dunrii, deversrile de ape poluate, lipsa
sprijinului financiar i tehnic, precum i a unor politici privind dezvoltarea turismului i a
zonelor rurale.
Pn la sfritul secolului al XIX-lea, Dunrea a fost un fluviu cu o larg reea de canale.
Numit adesea "Dunrea Albastr", ea i schimba adesea cursul i avea o structur
dinamic i n permanent schimbare a vilor inundabile. De atunci, interveniile drastice
asupra sistemului natural al Dunrii - pentru a mbunti protecia mpotriva inundaiilor,
agricultura, producia de energie electric i transportul fluvial - au dus la distrugerea a 80 la
sut din mlatinile vitale, vile inundabile i pdurile din lunca fluviului. Desecarea n scopuri
agricole a zonelor inundabile nu justific investiia, iar distrugerea lor are efecte
distrugtoare. Introducerea unor specii noi de pomi n pdurile din zonele inundabile sau
tierea exagerat "n numele industriei" altereaz funcionarea ecosistemului. Mai mult, "a
construi orae i sate n zonele inundabile nseamn a sacrifica aceste aezri n caz de
inundaii".
Vile inundabile ale Dunrii inferioare sunt arii de o biodiversitate deosebit, asigurnd
conservarea biodiversitii, purificarea apei, reducerea polurii, protecie n faa inundaiilor,
dar i potenial economic pentru pescuit i turism. n anul 2000, guvernele din Romnia,
Bulgaria, Ucraina i Republica Moldova au semnat o declaraie comun privind restaurarea a
peste 220.000 de hectare de vi inundabile aflate de-a lungul Dunrii inferioare, adic a unei
suprafee egale cu cea care lipsete acum fluviului n zona lui inferioar, unde 220.000 de
hectare sunt acoperite de ap. ncepnd din secolul al XIX-lea, ca urmare a schimbrilor
fcute de mna omului, inclusiv n urma construirii de canaluri i diguri, Dunrea a pierdut
15.000-20.000 de kilometri ptrai de vi inundabile, n momentul de fa fluviul mai avnd
mai puin de 19 la sut din suprafeele iniiale de acest tip.
241
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Pe Dunre, n lungul sectorului km 175 km 375, exista zone ripariene, zone umede si
inundabile care sunt si vor constitui obiecte ale restaurarii ecologice. Aceasta zona a Dunarii
este in mod traditional o resursa valoroasa pentru diversi beneficiari ai folosintelor fluviului
din vecinatatea Dunarii sau chiar mai indepartati, prin furnizarea de apa pentru irigatii,
asigurarea navigatiei, pescuit, agricultura in luncile fluviului, o sursa de nisip si pietris pentru
constructii, etc.
Proiecte de restaurare a zonelor inundabile in Romnia din pacate sunt putine, dar sunt
proiecte hidrotehnice cum ar fi constructia pragului de la Bala, proiect care prevede lucrri in
scopul optimizrii redistribuirii debitelor n vederea mbuntirii circulaiei pe Dunre care nu
au impact major negativ asupra biodiversitii. Trebuie facuta o corelatie intre proiectele
hidrotehnice si proiectele de restaurare o unor zone inundabile de pe raurile interioare.
Zone inundabile care trebuiesc restaurate sunt pe malul rului Trnava Mare n aval de
oraul Sighisoara, pe valea aeului (sector A. Iptescu) datorit colmatrii albiei namonte
de barajul din Corneti.
Bibliografie
Diaconu S.: Cursuri de apa Amenajare, Impact, Reabilitare Editura H*G*A, Bucuresti .1998
Despre implicatiile ecologice ale lucrarilor hidrotehnice de amenajare a cursurilor de apa. Rev. Hidrotehnica, Vol.
42., nr 6, 1997.
Constantin Parvu si Stoica Godeanu: Indrumator pentru cunoasterea naturii 1981
Constantin Parvu: Ecologie generala 2001
Razvan Voicu: Teza doctorat 2002
Bennett, P. S., M. R. Kunzmann, and R. R. Johnson. 1989. Relative nature of wetlands: riparian and vegetational
considerations. Pages 140-142 in D. L. Abell, technical coordinators. Proceedings of the California riparian
systems conference: protection, management, and restoration for the 1990's. U.S. Forest Service General
Technical Report PSW-110.
Brown, D. E., C. H. Lowe, and C. P. Pase. 1979. A digitized classification system for the biotic communities of
North America, with community (series) and association examples for the Southwest. Journal of ArizonaNevada Academy of Sci. Suppl. 1, 1-16.
Cowardin, L. M., V. Carter, F. C. Golet, and E. T. LaRoe. 1979. Classification of wetlands and deepwater habitats
of the United States. FWS/OBS-79/31. U.S. Fish and Wildlife Service, Washington, DC.
Delong, M. D., and M. A. Brusven. 1991. Classification and spatial mapping of riparian habitat with applications
toward management of streams impacted by nonpoint source pollution. Environmental Management 15:56571.
242
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
Inca din cele mai vechi timpuri, au existat asezari omenesti linga sursele de apa, avind in
vedere necesitatea asigurarii alimentarii cu apa si a evacuarii unei parti a reziduurilor
menajere si industriale in emisari. In prezent, volumul de apa captata si evacuata este in
continua crestere, proportional cu progresul economic si numarul populatiei. Consumurile de
apa in mediul urban sunt mai mari decit cele in mediul rural, deoarece unitatile de
gospodarire comunala livreaza apa pe linga populatie si agentilor economici. Sunt inca
orase, dar mai ales localitati in mediul rural care nu au statii de epurare si evacueaza direct
in sursa de suprafata sau subterana ape uzate menajere.
Directiva Consiliului 91/271/CEE prevede asigurarile pentru toate aglomerarile mai mici
de 10000 locuitori: sa fie colectate toate apele uzate si sa fie echipate cu statii de epurare la
nivel de epurare secundara. Directiva privind calitatea apei destinate consumului uman
prevede reabilitarea tehnologiilor de tratare, reabilitare retele de apa existente, schimbarea
instalatiilor exterioare.
Printre obiectivele specifice in domeniul apelor avute in vedere de autoritatile
administratiei publice locale si unitatile de gospodarie comunala, se numara: satisfacerea
cerintelor de apa ale populatiei, utilizarea eficienta a apei, imbunatatirea calitatii apei,
implicarea populatiei in managementul resurselor de apa. In vederea asigurarii cerintelor de
apa a populatiei si dotarii cu sisteme centralizate de canalizare ape uzate a localitatilor se
impun: evaluarea permanenta a resurselor de apa, introducerea instrumentelor financiare
adecvate, evaluarea impactului consumului de apa asupra mediului, alocarea fondurilor
financiare pentru intretinerea si exploatarea corespunzatoare a lucrarilor, realizarea lucrarilor
pentru captarea si epurarea apei, imbunatatirea infrastructurii pentru extinderea serviciilor de
aprovizionare cu apa. Programele de etapizare anexate autorizatiilor de gospodarirea apelor
ale unitatilor de gospodarire comunala cuprind masurile: intocmirea studiului de solutie
privind canalizarea si epurarea apelor uzate, intocmirea documentatiei necesare pentru
accesare fonduri in vederea realizarii lucrarilor cuprinse in studiul de solutie.
Pierderi mari de apa, consumuri exagerate, uzura fizica mare a instalatiilor, lipsa retelelor
de alimentare cu apa si canalizarea apei, lipsa statiilor de epurare, lipsa aparatelor de
masura a aparatelor de masura a debitelor de apa captate si evacuate, gradul de recirculare
al apei scazut, putine racordari la sistemele de alimentare cu apa si canalizare sunt citeva
din problemele actuale ale domeniului apei.
O analiza SWOT a serviciului de asigurarea cerintei de apa si epurarii apelor uzate se
prezinta astfel:
-puncte tari: participarea cetatenilor la indeplinirea proiectelor in domeniul apei; unirea
fortelor municipalitatii si serviciului public pentru rezolvarea problemelor legate de sistemele
de alimentare, canalizare si epurarea apei; existenta studiilor de solutie privind lucrarile ce
urmeaza a fi executate; existenta unor acte normative care permit urgentarea lucrarilor ;
sustinere politica din partea autoritatilor centrale si din partea Uniunii Europene.
243
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
-puncte slabe: lipsa resurse financiare, tehnice si umane pe plan local, in cadrul serviciilor
publice; nu exista harti digitale ale conductelor; legislatie stufoasa;
-oportunitati: legislatia nationala sprijina investitiile pentru sistemele de alimentare si
canalizare a apelor; monitorizare mai buna a calitatii serviciilor oferite; obtinerea finantarilor
din fonduri structurale; exista colaborare buna cu firme externe de consultanta;nivel crescut
de cooperare din partea ministerelor; imbunatatirea imaginii institutiilor publice si prestatorilor
de serviciu de utilitate publica.
-amenintari: modificari frecvente ale legislatiei in domeniu; diferentieri privind calitatea
serviciilor in mediul rural si urban; resurse financiare reduse pentru dotare tehnica
necesara;intirzieri in executia lucrarilor.
Referitor la directivele europene sus-mentionate, pentru judetul Dimbovita s-au obtinut
perioade de tranzitie 2018 si respectiv 2015. Pentru localitati cu pina la 10000 locuitori,
pentru asigurarea cerintelor de apa exista 2 proiecte pentru lucrari de investitii in promovare
si 4 proiecte in executie. Pentru lucrarile privind canalizarea si epurarea apelor uzate si a
capacitatilor acestora puse in functiune, exista 8 proiecte pentru lucrari de investitii in
promovare si 4 proiecte in executie. In prezent, exista 613 km de canalizare apa care
constituie 6,3% fata de lungimea necesara conform Documentului de Pozitie. Daca in 2008
gradul de racordare la sistemul de canalizare si epurarea apei este 2,8 %, in 2018 va fi de
100%.
In judetul Dimbovita, pentru realizarea sistemelor de alimentare cu apa a localitatilor cu
mai putin de 10000 locuitori, solutiile adoptate sunt de prelevare apa din sursa subterana,
drenuri sau retea oraseneasca a mun. Tirgoviste sau oras Pucioasa. Forajele sunt echipate
cu pompe submersibile LOWARA, OZ 615/18, ROVATTI, SP8A-10 cu debite de ~9 mc/h.
Dupa clorinare prin statii de clorinare, apa este transportata prin conducte de aductiune catre
cismele stradale si hidranti supraterani de incendiu.
Pentru o localitate cu aproximativ 5000 locuitori din judetul Dimbovita, statia de epurare
are capacitatea proiectata Q uzat orar max = 9,02 l/s, iar limitele de incadrare cu poluanti ai
apelor evacuate in resursele de apa conf. NTPA 001 si a incadrarii apelor menajere conf.
Normativ P 28 / 1984, gradul de epurare necesar al suspensiilor este de 80, 7 % , iar din
punct de vedere al CBO 5 este de 91,8 %. Statia de epurare realizata are 2 trepte :
-treapta mecanica compusa din caminul de repartitie ; camera gratarelor echipata cu
gratare; statia de pompare ape uzate; camera site si statie filtre saci.
-treapta biologica compusa din statie suflante; reactor biologic; platforma de depozitare
namol.
Caminul de repartitie distribuie apa in camera cu 2 gratare. Statia de pompare ape uzate
este echipata cu 2 electropompe submersibile tip PUMPEX K 100 cu Qp= 36mc/h min. si
un mixer submersibil avand P = 1,5 kw. Camera sitelor este o constructie in care sunt
amplasate statia de filtre saci, statia de suflante, gospodaria de reactivi, laboratorul de
analize fizico-chimice si separatorul automat cu perii. Acesta este tip sita rotativa automata
EUR-DSS 100-WEDGEWIRE si descarca materiile separate intr-un container, apa fiind
evacuata in reactorul biologic. Statia filtre saci este alcatuita din doua containere tip
DRAIMAD- TEKNOBAR din seria 3 BM. Namolul din bazinul biologic este pompat prin
intermediul unei pompe de namol SPN la statia de filtre saci unde este supus procesului de
deshidratare. Statia suflante este dotata cu 2 electrosuflante MEB si asigura cantitatea de
aer in procesul de aerare. Gospodaria reactivi cuprinde echipamente necesare dezinfectiei
apei uzate tratate in bazinul biologic.Injectia cu clor se face prin doua aparate de clorinare.
Din reactorul biologic, apa uzata este trimisa in bazinul de amestec. Namolul activ in exces
este trimis la statia filtre saci unde va fi supus procesului de deshidratare.
244
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
245
Conferinta Internationala
"Solutii pentru sisteme de alimentare cu apa si canalizare in localitati pana la 10.000 locuitori"
246