MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
Producator
S.C. ALCONEX S.R.L.
69 SERGENT NUTU ION
BUCURESTI 050762, ROMANIA
Aceste informatii sunt confidentiale si sunt proprietatea S.C. ALCONEX S.R.L si nu pot fi puse la dispozitia altora sau
reproduse in orice mod sau folosite pentru orice alt scop, cu exceptia unui acord scris sau a prevederilor din agrementul
semnat cu S.C. ALCONEX S.R.L pentru asemenea informatii.
PAGINA
1 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
CUPRINS
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
INTRODUCERE ........................................................................................................................... 4
1.
1.1.
1.2.
1.3.
1.4.
UTILITATI ...................................................................................................................... 10
1.5.
1.6.
COORDONATE PRODUCATOR................................................................................... 12
2.
3.2.
3.3.
3.4.
3.5.
4.
4.1.
INSTRUCTIUNI OBLIGATORII PRIVIND FUNCTIONAREA SKIDULUI LTS .............. 25
4.1.1. Generalitati ................................................................................................................. 25
4.1.2. Sisteme de aerisire si supape de siguranta ............................................................... 25
4.1.3. Masuri si mijloace de protectie contra efectelor electricitatii statice ........................... 26
4.1.4. Alte prevederi ............................................................................................................. 26
4.2. PUNEREA IN FUNCTIUNE A SCHIDULUI LTS..............................................................26
4.3.
4.4.
5.
6.
PAGINA
2 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
7.5.
7.6.
PAGINA
3 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
INTRODUCERE
Skidul LTS reprezinta o unitate compacta destinata filtrarii gazului de sonda si separarii
produselor condensabile din gaz.
"Basic Design" - "Proiectarea de baza" a fost realizata de firma S.C. ALCONEX S.R.L. Bucuresti ("Condensate stabilization package and Skid LTS).
Ingineria de detaliu privind realizarea Skidului LTS ca unitate compacta pentru purificarea
gazului de sonda a fost realizata de Petrodesign S.A.
Manualul de operare impreuna cu manualele de operare/instructiunile de operare ale
echipamentelor ce alcatuiesc skidul LTS constituie baza de operare a instalatiei de catre
personalul de operare al utilizatorului final.
Continutul cartilor tehnice ale echipamentelor, manualului de operare al skidului LTS, impreuna
cu manualele/instructiunile de operare ale echipamentelor ce intra in componenta skidului vor fi
incorporate in manualul de operare elaborat de utilizatorul final.
La elaborarea regulamentului de operare al instalatiei utilizatorul final va trebui sa tina seama si de
prevederile legale referitoare la sarcinile personalului de exploatare, cum sunt:
Legea nr. 319 din 14 iulie 2006 - Legea securitatii si sanatatii in munca;
Legea nr. 10/1995 privind calitatea in constructii;
Legea nr.265 din 29 iunie 2006 pentru aprobarea Ordonantei de urgenta nr.195/2005 privind
protectia mediului;
HG 1048/2006 Hotarare privind cerintele minime pentru utilizarea de catre lucratori a
echipamentului individual de protectie la locul de munca;
Ordinul nr. 22/1995 Ordinul privind aprobarea normativului cadru de acordare si
utilizare a echipamentului individual de protectie;
Utilizatorul final are datoria de a aduce pe parcursul exploatarii imbunatatirile cuvenite manualului
de operare, constatate din activitatea zilnica, precum si de a stabili parametrii optimi economici in
exploatare pe baza experientei acumulate.
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
4 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
Sunt imposibil de anticipat toate situatiile care pot apare in fata celui ce exploateaza instalatia in
timpul unei indelungate functionari.
Din acest motiv, procedurile si manevrele prezentate precum si conditiile din prezentul manual vor
fi considerate ca un ghid.
Dupa perioada de punere in functiune este posibil ca manevrele si conditiile prezentate sa fie
imbunatatite in scopul perfectionarii lor pentru obtinerea unei exploatari intensive a instalatiei.
Mentiune: Este interzis utilizatorului final sa faca modificari ale skidului LTS fara aprobarea
S.C. ALCONEX S.R.L.
ANEXE
Anexa 1: Scheme P&ID
Anexa 2: Plan general
Anexa 3: Plan de incadrare in zona
Anexa 4: Specificatii tehnice ale utilajelor
-Filtru 310-F-001A
-Filtru 310-F-001B
-Separator 313-V-001
-Schimbator cu placi 311-E-001
-Schimbator cu placi 312-E-001
Anexa 5: Lista parametrilor tehnologici
ACX-0106-LTS-PID-001 Sh 1
ACX-0106-LTS-PID-001 Sh 2
ACX-002-AE-PG
PD232014-003-000LTS-3310-0001-3-LDR
ACX-0106-LTS-310-F001A-SPEC
ACX-0106-LTS-310-F001B-SPEC
ACX-0106-LTS-313-V001-SPEC
830261
830262
PD232008-003-000LTS-2100-0003-4-LIS
1. DATE DE PROIECTARE
1.1. DATE DE PROCES
Scopul lucrarii consta in prezentarea tehnologiei aplicate in cadrul obiectivului Skid LTS din
cadrul grupului de prelucrare gaze de sonda, locatia Poduri jud. Bacau, apartinand grupului
STRATUM Energy LLC.
Skidul LTS reprezinta o unitate compacta destinata filtrarii gazului de sonda si separarii
produselor condensabile din gaz.
Cantitatea de gaz prelucrata este 750.000 Nm3 /zi obtinandu-se in final o cantitate de gaz curat
de circa 37 100 Nm3/h .
Totodata prin prelucrarea gazului in cadrul acestei unitati, se obtine o cantitate de produs lichid
( C3,C4,C5,C6, C7, C8, C9) care va fi utlizata in diverse scopuri.
Dupa cum s-a precizat instalatia Skid LTS prelucreaza gaze de sonda.
MATERII PRIME
Calitatea si cantitatea gazului de sonda prelucrat sunt prezentate in tabelele de mai jos.
PAGINA
5 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
Componenti
Oxigen
Azot
CO2
Metan
Etan
Propan
i-Butan
n-Butan
i-Pentan
n-Pentan
n-Hexan
n-Heptan
n-Octan
Nonan+
C10
C11
C12
C13
C14
C15
C16
C17
C18
C19
C20
C21
C22
C23
C24
C25
C26
C27
C28
C29
C30
C31
C32
C33
C34
C35
C36
TOTAL
H2O
% Volume
-
% Fractie
molara
0,37825
0,63103
88,48266
4,29373
1,88641
0,31546
0,67209
0,26155
0,28935
0,39128
0,50881
0,49590
0,34459
0,23583
0,15993
0,12188
0,9834
0,09139
0,07981
0,05684
0,04471
0,03840
0,02952
0,02167
0,01720
0,01327
0,01052
0,0078
0,00567
0,00449
0,00330
0,00229
0,00192
0,00130
0,00099
0,00078
0,00042
0,00025
0,00016
0,00015
100,00
saturat
% Masa
g/Nm3
0,4923
1,2906
65,8084
5,9877
3,8583
0,8505
1,8120
0,8754
0,9684
1,5642
2,3652
2,6278
2,0503
1,5566
1,1597
0,9631
0,8411
0,8411
0,7865
0,5972
0,4988
0,4533
0,3678
0,2840
0,2367
0,1912
0,1584
0,1238
0,0929
0,0765
0,0583
0,0419
0,0364
0,0255
0,0200
0,0164
0,0091
0,0055
0,0036
0,0036
100,00
saturat
PAGINA
6 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
U.m.
Maxim
Normal
Minim
Temperatura de intrare
35
25-35
Presiune
barg
51
45
36
Debit de lichid
m3/h
Debit de gaze
Nm3/zi
37,500
12,500
Densitate gaz
Kg/NM3
0,769
20
PRODUSE FINITE
Calitatea si cantitatea produselor finite sunt prezentate in tabele de mai jos.
Componenti
Oxigen
Azot
CO2
Metan
Etan
Propan
i-Butan
n-Butan
i-Pentan
n-Pentan
n-Hexan
n-Heptan
n-Octan
Nonan+
TOTAL
H2 O
Heliu
Argon
H2S
% Volume
0,3943
0,6479
91,4385
4,3609
1,8556
0,2708
0,5510
0,1586
0,1489
0,0945
0,0591
0,0123
0,0065
99,9989
Echivalent
punct de
roua la 150C
<1 ppm
% Fractie
molara
0,3930
0,6501
91,2879
4,2897
% Masa
0,6074
1,5785
80,8011
7,2826
4,5967
1,8894
0,2817
0,9033
0,5737
1,8397
0,1687
0,6715
0,1617
0,6437
0,1056
0,5021
0,0710
0,3925
0,0165
0,1040
0,0106
0,0750
99,9991
99,9981
Echivalent
Echivalent punct punct de roua
la -150C
de roua la -150C
PAGINA
7 of/din 76
g/Nm3
4,9283
12,8079
655,6141
59,0903
37,2976
7,3296
14,9273
5,4488
5,2227
4,0738
3,1849
0,8438
0,6086
811,3777
Echivalent punct de
roua la -150C
-
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
U.m.
Maxim
Normal
Minim
Temperatura
-7
-7
-7
Presiune
barg
51
Debit de lichid
m3/h
36
1
% Volume
Oxigen ( O2 )
Azot ( N2 )
Bioxid de carbon(CO2)
Metan(C1)
Etan(C2)
Propan(C3)
Izo-butan(C4)
N-butan(C4)
Izo-pentan(C5)
N-pentan(C5)
Hexan(C6)
Heptan(C7)
Octan(C8)
Nonan(C9)
C10
C11
C12
C13
C14
C15
C16
C17
C18
C19
C20
C21
C22
C23
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
% Fractie
molara
0,014
0,172
14,814
1,812
1,829
1,204
3,258
2,698
3,637
7,880
11,984
13,060
9,098
6,416
4,352
3,316
2,676
2,487
2,172
1,547
1,217
1,045
0,803
0,590
0,468
0,361
0,286
PAGINA
8 of/din 76
% Greutate
0,004
0,068
2.126
0,487
0,722
0,626
1,694
1,741
2,348
6,075
10,743
13,347
10,439
8,168
6,085
5,053
4,413
4,413
4,127
3,133
2,618
2,379
0,3678
1,490
1,242
1,003
0,831
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
C24
C25
C26
C27
C28
C29
C30
C31
C32
C33
C34
C35
C36
TOTAL
H2O
H2S
Densitatea condensatului
200C (Kg/m3)
0,214
0,154
0,122
0,090
0,062
0,052
0,035
0,027
0,021
0,011
0,007
0,004
0,004
100,000
la
0,650
0,487
0,401
0,306
0,220
0,191
0,134
0,105
0,086
0,048
0,029
0,019
0,019
100,000
766
310-F-001A/B
37 500 Nm3/h
63 barg
-29C / 65C
PAGINA
9 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
Temperatura;
Temperatura media anuala:
+10.4C
Temperatura absoluta minima: -29C
Temperatura absoluta maxima: +50C
Adancimea de inghet a solului este 0,8 m.
Numarul zilelor friguroase pe an: 110 zile (T<0C)
Media anuala a precipitatiilor este 578,8 mm, repartizata astfel:
Iarna
107,1 mm
Primavara
152,1 mm
Vara
180,5 mm
Toamna
139,1 mm
Directia predominanta a vantului este din Nord-Est (14,9%) si Est (13,3%).
1.4. UTILITATI
Agent de racire;
Agentul de racire folosit este propan, cu temperatura de -14. Agentul de racire
este preparat intr-o unitate de racire, compusa dintr-un compresor, un condensator
de aer si un evaporator, aflata in apropierea skidului LTS.
Caracteristicile agentului de racire furnizat de unitatea de racire, este prezentat in tabelul de
mai jos:
Unitati de
masura
Fluidul
Concentratia
pH (propan)
Nr. Crt.
metri
i de
proc
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
Amplasarea skidului LTS: Skidul LTS este o unitate de productie compacta, amplasata in
cadrul complexului de prelucrare gaze de sonda, Poduri, apartinand grupului STRATUM
Energy LLC.
Amplasamentul este prezentat in planul general nr: PR 856-SG002-0,CI 13-557, anexat la
proiect.
Densitate
Viscozitatea/
Viscosity
Debit maxim
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
propan agent
termic de racire
99
unitati de pH
Temperatura
4
Valoarea
-14
Densitate
kg/m
Temperatura
-14
cP
Dinamica/Dynamic
Capacitate
PAGINA
10 of/din
76
1,56
litru/h
20 700
litru/min
345
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
Min
Max
Minim
barg
Maxim
barg
3,5
Minim
-14
Maxim
-15
Minim
barg
Maxim
barg
3,5
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
Domeniu
Presiune
Temperatura de
operare
Presiune de
operare
Aer comprimat
Energie electrica
Standarde internationale
ISO 9001
Quality System for Design
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
11 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
ISO 12944
Alte standarde
97/23/EU
PED Pressure Equipment Directive
SR EN 13445 Pressure Vessel Standards
SR EN 1092-1 Flanges and their joints Circular Flanges for pipes, valves, fittings and
accesories, PN designated Part1: Steel Flanges
1.6. COORDONATE PRODUCATOR
Producator:
Client:
Utilizator final:
Unitate de
masura
Valoarea
Debit necesar
m3/zi
750 000
Presiune de operare la
intrare in skid
barg
36-51
Temperatura de operare
la intrare in skid
20-35
Presiune de operare la
iesire din skid
barg
36-51
Temperatura de operare
la iesire din skid
-7C
Incadrarea utilajelor skidului LTS din punct de vedere al certificarii PED este:
Fluid
grupa 1
PED
categoria IV
MODUL
G
3.
PAGINA
12 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
Nr.
Poz.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
crt.
0
Denumire si
functie
tehnologica
2
Filtru
Filtru cu cartus
coalescer
filtrant
310F-001A
interschimbabil
Filtru
coalescer
Filtru coalescer
310-F-001B
311-E-001
Schimbator de
caldura cu placi
312-E-002
Schimbator de
caldura cu placi
313-V-001
Separator la
temperaturi
scazute
Buc
Caracteristici
principale
unitara
Cilindric,vertical
V= 1,450 m3
D=0,8 m; H=2,3
m
Plucru =63 barg
T de lucru=-2965C
Greutate= 2800
kg
Greutate in
functiune = 3500
kg
Izolatie
rece=19+6 mm
Cilindric,vertical
V=1,450 m3
D=0,8 m; H=2,3m
Plucru =63 barg
Tde lucru=-2965C
Greutate in
functiune =
3500kg
Izolatie
rece=19+6 mm
Cilindric, vertical
D=0,84 m;
L=1,309 m
Plucru= -5-63 barg
Tlucru=-29-+65C
Izolatie rece=19
mm
Cilindric, vertical
V=0,7 m3
D=0,84m; L=1,055
m
Plucru= -5-+63 barg
Tlucru= -29-+65C
Izolatie rece=19
mm
Cilindric, orizontal
V=3,5 m3
DN=1; H=4 m;
Lungime=5,2 m
Plucru= 63 barg
Tlucru= -29-+65C
Greutate=4100 kg
Greutate in
functiune = 6400
Greutate (kg)
Material
totala
6
2800
Otel
carbon
2800
Otel
carbon
Manta - Otel
carbon
PlacileAISI 316L
Manta-Otel
carbon
PlacileAISI 316L
PAGINA
13 of/din
76
4100
Otel
carbon
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
Nr.
Poz.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
crt.
0
Denumire si
functie
tehnologica
Greutate (kg)
Buc
Caracteristici
principale
unitara
Material
totala
6
kg
Izolatie rece=19
mm
No. pozitie
Supapa de
siguranta pe filtrul
310-F-001A
Supapa de
310-PSV siguranta pe filtrul
002
310-F-001B
Supapa de
siguranta pe
31-PSV-001
conducta 80-AV005-ACR3A-VP
Supapa de
siguranta pe
31-PSV-002
conducta 80-AV007-ACR3A-VP
Supapa de
313-PSV- siguranta pe vasul
001
separator 313-V001
310-PSV001
Presiunea
de setare
(barg)
Conexiuni
intrare/
iesire
Material
61,4
DN80/
DN100
inox
61,4
DN80/
DN100
inox
61,4
DN80/
DN100
inox
61,4
DN80/
DN100
inox
61,4
DN80/
DN100
inox
Denumirea
Caracteristici
Mediu: gaz natural
Temperatura de
operare=20C
Mediu: gaz natural
Temperatura de
operare=20C
Mediu: gaz natural
Temperatura de
operare=5C
PAGINA
14 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
3.4.
Procesul tehnologic aplicat in unitatea Skid LTS reprezinta un procedeu clasic de purificare
de impuritati si separare produse condensabile din gazul de sonda.
Procesul prezinta insa particularitatea realizarii lui intr-o instalatie compacta, tip Skid
care ocupa o suprafata relativ redusa 4x6,5 m, comparativ cu o instalatie clasica
Aceasta descriere se va consulta simultan cu schemele PID: ACX-0106-LTS-PID-001 filele 1 si
2.
Gazul de sonda, de la coloana de uscare a gazului cu TEG, cu presiunea de circa 51 barg,
este adus la limita Skidului si alimentat in filtrul coalescer 310-F-001A. Filtrul coalescer 310-F001B este de rezerva. Temperatura gazului la intrarea in Skid este masurata cu ajutorul lui 31TE-001 si trimisa la DCS din camera centrala a platformei/skidului. Este prevazuta o
semnalizare de maxim, la valoarea de 35C.
Punctul de roua la intrare a gazului este deasemenea important, fiind prevazuta o semnalizare
de punct de roua a aparatului 31-WDPT-001 care transmite valoarea la DCS din camera
centrala (31-WDPIT-001). Este prevazuta o semnalizare de maxim la valoarea temperaturii de 26C.
Gazul intra in filtrul coalescer 310-F-001A prin racordul N1 de DN150 unde se separa
impuritatile din gaz si retine particulele de apa ramase. Filtrele sunt prevazute cu cartuse
filtrante interschimbabile. Filtrele 310-F-001A si 310-F-001B nu lucreaza concomitent.
Se masoara caderea de presiune pe filtru pentru a stabili momentul in care filtrul s-a
infundat cu ajutorul lui 310-PDT-001, respectiv 310-PDT-002 care transmite semnalul in
camera de comanda la 310-PDI-001, respectiv 310-PDI-002. Este prevazuta o semnalizare de
alarmare la maxim 100 kPa (0,1 bar).
Sunt prevazute 2 indicatii locale de temperatura dupa cum urmeaza: 310-TG-001, respectiv
310-TG-002 si indicatii locale de presiune: 310-PG-001, respectiv 310-PG-002. Nivelul maxim
de lichid in filtru este masurat cu 310-LSH-001, respectiv 310-LSH-002 si transmis la DCS.
Semnalul de la senzorul de nivel 310-LSL-001, respectiv 310-LSL-002 este transmis de catre
ventilul cu actionare automata ON/OFF 310-SDV-001, respectiv 310-SDV-002 care regleaza
evacuarea lichidului acumulat in filtru. Senzorul de nivel prevazut cu cu releu de temporizare,
deschide robinetul de evacuare la intervalul de timp setat de ,,x minim si se evacueaza lichid la
conducta de scurgere a instalatiei.
Nivelul minim de lichid in filtrul este masurat cu 310-LSL-001, respectiv 310-LSL-002 si
transmis la DCS prin 310-LAL-001 si 310-LAL-002. La atingerea valorii de minim se inchide
robinetul 310-SDV-001, respectiv 310-SDV-002..
Filtrele 310-F-001A/B, sunt prevazute si cu indicatoare de nivel locale, atat pentru
compartimentul superior, cat si pentru compartimentul inferior.
Nivelul lichidului in compartimentul superior - zona cartusului fitrant este masurata cu
indicatorul de nivel magnetic 310-LG-001, respectiv 310-LG-003.
Nivelul lichidului in compartimentul inferior al filtrului coalescer este masurat cu ajutorul
indicatorului magnetic de nivel 310-LG-002, respectiv 310-LG-004.
Pentru situatii in care presiunea gazului depaseste cu mult presiunea de lucru, cele doua filtre
sunt prevazute cu supape de siguranta: 310-PSV-001 respectiv 310-PSV-002 setate la
presiunea de deschidere de 62,4 barg. Supapele esapeaza in conducta colectoare de gaze
reziduale a skidului.
Interventiile care necesita depresurizarea filtrului se fac prin intermediul unor linii prevazute cu
orificii de restrictie pentru a se asigura depresurizarea treptata.
Eventualele scurgeri de lichid (apa, hidrocarburi) care se pot acumula in timpul exploatarii pot fi
scurse prin partea de jos a filtrelor in conducta de scurgere a skidului, fiind dirijate la vasul
colector al statiei.
Pentru a se evita racirea gazului in filtru, in special in anotimpul rece si formarea unor mari
cantitati de condens, filtrele se izoleaza cu izolatie cu grosimea de 23 mm.
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
15 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
16 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
Pe conducta de gaz rece care este trimis la separatorul 401-V-001 este montat indicatorul
local de temperatura 31-TG-008 si indicatorul de temperatura cu transmisie la DCS, 31-TE-007
care trimite semnalul la DCS, la aparatul 31-TI-007 si are o valoare de alarmare maxim 15C.
Deasemenea presiunea pe aceasta conducta este transmisa la DCS (aparatul 31-PI-006).
Valoarea de alarmare pentru acest aparat este maxim 60 bar si minim 26,5 bar.
Gazul racit care iese din schimbatorul 311-E-001 trece la racirea finala (a doua treapta de
racire) in schimbatorul 312-E-001, unde este racit pana la temperatura de -7C. La aceasta
temperatura condenseaza toate hidrocarburile >C4.
Avand in vedere temperatura necesara pentru condensare, agentul de racire utilizat este
propan la temperatura de -14C. Agentul de racire este preparat intr-o unitate de racire,
compusa dintr-un compresor, un condensator de aer si un evaporator, aflata in apropierea
skidului LTS.
Functionarea si operarea acestuia sunt descrise in manualul de operare al echipamentului
Chiller elaborat de catre producatorul acestuia.
Gazul cu temperatura de 14C este alimentat in cel de-al doilea schimbator cu placi, 312-E001. In schimbatorul cu placi 312-E-001, gazul se raceste de la 14C la temperatura de -7C.
Pe conductele de intrare si de iesire ale gazului este montat un indicator de presiune
diferentiala 312-PDT-001, care are transmisie la DCS-ul din camera de comanda la indicatorul
312-PDI- 001. Aparatul masoara caderea de presiune intrare/iesire schimbator. Aceasta
masuratoare va indica daca nu cumva schimbatorul s-a infundat datorita criohidratilor sau din
alte cauze. Valoarea de alarmare prevazuta este maxim 40 kPa.
Pe conducta de iesire gaz spre separatorul 313-V-001 este montata supapa de siguranta 31PSV-002, setata sa deschida la 62,4 barg.
Agentul de racire folosit, propanul, este vehiculat cu ajutorul unuii compresor si este
alimentat cu presiunea de 2 bar si temperatura de -14C. Debitul de agent de racire este reglat
prin intermediul unui regulator 31-TCV-001 actionat de termorezistenta 313-TE-001, montata in
varful separatorului 313-V-001.
Schimbatorul cu placi 312-E-001 este prevazut pe conductele de intrare/iesire propan cu un
indicator de presiune diferentiala 312-PDT-001 care transmite la DCS, la indicatorul 312-PDI001. Indicatorul este prevazut cu alarmare de maxim la 40 kPa. Aparatul masoara caderea de
presiune pe sistemul de racire, indicand daca nu s-a produs o infundare din cauza depunerii
criohidratilor sau alte cauze.
Gazul racit care contine si produsele condensabile este dirijat la separatorul 313-V-001. Pe
conducta de legatura dintre schimbator si separator este montat un indicator local de
temperatura, 31-TG-005. In separatorul 313-V-001, are loc separarea produselor condensabile
de gazul combustibil care dupa ce este utilizat ca agent de racire in treapta intai de racire, este
introdus in reteaua de gaz pentru a fi livrat la unitatea Flash.
Vasul este prevazut cu demister, situat la iesirea gazelor, pentru separarea eventualelor
picaturi de lichid care pot fi antrenate. Temperatura, la partea superioara a vasului, este
indicata de indicatorul 313-TE- 001, cu transmitere la 313-TIC-001 care actioneaza ventilul cu
trei cai 31-TCV-001 de pe conducta de intrare a agentului de racire, propanul, din schimbatorul
cu placi 312-E-001.
Nivelul minim de lichid din baza separatorului este indicat la tablou de aparatul 313-LALL001 care actioneaza ventilul cu solenoid 31-SDV-001 de pe conducta de transmitere a lichidului
la separatorul trifazic. Acest ventil este actionat in cazul atingerii nivelului minim din vas(50mm).
Exista si alarmare la nivelul minim din vas. In functionare normala, debitul de lichid care va fi
transmis la separatorul trifazic este reglat prin intermediul robinetului de regalare 31-LCV-001
actionat de indicatorul de nivel 313-LT-001. Presiunea in vas este indicata la manometrul local
313-PG-001, iar temperatura este indicata la termometrul 313-TG-001.
Nivelul maxim de lichid din separator este indicat de aparatul 313-LAHH-001 si alarmeaza cand
nivelul lichidului ajunge la maxim(700mm). Separatorul 313-V-001 este prevazut cu un indicator
de presiune diferentiala 313-PDT-001 care transmite la DCS, la indicatorul 313-PDI-001.
Indicatorul este prevazut cu alarmare de maxim. Aparatul masoara caderea de presiune pe
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
17 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
demister, indicand daca s-au strans prea multe picaturi sau particule antrenate de gaz sau alte
cauze.
Schemele PID corespunzatoare sunt : ACX-0106-LTS-PID-001, filele 1 si 2.
INSTRUCTIUNI DE LUCRU CU AGENTUL DE RACIRE - PROPANUL
Propanul comercial utilizat in sistemul mic vrac atat la uz casnic cat si industrial are
urmatoarele caracteristici conform STAS 8723-70:
Caracteristici
Valori
Tip 2
Tip 1
Compozitie chimica
2,5 % gr max
5 % gr max
C2 total
2% gr max
2 %gr max
Propilena
93,5% gr max
92% gr max
Propan
2% gr max
2% gr max
Hidrocarburi C4
Miros (odorizat cu etil mercaptan)
Da caracteristic
Da Caracteristic
Presiune de vapori la 10 0 C
La 50 0 C
17,65
17,65
La 700 C
Sulf total dupa odorizare mg/ N m3
Max 500 mg/ Nm3
Max 500 mg/ Nm3
Temperatura reziduului dupa evaporare
1
1
Densitatea lichid la 150 C
0,5007 Kg/m 3
0,0504 kg/m3
- gaz
Apa
lipsa
lipsa
Propanul, in stare gazoasa, este mai greu ca aerul, se concentraza in zonele cele mai joase ale
spatiului in care se gaseste. O pierdere de propan in faza lichida este mult mai periculoasa
decat in faza gazoasa, avand in vedere faptul ca prin pierderea unui volum de lichid rezulta prin
evaporare circa 270 volume de gaze.
O alta caracteristica a propanului o reprezinta inflamabilitatea - capacitatea propanului de a se
aprindere de la o sursa de foc.
Propanul, cand este prezent in faza gazoasa in atmosfera, poate forma amestecuri foarte usor
inflamabile si explozive a caror prezenta nu e usor de sesizat.
In schimb, cand sunt scapari in faza lichida se formeaza o ceata caracteristica, ce tinde sa se
adune in zone sub cota terenului (nor de gaze) si care este usor inflamabil.
Propanul nu este toxic. Totusi, avand proprietati anestezice e bine sa se evite inspirarea lui.
Inhalat in cantitati mari produce decesul persoanei (aritmie). Propanul pur este lipsit de miros,
dar folosit pentru uz casnic sau la auto, trebuie sa fie odorizat asa incat eventualele scurgeri sa
fie imediat semnalate (se utilizeaza compusi de mercaptani). Propanul lichid este mai usor ca
apa, asa ca, in recipient apa se pozitioneaza la partea inferioara, necesitand ca periodic sa se
faca purjari.
Prezenta apei in propan, poate determina, in cazul temperaturii joase sub 00C
inconveniente grave, de exemplu astuparea cu dopuri de gheata a sistemelor de inchidere, atat
pe faza lichida cat si pe cea gazoasa, precum si blocarea ventilelor chiar in pozitia deschis.
Gheata apare si ca efect al evaporarii bruste a fazei lichide (detenta), atingandu-se temperaturi
foarte joase cu pericol de ardere (arsura rece) la contactul cu pielea. Propanul in stare lichida,
din cauza rapidei lui evaporari, daca vine in contact cu epiderma, poate provoca leziuni similare
cu arsurile, chiar de o gravitate mai mare decat apa fiarta. Este necesar sa se evite contactul cu
propanul si trebuie purtate manusi de protectie.
Propanul in stare lichida este supus unor puternice variatii de volum, odata cu variatiile de
temperatura. El nu corodeaza otelul din care este confectionat recipientul. Propanul cauzeaza
fenomene de deformare a cauciucului natural, asa ca furtunurile folosite trebuie sa fie facute din
cauciuc sintetic, de calitate corespunzatoare. Pentru legaturile filetate, trebuie sa se foloseasca
masticuri speciale sau chiar banda de teflon.
PAGINA
18 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
Pericolul mare apare cand un vas de propan este supus in caz de incendiu, unei cresteri
permanente a temperaturii. Cresterea temperaturii in interiorul vasului nu continua decat atat
timp cat deasupra propanului lichid exista un spatiu umplut cu vapori.
Cand temperatura creste, gazul se dilata, putandu-se ajunge ca intreg volumul vasului sa fie
umplut cu gaz lichefiat, fara sa mai existe un spatiu cu vapori. Incepand din acest moment, la
cresterea temperaturii, presiunea creste mult mai rapid decat valorile curbei presiunii de vapori.
Cresterea presiunii este de 7-8 bari pentru fiecare crestere a temperaturii. Ca urmare a
compresabilitatii mici a propanului si a capacitatii elastice de dilatare relativ mici a peretilor
vasului, acesta explodeaza.
Proprietati fizico-chimice
GPL
Formula
Greut. Greutatea specifica
Putere calorifica
chimica
Molec lichid
gaz
Kcal/Nm3
Kcal/kg
.
Propa
C3H8
44
0,511 kg/ l
1,96 kg/Nm3
21700
11070
n
Parametrii tehnici de siguranta pentru GPL
Denumire
Temperatura de
Temperatuara critica Presiune critica Factor de
lichefiere
umplere
Propan
- 430C
960C
42,5 bar
2,35
Toate acestea sunt din ratiuni pentru protectia mediului si economic.
NOTA: Amplasarea constructiilor si instalatiilor in parcul de sonde Poduri este prezentata in
planul general al investitiei.
LA VAS S-AU PREVAZUT PRIN PROIECT, conform Schemei de Conducte si
Automatizari ACX-0106-LTS-PID-001 urmatoarele:
- o gura de vizitare GV;
- racord intrare propan N1 DN 80;
- racord iesire propan N2 DN 80;
- racord supapa de siguranta N3 DN 80;
- racorduri sticla de nivel N6/N7 DN 50;
- racord de aerisire N4;
- racorduri pentru termometru si manometru N11/N10;
- racorduri pentru swich de nivel maxim si nivel minim N9/N8
- armaturi automate, de siguranta,care sunt armaturi pe pozitia Normal inchis,
actionate pneumatic, pentru descchidere si electric in caz de emergenta pentru inchidere
fortata. S-a folosit actionate pneumatic pentru deschidere,caci in caz de emergenta si este
nevoie pentru intreruperea curentului electric,atunci posibilitatea de inchidere rapida a acestor
armaturi se realizeaza prin depresurizarea rapida a liniei de alimentare cu aer instrumental.
- conectarea valorilor parametrilor principali (temperatura, presiune, nivel) la un tablou
local, amplasat in zona compresorului. Astfel operatorul de la parc, are posibilitatea de a
urmari parametrii si de a sesiza orice modificare negativa a acestora;
- transmiterea parametrilor de pe vas la un pupitru de comanda, prevazut cu monitor, de
unde se poate urmari de catre operator continuu evolutia parametrilor;
- pupitru de comanda, amplasat in camera de comanda, de unde se pot actiona (sa
deschida sau sa inchida) armaturile automate actionate pneumatic si se poate porni si opri
compresorul;
- echiparea parcului cu detectoare fixe, care sesizeaza scaparile de propan in atmosfera
cand prin panoul Gasmonitor, se anunta aceasta scapare vizula prin autoaprinderea lampilor de
pe panou si acustic .
- instalatiile fixe de racire, izolare si stingere amplasate langa vasul de propan, au rolul
de racire a rezervorului in cazul producerii unui incendiu, de a izola prin perdele de apa
rezervorul incendiat de alte rezervoare si de a stinge focarele din zona;
- gospodarie apa de incendiu cu o retea de hidranti exteriori precum si cu colectoare pentru
racordarea masinilor de interventie.
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
19 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
20 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
2
Filtru cu
310-Fcartus
1
001A
interschim
babil
Filtru cu
310-Fcartus
2
001B
interschimba
bil
Schimbator
311-E3
de caldura
001
cu placi
Schimbator
312-E4
de caldura
001
cu placi
Separator la
313-V5
temperaturi
001
scazute
Lista parametrilor tehnologici
anexa.
45
36
51
51
45
36
25-35 -29
35
31 250 12500
25-35 -29
35
31 250 12500
45
36
63
14
-29
15
10 000 2 100
45
36
63
-7
-29
-7
10 000 2 100
45
36
63
-7
-4
50
700
Personal
Skidul LTS fiind o instalatie compacta poate fi urmarita in exploatare de 1 operator pe schimb.
3.5. DESCRIEREA SISTEMELOR DE MASURA SI CONTROL
Prezentul capitol al manualului de operare serveste la elaborarea capitolelor referitoare la
partea de automatizare a regulamentului de functionare a instalatiei, precum si la efectuarea
verificarilor la care trebuie supusa instalatia de automatizare inainte de pornirea instalatiei
tehnologice.
Prezentarea punctelor de comanda
Supravegherea si conducerea procesului tehnologic este prevazut a se realiza de la PCS-ul
central, procesul se va urmari de la camera centrala in care se va monta acesta.
Echipamentele sunt montate in asa fel incat sa existe un acces direct de pe platforme, scari sau
pasaje permanente.
Prezentarea echipamentelor de automatizare
a) Din punct de vedere al semnalelor utilizate, echipamentele sunt de tip electronic, cu
semnal unificat 4...20 mA si de tip contact pentru semnalizari si comenzi.
b) Din punct de vedere al modului de prelucrare a semnalelor, echipamentele sunt de tip:
- Analogic pentru circuite de masura;
- De tip releu pentru semnalizari comenzi;
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
21 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
22 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
23 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
24 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
25 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
26 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
b)
lor;
Amplasarea instalatiei:
pozitia si utilizarea fiecarui utilaj tehnologic;
procesul din fiecare conducta;
utilitatile si scopul de utilizare din fiecare conducta;
pozitia si scopul tuturor armaturilor;
pozitia fiecarui regulator, a fiecarui robinet de reglare si a fiecarei diafragme si destinatia
c)
Dispozitive de siguranta:
Presiunea si temperatura de lucru maxim admisa a fiecarei parti din instalatie;
Presiunea de reglare a tuturor supapelor de siguranta;
Valori de reglare a robinetelor si a regulatoarelor de presiune;
Conditii de actionare a dispozitivelor de alarma si deconectare;
Modul de functionare al robinetelor de reglare in lipsa aerului;
Semnele de foc si avarie;
Instructiuni de siguranta;
Pozitia si modul de utilizare a aparatelor de prim ajutor.
d) Instructiuni de functionare:
Instructiuni pentru operare PSI si NTS pe operatii si aparate, afisate la loc vizibil;
Registrul de blinde;
PAGINA
27 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
Prevederi generale
Supapele de siguranta vor fi verificate cu atentie, se verifica de asemenea daca au fost bine
conectate toate aparatele de masura si reglare, dispozitivele de alarma si legaturile electrice.
Racordurile pentru materiile prime si utilitati vor fi verificate atat in cadrul instalatiei cat si in
afara ei.
Vor fi verificate conductele care pleaca din instalatie pana la consumator.
Se va completa dotarea cu stingatoare, furtune de incendiu, lazi cu nisip, galeti, lopeti, etc.
Se pun in functiune avertizoare de incendiu. Se verifica daca exista echipamente de combatere
a incendiilor in conformitate cu normele de dotare.
Se va verifica daca dispozitivele fixe pentru montarea aparatelor de ridicat sunt in stare de
functionare si daca au fost autorizate.
Se va verifica legarea la pamant a tuturor aparatelor tehnologice, a constructiilor metalice, a
conductelor si se va verifica daca rezistivitatea corespunde cu cea din norma.
Prevederi specifice:
a) Utilaje
Skidul LTS este o instalatie compacta a carui constructie implica structura metalica, montaj
utilaje, montaj conducte care va fi realizat direct in uzina constructoare.
Dupa ansamblarea skidului pe santier vor fi reluate anumite probe care vor fi considerate
necesare.
b) Conducte si armaturi
Se urmaresc legaturile de conducte in special legaturile de conducte dintre skid si celelalte
functionalitati (sursa de agent de racire, sistemul de conducte de aerisire, etc.) conform
schemei de legaturi. Se vor verifica conductele la imbinari pentru a se asigura ca blindele oarbe
au fost indepartate, ca suprafetele imbinarilor si tipul garniturilor sunt conforme proiectului.
Se vor lasa blindele oarbe numai pe timpul cat se fac pregatirile pentru pornire.
Se verifica daca toate conductele la care este conectat skidul LTS au fost spalate, suflate si
predate conform normativelor tehnice precum si daca sunt corect legate in fluxul tehnologic,
daca legaturile pentru pornire au fost executate si au posibilitatea de a fi inchise cand se va
trece la functionarea normala.
Se verifica toate liniile de produse la care este conectat skidul LTS
- daca au pungi sau puncte joase si daca acestea au posibilitatea de scurgere.
- daca conductele prevazute izolate s-au izolat.
- daca conductele de evacuare in atmosfera sunt executate cu pantele prevazute
prin proiect, daca sunt in stare de functionare si anume: daca sunt curate, daca nu
sunt deschise la vreun racord, daca au fost probate si suflate, daca supapele de
siguranta au fost probate si reglate corespunzator.
Se verifica daca toate conductele tehnologice exterioare au fost probate, spalate, scurse in
punctele cele mai joase si suflate cu aer si daca au fost legate corespunzator la limita skidului.
O atentie deosebita se va acorda folosirii garniturilor si a prezoanelor prevazute prin proiectul
general al instalatiei.
Prezinta un pericol deosebit folosirea altor armaturi, fitinguri, garnituri, ringuri, prezoane, decat
cele prevazute in documentatie, nu sunt admise modificari pe utilaje, conducte, aparate si
schimbari de armaturi si materiale fara avizul producatorului instalatiei.
c) Sisteme de automatizare
A se vedea cap. 3, pct. 3.5 al Manualului de operare cu privire la sistemele de masura si control
d) Instalatii electrice
Inainte de pornirea instalatiei electrice este necesara verificarea acesteia, pentru a se stabili
daca lucrarile de reparatie si revizie s-au executat conform proiectului si normelor in vigoare.
Verificarea instalatiei si pregatirea pentru pornire cuprinde:
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
28 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
29 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
R QxT
x
3,6 M
unde
Pentru aceasta instalatie rata pierderilor este recomandata intre 10-5 10-6 l x bar/sec.
Asigurarea utilitatilor la skidul LTS
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
30 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
Se va verifica functionarea unitatii adiacente (compresor) care asigura agentul termic necesar
pentru a doua treapta de racire.
Suflarea instalatiei cu aer urmata de inertizare
Inainte de a se introduce gaze in sistem, toate vasele si conductele trebuie sa fie suflate cu aer
uscat.
In cazul acestei instalatii se recomanda utilizarea aerului uscat care are punctul de roua -40C.
Aerul tehnic este furnizat de la statiile de utilitati din zona. Legatura la o anumita conducta sau
echipament se face prin furtun temporar;
Dupa suflarea instalatiei cu aer uscat se face inertizarea cu azot din butelii.
PORNIREA SKIDULUI LTS DUPA OPRIRILE PLANIFICATE, REVIZII, REPARATII SAU
OPRIRI DE LUNGA DURATA
In cazul opririlor planificate, reviziilor, reparatiilor sau a opririlor de lunga durata, pornirea
skidului LTS se face dupa terminarea lucrarilor pregatitoare expuse in cadrul capitolului 3.5.
La pornire se vor respecta toate instructiunile de protectia muncii si PSI de care se tine cont in
exploatarea normala.
Instructiunile din acest capitol, valabile si pentru cazul primei puneri in functiune, se refera si
sunt valabile si la porniri dupa opriri planificate ale instalatiei, revizii, reparati sau dupa opriri de
lunga durata. Cu aceasta ocazie se verifica instalatia inainte de pornire, respectiv:
1. Executia instalatiei, conform documentatiei si notelor de santier;
2. Starea tehnica a utilajelor, echipamentelor electrice si AMC;
3. Autorizare I.S.C.I.R. (unde este cazul), reglajul dispozitivelor de siguranta, atestarea prin
buletine de analiza a afectuarii probelor hidraulice si a controlului sudurilor conductelor;
4. Atestarea privind puterea nominala, curentul de pornire, rezistenta de izolatie pentru fiecare
consumator electric;
5. Atestarea prin buletine de analiza a rezistentei prizelor de pamant si pentru cablurile de
joasa tensiune;
6. Atestarea pregatirii profesionale de protectia muncii si PSI pentru personalul de exploatare
al utilizatorului final;
7. Intocmirea si aprobarea programului de pornire.
8. Instalatia nu va fi pusa in functiune fara existenta urmatoarelor documente:
a. Proces verbal privind probele hidraulice ale utilajelor si conductelor;
b. Proces verbal privind verificarea, reglarea aparatelor si instalatiilor de masura control si
automatizare;
c. Proces verbal privind verificarea instalatiilor electrice de forta, iluminat si legare la
pamant;
d. Proces verbal privind verificarea dotarii cu echipament de prevenire si combaterea
incendiilor si buna functionare a acestora;
e. Proces verbal privind verificarea dispozitivelor de protectia muncii si tehnica securitatii
a echipamentului de protectia muncii si insusirii instructajului NTS de catre personalul
de exploatare al utilizatorului final;
f.
Regulamentul de functionare al skidului, exploatarea, controlul, oprirea si modul de
rezolvare al deranjamentelor si accidentelor, care se pot produce;
g. Instructiunile de protectia muncii pentru locul de munca respectiv;
h. Atributiile fiecarui post (loc) de munca;
i.
Instructiunile de prevenire si combatere a incendiilor;
j.
Proces verbal privind scolarizarea si examinarea personalui de operare;
k. Fisa regimului tehnologic de exploatare, cuprinzand temperaturi, presiuni, debite,
nivele, precum si analiza gazului de sonda ce va fi prelucrat;
l.
Schema de conducte si automatizarea skidului;
m. Proces verbal cu reglarea supapelor la presiunile prescrise;
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
31 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
n.
o.
Cartile utilajelor;
Fisele de instructaj NTS ale personalului de exploatare al utilizatorului final cu
instructajul special efectuat pentru punerea in functiune.
PAGINA
32 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
l)
Se verifica daca robinetul de pe iesirea agentului termic din schimbatorul 312-E-001 sa fie
inchis.
m) Se face linia de agent termic de la schimbatorul 312-E-001 la compresorul de agent de
racire (200-RF-001-ECQ3A-CI).
n) Se verifica daca robinetul de intrare a gazului in separatorul 313-V-001 este inchis.
o) Se face linia de la schimbatorul 312-E-001 la separatorul 313-V-001 (150-GN-007-ACQ3ACI).
p) Se verifica daca robinetul de pe iesirea gazului din separator este inchis.
q) Se face linia de gaz de la separator, la 311-E-001 (150-GN-009-ACQ3A-CI) si de la 311-E001 spre unitate de flash unit.
r) Se verifica daca robinetul de pe linia de lichid la iesirea din separator este inchis.
s) Se face linia de iesire lichid de la separatorul 313-V-001 la unitatea flash unit (50-PC-001ECQ3A-CI).
t) Se verifica daca toate robinetele de aerisiri, purjari si scurgeri de pe toate utilajele sunt bine
inchise.
u) Se verifica daca toate robinetele de pe liniile de by-pass a gazului sunt bine inchise.
v) Dupa terminarea verificarilor se trece la pornirea instalatiei dupa cum urmeaza:
Se deschid treptat robinetele de pe admisia gazului in filtre si la intrarea in
schimbatoare.
Se deschid treptat robinetele de pe admisia gazului in schimbatoarele de caldura.
Se deschid treptat robinetele de admisia a agentului termic la schimbatorul 312-E-001 si
se anunta operatorul de la compresorul de agent de racire.
Se deschide treptat robinetul de intoarcere a agentului termic in unitatea de racire.
Se deschid treptat robinetele la intrarea si la iesirea gazului din separatorul 313-V-001.
Se deschide treptat robinetul de pe lichid la iesirea din separatorul 313-V-001 si se
anunta operatorul de la unitatea flash unit .
Se anunta unitatea centrala ca poate incepe livrarea gazului catre Skidul LTS.
Se consemneaza ora inceperii livrarii gazului si debitul de gaz.
A3. Operatiile din timpul operarii Skidului LTS
a) Se verifica periodic daca operatia decurge normal, fara vibratii, zgomote anormale, scurgeri,
etc. si se controleaza periodic starea echipamentului, legaturilor de conducte, etc.;
b) Se urmaresc la PCS urmatorii parametri:
I.
Admisia si filtrarea gazului
Punctul de roua al gazului indicat de 31-WDPIT-001 la PCS si transmisa la SIS. In cazul
in care se atinge valoarea de -26C, se alarmeaza ca admisia gazului in skid este
neconforma;
In cazul in care temperatura gazului este sub punctul de roua indicat, se pot acumula lichide
in filtru care impreuna cu suspensiile solide pot infunda filtrul.
Temperatura gazului la intrarea in Skidul LTS. Valoarea este indicata la PCS de 31-TI001 si transmisa la SIS. In cazul in care valoarea temperaturii atinge 35C, se
alarmeaza ca gazul livrat este neconform.
Se urmareste caderea de presiune pe filtrele 310-F-001A si 310-F-001B cu
traductoarele de presiune diferentiala 310-PDT-001 si respectiv 310-PDT-002.
In momentul in care pe oricare din cele doua filtre se atinge valoarea de 12 kPa, inseamna
ca filtrul respectiv este infundat, se alarmeaza si se vor lua masurile necesare pentru
schimbarea cartusului filtrant.
Se anunta unitatea centrala de aceasta pentru a micsora debitul de gaz livrat la skid pana la
schimbarea cartusului.
Se urmareste temperatura la iesirea gazului din filtre cu 31-TI-002.
Suplimentar pentru buna functionare se vor inspecta periodic urmatoarele aparate de
temperatura si presiune locale montate pe filtre.
310-PG-001
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
33 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
310-PG-002
310-TG-001
310-TG-002
Presiunea gazului dupa iesirea din filtre se masoara cu 31-PG-002.
Se recomanda ca operatiile de verificare de catre personalul de exploatare al utilizatorului final
a aparaturii locale sa fie facuta la cel mult 2 h in timpul zilei, iar noaptea de cel putin de 3 ori pe
schimb.
Rezultatul inspectarii va fi consemnata in registrul de operare.
Este posibil ca in timpul operarii sa se acumuleze lichid, apa cu impuritati in filtre. De aceea se
recomanda ca la prima pornire sa se goleasca periodic filtrele prin ventilele din partea de jos.
II. Racirea gazului in schimbatorul 311-E-001 (prima treapta de racire)
In prima treapta de racire in schimbatorul 311-E-001, gazul este racit pana la temperatura de
14C.
Se urmaresc la PCS urmatorii parametri:
Temperatura gazului rece utilizat ca agent termic care vine de la separatorul 313-V-001,
indicata la PCS cu 31-TI-003. Valoarea admisibila este mai mica de -20C. Cand se
atinge aceasta valoare, se vor lua masuri pentru micsorarea debitului de agent rece
care vine de la compresor, la schimbatorul 312-E-001.
Presiunea diferentiala pe circuitul de gaz este indicata la sistemul PCS de 311-PDI-002.
Valoarea maxima admisibila este 20 kPa. Daca aceasta valoare este atinsa, se
considera ca s-au format criohidrati. Se opreste temporar admisia de gaz si se
desfunda tevile folosind racordul pentru injectia de metanol.
Presiunea diferentiala pentru agentul termic este indicata la sistemul PCS de 312-PDI002. Valoarea maxima admisibila este 20 kPa. Daca aceasta valoare este atinsa, se
considera ca s-au format criohidrati. Se opreste temporar admisia de gaz si se
desfunda tevile folosind racordul pentru injectia de metanol.
Local se urmareste temperatura si presiunea pe cele doua circuite. Verificarea
temperaturii si presiunii locale se face periodic la cel mult 2 h pe schimb ziua si de cel
putin de 3 ori pe schimb noaptea.
Pe conducta de iesire a gazului racit si purificat din circuitul rece al schimbatorul 311-E-001
(150-GN-010-ACQ3A-CI) catre unitatea flash unit, se poate monta optional aparatul de
masurare a punctului de roua pe hidrocarburi care transmite la PCS catre bucla de semnalizare
31-HDPIT-001.
Punctul de roua pe hidrocarburi al gazului trebuie sa aiba valoarea de -7C care indica buna
functionare a procesului tehnologic.
Rezultatul va fi consemnat in registrul de operare.
III. Racirea gazului in schimbatorul 312-E-001 (a doua treapta de racire)
In a doua treapta de racire in schimbatorul 312-E-001, gazul este racit pana la temperatura de 7C. Agentul de racire folosit este propan comprimat cu temperatura de -14C .
Se urmaresc la PCS urmatorii parametri:
Temperatura gazului rece care vine de la schimbatorul 311-E-001 este indicata la PCS
de 31-TI-002. Valoarea maxima admisibila este +15C. Cand se atinge aceasta valoare,
se vor lua masuri pentru cresterea debitului de agent rece (propan) care vine de la
compresor la schimbatorul 312-E-001.
Presiunea diferentiala pe circuitul de gaz indicata la tablou de 312-PDI-001. Valoarea
maxima admisibila este 40 kPa. Daca aceasta valoare este atinsa, se considera ca s-au
format criohidrati. Se opreste temporar admisia de gaz si se desfunda tevile folosind
racordul pentru injectia de metanol.
Presiunea diferentiala pentru agentul termic (propan) ete indicata la tablou de 312-PDI002. Valoarea maxima admisibila este 40 kPa. Daca aceasta valoare este atinsa, se
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
34 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
Local se urmareste temperatura si presiunea pe cele doua circuite (de gaz si agent termic).
Verificarea temperaturii si presiunii locale se face periodic la cel mult 2 h pe schimb ziua si de
cel putin de 3 ori pe schimb noaptea de catre personalul de exploatare a utilizatorului final.
Rezultatul va fi consemnat in registrul de operare de catre personalul de exploatare al
utilizatorului final.
IV. Separarea gazului de produs condensat
Operatia se face in separatorul LTS 313-V-001. In acest utilaj se introduce fluxul de gaz
amestecat cu produs condensabil rezultat din treapta a doua de racire.
Lichidul se aduna in partea de jos a separatorului de unde este trimis prin intermediul
robinetului de reglare 31-LCV-001 la unitatea flash, iar gazul iese prin partea superioara a
utilajului si este dirijat in prima treapta de racire, unde cedeaza caldura gazului proaspat, apoi
este trimis in unitatea flash.
Inainte de a fi evacuat din separator, gazul trece prin demister care retine picaturile de lichid.
Se urmaresc la PCS urmatorii parametri:
Temperatura gazului din separator este transmisa PCS prin intermediul buclei de
reglare 313-TIC-001, functie de aceasta temperatura este inchis sau deschis robinetul
de reglare a debitului de agent de racire 31-TCV-001 montat pe conducta de iesire, 200RF-002-ECQ3A-CI, a agentului de racire (propan) din schimbatorul 312-E-001.
Presiunea din separator este transmisa de traductorul de presiune 31-PT-005 si
indicata la PCS de bucla de indicare/semnalizare 31-PIC-005 cu alarme de minim si
maxim. Valoarea minima este 27 bar, iar valoarea maxima de 60 bar.
Nivelul maxim de lichid in separator este semnalizat in sistemul PCS de bucla de
semnalizare 313-LAHH-001. La atingerea nivelului maxim de lichid, se deschid ventilele
manuale de golire montate pe conducta spre unitatea flash unit, (conducta 50-CD-008ECQ3A-CI).
Nivelul normal de lichid in separator este reglat de sistemul PCS prin intermediul
traductorului de nivel 313-LT-001 care actioneaza ventilul 31-LCV-001 de pe conducta,
50-PC-002-ECQ3A-CI, care transmite lichidul la unitatea flash unit.
Pentru situatii de urgenta, (nivelul minim de lichid in separator) este montat in PCS
indicatorul 313-LALL-001 care inchide ventilul 31-SDV-001 la atingerea nivelului minim
in separator. Valoarea este trimisa la SIS si in cazul in care nivelul de lichid in
separatorul 313-V-001 atinge 50 mm, se inchide automat ventilul 31-SDV-001 (de iesire
din separatorul trifazic).
De asemenea utilajul este prevazut cu aparate de masura de presiune si temperatura
care dau indicatii locale.
Separatorul 313-V-001 este protejat la suprapresiune cu supapa 313-PSV-001 setata la 61,4
barg si este prevazut cu ventile de scurgeri si aerisiri.
Verificarea temperaturii si presiunii locale se face periodic la cel mult 2 h pe schimb ziua si de
cel putin de 3 ori pe schimb noaptea.
Rezultatul va fi consemnat in registrul de operare de catre personalul de exploatare al
utilizatorului.
B. RECOMANDARI DE LA PORNIREA SKIDULUI LTS
Atat la prima pornire cat si in operare normala se recomanda a se respecta urmatoarele:
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
35 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
36 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
37 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
38 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
39 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
Masuri:
Se opreste alimentarea cu gaz a skidului;
In instalatiile care furnizeaza gaz spre skid se vor lua masuri ca temperatura gazului sa
scada sub +35C;
Se va relua admisia gazului la skid, cand temperatura este < +35C;
Presiunea gazului in reteaua de gaz dupa filtru si la iesirea din schimbatorul 312-E-001
depaseste valoarea de 51 bar;
In mod normal, acest lucru nu este posibil decat in cazul in care si la alimentare
presiunea depaseste 51 bar;
Masuri:
Se va urmari in permanenta ca presiunea la alimentarea gazului in skid sa nu
depaseasca 51 bar;
Formarea de criohidrati pe circuitele de agent termic (propan);
Formarea criohidratilor este indicata de cresterea presiunii diferentiale pe circuit;
Masuri:
Se va face injectie de metanol in circuitul respectiv;
Formarea criohidratilor pe circuitele de gaz;
Masuri:
Se va face injectie cu fluid de curatare (metanol);
Scaderea nivelului de lichid in separatorul 313-V-001;
Masuri:
Daca se intampla acest eveniment, semnalizatorul 313-LALL-001 inchide automat
ventilul 31-SDV-001 de pe conducta de lichid de la vasul separator la separatorul
trifazic.
Depasirea nivelului maxim de lichid in separatorul 313-V-001;
Masuri:
Se deschid ventilele manuale de golire montate pe conducta spre unitatea flash.
Situatii accidentale (avarii)
Principalele avarii care pot aparea in exploatarea skidului LTS pot fi generate in special de
neetaseitatile la utilaje si conducte.
De regula, aceste scapari nu pot forma nori explozivi in conditiile in care personalul operator
sau instalatie de detectare gaze sesizeaza scaparea si se iau masuri imediate pentru
remedierea defectiunii.
Daca totusi aceasta situatie genereaza cantitati mari de gaze in zona skidului, vor fi luate
urmatoarele masuri:
- Va fi anuntat seful de instalatie, care va organiza si conduce operatiile ce se impun a fi
efectuate.
- Vor fi indepartate persoanele a caror prezenta in zona nu este indispensabila.
- Vor fi acoperite cu folie de plastic si nisip gurile de canalizare din zona.
- Se asigura eliminarea din zona a oricaror surse de aprindere.
Vor fi executate cu calm si cu atentie toate operatiile de remediere specifice cazului aparut.
In cazul cand se constata ca s-a produs o scurgere importanta de gaz, pe langa masurile
mentionate mai sus se vor realiza si urmatoarele:
anuntarea conducerii schelei si formatiei PSI a unitatii;
paza in zona de avarie;
permanent se urmareste concentratia de gaze in atmosfera si se procedeaza la
accelerarea dispersiei acestora in aer, folosind de exemplu jeturi de apa proiectate cu
furtunele de incendiu alimentate de la hidrantii din zona;
se vor lua orice alte masuri care se considera a fi necesare si impuse de situatie;
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
40 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
in scopul unor interventii eficiente, operatiile mai dificile trebuie simulate in cadrul instruirii
personalului si fixate atributiile pe oameni.
Utilizatorul final va intocmi propriile planuri de actiune in caz de avarie/urgenta conform
reglementarilor legale in vigoare in care sa includa instructiunile din manualul de operare al
skidului LTS.
Avarii majore
Avariile majore cu scaparea unei cantitati mari de gaze, pot aparea in cazul skidului LTS din
urmatoarele cauze:
- Nerespectarea parametrilor de operare pentru care a fost proiectata instalatia si skidul
LTS;
- Neefectuarea inspectiilor periodice, conform reglementarilor legale in vigoare ale
echipamentelor;
- Neefectuarea lucrarilor de revizie, reparatie si intretinere ale echipamentelor;
- Neurmarirea atenta de operator a semnalizarilor de detectie si a aparitiei
neetanseitatilor;
- Nedeschiderii supapelor de siguranta la presiunea de setare maxima admisa (61,4
bar);
- Neefectuarea inspectiilor periodice, conform reglementarilor legale in vigoare ale
echipamentelor;
- Avarii majore la utilaje ajungandu-se pana la explozia vasului;
- Erori umane grave;
In cazul unei avarii majore, pot aparea cantitati mari de gaze in zona skidului si pot exista
patru posibilitati de evolutie a incidentului, dupa cum urmeaza:
A. Scaparile de gaze nu se aprind
B. Scaparile de gaze se aprind instantaneu;
C. Scaparile de gaze se aprind dupa un interval de timp, producandu-se explozia norului
de gaz format in aer liber;
D. Explozia unuia dintre vase sau schimbatoare.
Procedurile de interventii in aceste cazuri sunt prezentate mai jos:
A. Scaparile de gaze nu se aprind
In varianta unui incident major - scapari masive de gaze fara aprinderea acestora. Principalele
momente sunt:
- T0 - scapare masiva de gaz;
- T1 - T0 - semnalizarea de catre detectoarele de gaze a depasirii pragului de 50 % din
valoarea LIE (limita inferioara de explozie);
- T2 - inchiderea alimentarilor cu gaze de sonda si a traseelor produselor finale prin
robinetele de emergenta de la sistemele de interblocare;
oprirea automata a motoarelor pompelor si compresoarelor din zona;
alarmarea seviciului de pompieri propriu pentru situatii de urgenta si a personalului de
conducere;
alarmarea tuturor salariatilor prin semnale sonore;
- T3 - intrarea in dispozitiv a serviciului propriu pentru situatii de urgenta cu autospecialele
din dotare;
- T4 - intreruperea alimentarii cu energie electrica a echipamentelor amplasate pe directia
de deplasare a norului de gaze si oprirea oricaror activitati in zonele respective;
- T5 - realizarea dispozitivelor de interventie pentru racire cu apa si realizarea perdelelor de
apa pentru izolarea completa a zonei;
- T6 - alarmarea Serviciului de Ambulanta din localitate si Inspectoratului pentru Situatii de
Urgenta a jud. Bacau;
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
41 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
T7- verificarea intrarii in functiune a pompelor de apa incendiu prin comanda automata si
dupa caz, pornirea manuala pentru a se asigura debitele de apa necesare racirii si
dispersiei norului;
- T8 - evacuarea tuturor persoanelor straine din statia de tratare produse petroliere si a
personalului fara atributii de interventie;
oprirea traficului in zona si dirijarea acestuia pe cai ocolitoare daca norul de gaze
are directia spre drumul public ;
- T9 - intrarea in dispozitiv a fortelor ISU Bacau pentru asigurarea dispersiei norului de gaze;
sosirea Serviciului de Salvare;
- T10 - exista doua variante:
a) in ipoteza izolarii si stoparii scaparilor de gaze, prin interventia personalului si
pompierilor, se trece la verificarea zonei cu detectoarele de gaze si in situatia in care nu
se constata concentratii periculoase se inlatura efectele incendiului si se intervine pentru
remedierea defectiunii;
Se recomanda sa se utilizeze apa pulverizata pentru dispersarea gazelor in atmosfera.
b) daca nu s-a reusit oprirea scaparilor de gaz se asigura:
- evacuarea intregii zone pe o raza de 400 m de la limita incintei schelei petroliere;
- continuarea actiunilor de interventie pentru dispersia gazelor si preantampinarea
aprinderilor;
- supravegherea modului de deplasare a gazelor si dupa caz se iau alte masuri pentru
dispersia norului si izolare, pe baza deciziei conducatorului interventiei;
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
42 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
43 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
Mentiune: Cauzele avariilor majore cu scapari mari de gaz au fost prezentate mai sus, dar
explozia unui vas este un caz special si de aceea s-a considerat oportun reprecizarea
cauzelor pentru punctul D.
Procedura care trebuie urmata in acest caz este:
- T0 - inchiderea alimentarilor cu gaze de sonda a schelei Poduri si a traseelor produselor
finale prin robinetele de emergenta de la sistemele de interblocare;
oprirea automata a motoarelor pompelor si compresoarelor din zona ;
alarmarea seviciului de pompieri propriu pentru situatii de urgenta si a personalului de
conducere;
alarmarea tuturor salariatilor prin semnale sonore;
evacuarea intregii zone pe o raza de 400 m de la limita incintei;
- T1 - intrarea in dispozitiv a serviciului propriu pentru situatii de urgenta cu autospecialele
din dotare;
- T2 - intreruperea alimentarii cu energie electrica a echipamentelor amplasate pe directia
de deplasare a norului de gaze si oprirea oricaror activitati in zonele respective;
- T3 - realizarea dispozitivelor de interventie pentru racire cu apa si realizarea perdelelor de
apa pentru izolarea completa a zonei;
- T4 - alarmarea Serviciului de Ambulanta din localitate si Inspectoratului pentru Situatii de
Urgenta a jud. Bacau;
- T5- verificarea intrarii in functiune a pompelor de apa incendiu prin comanda automata si
dupa caz, pornirea manuala pentru a se asigura debitele de apa necesare racirii;
- T6 - evacuarea tuturor persoanelor fara atributii de interventie din statia de tratare produse
petroliere;
oprirea traficului in zona si dirijarea acestuia pe cai ocolitoare daca norul de gaze
are directia spre drumul public;
- T7 - intrarea in dispozitiv a fortelor ISU Bacau pentru asigurarea dispersiei norului de gaze;
sosirea Serviciului de Salvare;
Daca nu s-a reusit oprirea scaparilor de gaz si incendiul se manifesta in continuare, se
asigura:
- T8 - continuarea actiunilor de interventie pentru racire pana la epuizarea zestrei de gaze;
Si in aceasta ipoteza se va urmari evolutia incendiului, actionandu-se intens pentru racire
pentru a se preintampina fenomenele negative.
Dupa epuizarea zestrei de gaze se trece la operatiunile de remediere.
- scaparea se considera instantanee si nu cu un anumit debit;
- compozitia norului se presupune uniforma la amestecul vapori de gaze aer, la
valoarea medie a limitei inferioare respectiv superioare de explozie;
- gazele iesite in exterior formeaza imediat un nor de gaz;
4.4. OPRIREA INSTALATIEI
OPRIREA NORMALA
Avand in vedere modul de functionare, se realizeaza oprirea alimentarii cu gaze de sonda la
solicitarea conducerii societatii care este utilizatorul final al skidului LTS, functie de cantitatea
de gaz disponibila pentru procesare.
La oprirea instalatiei se va respecta urmatoarea procedura:
a) Se anunta dispeceratul central sa opreasca alimentarea gazului de la unitatea centrala.
b) Dupa oprirea alimentarii gazelor, se opreste alimentarea filtrelor 310-F-001A si 310-F001B.
c) Se inchide robinetul de distributie a gazului catre racitorul 311-E-001.
d) Se urmareste nivelul de lichid din separatorul 313-V-001 si cand ajunge la minim, se
inchide robientul 31-LCV-001.
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
44 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
45 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
Separator LTS
10
Tag
310-F001A
310-F001B
311-E001
312-E001
312-V001
Model/
Cod Producator
Producator
CONFIND
4348-00
CONFIND
4394-00
CONFIND
4394-00
VAHTERUS
Finlanda
VAHTERUS
Finlanda
Model PSHE-7HH-334/1/1
4340-00
Indicator magnetic
de nivel
FIDELIS(HADRO)
D63
Manometru
BADOTHERM
BDT20
Trasmiter presiune
diferentiala
SIEMENS
Transmiter
presiune
SIEMENS
Carte tehnica
Model PSHE-7WH-268/1/1
CONFIND
11
Termometru
BADOTHERM
12
Transmiter
temperatura
HONEYWELL
Transmiter temperatura
STT830-25H-56
13
Level switch
VEGA
VEGASWING 63
PAGINA
46 of/din
76
Documentatie
Carte tehnica
vas
Carte tehnica
vas
Specificatie
tehnica
Specificatie
tehnica
Carte tehnica
vas
Indicator
magnetic de
nivel
Instructiuni de
operare
Specificatie
tehnica
Instructiuni de
utilizare
Conform SR EN
837/1-98
Suport tehnic
(CD)/2012
Suport tehnic
(CD)/2012
Specificatie
tehnica
BDTW232 bar
stock
thermowell
Instructiuni de
montare si
utilizare pentru
termometre cu
bimetal
Conform SR EN
13190
Specificatie
tehnica
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
Nr.
Echipament
Crt.
14
Transmiter de
nivel
15
Transmiter punct
de roua si
temperatura ptr
apa
Tag
Producator
Model/
Cod Producator
VEGA
VEGAPASS 81
GE
HIGROPRO
16
Transmiter punct
de roua si
temperatura ptr
hidrocarburi
AMETEC
18
Cutie de joctiune
Ex-e
INTEC
AUTOMATIZARI
SRL
19
Cutie de joctiune
Ex-i
INTEC
AUTOMATIZARI
SRL
Documentatie
Traductor
electronic de
nivel
Specificatie
tehnica
Specificatie
tehnica,
instructiuni de
montaj
Instructiuni de
folosire si
montaj, schema
electrica si de
montaj
Specificatie
tehnica,
instructiuni de
montaj
Specificatie
tehnica,
instructiuni de
montaj
Operatiile de intretinere (de ex.: inlocuiri de robinete, garnituri, armaturi diverse, etc.) se vor
efectua numai in baza instructiunilor de lucru, intocmite de utilizatorul final.
Interventiile pentru reparatii, remedieri sau revizii se vor executa pe baza de permis de lucru in
care vor fi mentionate toate masurile necesare executarii lucrarilor in conditii de securitate
Pentru a fi valabil permisul de lucru trebuie semnat de toate organele in drept. Pentru locurile
de munca unde exista pericol de incendiu si explozie lucrarile vor putea incepe numai in baza
permisului lucru pentru interventii si reparatii cu foc.
Pe categorii de echipamente se vor respecta urmatoarele :
Utilajele vor lucra numai la parametri tehnici pentru care au fost proiectate.
Se va respecta strict tehnologia prevazuta pentru utilaje si sunt interzise orice modificari ale
procesului tehnologic.
Sunt interzise improvizatiile de orice natura in functionarea utilajelor si uneltelor care au
defectiuni sau care nu sunt prevazute cu toate dispozitivele de protectie necesare asigurarii
securitatii muncii.
Interventiile la utilaje se vor face respectand urmatoarele :
Utilajele respective vor fi racite, aduse la presiunea atmosferica, golite, curatate si ventilate la
interior de orice urma de substanta toxica, inflamabila, exploziva, etc., luand masuri pentru
determinarea analitica a noxelor, acolo unde este cazul.
Se vor deconecta si izola toate legaturile tehnologice, pentru evitarea patrunderii accidentale in
echipamentul respectiv a unor substante sau gaze si vapori.
Se vor bloca prin blindare toate conductele utilajului respectiv, acolo unde exista pericol de
neetansare sau patrundere accidentala, legaturile se vor deconecta si izola, se vor pune
placute avertizoare.
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
47 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
48 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
49 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
deschidere. Ventilele care nu permit trecerea cand sunt putin deschise se inchid la loc si
situatia se comunica sefului de sectie.
Tijele ventilelor se vor unge.
Nu este permisa esaparea unor cantitati mari de lichide fierbinti sau gaze in atmosfera, datorita
pericolului de foc. Daca trebuie sa se destinda gaz in aer liber atunci aceasta se va face incet.
Partile instalatiei care contin produse lichide volatile, cand sunt blocate, trebuie golite si
destinse.
Instalatia trebuie controlata la anumite intervale cu detectoare de gaz pentru a se constata
scaparile periculoase. Aceste surse de pericol trebuie inlaturate imediat.
Sticlele de nivel se vor mentine curate si conductele de legatura cu ele se vor tine libere.
Accesul la utilajele de la nivelele superioare este permis numai peste pasarelele si scarile
prevazute in acest scop. Cand nu exista pasarele sau scari atunci se vor folosi scari aplicabile
sau schele care corespund masurilor de protectie.
Cand se recolteaza probe ce contin apa, vasele nu trebuiesc umplute complet, spre a se evita
spargerea lor, in cazul dilatarii provocate de inghet.
Operatii de curatire si inspectie
Operatia de curatire si inspectie a utilajelor se face numai pe baza de permis de lucru cu
precizarea lucrarii care trebuie executata cu respectarea reglementarilor nationale in vigoare
Utilizatorul final al skidului LTS va tine evidenta inspectiilor, reviziilor si reparatiilor efectuate, cu
respectarea reglementarilor nationale in vigoare.
Rezidurile, depunerile rezultate, precum si pamantul imbibat cu produse petroliere vor fi
evacuate in exteriorul indiguirilor si vor fi depozitate in locuri si conditii stabilite de comisia
tehnica pentru prevenirea si stigerea incendiilor sau, in lipsa acesteia, de catre conducerea
unitatii utilizatorului final al skidului LTS, cu respectarea reglementarilor legale nationale si a
regulamnetelor interne in vigoare.
Lucrari de reparatii cu foc la skidul LTS
Efectuarea lucrariilor de reparatii cu foc la skidul LTS pot fi permise numai dupa oprirea
functionarii acestuia, purjarea si suflarea utilajelor si conductelor si oprirea la distanta a
alimentarii gazelor, cu respectarea tuturor reglementarilor nationale aplicabile in vigoare.
Este recomandabil datorita faptului ca skidul este un utilaj compact, ca lucrarile de reparatii cu
foc sa se faca numai in perioadele de revizii, aceasta fiind o garantie privind lipsa mediului
exploziv din zona.
Daca totusi aceste lucrari sunt necesare, se vor lua masurile impuse pentru evitarea aparitiei
mediului exploziv in zona, dupa cum urmeaza:
Golirea completa a utilajelor si conductelor, purjarea si suflarea acestora, precum si oprirea la
distanta a alimentarii gazelor.
Analizele probelor de gaze din utilajele afectate sa arate lipsa gazelor inflamabile;
Muncitorii sa poarte echipament de lucru si protectie, care sa nu fie imbibat cu produse
petroliere;
Se vor lua masuri corespunzatoare si in instalatiile din apropierea skidului. Daca este cazul, in
apropierea skidului se vor realiza paravane de protectie precum si perdele de abur;
In apropierea skidului se va concentra echipamentul PSI de prima interventie;
Executarea lucrului cu foc se va face in prezenta sefului de sectie si a unei echipe de pompieri;
Probele de gaze si analizele lor se vor repeta zilnic, inainte de inceperea lucrului cu foc.
Executarea lucrarilor la reparatii cu foc este permisa numai pe baza unui permis de lucru cu
foc, intocmit de utilizatorul final al skidului LTS cu respectarea tuturor reglementarilor nationale
aplicabile in vigoare.
Revizia supapelor de siguranta
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
50 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
51 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
Fisele de instructaj NTS ale personalului cu instructajul special efectuat pentru pornirea
instalatiei;
Asigurarea cu utilitati la limita instalatiei.
PAGINA
52 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
Verificarea etanseitatii
Verificarea etanseitatii va fi bazata pe formarea de basici din solutia de sapun sau detergent ce
va fi aplicata cu pensula la fiecare mbinare.
Basicile apar numai n cazul scaparii gazului inert.
Solutia de sapun trebuie sa aiba o concentratie de aproximativ 50 gr. sapun la litru de apa.
Calitatea apei si a sapunului pot afecta concentratia corecta si este necesar ca nainte de
nceperea testului de etanseitate, solutia sa fie ncercata.
Adaugarea a 5 gr. de glicerina la litrul de apa mareste eficienta n formarea basicilor cand sunt
prezente scapari de gaz inert.
Lipirea de banda de hartie adeziva (gumata) n jurul circumferintei la toate flansele si
practicarea unei gauri de diametru mic orientata corespunzator, usureaza mult operatia de
verificare, solutia de sapun urmand a fi aplicata numai la suprafata gaurii.
Acceptarea testului de etanseitate se bazeaza pe absenta oricaror scapari respectiv presiunea
pe sistem ramane practic constanta n timpul testului (fara adaus de gaz inert din afara).
Se vor lua n considerare corectii datorita schimbarii temperaturii (daca va fi cazul).
Sensibilitatea testului
Dupa ANSI B/ASME codes, la testul cu solutie de sapun formarea basicilor are loc la scapari de
cel putin 1/1000 Ncm3/sec. sau 3,6/1000000 Nm3/h pentru o mbinare.
Daca sistemul are de exemplu 1000 mbinari unde pot apare scapari, pierderea minima este de
3,6/1000 Nm3/h. O astfel de pierdere este imposibil de detectat de catre manometre.
NOTA:
nainte de a unge cu solutie de sapun, trebuie verificat daca nu sunt scapari mari care pot fi
detectate cu mana sau prin zgomot, deoarece scaparile mari nu formeaza basici.
Testul de etanseitate trebuie efectuat la o temperatura ambianta de + 15oC sau mai mare. n
cazul unor temperaturi ambiante mai joase, trebuie luate masuri de ncalzire ale sistemul
nainte de nceperea testului.
d) Testele de etanseitate vor fi incluse n procese-verbale care vor indica data, ora,
echipamentele si conductele incluse n test, fluidul folosit, presiunea de testare, temperatura,
rezultatul testului si cine le-a executat.
Testul de etanseitate al sistemelor ce deservesc compresorul
Procedurile de efectuare ale testului de etanseitate pentru compresor si conductele aferente nu
difera de cele ale instalatiei din care face parte si care au fost descrise la capitolul respectiv.
IMPORTANT: nainte de ridicarea presiunii n sistem este necesar sa se porneasca sistemul de
etansare al compresorului si sistemul de ungere deoarece curgerea gazelor poate provoca
nvartirea rotorului si deteriorarea lagarelor n absenta ungerii.
PROBELE TEHNOLOGICE PREMERGATOARE PORNIRII
Probele tehnologice premergatoare pornirii instalatiei cuprind probele tuturor aparatelor si
pompelor, la temperatura si presiune inferioare celor de regim.
Aceste probe se fac cu scopul de a se constata:
- etanseitatea aparatelor si pompelor;
- punerea la punct pe cat posibil a aparatelor de masura si control;
- etanseitatea tuturor conductelor, pompelor si utilajelor;
- verificarea daca toate circuitele sunt n buna stare de functionare;
- cunoasterea de catre personalul operator al aparatelor, pompelor, traseelor de conducte,
manevrarea robinetelor.
nainte de nceperea probelor tehnologice la instalatie, va trebui sa existe:
- Ordinul scris al conducerii pentru nceperea si exercitarea probelor tehnologice;
- Instructiunile pentru executarea probelor tehnologice si de pornire a instalatiei.
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
53 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
54 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
1
Purjarea cu azot a compresorului se face independent de purjarea instalatiei.
n timpul purjarii instalatiei, robinetele de pe aspiratia si refularea compresorului vor fi nchise.
Purjarea compresorului cu azot va decurge n felul urmator:
Se nchid robinetele ,izoland compresorul;
Se porneste sistemul de etansare al compresorului conform instructiunilor furnizorului;
Se porneste sistemul de ungere al compresorului conform instructiunilor furnizorului;
Se deschid robinetele de pe linia de evacuare;
Se monteaza linia de azot;
Se deschid robinetele de pe linia de azot;
Azotul ia locul aerului care iese prin linia de evacuare;
Se verifica, prin analize, daca n azotul evacuat continutul de O2 a scazut sub limita maxima
admisa;
La terminarea operatiei de purjare se nchid robinetele de pe liniile de azot si evacuare si se
demonteaza linia de azot .pentru a nu permite GPL sa intre n sistemul de azot.
Se deschid complet robinetele de aspiratie si refulare pentru a se realiza n sistem presiunea de
aspiratie.
Operatia de purjare cu azot se va face la orice oprire pentru interventii sau reparatii si la
reporniri dupa aceste operatii.
La trecerea pe functionare cu azot a compresorului trebuiesc facute urmatoarele operatii:
- se nchid robinetele de pe circuitul de GPL;
- se monteaza linia de azot si se deschid robinetele;
-se vor respecta toate indicatiile din instructiunile date de furnizor n ceea ce priveste pregatirea
compresorului pentru functionarea pe azot la capacitate mult mai mica decat cea normala.
La trecerea de pe functionarea pe azot la functionarea pe GPL se fac urmatoarele operatii:
- se nchid toti robinetele de pe linia de azot;
- se demonteaza linia de azot;
- se deschid robinetele de pe liniile de GPL.
PORNIREA INSTALATIEI
Prezentele instructiuni de pornire au fost ntocmite pe baza experientei in domeniu .
Verificarea pozitiei robinetelor
naintea pornirii este necesar sa se efectueze verificarea pozitiei tuturor robinetelor de pe
conductele aferente astfel:
toate robinetele de aerisire si robinetele de drenaj sa fie nchise;
toate robinetele de izolare a aparatelor de masura sa fie deschise;
Se verifica daca robinetele de pe liniile de proces sunt deschise conform schemei de operare
Pornirea instalatiei
Se solicita confirmarea ca din punct de vedere al sistemului de automatizare totul este gata
pentru pornire.
1
Se solicita confirmarea ca din punct de vedere electric instalatia este gata pentru pornire.
Se verifica ndeplinirea tuturor conditiilor de pornire.
Operatii efectuate imediat dupa pornire
Se verifica prin citiri la aparate functionarea normala a echipamentelor din schema de operare
Operatii efectuate zilnic
Se vor intocmi si completa de beneficiar conform experientei proprii
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
55 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
56 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
57 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
OPERAREA NORMALA
Se efectuiaza operatii de transvazare produse in si din depozit conform schemei de operare
respective.
Se efectuiaza operatii de transvazare produse in interiorul depozitului conform schemei de
operare respective.
PORNIRE, OPRIRE, REPORNIRE N ANOTIMPUL RECE
Personalul din instalatie va acorda o deosebita atentie utilajelor, liniilor si aparaturii AMC care
pot contine solutii apoase.
Masurile generale ce se iau n perioada friguroasa precum si pregatirile ce trebuiesc facute sunt
redate n - Norme generale de protectia muncii 2002, ed. de MMSS si MSF, Norme
departamentale de protectia muncii, editata n 1982 de Ministerul Industriei Chimice NDPMMICh si n Normele departamentale de prevenire si stingere a incendiilor n industria chimica si
petrochimica MIChP - aprobate de MICh cu Ordinul nr.138 din 11.07.1988.
Se atrage atentia n mod special, ca atat la prima pornire cat si la opriri si reporniri, daca sunt
facute n anotimpul rece, se va tine seama de urmatoarele:
Recipiente de presiune
Pentru recipiente proiectate din materiale pentru temperaturi scazute, ori de cate ori se vor crea
temperaturi mai scazute decat aceea prevazuta n proiect, trebuie respectata conditia ca
presiunea sa nu depaseasca 20 % din presiunea de proiect.
Temperatura echipamentului nu trebuie sa fie mai coborata decat
45 0C cand temperatura minima admisibila este de - 20 0C.
Conducte
Pentru conductele si armaturile proiectate din materiale pentru temperaturi scazute, nu se va
depasi presiunea de proiect si nu se va lucra la temperaturi mai scazute decat cele prevazute
n proiect.
Pompe
Se acorda o atentie deosebita la opririle pe timp rece a pompelor din instalatie care pot avea
apa precum si la circuitele aferente, scurgand bine liniile si echipamentele de care sunt legate.
SIGURANTA N FUNCTIONARE SI SECURITATEA INSTALATIEI
n Fisa regimului tehnologic, s-au indicat conditiile de lucru normale si maxime (presiunea si
temperatura de calcul).
n instalatie se pot produce abateri de la functionarea normala din diferite motive cum sunt:
- la porniri si opriri prin nerespectarea sau necorelarea secventelor de urmat sau ntarzierea la
punerea sau scoaterea din circuit a unor fluxuri;
- diminuarea sau caderea unor utilitati n timpul mersului normal
- reactii necontrolate din cauza unor dozari gresite, nerespectarea conditiilor de temperatura,
presiuni, mediu de lucru.
Din acest motiv pot aparea 2 situatii:
PAGINA
58 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
1. Depasirea presiunii si / sau temperaturii maxime admisibile (de calcul), care pune n pericol
rezistenta echipamentului.
Pentru a nu se depasi presiunea maxima de lucru (de calcul), utilajele individuale sau sistemele
(utilaje legate ntre ele prin conducte fara organe de nchidere) sunt prevazute cu supape de
siguranta.
Cum procesul tehnologic este afectat nainte de a se ajunge la deschiderea supapelor de
siguranta, operatorul va actiona manual conform instructiunilor.
n cazul depasirii temperaturii de lucru (deseori avand ca efect cresterea presiunii), masurile de
protectie sunt n mana operatorului care trebuie sa actioneze imediat pentru a nu se ajunge la
depasirea temperaturii de calcul.
7.
PAGINA
59 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
% Volume
0,3943
0,6479
91,4385
4,3609
1,8556
0,2708
0,5510
0,1586
0,1489
0,0945
0,0591
0,0123
0,0065
99,9989
1 ppm
% Fractie
molara
0,3930
0,6501
91,2879
4,2897
% Masa
g/Nm3
0,2817
0,5737
0,1687
0,1617
0,1056
0,0710
0,0165
0,0106
99,9991
0,6074
1,5785
80,8011
7,2826
4,5967
0,9033
1,8397
0,6715
0,6437
0,5021
0,3925
0,1040
0,0750
99,9981
4,9283
12,8079
655,6141
59,0903
37,2976
7,3296
14,9273
5,4488
5,2227
4,0738
3,1849
0,8438
0,6086
811,3777
1,8894
PAGINA
60 of/din
76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
0,42
0,55
-182
gaz
-165
595 1500
15.4
IIA
T1
nu 2+
gaz
-89
470
15,5
IIA
T1
fp 2+
2,1
9,6
IIA
T1
fp 2+
IIA
T1
da
Etan
0,37 1,047
Propan
0,50
i-Butan
-183
1,56
-186
<105
-42
450 1800
1,35
-145
465
-12
465
2,05
-135
-60
gaz
-1
365
n-Butan
0,56
i-Pentan
0,62 2,49
-160 <-20
29
420
0,63
-130
36
258 2400
n-Pentan
2,49
-50
13 14 15 16 17 18 19 20 21
Oprire gaz
Obs.
Haloni
Spuma antialcalina
12
Spuma chimica
11
Praf
10
Gaz inert
Clasa de temperatura
max. de suprafata, oC
Apa
Sup.
Solubilitate in apa
Inf.
Grupa de explozie
Spuma aeromecanica
Aprindere
Metan
Fierbere
Inflamabilitate
Topire
Nr.
Crt Denumirea substantei
1,5
8,5
IIA
T2
nu
1,3
7,6
IIA
T2
nu
1,3
7,8
IIA
T3
Nu -
Pag. 61 din 76
22
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
Nonan
0,66
-95
-22
69
260 1500
1,1
7,5
IIA
T3
fp 2+
0,68
3,46
-91
-4
98
220 2000
1,1
6,7
IIA
T3
fp 2+
0,70
3,86
-56,5
12
125
225 2000
0,8
6,5
IIA
T3
nu
0,718
4,4
-54
31
151
205
0,74
5,6
IIA
T3
nu 2+
13 14 15 16 17 18 19 20 21
Pag. 62 din 76
Oprire gaz
Obs.
Haloni
Spuma antialcalina
12
Spuma chimica
11
Praf
10
Gaz inert
Clasa de temperatura
max. de suprafata, oC
Apa
Sup.
Solubilitate in apa
Inf.
Grupa de explozie
Limitele de
explozie,
%val in aer la
760 mm Hg si
20oC
Spuma aeromecanica
11
n-Octan
Aprindere
10
n-Heptan
Fierbere
n-Hexan
Inflamabilitate
Topire
Nr.
Crt Denumirea substantei
Temperatura
Densitate
22
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
Mentiune: Aparitia unei surse de foc intr-o zona in care concentratia de gaze se afla intre LIE
(limita inferioara de explozie) si LSE (limita superioara de explozie) provoaca o explozie,
urmata de incendiu. In afara acestor limite, sursa de foc provoaca aprinderea amestecului aer
- gaz, neinsotita de explozie.
Influenta substantelor asupra organismului
Gazul de sonda
Avand in vedere compozitia gazului de sonda, cele mai importante simptome sunt asfixierea
fara semnale prevestitoare.
Produsele lichide
Produsele lichide, respectiv gazolina nestabilizata contine produse ca: n-Octan, n-Heptan, nHexan, n-Pentan, i-Pentan, n-Butan.
Produsul poate fi considerat o benzina usoara, putand avea urmatoarele influente asupra
organismului:
- Prin inhalare: poate provoca iritarea sistemului respirator, ameteala, stare de
inconstienta, artimii cardiace si chiar edeme pulmonare;
- Prin contact cu pielea si cu ochii: provoaca iritarea pielii si aparitia de dermatite;
stropirea cu produs lichid conduce la iritarea ochilor;
- Prin inghitire: provoaca iritare la nivelul sistemului digestiv, dureri stomacale, greata,
stare de voma. Aspirarea accidentala a produsului in plamani conduce la bronsite.
Compozitia lichidului la iesirea din skid este prezentata in tabelul 5.
7.2. MASURI DE SIGURANTA PREVAZUTE IN PROIECT
Principala masura care sta la baza prevenirii accidentelor de munca de orice tip o reprezinta
respectarea cu strictete a normelor procesului tehnologic si folosirea la parametrii nominali a
instalatiilor de masura si control precum si atenta intretinere a instalatiei.
Masuri prevazute pe linie tehnologica automatizare si proiectare utilaje
a) Semnalizarea la PCS a depasirii presiunii si temperaturii normale de lucru;
b) Semnalizarea la PCS a depasirii valorii prescrise de nivel normal in utilajele tehnologice;
c) Utilajele sunt din materiale corespunzatoare mediului vehiculat si conditiilor de lucru;
d) Pentru flansele utilajelor s-a adoptat suprafata de etansare corespunzatoare mediului din
vas;
e) Utilajele sunt prevazute cu supape de siguranta conform normelor in vigoare, care vor fi
setate sa deschida in caz de depasire a valorii de presiune prescrise;
f) Toate esaparile supapelor de siguranta, aerisirile sunt dirijate in conducta de aerisiri a
schelei.
g) Dimensionarea utilajelor s-a facut avandu-se in vedere normativele corespunzatoare
mediului si conditiilor de lucru din vase;
h) S-a prevazut izolarea utilajelor prin prevederea de robinete montate pe alimentare, iesire
produs;
i) S-a prevazut sistem de detectie a scaparilor de gaze;
Masuri asigurate la realizarea montajului tehnologic
Principalele masuri luate din acest punct de vedere sunt:
a) Prin proiect s-au realiazat o constructie compacta pentru montarea utilajelor componente
ale skidului.
b) Montarea utilajelor s-a prevazut la distante corespunzatoare pentru a asigura deservirea
acestora si circulatia personalului de operare;
c) S-au prevazut spatii de acces pentru intretinere
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
63 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
d) Au fost prevazute platforme de acces pentru interventie si exploatare, fapt pentru care
acestea vor fi tot timpul libere pentru acces;
e) Prin proiect s-a asigurat o amplasare rationala;
f) Pentru scurgerea corespunzatoare si evitarea acumularilor fluidelor pe portiuni de conducte
s-au asigurat pante corespunzatoare;
g) Armaturile montate pe conducte sunt corespunzatoare mediului de lucru;
h) Conductele sunt din materiale corespunzatoare;
i) Prin proiect s-a prevazut ca inainte de darea in exploatare, toate conductele sa fie supuse
unor teste de presiune care sa asigure functionalitatea corespunzatoare.
Alte masuri de prevenire
Contra electricitatii statice s-a prevazut legarea la pamant a tuturor vaselor tehnologice prin
care se vehiculeaza fluide inflamabile.
7.2.1. INSTRUCTIUNI GENERALE
Prescriptii generale
In sala de comanda se va tine la dispozitie personalului de exploatare urmatoarele:
a) Regulamentul de functionare;
b) Instructiuni privind sanatatea si securitatea in munca;
c) Instructiunile PSI;
d) Regulamentul de ordine interioara a unitatii.
e) Manualul de operare al skidului LTS
Tot acest material trebuie cunoscut de fiecare lucrator al instalatiei.
Indicatoare de securitate
Atat in incinta skidului cat si in zona adiacenta vor fi afisate plancarde avertizoare.
ATENTIE GAZE PERICOL DE EXPLOZIE PERICOL DE FOC FUMATUL OPRIT
Zonele unde se produc scapari de gaze temporare si care prezinta pericol, vor fi imprejmuite si
marcate cu plancarde avertizoare.
Scari, platforme
Scarile, podestele, balustradele si trecerile trebuiesc mentinute in perfecta stare de utilizare si
curatenie.
Orice defectiune va fi imediat remediata.
Prevederile privind echipamentul de protectie
Stabilirea mijloacelor individuale de protectie (sortimente si tipuri) care compun echipamentul
individual de protectie ce trebuie acordat unei persoane, se face pe baza analizei si cumularii
factorilor de risc la care aceasta este expusa pe durata indeplinirii sarcinii de munca si este in
sarcina utilizatorului final al skidului LTS.
7.3. MASURI SPECIFICE PRIVIND SECURITATEA SI SANATATEA IN MUNCA
Utilajele
Utilajele vor lucra numai la parametri tehnici pentru care au fost proiectate.
Se va respecta strict tehnologia prevazuta pentru utilajele respective si sunt interzise orice
modificari ale proceselor tehnologice.
Sunt interzise improvizatiile de orice natura in functionarea utilajelor si uneltelor care au
defectiuni sau care nu sunt prevazute cu toate dispozitivele de protectie necesare asigurarii
securitatii muncii.
Pe categorii de utilaje se impune respectarea si a urmatoarelor masuri principale.
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
64 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
65 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
Slabirea sau strangerea prezoanelor la vase sau liniile sub presiune, fara a dispune de chei
dinamometrice cu sarcina de strangere limitata.
Reguli generale:
Echipamentele si circuitele se vor controla la intervale de maximum doua ore.
Deschiderea utilajelor se va face numai dupa efectuarea operatiunilor de purjare,
obligatorii la fiecare oprire si pornire si dupa ce s-au montat blindele de separare a
circuitelor de restul sistemelor sub presiune, a legaturilor spre facla etc., astfel incat sa
fie exclusa orice posibilitate ca printr-o manevra gresita sa se dirijeze spre aparat fluxuri
de produse, gaze, abur etc.
Deschiderea gurilor de vizitare se va face numai de sus in jos.
Intrarea in vase pentru executarea lucrarilor de curatare si inspectie este admisa numai
in baza Permisului de intrare in vase si aparate tehnologice semnat de persoanele ce
detin functiile indicate pe permis.
Permisul de intrare in aparatele tehnologice pentru curatare si control va putea fi eliberat
numai dupa executarea tuturor lucrarilor obligatorii indicate pe permis.
Lucrarile de curatare si inspectie in vase se vor executa numai cu scule care nu produc
scantei.
Se interzice intrarea la lucru in vase a caror temperatura in interior depaseste 40C.
Permisul de lucru cu foc in aparate va fi eliberat de seful instalatiei, care va indica pe
permis, in afara masurilor obligatorii si eventual masuri speciale care trebuie luate
pentru desfasurarea lucrului fara pericol de accidente.
Permisul de lucru cu foc este valabil pana la sfarsitul zilei pentru care a fost eliberat.
Probele de gaze pentru lucru cu foc in vase se vor recolta dupa terminarea lucrarilor de
curatare si dupa ce au fost montate blindele pentru separarea aparatului de restul
circuitelor.
Probele de gaze se vor repeta in fiecare zi inainte de inceperea lucrului, in toate cazurile
in care se produc schimbari si ori de cate ori exista dubiu asupra continutului de gaze in
atmosfera in care urmeaza sa se execute lucrarea.
In vasele in care se lucreaza pentru curatare ca si in cele in care se lucreaza cu foc se
va asigura o ventilatie corespunzatoare, care sa asigure improspatarea atmosferei din
recipient, astfel ca sa nu puna in pericol sanatatea muncitorilor.
Cand urmeaza sa se execute cu foc in interiorul sau exteriorul unui vas toate
suprafetele care vor fi incalzite trebuie curatate la metal pentru a evita volatilizarea
produselor ce eventual se gasesc sub cruste.
Depunerile sau crustele care se pot aprinde spontan cand sunt desprinse trebuie mentinute
umede, pina cand sunt indepartate din aparat (sulfuri piroforice).
Dupa terminarea lucrului in vase, muncitorii vor verifica daca nu au lasat in vas diferite
scule, lampi, scanduri sau alte obiecte.
Se interzice depozitarea materialelor de orice fel pe podetele echipamentelor.
Se interzice urcarea persoanelor fara interes de serviciu pe scarile si podetele vaselor.
Se interzice lucrul si accesul in instalatie fara echipamente de protectie.
Frecventa inspectiilor periodice a vaselor se va stabilii tinand seama de pierderea in
grosime a peretilor aparatelor in timp de un an, datorita eroziunilor si coroziunilor.
Probele de presiune ale vaselor se vor executa in conformitate cu instructiunile ISCIR
pentru recipienti sub presiune in prezenta inspectorului de instalatie.
Se interzice folosirea vaselor, etc. la care s-a depasit termenul de inspectie si proba
hidraulica mentionat in certificatul de functionare.
La utilaje presiunile de proba se vor executa cu apa.
Conducte si armaturi
Se interzice demontarea oricarei conducte inainte de golirea ei, degajarea presiunii si racirea
ei, pana la conditii nepericuloase. Inceperea operatiuniilor se face numai dupa indeplinirea
conditiilor prevazute de legislatia in vigoare si regulamentele interne ale utilizatorului final.
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
66 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
67 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
68 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
Se vor lua masuri de legare cu centura de siguranta a muncitorilor care lucreaza in utilaje,
astfel incat in cazul in care este necesara tragerea lui afara, acesta sa nu se aseze transversal
pe gura de vizitare.
Persoana din interior care lucreaza va fi permanent supravegheata de catre doi muncitori ce
vor sta afara la gura de vizitare si care au urmatoarele obligatii:
Sa dea ajutor muncitorului din aparat in caz de nevoie;
Sa controleze si sa asigure permanent aductiunea de aer proaspat;
Sa supravegheze puritatea aerului trimis;
La recipientii sub presiune, reparatiile se vor face de catre angajati calificati pentru
efectuarea acestor lucrari si pe baza de permis de lucru aprobat zilnic de seful instalatiei.
Pentru lucrari care se executa la inaltimi de peste 2 m sau la lucrari pentru care exista pericol
de alunecare si cadere, muncitorii vor fi prevazuti cu centuri de siguranta ale caror franghii vor fi
bine legate de un punct fix, apropiat si care sa prezinte rezistenta necesara pentru asigurarea
securitatii in orice conditii de cadere.
Imediat ce s-a executat o reparatie la un loc de munca, se vor monta la loc toate dispozitivele
de protectie de la aparatul sau locul respectiv dupa ce au fost revizuite si reparate.
Cu privire la repornirea utilajelor dupa reparatii, se precizeaza:
Toate lucrarile de reparatii, constructii montaj, vor fi receptionate de utilizatorul final,
verificandu-se daca acestea sunt corespunzatoare atat din punct de vedere tehnictehnologic cit si din punct de vedere al protectiei muncii si daca sunt in conformitate cu
documentatia avizata de forurile competente.
Punerea in functiune a utilajelor, aparatelor instalatiei este admisa tinandu-se seama si de
urmatoarele:
Sa existe toate autorizatiile cerute de legistatia in vigoare;
Sa fie asigurate toate masurile de protectie si igiena a muncii conform actelor normative in
vigoare;
Sa existe montate corect si in buna stare de functionare toate dispozitivele si aparatele de
protectie;
Intreg personalul sa fie instruit, atat din punct de vedere al tehnologiei, cat si din punct de
vedere al protectiei muncii;
Utilajele, aparatele, etc., sa fi fost receptionate si supuse probelor mecanice si tehnologice,
conform prevederilor legale in vigoare si a regulamentului intern al utilizatorului final.
Lucrari paralele
Skidul LTS este un echipament compact si nu se recomanda executarea de lucrari paralele.
Predarea lucrarilor
Toate lucrarile de reparatii, constructii montaj, etc., vor fi receptionate de utilizatorul final,
verificandu-se daca acestea sunt corespunzatoare atat din punct de vedere tehnologic cat si
din punct de vedere al protectiei muncii.
Pornirea skidului LTS se va face numai daca:
a) Exista toate autorizatiile prealabile si autorizatiile de functionare cerute de legistatia in
vigoare;
b) Sunt asigurate toate conditiile de protectia muncii;
c) Exista si sunt montate corect si in buna stare de functionare, toate dispozitivele, aparatele si
instalatiile de protectie.
7.3.3. MASURI GENERALE PENTRU CAZURI DE AVARIE
In cadrul instalatiei se pot semnala cazuri de avarie in diferite situatii ca:
Avarii tehnologice, cauzate de abateri periculoase de la parametrii de functionare;
Avarii mecanice, fisuri sau sparturi la utilaje, defectarea etansarilor;
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
69 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
70 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
71 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
72 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
73 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
74 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
Exercitiile sunt destinate intregului personal de exploatare al personalului utilizatorului final, cat
si formatiei civile de pompieri (avand in vedere numarul limitat al personalului de operare).
Exercitiile trebuie facute semestrial, utilizand planul de interventie al clientului si echipamentele
prevazute in conformitate cu prevederile legale in vigoare si cu regulamentul intern al clientului
final, exersand tehnicile speciale cerute de lupta cu focurile de gaz de sonda sau cu
dispersarea norilor de gaz.
C. Intocmirea unui plan de interventie pentru situatii de incendiu
Pentru situatii de incendiu este esentiala intocmirea de catre utilizatorul final a unui plan de
interventie in caz de incendiu, aprobat de personalul desemnat al utilizatorului final.
La intocmirea planului se va tine cont de urmatorii factori:
a) Personalul de exploatare al utilizatorului final trebuie sa cunoasca foarte bine tehnicile de
combatere a scaparilor de gaze;
b) Daca apare o scapare sau un foc de gaze, este de datoria personalului de exploatare al
utilizatorului final sa foloseasca echipamentul prevazut sau sa-si indeplineasca sarcinile
distribuite prin planul de interventie;
c) Intregul personal de exploatare al utilizatorului final trebuie sa stie sa identifice echipamentul
de control al focului destinat lucrului cu GPL, amplasarea acestuia cat si modalitatile de
folosire;
d) Personalul de exploatare al utilizatorului final trebuie sa cunoasca pozitionarea si metodele de
operare a tuturor robinetelor de siguranta din incinta instalatiei;
e) Personalul de operare trebuie sa fie instruit si sa cunoasca semnele conventionale de
recunoastere a echipamentelor de control, de prim ajutor si de siguranta, trebuie sa stie
amplasarea iesirilor din incinta depozitului si a hidrantilor de incendiu si trebuie sa fie
familiarizat cu sunetul alarmei de urgenta (incendiu).
Planul de interventie la foc trebuie afisat in locuri vizibile si usor accesibile.
Planul trebuie sa contina urmatoarele instructiuni, conform specificului activitatii din incinta
schelei si sa fie intormit de catre utilizatorului final in conformitate cu prevederile legale in
vigoare si regulamentul sau intern:
1. Alarmarea formatiei de pompieri din schela.
2. Modalitati de stopare a surselor care alimenteaza scaparile de gaz sau focurile.
3. Dotarea cu mijloace de prevenire si stingere a incendiilor si de prim ajutor.
4. Modalitati de dispersare a vaporilor de gaze.
5. Indepartarea tuturor surselor de aprindere in caz de scurgere de produs.
6. Evacuarea vehiculelor si/sau interzicerea accesului acestora in zona.
7. Evacuarea personalului.
8. Stabilirea unui centru de coordonare a interventiei, dotat cu legaturi telefonice fixe sau mobile.
9. Controlul traficului.
10. Ierarhizarea si sarcinile personalului de interventie.
11. Asigurarea zonei afectate.
12. Afisarea numerelor de telefon pentru Brigada Locala de Pompieri militari, Inspectoratul de
Aparare Civila, salvare, Politie, etc.
7.6. PROTECTIA MEDIULUI INCONJURATOR
In timpul functionarii skidului, se vor respecta urmatoarele reglementari referitoare la protectia
mediului.
Ordonanta de urgenta nr.195 din 22 decembrie 2005 privind protectia mediului;
Legea nr. 265/2006 pentru aprobarea Ordonantei de urgenta a guvernului nr. 195/2005
privind protectia mediului;
OUG 243/2000 privind protectia atmosferei;
Legea 655/2001 pentru aprobarea OUG 243/2000 privind protectia atmosferei;
S.C. ALCONEX S.R.L
BUCURESTI, ROMANIA
PAGINA
75 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.
This document is the property of ALCONEX and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization.
We will claim legal protection against any abuse.
PAGINA
76 of/din 76
MANUAL DE OPERARE
LOW TEMPERATURE SEPARATION SKID
Model: ACX-LTSU-1000-490-PN63
REV.