SPECIFICATII INFRASTRUCTURA –

LAN/WAN
Enter a number.
Enter a date.

05/05/2021 2
CONTENTS INDEX

Table Index .............................................................................................................................................................................. 4

Figure Index ............................................................................................................................................................................ 5

1. INTRODUCTION/INTRODUCERE................................................................................................................................ 6
1.1 AIM/SCOPUL PROIECTULUI ...............................................................................................................................6
1.2 AIRPORT OVERVIEW/PREZENTAREA GENERALA A AEROPORTULUI .................................................6
1.3 ASSUMPTIONS/PRESUPUNERI ......................................................................................................................... 7
1.4 GENERAL REFERENCE DOCUMENTS & STANDARDS/DOCUMENTE GENARALE DE
REFERINTA SI STANDARDE APLICABILE ..................................................................................................................... 10

2. LOCAL AREA NETWORK AND WIDE AREA NETWORK (LAN/WAN)/RETEAUA LOCALA SI RETEAUA
GLOBALA (LAN/WAN) ............................................................................................................................................................ 17
2.1 SCOPE OF WORKS/SCOPUL LUCRARILOR................................................................................................. 18
2.2 SYSTEM REQUIREMENTS/CERINTE DE SISTEM ........................................................................................ 21

05/05/2021 3
TABLE INDEX

Tabel 1: Referințe generale, standarde și reglementări ICT ........................................................................ 12


Tabel 2: Referințe, standarde și regulamente LAN / WAN .........................................................................14
Table 1: General ICT References, Standards and Regulations .................................................................... 12
Table 2: LAN/WAN References, Standards and Regulations .....................................................................14
Table 3: LAN_WAN System Procurement ........................................................................................................ 25

05/05/2021 4
FIGURE INDEX

Figura 1: Common LAN/WAN System Architecture/ Arhitectura sistemului LAN / WAN ................ 21
Figura 2: FO Ring Architecture/Arhitectura inelului ..................................................................................... 23
Figura 3: LAN/WAN Integration/Integrarea LAN WAN .............................................................................. 46

05/05/2021 5
1. INTRODUCTION/INTRODUCERE

1.1 AIM/SCOPUL PROIECTULUI

This document is intended to contribute to the


Acest document este destinat să contribuie la
Network technical specifications for Brasov
specificațiile tehnice ale rețelei pentru
International Airport specifically addressing all
Aeroportul Internațional Brașov care se
Services that shall be provide as part of the
adresează în mod specific tuturor Serviciilor
contract award and that are in the scope of all
care vor fi furnizate ca parte a atribuirii
the suppliers involved.
contractului și care se află în sfera tuturor
furnizorilor implicați.
The services include information about
Serviciile includ informații despre implicarea
stakeholder engagement, supplier
părților interesate, responsabilitățile
responsibilities, project documentation,
furnizorilor, documentația proiectului,
quality, project management, etc.
calitatea, managementul proiectului etc.
All these services detailed within the following
Toate aceste servicii detaliate în următoarele
sections shall be included and quoted as part
secțiuni vor fi incluse și citate ca parte a
of the technical and commercial offers for
ofertelor tehnice și comerciale pentru FIECARE
EACH of the systems detailed within the
a sistemelor detaliate în specificațiile
system specifications.
sistemului.

1.2 AIRPORT OVERVIEW/PREZENTAREA GENERALA A AEROPORTULUI

The Brasov International Airport, Ghimbav,


Aeroportul Internațional Brașov, Ghimbav,
Romania with IATA designator BRV, is planned
România, cu desemnatorul IATA BRV, este
to be finished by the June 2021 with an initial
planificat să fie finalizat până în iunie 2021, cu
low capacity that it is expected to reach one (1)
o capacitate inițială redusă, pe care se
million passengers by 2029.

05/05/2021 6
așteaptă să ajungă la un (1) milion de pasageri Brasov International Airport (BIA) is a new
până în 2029. International Airport with Runway expected
Aeroportul Internațional Brașov (BIA) este un orientation 04/22. Essential to the operation
nou Aeroport Internațional cu orientarea of Air Traffic Services (ATS) within the current
preconizată a pistei 04/22. Air Traffic and any future airspace arrangements is the
Management a cladirii de contingenta este Air Traffic Management carried out within the
esențială pentru funcționarea Air Traffic Control Facility. This document will analyse
Services (ATS) în cadrul amenajărilor actuale și the Technical and Operational Solution to
viitoare ale spațiului aerian. Acest document provide the Technical Specifications for the
va analiza soluția tehnică și operațională tender process.
pentru a furniza specificațiile tehnice pentru
procesul de licitație.
Soluția aleasă este Remote Digital Control The chosen solution is a Remote Digital
Tower deservit de camere Control Closed Control Tower served by dedicated Control
Circuit Television (CCTV) și situat într-o cladire Closed Circuit Television (CCTV) cameras and
la distanță în afara aeroportului din Brașov. situated in a remote facility outside Brasov
Remote-Control Tower va efectua serviciile Airport. The Remote-Control Tower will
Tower și Approach. perform Tower and Approach Services.

1.3 ASSUMPTIONS/PRESUPUNERI

The following assumptions were validated for


Următoarele ipoteze au fost validate de Client
the Concept of Operation by the Client and
pentru Conceptul operational și vor fi
will be considered as the baseline for this
considerate ca bază pentru acest document:
document:
 One flight will be assured by Brasov
• Un zbor va fi asigurat de Aeroportul Brașov
Airport for all the equipment using the
pentru toate echipamentele utilizand

05/05/2021 7
aeronava AACR. Dacă oricare dintre RCAA aircraft. If any of the tested
echipamentele testate nu funcționează corect equipment is not function properly,
și sunt necesare zboruri de calibrare and further calibration flights are
suplimentare, cheltuiala va fi suportată de needed, the expense will be supported
Furnizor; by the Supplier;
• Înregistrarea VREC va rămâne stocată  The VREC recording will retain storage
minimum 31 de zile; for minimum 31 days;
• VREC Replay Station va fi amplasată la  The VREC Replay Station will be
cladirea RVT; located at the RVT facility;
• Approach Procedural (APP) Control va fi  The Approach Procedural (APP)
livrată de ROMATSA de la RVT; Control function will be delivered by
ROMATSA from the RVT;
• APP CWP va fi amplasat în aceeași cameră  The APP CWP will be located in the
cu TWR EX / PL; same room as TWR EX/PL;
• RVT va avea patru (4) CWP: TWR EX / PL,  The RVT will have four (4) CWP: TWR
APP, Spare și Supervisor; EX/PL, APP, Spare and Supervisor;
• Cladirea de contingenta va fi implementată  The contingency facility will be
la Brașov și va avea aceeași distribuție CWP; deployed at Brasov and will have the
same CWP distribution;
• Toate antenele VHF și EVHF vor fi instalate la  All VHF and EVHF antennas will be
un TWR Pylon / Comm situat în aceeași poziție installed at a Pylon/ Comm TWR
cu TWR tradițional din Brașov; located at the same position of the
traditional TWR in Brasov;
• Serviciul No Surveillance va fi furnizat BIA pe  No Surveillance service will be
termen scurt sau mediu. Va fi luată în provided to BIA in the short to
considerare capacitatea de rezervă pentru medium term. Spare capacity for
extinderea / echipamentele viitoare; future expansion/equipment will be
considered;

05/05/2021 8
• Radiourile ATIS VHF vor avea un TX și un RX;  ATIS VHF Radios will have one TX and
one RX;
• Radio-urile RFFS VHF vor avea un singur RX;  RFFS VHF Radios will have only one
RX;
• ROMATSA are o acoperire insuficientă de  ROMATSA has insufficient surveillance
supraveghere pentru a furniza Approach coverage to provide Radar Approach
Control Surveillance (APS) pentru BIA, astfel va Control Surveillance (APS) services for
fi furnizat un serviciu procedural; BIA thus a Procedural service will be
provided;
• BIA Safety Management System(SMS) se va  BIA Safety Management System (SMS)
alinia cu SMS-ul ROMATSA; will align with the ROMATSA SMS;
• Nu există nicio cerință pentru un Non-  There is no requirement for a Non-
Directional Beacon (NDB); Directional Beacon (NDB);
• Instrument Landing System (ILS) va sprijini  The Instrument Landing System (ILS)
operațiunile din categoria III, inclusiv cerințele will support Category III operations
de infrastructură asociate (de exemplu, including associated infrastructure
Aeronautical Ground Lighting, Instrumented requirements, (e.g. Aeronautical
Runway Visual Range (IRVR), etc.). Ground Lighting, Instrumented
Runway Visual Range (IRVR), etc...).
• Validarea aeroportului pentru cerințele  The Airport validation for ILS Cat III
operaționale ILS Cat III este în afara scopului operational requirements is out of
acestui studiu; scope of this study;
• Mijloacele principale de Instrument  Primary means of Instrument
Approach vor fi abordarea ILS către un singur Approach will be the ILS approach to
capăt de pistă (RWY 22); a single runway end (RWY 22);
• ILS va fi susținut cu proceduri PBN și VHF  The ILS will be supported with PBN
Omni Directional Range / Distance Measuring and VHF Omni Directional
Equipment (VOR / DME), pentru ambele Range/Distance Measuring Equipment
capete de pistă, ca situație de urgență;

05/05/2021 9
(VOR/DME) procedures, for both
runway ends, as contingency;
• Un minim de trei legături de date duale și  A minimum of three dual and diverse
diverse vor fi disponibile între locatia Brașov și data links will be available between
locatia RVT; Brasov facility and the RVT facility;
• Sistemul AWOS va lua în considerare  The AWOS System will consider the
capacitatea de integrare viitoare cu un sistem capability for future integration with a
MET / AIS prin AFTN / AMHS; MET/AIS System via AFTN/AMHS;
• Sistemul MET / AIS și furnizarea nodului  The MET/AIS System and AFTN/AMHS
AFTN / AMHS nu sunt luate în considerare în node provision is not considered
domeniul de aplicare actual pentru BIA. under the current scope for BIA.
• În plus, se presupune că infrastructura de  Furthermore, it is assumed that voice
voce și date (de exemplu, circuite de telefonie and data infrastructure (e.g.
etc.) va fi asigurată de Aeroportul Brașov. Telephones circuits, etc.) will be
provided by the Brasov Airport.

1.4 GENERAL REFERENCE DOCUMENTS & STANDARDS/DOCUMENTE GENARALE DE


REFERINTA SI STANDARDE APLICABILE

The following external legal, regulatory


Următoarele standarde juridice, de
standards and/or policies have been followed
reglementare și / sau politici externe au fost
during the Technical Concept design:
respectate în timpul proiectării Conceptului
Tehnic:
 Legal/Regulatory standards
 Legal/Regulatory standards
specifically related with airports:
specifically related with airports:

05/05/2021 10
 ICAO Annex 14 Aerodrome  ICAO Annex 14 Aerodrome
Design and Operations; Design and Operations;
 ICAO Doc 4444 Procedures for Air  ICAO Doc 4444 Procedures for Air
Navigation Services - Air Traffic Navigation Services - Air Traffic
Management; Management;
 EASA EU 2017/373 Air Traffic  EASA EU 2017/373 Air Traffic
Management / Air Navigation Management / Air Navigation
Services; Services;
 EASA EU 1034/2011 Safety  EASA EU 1034/2011 Safety
Oversight in Air Traffic Oversight in Air Traffic
Management and Air Navigation Management and Air Navigation
Services; Services;
 EASA EU 1035/2011 Common  EASA EU 1035/2011 Common
Requirements for the Provision of Requirements for the Provision of
Air Navigation Services; Air Navigation Services;
 EASA Annex I to ED Decision  EASA Annex I to ED Decision
2019/004/R Guidance Material on 2019/004/R Guidance Material on
Remote Aerodrome Air Traffic Remote Aerodrome Air Traffic
Services; Services;
 Romanian Civil Aviation Authority;  Romanian Civil Aviation Authority;
 Romanian National Standards;  Romanian National Standards;
 European Standards;  European Standards;
 International Standards.  International Standards.

 Legal/Regulatory standards generally  Legal/Regulatory standards generally


related with design and deployment: related with design and deployment:

Code/standard Title Code/standard Title


identification identification
ISO 9001 Quality ISO 9001 Quality
Management Management

05/05/2021 11
RS IEC 60364 Electrical RS IEC 60364 Electrical
Installations of Installations of
buildings buildings
RS IEC 61000 Electromagnetic RS IEC 61000 Electromagnetic
compatibility compatibility
(EMC) (EMC)
INCITS SQL Database INCITS SQL Database
Standards Standards
ISO 9126 Software Quality ISO 9126 Software Quality
BICSI Building Industry BICSI Building Industry
Consulting Helps. Consulting Helps.
International International
UL Underwriters UL Underwriters
Laboratory Laboratory
ISO/IEC 27001 Information ISO/IEC 27001 Information
Security Security
PAS99 Integration PAS99 Integration
Management Management
ISO/IEC 20000 IT Service ISO/IEC 20000 IT Service
Management Management
Tabel 1: Referințe generale, standarde și Table 3: General ICT References, Standards
reglementări ICT and Regulations/

Regulamentele menționate mai sus sunt Regulations above mentioned are


revizuite și actualizate continuu, astfel încât continuously reviewed and updated so this list
această listă ar putea necesita actualizarea în might require to be updated in the future to
viitor pentru a include cele mai recente include the latest requirements.
cerințe. All the measures provided in this design have
Toate măsurile prevăzute în acest proiect au been given using the International System of
fost date folosind International System of units units (IS).
(IS).

Code/standar Title Code/standar Title


d d
identification identification

05/05/2021 12
ANSI/TIA/EIA- Measurement of ANSI/TIA/EIA- Measurement of
526-7 and 14A Optical Power Loss 526-7 and 14A Optical Power Loss
of Installed Single- of Installed Single-
Mode / Multimode Mode / Multimode
Fiber Cable Plant Fiber Cable Plant
ANSI/TIA/EIA- Commercial ANSI/TIA/EIA- Commercial
568-B Building 568-B Building
Telecommunication Telecommunication
s Cabling Standard s Cabling Standard
ANSI/TIA/EIA- Commercial ANSI/TIA/EIA- Commercial
569-A Building Standard 569-A Building Standard
for for
Telecommunication Telecommunication
s Pathways and s Pathways and
Spaces Spaces
ANSI/TIA/EIA- Commercial ANSI/TIA/EIA- Commercial
569-B Building Standard 569-B Building Standard
for for
Telecommunication Telecommunication
s Pathways and s Pathways and
Spaces Spaces
ANSI/TIA/EIA- Administration ANSI/TIA/EIA- Administration
606-A Standard for the 606-A Standard for the
Telecommunication Telecommunication
s Infrastructure of s Infrastructure of
Commercial Commercial
Buildings Buildings
ANSI/TIA/EIA- Commercial ANSI/TIA/EIA- Commercial
607-A Building Grounding 607-A Building Grounding
and Bonding and Bonding
Requirements for Requirements for
Telecommunication Telecommunication
s s
ANSI/TIA 942 Telecommunication ANSI/TIA 942 Telecommunication
s Infrastructure for s Infrastructure for
Data Centres Data Centres
BICSI – TDMM Telecommunication BICSI – TDMM Telecommunication
s Distribution s Distribution
Methods Manual Methods Manual
BICSI - Customer-Owned BICSI - Customer-Owned
COOPDM Outside Plant COOPDM Outside Plant
Design Manual Design Manual

05/05/2021 13
BICSI - ITSIM Information BICSI - ITSIM Information
Transport Systems Transport Systems
Installation Manual Installation Manual
BICSI - NDRM Network Design BICSI - NDRM Network Design
Reference Manual Reference Manual
BICSI - WDRM Wireless Design BICSI - WDRM Wireless Design
Reference Manual Reference Manual
IEC 603-7 Current capacity for IEC 603-7 Current capacity for
connectors connectors
IEEE 802.1 LAN/MAN Bridging IEEE 802.1 LAN/MAN Bridging
and Management and Management
IEEE 802.3 CSMA/CD Access IEEE 802.3 CSMA/CD Access
Methods (Ethernet) Methods (Ethernet)
IEEE 802.3ae 10 Gigabit IEEE 802.3ae 10 Gigabit
specification specification
IEEE 802.3z 1000 Base-S IEEE 802.3z 1000 Base-S
specification specification
IEEE 802.3ab 1000 Base-T IEEE 802.3ab 1000 Base-T
specification specification
IEEE Power over IEEE Power over
802.3af/at Ethernet 802.3af/at Ethernet
IEEE 802.3u 100 Base-T IEEE 802.3u 100 Base-T
specification specification
IEEE 802.1Q VLAN IEEE 802.1Q VLAN
IEEE 802.1P Prioritization IEEE 802.1P Prioritization

Tabel 2: Referințe, standarde și regulamente Table 4: LAN/WAN References, Standards and


LAN / WAN Regulations

05/05/2021 14
LIST OF ABBREVIATIONS AND ACRONYMS/LISTA ABREVIERILOR SI ACRONIMELOR

Abbr. Meaning
ACC Air Control Centre
AIS Aeronautical Information Service
APP Approach
ATC Air Traffic Control
ATIS Automatic Terminal Information System
ATS Air Traffic Services
BIA Brasov International Airport
BRV Brasov
CAT Category
CCTV Close Circuit TV
CE Conformité Européenne
COTS Commercial Of The Shelf
CMS Control Monitoring System
CWP Controller Working Position
DME Distance Measuring Equipment
DVOR Doppler VHF Omni Range
EASA European Union Aviation Safety Agency
EMC Electro Magnetically Compatibility
EVHF Emergency Very High Frequency
IATA International Aviation Transport Association
ICAO International Civil Aviation Organization
IEC International Electrotechnical Commission
IEEE Institute of Electrical and Electronics Engineers
ILS Instrumental Landing System
IRVR Instrumented Runway Visual Range
IS International System
ISO International Standards Organisation
LAN Local Area Network
LRU Line Replacement Unit
MCS Master Clock System
MEP Mechanical, Electrical & Plumbing
MET Meteorological
MTBF Mean Time Between Failures
MTTR Mean Time To Repair
NAS Network Attached Storage
NDB Non-Directional Beacon
NTP Net Time Protocol
OR Operational Requirement

05/05/2021 15
PABX Private Automatic Branch Exchange
PSTN Public Switched Telephone Network
PTT Push To Talk
RCAA Romanian Civil Aviation Authority
RFFS Rescue and Fire-Fighting Services
RVT Remote Virtual Tower
RWY Runway
TMCS Technical Monitoring Control Syste,
TWR Tower
UPS Uninterrupted Power Supply
UTC Coordinated Universal Time
UTP Unshielded Twisted Pair
VCCS Voice Communication and Control System
VHF Very High Frequency
VOR VHF Omni Range
VREC Voice Recording
WAN Wide Area Network

05/05/2021 16
2. LOCAL AREA NETWORK AND WIDE AREA NETWORK (LAN/WAN)/RETEAUA LOCALA SI
RETEAUA GLOBALA (LAN/WAN)

The LAN/WAN system will provide a


Sistemul LAN / WAN va oferi o infrastructură
consolidated communications infrastructure
de comunicații consolidată compusă din
comprised of copper and fibre optic cables
cabluri de cupru și fibră optică direcționate în
routed throughout the airport facilities and
toate facilitățile aeroportului și echipamentele
the active network equipment needed. This
de rețea active necesare. Acest sistem ar trebui
system should provide transmission media for
să furnizeze suporturi de transmisie pentru
video, voice and data signals.
semnalele video, vocale și de date.
The objective of the network is to provide
Obiectivul rețelei este de a oferi acces
universal access to voice, video and data
universal la servicii de voce, video și date
services over a common network
printr-o infrastructură comună de rețea. Va fi
infrastructure. It will be a scalable, reliable,
o infrastructură de transport IP cu trei layer-e
highly available three-layer IP network
scalabilă, fiabilă, extrem de disponibilă, pentru
transport infrastructure to meet the
a satisface performanțele și nevoile
performance and operational needs of the
operaționale ale aeroportului. Sistemul LAN /
airport. The LAN/WAN system will provide a
WAN va oferi un layer de bază pentru
base layer for communications between all
comunicațiile dintre toate sistemele și
systems and users connected to this common
utilizatorii conectati la aceasta infrastructura
network infrastructure.
de retea comuna.
The design shall address issues as high
Proiectarea va aborda aspecte precum
availability, scalability, modularity,
disponibilitatea ridicată, scalabilitatea,
manageability, future development potential
modularitatea, capacitatea de gestionare,
and low operating and maintenance costs.
potențialul de dezvoltare viitor și costurile
reduse de operare și întreținere.
The LAN/WAN System will provide services at
Sistemul LAN / WAN va furniza servicii cel
least to:
puțin pentru:
 ATC/CNS
• ATC / CNS

05/05/2021 17
• Supraveghere;  Surveillance;
• Infrastructură;  Infrastructure;
• Personalul și administrația aeroportului;  Airport Staff and Administration;
• Acces la internet;  Internet Access;
• Acces Telefonie;  Telephony Access;
Etc ... Etc…

2.1 SCOPE OF WORKS/SCOPUL LUCRARILOR

A. Sistemul LAN / WAN este cadrul principal The LAN/WAN system is the main
pentru toate celelalte sisteme, întrucât orice framework for all other systems, as all
comunicare între sisteme și utilizatori va fi communication between systems and
controlata de rețeaua aeroportului. users will be controlled by the Airport
network.
B. Sistemul va fi dimensionat în funcție de
The system shall be sized considering
capacitatea finală.
the final capacity.

C. Faptul de a avea un singur sistem capabil The fact of having a single system
să garanteze accesul la rețea, permite capable of guaranteeing network
sistemelor și utilizatorilor să facă schimb de access, allows systems and users to
informații într-un mod simplu și, prin urmare, exchange information in a simple way
un număr mai mare de procese poate fi and therefore a greater number of
automatizat. processes can be automated.
D. Toate considerațiile detaliate mai sus fac All the considerations detailed above
ca sistemele LAN / WAN să fie considerate makes the LAN/WAN Systems to be
esențial. considered as essential.

The LAN/WAN System comprises the


E. Sistemul LAN / WAN cuprinde conexiunea
connection between the with a FO
dintre un inel FO, cablarea structurată în
ring, the structured cabling inside each
interiorul fiecărei clădiri (cladirea Brașov și
building (Brasov facility and RVT
instalația RVT), echipamentul activ / pasiv
facility), the active/passive equipment
pentru desfășurarea inelului FO,
for the FO ring deployment, the
echipamentul necesar pentru a oferi acces
necessary equipment to give external
extern la sistemul LAN / WAN, inclusiv
access to the LAN/WAN system,

05/05/2021 18
conexiunea la cele trei legături între ambele including the connection to the three
site-uri și toate echipamentele de securitate a interlinks between both sites and all
informațiilor necesare pentru protejarea information security equipment
rețelei. needed to protect the network.

In terms of the FO ring, it is within the


F. În ceea ce privește inelul FO, intră în
scope of this tender the ducts, pipes
domeniul de aplicare al prezentei oferte
and fibre cable. The supplier shall
traseele, conductele și cablul de fibră.
define the FO requirements, design
Furnizorul definește cerințele FO, proiectează
the network and provide and
rețeaua și furnizează și configurează
configure the active equipment, patch
echipamentele active, panourile de patch-uri
panels and splicing boxes. The
și cutiile de îmbinare. Furnizorul se va ocupa
supplier shall take care of the
de instalarea și configurarea (inclusiv
installation and configuration
îmbinarea) FO-ului între caminele de vizitare
(including splicing) of the FO between
și echipamentul activ.
the manhole and the active
equipment.

G. Serviciile care urmează să fie furnizate sunt The scope of works for the Services to
incluse ca parte a documentației din caietul be provided are included as part of the
de sarcini. Toate serviciile descrise vor fi tender book documentation. All
incluse ca parte a ofertei tehnice și services described there shall be
comerciale a rețelei care urmează să fie included as part of the Network
furnizate. technical and commercial offer to be
provided.

As an unique supplier shall be


H. Întrucât un furnizor unic va fi castigator
awarded for the complete package, all
pentru pachetul complet, va fi inclus tot
stakeholder engagement between
angajamentul părților interesate între
systems for integration purposed shall
sistemele de integrare menite și, în special,
be included and in particular for the
pentru coordonarea fiecărui sistem pentru
coordination of each system for the
cerințele și nevoile rețelei. Toate integrările și
Network requirements and needs. All
conexiunile sunt obligatii ale Furnizorului in
integrations and connections are
cadrul prezentei proceduri.
within this tender book scope.

I. Furnizarea de energie electrică pentru The power provision for the Buildings
clădire face obiectul acestui contract, astfel is in the scope of the contract, so the
încât Furnizorul va avea o colaborare Supplier shall engage the proper

05/05/2021 19
adecvată cu furnizorul de energie electrică coordination with the power supplier
pentru a le oferi necesitățile și cerințele. In in order to give them the necessities
scopul prezentei oferte se va realiza and requirements. For the purpose of
conexiunea de alimentare între Centrala this offer, the supply connection
Electrica a Aeroportului și cladirea de between the Airport Power Plant and
contingenta. the contingency building will be made.

J. Furnizarea de energie pentru toate


The power provision for all NAVAIDS
echipamentele NAVAIDS și AWOS este
and AWOS equipment are included
inclusă în această ofertă. Aceasta este
within this tender. This responsibility
responsabilitatea furnizorului, respectiv de a
of this supplier to perform the
realiza conexiunea și distribuția completă a
complete power connection and
curentului electric.
distribution.

K. Furnizarea rețelei în ambele clădiri The network provision within both


(cladirea de contingenta Brașov și instalația buildings (Brasov Contingency Facility
RVT) și inelul FO se încadrează în acest and RVT facility) and the FO ring are
domeniu. Fiecare dintre celelalte sisteme din within this scope. Each of the other
acest caiet de sarcini va include dispozitive de systems within this tender book shall
rețea pentru a implementa o rețea include network devices in order to
independentă pentru fiecare sistem, dar deploy an independent network for
această specificație se referă la: each system, but this specification
relates to the:
• Cablare structurată pentru conexiunile de
 Structured cabling for the
sistem din Brașov și instalația Remote;
system connections in Brasov
and Remote facility;
• Implementarea rețelei comune a clădirii de
 The Common network
contingenta Brașov pentru alte utilizări ca
deployment of Brasov
internet, telefonie, implementare CCTV ... etc.
Contingency Building for other
Include firewall-uri și dispozitive necesare
uses as internet, telephones,
pentru securitatea cibernetică;
CCTV deployment…etc.
Including firewalls and
cybersecurity needed devices;
• Implementarea inelului FO, inclusiv cutii de
 The FO ring deployment,
îmbinare și panou patch-uri FO;
including splicing boxes and
FO patchpannel;

05/05/2021 20
• Echipamentul necesar pentru  The necessary equipment to
interconectarea legăturilor externe la sisteme; interconnect the external
interlinks to the systems;
• Echipamentul necesar pentru  The necessary equipment to
interconectarea liniilor externe (FXO, FXS ... interconnect the external lines
etc) la sisteme. ( FXO, FXS…etc) to the systems.

2.2 SYSTEM REQUIREMENTS/CERINTE DE SISTEM

2.2.1 System Architecture/Arhitectura sistemului

RVT FACILITY Tech Room

Access

Aggregation

Access Distribution

Core

Internet
...

Core
Access Distribution
BRASOV AIRPORT VOIP

Aggregation

Access

Tech Room

BRASOV FACILITY

Figura 1: Common LAN/WAN System Architecture/ Arhitectura sistemului LAN / WAN

05/05/2021 21
A. Arhitectura de mai sus descrie rețeaua A. The architecture above is for the
comună amplasata la Brașov pentru a oferi common network to be deployed
birourilor, telefonie, CCTV, acces la internet at Brasov to give use to offices,
etc. telephony, CCTV, internet access,
B. Interlink-urile vor fi conectate și distribuite etc.
la fiecare rețea de sistem B. The interlinks shall be connected
and distributed to each system
C. Cablarea pentru fiecare implementare a network
rețelei de sistem se încadrează în această C. The cabling for each system
specificație network deployment is within this
specification
D. Pentru proiectarea Optical Fiber Ring, este D. For the design of the Optical Fiber
necesar să se ia în considerare un singur inel, Ring, it is necessary to consider a
ceea ce înseamnă două moduri fizice diferite single ring, what means two
de conectare a fiecărei clădiri la inel (în sensul Physical different ways connecting
acelor de ceasornic și în sens invers acelor de each building to the ring
ceasornic). Fiecare clădire trebuie să aibă (clockwise and anticlockwise).
două camine de vizitare separate pentru Each building shall have two
fiecare intrare FO. separate manholes for each FO
entrance.
E. Figura arată cum trebuie realizat inelul, dar E. The drawing shows how the ring
modul în care vor fi desfășurate canalele need to be performed, but how
depinde de proiectarea constructorului. the ducts will be deployed
depends on the constructor
design.
F. Ambele amplasamente, cladirea Brașov și F. Both sites, Brasov facility and RVT
cladirea RVT vor fi conectate la inelul FO facility shall be connected to the
(pentru redundanță și disponibilitate). FO Ring (for Redundancy and
availability).
G. Acest domeniu de aplicare este până la G. This specification scope is until
îmbinarea FO și panoul de patch-uri FO al the FO splicing and FO
fiecărui site. Echipamentul de rețea pentru patchpannel of each site. The
fiecare sit este să fie inclus în fiecare achiziție network equipment for each site
de sisteme shall be included in each of the
systems procurement

05/05/2021 22
RVR CENTRAL GLIDEPATH/DME
AWOS + RVR
DVOR/DME
LOCALIZER AWOS + RVR

CEILOMETER CEILOMETER

RWY04

RWY22

BRASOV FACILITY
FIBER RING

FIBER RING

BRASOV
CONTINGENCY
FACILITY

RVT FACILITY

2 x DEDICATED FIBERS

DEDICATED
INTERLINKS

Figura 2: FO Ring Architecture/Arhitectura inelului

2.2.1.1 Design Decisions/Decizii de proiectare

A. Soluția furnizorului trebuie sa fie A. The supplier solution is to remain


competitivă pe piață și, ca atare, modelul market competitive and as such
final de arhitectură va fi lăsat la dispoziția the final architecture model shall
contractorului pentru a defini cea mai viabilă be left to Contractor to define the
soluție comercială pentru sistemul oferit. most commercially viable solution
for their offered system.
B. Furnizorul este invitat să ofere orice B. The supplier is invited to offer any
echipament care, în opinia sa, este egal sau equipment which in his opinion is
superior cerințelor acestei specificații, astfel equal to or superior to the
încât echivalența sau superioritatea să poată requirements of this specification,
fi determinate cu ușurință. so that equivalence or superiority
can be readily determined.

05/05/2021 23
2.2.1.2 System Procurement/Achizitii de sistem

A. LAN / WAN este un sistem care va rula de LAN/WAN is a system that shall run
pe propriile servere grupate și echipamentele from its own clustered servers and
de bază plasate în Brașov și în Remote core equipment placed in Brasov and
Technical Rooms. Pentru redundanță și
Remote Technical Rooms. For
disponibilitate, fiecare set de nuclee LAN /
redundancy and availability, each set
WAN trebuie instalat într-o cameră tehnică
separată; of LAN/WAN cores shall be installed in
separate Technical Room;

The LAN/WAN is considered to


B. Se consideră că LAN / WAN conține
următoarele echipamente: contain the following equipment:
Item Id Item Cantitate Item Id Item Amount
LAN_WA Core Nodes 2 LAN_WA Core Nodes 2
N 01 N 01
LAN_WA Rack 8 FO LAN_WA Rack 8 FO
N 02 Ring+4. N 02 Ring+4.
TBD TBD
LAN_WA Access/Aggregati 10 LAN_WA Access/Aggregati 10
N 03 on Switches N 03 on Switches
LAN_WA Distribution TBD LAN_WA Distribution TBD
N 04 Switches N 04 Switches
LAN_WA Backbone CAT 6 TBD (for all LAN_WA Backbone CAT 6 TBD (for all
N 05 Cabling system N 05 Cabling system
deployme deployme
nt at nt at
Brasov and Brasov and
RVT RVT
facility) facility)
LAN_WA RJ Outlets TBD LAN_WA RJ Outlets TBD
N 06 N 06
LAN_WA FO Cabling *under LAN_WA FO Cabling *under
N 07 constructio N 07 constructio
n scope n scope
LAN_WA FO Pipes TBD LAN_WA FO Pipes TBD
N 08 N 08
LAN_WA CAT 6 TBD LAN_WA CAT 6 TBD
N 09 Patchpannels N 09 Patchpannels

05/05/2021 24
LAN_WA FO PatchPannels TBD LAN_WA FO PatchPannels TBD
N 10 N 10
LAN_WA Splicing boxes TBD LAN_WA Splicing boxes TBD
N 11 N 11
LAN_WA SFP FO Modules TBD LAN_WA SFP FO Modules TBD
N 12 N 12
LAN_WA Management 2 LAN_WA Management 2
N 13 Workstation N 13 Workstation

Table 5: LAN_WAN System


Procurement

2.2.1.3 Spares Procurement/Achizitii de rezerva

A. Furnizorul va fi responsabil de furnizarea A. The Supplier shall be in charge of


ansamblului de piese de schimb ca parte a providing the ensemble of spares as part of
echipamentului necesar. the required equipment.
B. Furnizorul trebuie să justifice suma și B. The Supplier shall justify the amount
echipamentele de rezervă suplimentare and the additional spares equipment
incluse în domeniul de aplicare pentru a included in the scope in order to fulfil the
îndeplini cerințele de disponibilitate ale availability requirements of LAN/WAN
sistemului LAN / WAN. system.

2.2.2 Functional Requirements/Cerinte functionale

A. Proiectarea va aborda aspecte precum The design shall address issues as high
disponibilitatea ridicată, scalabilitatea, availability, scalability, modularity,
modularitatea, capacitatea de gestionare, manageability, future development
potențialul de dezvoltare viitor și costurile potential and low operating and
reduse de operare și întreținere. maintenance costs.

The LAN/WAN network must provide


B. Rețeaua LAN / WAN trebuie să ofere
connectivity and communications
servicii de conectivitate și comunicații prin
service through itself or by interfacing
capacitate proprii sau prin retele third party
with third party networks for all
pentru toate clădirile și toate infrastructurile

05/05/2021 25
care ar trebui să aibă nevoie de orice buildings and all infrastructure that
transmisie de date sau voce în cadrul acestui should need any data or voice
proiect particular al Aeroportului Brașov. transmission under this particular
project of Brasov Airport.

As security and performance


C. Deoarece cerințele de securitate și
requirements are different depending
performanță sunt diferite în funcție de
on the final user (or department) the
utilizatorul final (sau departament), LAN /
LAN/WAN would be logically divided
WAN va fi împărțit logic în subrețele.
into subnets.

D. Comunicațiile nu trebuie să fie posibile Communications should not be


între elementele situate în subrețele diferite. possible between elements located in
Doar punctele de interfață predefinite, cu different subnets. Only predefined
firewall și capabilități de rutare, trebuie să interface points, with firewall and
poată fi conectate la mai multe subrețele. routing capabilities, should be allowed
to connect to more than one subnet.
E. Zonele / sistemele care trebuie incluse în The areas/Systems that need to be
rețeaua / domeniul LAN / WAN sunt: included under the LAN/WAN
network/scope are:

 VHF (only CAT6 cabling);


• VHF (numai cablare CAT6);
 EVHF (only CAT6 cabling);
• EVHF (numai cablare CAT6);
 VREC (only CAT6 cabling);
• VREC (numai cablare CAT6);
 VCCS (only CAT6 cabling);
• VCCS (numai cablare CAT6);
 ILS/DME (only CAT6 cabling);
• ILS / DME (numai cablare CAT6);
 DVOR/DME (only CAT6 cabling);
• DVOR / DME (numai cablare CAT6);
 AWOS (only CAT6 cabling);
• AWOS (numai cablare CAT6);
 ATIS (only CAT6 cabling);
• ATIS (numai cablare CAT6);
 MCS (only CAT6 cabling);
• MCS (numai cablare CAT6);
 CMS (only CAT6 cabling);
• CMS (numai cablare CAT6);
 CFR (only CAT6 cabling);
• CFR (numai cablare CAT6);
 Surveillance CCTV (only CAT6
• CCTV de supraveghere (numai cablare
cabling);
CAT6);
 Admin Network;
• Rețea de administrare;

05/05/2021 26
• Rețeaua de vizitatori;  Visitors Network;
• Acces la internet;  Internet Access;
• Rețea telefonică (cablare pentru telefoane
 Telephone Network (cabling for
IP conectate la Airport PABX prin Airport
Network); IP phones connected to Airport
PABX through Airport Network);
 RVT facility in remote location
• Cladirea RVT (numai cablarea sistemului și
interfețe de bază pentru interconectarea (only system cabling and core
conexiunilor la infrastructura existentă după interfaces for interlink
concluziile anchetei de amplasament);
connections to existing
infrastructure upon site survey
conclusions);
 Contingency facility in Brasov;
• Cladirea de contingenta în Brașov;
 Ceilometer RWY 22 in Brasov (FO
• Ceilometru RWY 22 la Brașov (inel FO,
splicing și patchpannel FO); ring, splicing and FO
patchpannel);
 Glidepath facility RWY 22 in
• Instalația Glidepath RWY 22 din Brașov (inel
FO, splicing și patchpannel FO); Brasov (FO ring, splicing and FO
patchpannel);
 DVOR facility in Brasov(FO ring,
• DVOR din Brașov (inel FO, splicing și
patchpannel FO); splicing and FO patchpannel);
 AWOS facility RWY 04 in
• AWOS RWY 04 din Brașov (inel FO, splicing
Brasov(FO ring, splicing and FO
și patchpannel FO);
patchpannel);
 Localizer facility RWY 04 in
• Unitatea Localizer RWY 04 din Brașov (inel Brasov(FO ring, splicing and FO
FO, splicing și patchpannel FO);
patchpannel);
 LAN/WAN connection to RVT-
• Conexiune LAN / WAN la legăturile RVT- Brasov links;
Brașov;

05/05/2021 27
• Conexiune între rețeaua LAN / WAN și  Connection between LAN/WAN
aeroport; and Airport network;
 Additionally, the Brasov facility
• În plus, rețeaua din Brașov va partaja toate
informațiile cu rețeaua de facilități RVT prin Network shall share all
intermediul celor 3 interlinkuri (interlinkurile information with RVT facility
sunt în afara domeniului de aplicare).
network through the 3 interlinks
(the interlinks are out of scope).
F. Calitatea serviciului, gestionarea Quality of service, congestion
congestionării și controlul multicast vor fi management and multicast control
puse în aplicare pentru a prioritiza traficul de shall be implemented to prioritize
date din rețea și pentru a gestiona traficul de network data traffic and to manage
date vocale și video în timp real. real-time voice and video data traffic.

Network security shall be an inherent


G. Securitatea rețelei trebuie să fie o parte
part of the design. Firewall and IPS
inerentă a proiectului. Funcționalitatea
functionality shall be implemented at
firewall și IPS vor fi implementate la
the perimeter of the network (for
perimetrul rețelei (pentru acces extern,
external access, Brasov Airport
conexiune la rețeaua aeroportului Brașov și
network connection and Interlinks
legături între site-uri).
between sites).

H. Rețeaua trebuie să poată transporta atât The network shall be able to transport
rețelele private virtuale (VPN) ale stratului 3, both layer 3 and layer 2 Multi-Protocol
cât și stratul 2 Multi-Protocol Label Switching Label Switching (MPLS) Virtual Private
(MPLS) Virtual Private Networks (VPNs) și Networks (VPNs) and encrypt traffic
criptarea traficului cu protocolul IPSec și with IPSec protocol and AES256, DF15,
capabilitățile AES256, DF15, SHA512 . SHA512 capabilities.

The network background traffic


I. Traficul de fundal al rețelei (trafic de servicii, (service traffic, routing updates and
actualizări de rutare și trafic de gestionare) management traffic) shall never
nu trebuie să depășească niciodată 10% din exceed 10% of the total bandwidth of
lățimea de bandă totală a oricărei legături. any link.

The design shall address issues as high


J. Proiectarea va aborda aspecte precum
availability, scalability, modularity,
disponibilitatea ridicată, scalabilitatea,
manageability, future development
modularitatea, capacitatea de gestionare,
potential and low operating and
potențialul de dezvoltare viitor și costurile

05/05/2021 28
reduse de operare și întreținere. Deoarece maintenance costs. As the operational
orele de funcționare ale unui aeroport sunt hours of an airport are 24x7x365,
24x7x365, robustețea, stabilitatea, robustness, stability, scalability and
scalabilitatea și ușurința de gestionare și ease of management and
întreținere sunt considerente cheie de maintenance are key design
proiectare. considerations.

All switches shall have a minimum slot


K. Toate switch-urile trebuie să aibă un slot
and interface port spare capacity of
minim și o capacitate de rezervă de port de
20% for future expansion.
interfață de 20% pentru extinderea viitoare

2.2.3 Security of Information System (SSI)

A. Echipamentul SSI va garanta protecția The SSI Equipment shall guarantee the
sistemelor și datelor împotriva actelor protection of systems and data against
accidentale sau a atacurilor deliberate. accidental acts or deliberate attacks.
Această protecție trebuie să îndeplinească This protection shall meet four
patru obiective: objectives:

 Availability;
• Disponibilitate;
 Integrity;
• Integritate;
• Confidențialitate;  Privacy;
• Identificare.  Identification.

At this stage, the regulatory


B. În această etapă, cadrul de reglementare
framework is not indicated yet. The
nu este încă indicat. Singurul cadru indicat la
only framework indicated at this level
acest nivel este ICAO 8973-capitolul 18 ediția
is the ICAO 8973-chapter 18 10th
a 10-a 2017 sau mai nou, dacă este disponibil.
edition 2017 or newer if available.

C. Se recomandă respectarea standardelor It is recommended to follow the ISO


ISO 27000, 27001, 27002 și 27005, precum și 27000, 27001, 27002 and 27005
a recomandărilor ANSSI. standards, as well as the ANSSI
recommendations.
D. Security Equipment/Firewalls care trebuie The Security Equipment/Firewalls to
furnizate pentru a garanta securitatea be provided to guarantee the security

05/05/2021 29
informațiilor schimbate trebuie să furnizeze of the information exchanged shall
cel puțin următoarele funcționalități: provide at least the following
functionalities:
• Filtrare;
 Filtering;
• IDS / IPS;
 IDS/IPS;
• Proxy;
• Antivirus;  Proxy;
• IPSec si SSL;  Antivirus;
• Server VPN.
 IPSec and SSL;
 VPN Server.

The SSI solutions will be distributed in


E. Soluțiile SSI vor fi distribuite în diferite the different layers of the Information
straturi ale sistemelor informaționale. Soluția Systems. The proposed solution must
propusă trebuie să permită o corelație a allow a correlation of events that occur
evenimentelor care apar la diferite niveluri și at different levels and show the alerts
să afișeze alertele către departamentul IT din to the IT Department in the Technical
sala tehnică, care să fie determinate prin Room to be determined through rule
mecanisme de regulă. mechanisms.

The security equipment shall interact


F. Echipamentul de securitate trebuie să
with:
interacționeze cu:
• Toate echipamentele active și soluția de  All Active equipment and
gestionare a rețelei; network management solution;
 Wireless network (Wi-Fi)
• Echipamente de rețea fără fir (Wi-Fi) (dacă
există); equipment (if any);
 All systems and equipment
• Toate sistemele și echipamentele conectate
connected to the network shall
la rețea vor fi supravegheate; acces la
Internet. be supervised;Internet access.

05/05/2021 30
2.2.4 Design Criteria/criterii de proiectare

A. Toate echipamentele critice ale rețelei A. All network critical equipment shall be
trebuie să aiba back-up cu Uninterruptible back up with an Uninterruptible Power
Power Supply (UPS) care trebuie să întrețină Supply (UPS) that shall maintain the system
sistemul timp cel puțin 2 ore. UPS-ul se during at least 2h. The UPS is under this
furnizeaza in acest contract, deci furnizorul scope, so the supplier shall include the
trebuie să includă cerințele pentru requirements for the power provision.
alimentarea cu energie electrică.

2.2.4.1 Cabling/Cablarea

A. Numai cerințele de bază de cablare sunt A. Only Basic cabling requirements are
incluse în acest capitol pentru scopuri inițiale included in this chapter for initial design
de proiectare. Lista finală și mai precisă a purposes. Final and more accurate
cerințelor trebuie făcută de către furnizor în requirements list shall be done in system
etapele de proiectare a sistemului. design stages by the supplier.

2.2.4.1.1 Horizontal LAN Cabling/cablarea LAN orizontala

A. F / UTP LSZH Categoria 6A este propusa F/UTP LSZH Category 6A rated for
pentru cablarea orizontală, STP atunci când horizontal cabling, STP when critical
sunt implicate sisteme critice. systems are involved.

The horizontal cable length from the


B. Lungimea orizontală a cablului de la
distribution room to the
camera de distribuție la priza / conectorul de
telecommunications outlet/connector
telecomunicații nu trebuie să depășească 90
shall be no more than 90m long.
m lungime.

C. Se acordă 10 m pentru lungimea A 10m allowance is made for the


combinată a cablurilor de patch-uri și a combined length of patch cords and
cablurilor utilizate pentru conectarea cables used to connect equipment.
echipamentelor.
Sufficient space should be provided in
D. Ar trebui să fie prevăzut un spațiu suficient
the telecommunications outlet box or
în cutia de conexiune a telecomunicațiilor sau
equivalent space so that minimum
un spațiu echivalent, astfel încât să nu fie
bend radius requirements are not
depășite cerințele de rază minimă de îndoire.
exceeded.

05/05/2021 31
E. Dacă este necesară o priză în afara cerinței If an outlet is required outside of the
de 90 de metri pentru cablarea din cupru și 90m requirement for copper cabling
cerința este considerată a fi cu densitate prea and the requirement is deemed to be
mică pentru a proiecta o cameră de too low density to design an additional
comunicații suplimentară, trebuie utilizată communications room, fibre optic
cablarea cu fibră optică. cabling must be utilized.
F. Rack-urile și toate celelalte echipamente de
Racks and all other network storage
stocare în rețea trebuie furnizate in acest
equipment is within this scope
contract.
G. Furnizorul va lua în considerare în acest The Supplier shall consider inside this
domeniu cablarea tuturor sistemelor scope of cabling of all systems
menționate mai sus. Furnizorul va efectua mentioned above. The Supplier shall
toate conexiunile necesare între toate perform all necessary connections
echipamente care necesită conexiune. between both equipment’s that need
Furnizorul trebuie să efectueze cablarea între connection. The supplier shall
echipament și priza dulapului. perform the cabling between the
equipment and the closet outlet.
H. Se va realiza o implicare a părților A very high implication for
interesate pentru a obține toate cerințele în Stakeholder engagement shall be
ceea ce privește necesitățile de cablare, performed in order to get all
adresarea, VLAN-urile și lățimea de bandă. requirements in terms of cabling
necessities, addressing, VLANs and
bandwidth.

2.2.4.1.2 Vertical LAN and WAN Cabling/cablarea vertical LAN si WAN

A. Multimod sau mod unic (în funcție de Multi-mode or single mode


lățimea de bandă și distanță) pentru structura (depending on bandwidth and
verticală și WAN. Acest FO și instalarea sa se distance) for vertical and WAN
vor furniza in acest contract. backbone. This FO and its installation
is within this scope
B. Rețeaua multiplă a backbone network este
The multiple dual ring fibre optic
formată dintr-un cablu de fibră optică A & B.
backbone network consists of an A &
Cablurile inelare conținute în rețelele cu inel
B fibre optic cable. The ring cables
dublu au un număr de miez identic.
contained in the dual ring networks
have an identical core count.

05/05/2021 32
C. Clădirile vor fi prevăzute cu un inel Buildings shall be provided with a dual
backbone dublu pentru a susține cele două ring backbone cable to support the
cabluri. Un cablu este furnizat de la fiecare two feeder cables. A feeder cable is
inel dublu la fiecare intrare a clădirii de la provided from each dual ring to each
diverse îmbinări. Aceste puncte de intrare ale building entry from diverse splices.
clădirii sunt fie localizate în interiorul, fie These building entry points are then
conectate direct la camerele de distribuție a either located within or connected
clădirii prin intermediul a cel puțin două directly to the building distribution
douăzeci și patru (24) de cabluri de fibră rooms via a minimum of two twenty
optică cu nuclee direcționate separat de four (24) core fibre optic cables routed
diferite camine de vizitare, în aceeași clădire, separately from different manholes,
pentru a obține o diversitate maximă a căilor. within the same building in order to
achieve maximum pathway diversity.
D. Sistemul de cabluri din fibră optică trebuie
The backbone optical fibre cable
să fie format dintr-un tub liber, de capacitate
system shall consist of high capacity,
mare, neconductiv, multi-core, cu pierderi
loose tube, nonconductive, multi-core,
reduse, blocare a apei, rezistent la rozătoare,
low loss, dry water blocking, rodent
armare di-electrică a firelor de aramidă, tub
resistant, aramid yarn di-electric
liber, fluorură de poliviniliden (PVDF) umplută
armouring, loose tube, gel filled
cu gel sau înveliș din polietilenă de înaltă
polyvinylidene fluoride (PVDF) or high
densitate (HDPE), cablu interior / exterior.
density polyethylene (HDPE) sheath,
inside/outside plant cable.

E. Furnizorul va include: Supplier shall include within their


scope:
• Patch Cord F.O. Duplex LC / LC. OM3  Patch Cord F.O. LC/LC Duplex.
Multimode 50/125. 1/2 / 3m;
OM3 Multimode 50/125. 1/2/3m;

• Patch Cord F.O. Duplex LC / LC. OS2 Single  Patch Cord F.O. LC/LC Duplex.

mode 9/125. PC. 1/2 / 3m; OS2 Single mode 9/125. PC.
1/2/3m;
 All necessary patch panels and
• Toate panourile de patch-uri și cutiile de
îmbinare necesare; splicing boxes;
 All necessary racks for the
• Toate rack-urile necesare pentru instalarea
network installation;
rețelei;
• Toate echipamentele active necesare.  All necessary active equipment.

05/05/2021 33
2.2.4.1.3 FO Ring Cabling/cablarea inelului de fibra optica

A. Instalarea și cablrea inelului FO se va The FO Ring Cabling deployment and


furniza in acest contract, deci furnizorul installation is under the scope of this
rețelei trebuie să ia în considerare toate contract, so the network supplier shall
cerințele tehnice pe care trebuie să le consider all technical requirements
respecte cablul și va calcula numărul adecvat that the cable shall follow and shall
de standuri FO ale proiectului / soluției finale. calculate the appropriate number of
FOs stands of the final design/solution.
B. Cerințele FO pentru inel sunt :
The FO requirements for the ring are :
• Cablu LSZH I / A-DQ (ZN = B) H, G.652.D,
24-fibre Single Mode OS2 (Fără miez  Cable LSZH I/A-DQ(ZN=B)H,
metalic); G.652.D, 24-fibers Single mode
• Se vor instala două cabluri conform OS2 ( No metal core);
specificațiilor de mai sus.  Two cables of the specifications
above shall be installed.

C. Furnizorul va include în domeniul de Supplier shall include within their


aplicare: scope:
• Patch Cord F.O. Duplex LC / LC. OM3  Patch Cord F.O. LC/LC Duplex.
Multimode 50/125. 1/2 / 3m; OM3 Multimode 50/125. 1/2/3m;
 Patch Cord F.O. LC/LC Duplex.
• Patch Cord F.O. Duplex LC / LC. OS2 Single OS2 Single mode 9/125. PC.
mode 9/125. PC. 1/2 / 3m; 1/2/3m;
 All necessary patchpannel and
• Toate panourile și cutiile de conexiuni splicing boxes;
necesare;  All necessary racks or outdoor
• Toate rack-urile sau cutiile de conexiuni boxes for the network installation
necesare pentru instalarea în rețea a of the different nodes of the FO
diferitelor noduri ale inelului FO (de exemplu, ring ( for example, the rack/mini
rack / mini rack care trebuie instalat în rack to be installed within the
shelter-ul Navaids); Navaids shelter);
• Toate echipamentele active necesare.  All necessary active equipment.

05/05/2021 34
2.2.4.2 Racks/Rack-uri

A. Camerele tehnice vor fi echipate cu rack- Technical Rooms shall be equipped


uri de 19”. Dacă nu este recomandat altfel de with 19" racks. Unless recommended
producător, toate echipamentele active vor fi by the manufacturer, all active
instalate în aceste rack-uri. equipment will be installed in these
racks.
• Dimensiuni minime: 800mm x 800mm;
 Minimum Dimensions: 800mm x
800mm;
• Alte dimensiuni: 800mm x 1000mm sau
 Other Dimensions: 800mm x
1200mm pentru echipamente active în unele
1000mm or 1200mm for active
cazuri;
equipment in some cases;
• Înălțime minimă: 42 U;
 Minimum Height: 42 U;
• Sertare optice;
 Optic drawers;
• Panouri de trecere prin cablu;
 Cable-pass panels;
• Ptch paneluri RJ-45;
 RJ-45 connector patch panels;
• Două (2) Power Distribution Units (PDU)
 Two (2) Power Distribution Units
conectate în două (2) circuite diferite;
(PDUs) connected in two (2)
different circuits;
• Accesul la echipament trebuie protejat
 Access to the equipment shall be
printr-o încuietoare cu cheie.
protected by a key lock.

B. Toate celelalte materiale pentru instalarea


All other equipment to install the
echipamentului de rețea trebuie furnizate de
network equipment shall be provided
furnizor
by the supplier
• Mini rack-uri sau rack-uri montate pe
perete;  Mini racks or wall mounted racks;
• Cutii de exterior.  Outdoor Boxes.

2.2.4.3 Core Switches/comutatoare de baza

A. Toate switch-urile de bază trebuie All core switches shall be connected to


conectate între ele într-o retea complet each other in a fully redundant partial
redundantă. Fiecare Core Switch trebuie să mesh. Each Core switch shall be
fie conectat la cel puțin două (2) alte Core connected to at least two (2) other

05/05/2021 35
Switch-uri. Toate interfețele de Core Switch Core switches. All Core switch
trebuie să fie de cel puțin 10 GBASE-X. interfaces shall be at least 10GBASE-X.

B. Toate conexiunile între Core și între Core și


Distribution/Aggregation switches trebuie să All connections between Core and
utilizeze load balancing. between Core and
Distribution/Aggregation switches
C. Core Switch-urile trebuie să accepte VLAN shall utilize load balancing.
(IEEE 802.1Q). Trebuie sa permita un minim The Core switches shall support VLAN
de 4096 VLAN-uri. (IEEE 802.1Q). A minimum of 4096
VLAN’s shall be supported.
D. Core switches trebuie să poată fi montate
The core switches shall be mountable
într-un rack standard de 19”.
in 19-inch standard rack.

• Date minime de performanță:  Minimum performance data:


o +400 mpps Layer 3 forwarding; o +400 mpps Layer 3
o +50.000 intrări MAC; forwarding;
o +128.000 rute. o +50.000 MAC entries;
o +128.000 routes.
• Un switch trebuie să suporte o  A switch fabric capable of
lățime de bandă de minim 250 Gbps. supporting a minimum of 250
Gbps bandwidth.
• Un backplane non-blocant cu  A non-blocking backplane with
încărcarea completă a tuturor full load of all switching modules-
modulelor de comutare între module between modules and in case of
și în cazul trunkingului inter-module. inter-module trunking.
E. Core switches trebuie să fie echipate cu The Core switches shall be equipped
surse de alimentare redundante care sa fie with redundant hot-swappable power
hot-swappable pentru a fi conectate la două supplies to be connected to two
circuite diferite de distribuție a energiei. different power distribution circuits.
F. Core switches trebuie să aibă suport pentru The Core switches shall have
redundanță / failover care include Virtual redundancy/failover support that
Router Redundancy Protocol (VRRP sau includes Virtual Router Redundancy
similar) pe module de rutare, motoare de Protocol (VRRP or similar) on routing
supraveghere hot-swappable, module de modules, hot-swappable supervisor
rutare și carduri de linie, precum și tăvi de engines, routing modules and line
ventilator înlocuibile. cards as well as replaceable fan-trays.

05/05/2021 36
G. Core switch-urile trebuie să se poată opri The Core switches shall be able to
automat în caz de supraîncălzire. automatically shut down in case of
overheating.

The Core switches shall be able to


H. Core switch-urile trebuie să poată rezista
withstand a Denial of Service (DoS)
unui atac Denial of Service (DoS) fără o
attack without significant performance
degradare semnificativă a performanței.
degradation.

I. Core switch-urile trebuie să accepte The Core switches shall support full
funcționalități complete de rutare atât pentru routing functionality for both IPv4 and
IPv4, cât și pentru IPv6. IPv6.
J. Protocoalele de rutare acceptate includ The supported routing protocols shall
Static, Open Shortest Path First (OSPF), Label include Static, Open Shortest Path First
Distribution Protocol (LDP) și Multiprotocol - (OSPF), Label Distribution Protocol
Border gateway protocol (MP-BGPv4). (LDP) and Multiprotocol – Border
gateway protocol (MP-BGPv4).
K. OSPF, LDP și MP-BGPv4 vor suporta
OSPF, LDP and MP-BGPv4 shall
autentificarea MD5.
support MD5 authentication.
L. Comutarea etichetelor multi-protocol
(MPLS) va fi suportata. Multi-Protocol Label Switching (MPLS)
shall be supported.
M. MPLS (LSP) Ping și TraceRoute vor fi MPLS (LSP) Ping and TraceRoute shall
suportate. be supported.
N. Listele de acces vor fi configurabile pentru
Access Lists shall be configurable for
VLAN-uri, porturi, routere și adrese MAC.
VLANs, Ports, Routers and MAC
addresses.

O. Resource reservation protocol (RSVP) Resource reservation protocol (RSVP)


trebuie activat în rețea. Acesta va fi utilizat should still be enabled in the network
pentru MPLS Traffic Engineering (TE). Pe de o though. It shall be used for MPLS
parte, rețeaua nu trebuie să aibă congestie, Traffic Engineering (TE). On one hand,
dar pe de altă parte, există întotdeauna mai the network should not be congestion
multe legături între orice switch-uri din rețea. free, but on the other hand, there is
TE va fi utilizat pentru a modela și direcționa always more than one link between
traficul de-a lungul celei mai bune căi din any switches in the network. TE shall
rețea la un moment dat. Dacă, de exemplu, be used to shape and steer the traffic
există o aglomerație pe o legătură între două along the best path in the network at
Core switch-uri, TE va direcționa automat any given time. If for example there is

05/05/2021 37
trafic suplimentar printr-o altă cale pentru a congestion on a link between two
se asigura că traficul este tratat în Core switches, TE shall automatically
conformitate cu parametrii săi de Service route additional traffic through
Level Agreements(SLA). Core switch-urile another path to ensure that the traffic
trebuie, prin urmare, să accepte RSVP-TE. is treated according to its Service Level
Agreements (SLA) parameters. The
Core switches shall therefore support
RSVP-TE.
P. Re-Routing rapid (FRR) al tunelurilor TE în
Fast Re-Routing (FRR) of TE tunnels in
cazul unei link failure este o cerință.
case of a link failure is a requirement.

2.2.4.4 Aggregation /Distribution Switches/ Comutatoare de agregare / distribuție

A. Aggregation/Distribution switches vor Aggregation/Distribution switches


colecta linkuri ascendente 1000BASE-X și shall collect 1000BASE-X and
10GBASE-X de la comutatoare de acces și vor 10GBASE-X uplinks from Access
transmite semnale Ethernet de 10GBASE-X switches and transmit 10GBASE-X
către două Core switch-uri. Ethernet signals to two Core switches.
B. Toate conexiunile dintre nucleul și switch-
All connections between Core and
urile de agregare / distribuție trebuie să
Aggregation/Distribution switches
utilizeze load balancing.
shall utilize load balancing.

C. Toate conexiunile dintre switch-urile de All connections between


agregare / distribuție și switch-urile de acces Aggregation/Distribution switches
trebuie să utilizeze load balancing. and Access switches shall utilize load
balancing.
D. Conexiunile de la fiecare Distribution The connections from each
switch la două Core switch-uri separate fizic Distribution switch to two physically
(situate în fiecare centru de date) vor fi separated Core switches (located in
interfețe SR / LR / ER de 10 Gbit / s. Dacă sunt each Data Centre) shall be 10 Gbit/s
necesare mai mult de 10 Gbit / s, interfețele SR/LR/ER interfaces. If more than 10
vor fi grupate ca un singur canal logic Gbit/s are needed, the interfaces shall
folosind LACP. be bundled as one logical channel
using LACP.

05/05/2021 38
E. Fiecare Switch de distribuție va fi asociat cu Every Distribution switch shall be
un alt Switch de distribuție care conectează paired with another Distribution switch
aceleași Switch-uri de acces. connecting the same access switches.

Every Aggregation switch shall be


F. Fiecare Switch de agregare va fi asociat cu
paired with another Aggregation
un alt Switch de agregare conectat la aceeași
switch connected to the same pair of
pereche de Switch-uri de bază.
Core Switches.

G. Switch-urile de acces ar trebui să se Access switches should connect to the


conecteze la perechea de Switch-uri Aggregation/Distribution switch pair
Agregare / Distribuție printr-o conexiune through a 1000BASE-X or 10GBASE-X
1000BASE-X sau 10GBASE-X la fiecare Switch. connection to each switch.
Switch-urile de distribuție trebuie să accepte Distribution switches shall support
interfețe modulare (SFP sau GBIC). modular interfaces (SFP or GBIC).
H. Switch-urile de agregare / distribuție The Aggregation/Distribution switches
trebuie să accepte VLAN (IEEE 802.1Q). shall support VLAN (IEEE 802.1Q). A
Trebuie acceptate minimum 4096 VLAN-uri. minimum of 4096 VLANs shall be
supported.
I. Switch-urile de agregare / distribuție
The Aggregation/Distribution switches
trebuie să accepte LACP (IEEE 802.3ad).
shall support LACP (IEEE 802.3ad).

J. Switch-urile de agregare / distribuție The Aggregation/Distribution switches


trebuie să fie montabile într-un rack standard shall be mountable in 19-inch standard
de 19”. rack.
• Date minime de performanță:  Minimum performance data:
o +400 mpps Layer 3 forwarding; o +400 mpps Layer 3
o +50.000 intrări MAC: forwarding;
o +128.000 rute. o +50.000 MAC entries:
o +128.000 routes.
• Switch capabil să suporte o lățime  A switch fabric capable of
de bandă de minim 250Gbps; supporting a minimum of
250Gbps bandwidth;
• Un backplane non-blocant cu  A non-blocking backplane with
încărcarea completă a tuturor full load of all switching modules-
modulelor de comutare între module between modules and in case of
și în cazul trunkingului inter-module. inter-module trunking.
K. Switch-urile de agregare / distribuție The Aggregation/Distribution switches
trebuie să fie echipate cu surse de alimentare shall be equipped with redundant hot-

05/05/2021 39
redundante care pot fi schimbate la cald swappable power supplies to be
pentru a fi conectate la două (2) circuite de connected to two (2) different power
distribuție a energiei diferite. distribution circuits.
L. Switch-urile de agregare / distribuție
The Aggregation/Distribution switches
trebuie să poată opri automat în caz de
shall be able to automatically shut
supraîncălzire.
down in case of overheating.
M. Switch-urile de agregare / distribuție
trebuie să poată rezista unui atac Denial of The Aggregation/Distribution switches
Service (DoS) fără o degradare semnificativă shall be able to withstand a Denial of
a performanței. Service (DoS) attack without significant
performance degradation.
N. Switch-urile de agregare / distribuție The Aggregation/Distribution switches
acceptă funcționalități complete de rutare shall support full routing functionality
atât pentru IPv4, cât și pentru IPv6. for both IPv4 and IPv6.
O. Protocoalele de rutare acceptate trebuie
The supported routing protocols shall
să includă Static, OSPF, LDP și MPBGPv4.
include Static, OSPF, LDP and
MPBGPv4.

P. OSPF, LDP și MP-BGPv4 vor accepta OSPF, LDP and MP-BGPv4 shall
autentificarea MD5. support MD5 authentication.

Multi-Protocol Label Switching (MPLS)


Q. Multi-Protocol Label Switching (MPLS) va shall be supported.
fi acceptată.
MPLS (LSP) Ping and TraceRoute shall
R. MPLS (LSP) Ping și TraceRoute vor fi
be supported.
acceptate.
Access Lists shall be configurable for
S. Listele de acces vor fi configurabile pentru VLANs, Ports, Routers and MAC
VLAN-uri, porturi, routere și adrese MAC. addresses.

RSVP must be enabled in the network


T. RSVP trebuie totuși activat în rețea. Acesta though. It shall be used for MPLS
va fi utilizat pentru MPLS Traffic Engineering Traffic Engineering (TE).
(TE).
On one hand, the network should not
U. Pe de o parte, rețeaua nu ar trebui să aibă
be congestion free, but on the other
congestie, dar pe de altă parte, există
hand, there is always more than one
întotdeauna mai multe legături între orice
link between any switches in the
switch din rețea. TE va fi utilizat pentru a
network. TE shall be used to shape
modela și direcționa traficul de-a lungul celei
and steer the traffic along the best
mai bune căi din rețea la un moment dat.

05/05/2021 40
Dacă, de exemplu, există o aglomerație pe o path in the network at any given time.
legătură între un switch de agregare și switch If for example there is congestion on a
principal, TE va redirecționa automat trafic link between an Aggregation switch
suplimentar printr-o altă cale pentru a se and Core switch, TE shall automatically
asigura că traficul este tratat în conformitate route additional traffic through
cu parametrii SLA. another path to ensure that the traffic
is treated according to its SLA
parameters.
V. Prin urmare, switch de agregare /
The Aggregation/Distribution switches
distribuție va suporta RSVP-TE.
shall therefore support RSVP-TE.

W. Reorientarea rapidă (FRR) a tunelurilor TE Fast Re-Routing (FRR) of TE tunnels in


în cazul unei link failure este o cerință. case of a link failure is a requirement.

The Aggregation/Distribution switches


X. switch-urile de agregare / distribuție vor shall support Spanning Tree including
suporta Spanning Tree, inclusiv IEEE 802.1w IEEE 802.1w Rapid Spanning Tree
Rapid Spanning Tree (RSTP) pentru loop (RSTP) for loop-prevention and IEEE
prevention și IEEE 802.1s Multiple Spanning 802.1s Multiple Spanning Tree
Tree Protocol (MSTP) sau similar pentru layer Protocol (MSTP) or similar for layer 2
2 load balancing pe legături redundante. load balancing over redundant links.

2.2.4.5 Access Switches/comutatoare de acces

A. Access Switches trebuie să furnizeze Access Switches shall provide


porturi Ethernet 10/100 / 1000BASE-T către 10/100/1000BASE-T Ethernet ports to
dispozitivele sau serverele utilizatorului atașat attached end user devices or servers
și 1000BASE-X sau 10GBASE-X redundante (în and redundant 1000BASE-X or
funcție de previziunea încărcării) la stratul de 10GBASE-X (depending on load
distribuție / agregare. prevision) to the
Distribution/Aggregation layer.
B. Toate switch-urile trebuie să aibă cel puțin
All switches shall have a minimum of
două (2) porturi de legătură în sus către
two (2) uplink ports to the
stratul de distribuție / agregare.
Distribution/Aggregation layer.

C. Unele echipamente ar trebui să fie Some end user equipment should


conectate prin fibră, fie pentru că sunt need to be connected through fibre
either because it is located too far

05/05/2021 41
amplasate prea departe pentru cablarea cu away for twisted pair cabling or
perechi răsucite, fie pentru că echipamentul because the equipment is located
este situat în exterior. outside.
D. Toate switch-urile de acces vor fi
All Access switches shall be connected
conectate la două (2) comutatoare de
to two (2) Aggregation/Distribution
agregare / distribuție cu interfețe Ethernet
switches with 1000BASE-X or
1000BASE-X sau 10GBASE-X.
10GBASE-X Ethernet interfaces.

E. Toate dispozitivele sau serverele trebuie să All end user devices or servers shall be
fie conectate la switch-uri de acces cu connected to the Access switches with
legături uplink 10/100 / 1000BASE-T sau 10/100/1000BASE-T or 10GBASE-X
10GBASE-X. uplinks.
F. Unele servere au nevoie de o lățime de Some servers need more bandwidth
bandă mai mare decât poate oferi o legătură than one 10/100/1000BASE-T uplink
uplink 10/100 / 1000BASE-T și, prin urmare, can provide and may therefore be able
pot fi capabile să grupeze două sau mai to bundle two or more
multe interfețe 10/100 / 1000BASE-T prin IEEE 10/100/1000BASE-T interfaces through
802.3ad Link Aggregation. Prin urmare, IEEE 802.3ad Link Aggregation.
switch-ul de acces va suporta această Access switch shall therefore support
funcționalitate. this functionality.

All Access switches shall support


G. Toate switch-urile de acces trebuie să
Power over Ethernet (IEEE 802.3af) or
accepte Power over Ethernet (IEEE 802.3af)
preferably PoE+ (IEEE 802.3at) for
sau de preferință PoE + (IEEE 802.3at) pentru
Wireless Access Points, IP-telephones,
Wireless Access Points, telefoane IP, camere
IP-based cameras or similar.
bazate pe IP sau altele similare.
H. Pentru a minimiza riscul de bucle în rețea, To minimize the risk of loops in the
trebuie conectat un singur dispozitiv (o net, only one device (one MAC
singură adresă MAC) la porturile switch-ului, address) shall be connected to end
cu excepția cazului în care dispozitivul user switch ports unless the connected
conectat este un telefon IP cu porturi de device is an IP phone with built in
comutare încorporate. Configurația switch- switch ports. The switch configuration
ulu trebuie să ia în considerare acest lucru. shall take this into account. If more
Dacă mai multe dispozitive sunt conectate la than one device is connected to a
un switch de comutare, portul trebuie să fie switch port, the port shall go in
închis administrativ timp de cinci (5) minute și administrative shutdown for five (5)
se va transmite un trap SNMP (Simple minutes, and a Simple network
Management Protocol (SNMP) trap

05/05/2021 42
Network Management Protocol) care va shall be transmitted detailing the
detalia evenimentul. event.
I. Switch-urile de acces trebuie să accepte
The Access switches shall support
VLAN (IEEE 802.1Q). Trebuie acceptate
VLAN (IEEE 802.1Q). A minimum of
minimum 4096 VLAN-uri.
4096 VLANs shall be supported.
J. Switch-urile de acces trebuie să accepte
LACP (IEEE 802.3ad). The Access switches shall support
LACP (IEEE 802.3ad).
K. Switch-urile de acces trebuie să poată fi The Access switches shall be
montate într-un rack standard de 19 “. mountable in a 19-inch standard rack.
L. Switch-urile de acces trebuie să includă un
The Access switches shall include a
backplane non-blocant.
non-blocking backplane.

M. Switch-urile de acces trebuie să furnizeze The Access switches shall provide


surse de alimentare redundante care să fie redundant power supplies to be
conectate la cel puțin două (2) circuite connected to at least two (2) different
diferite de distribuție a energiei. power Distribution circuits.
N. Switch-urile de acces trebuie să poată opri The Access switches shall be able to
automat în caz de supraîncălzire. automatically shut down in case of
overheating.
O. Switch-urile de acces trebuie să utilizeze
The Access switches shall employ
controlul furtunilor de difuzare, multicast și
broadcast-, multicast- and unicast
unicast pentru a preveni stațiile finale defecte
storm control to prevent faulty end
să degradeze performanța switch-ului.
stations from degrading the switch
performance.

P. În mod similar, Switch-urile de acces Similarly, the Access switches shall be


trebuie să poată rezista unui atac Denial of able to withstand a Denial of Service
Service (DoS) fără o degradare semnificativă (DoS) attack without significant
a performanței. performance degradation.
Q. Listele de acces trebuie să fie configurabile Access Lists shall be configurable for
pentru VLAN-uri, porturi și adrese MAC. VLANs, ports and MAC-addresses.

Access switches shall be able to


R. Switch-urile de acces trebuie să poată
classify and remark the data traffic to
clasifica și remarca traficul de date la valorile
the Differentiated Services Code Point
Differentiated Services Code Point (DSCP)
(DSCP) values determined in the QoS
determinate în QoS. Marcajele DSCP nu vor fi
schedule. DSCP markings shall not be
acceptate la porturile de intrare la Switch-

05/05/2021 43
urile de acces, cu singura excepție în cazul în accepted at the ingress ports to the
care telefonul IP are un switch încorporat Access switches, with the only
unde se poate face marcarea DSCP. exception being where the IP Phone
has a built-in switch where DSCP
marking can be done.
S. Switch-urile de acces trebuie să accepte
The Access switches shall support
Spanning Tree, inclusiv IEEE 802.1w Rapid
Spanning Tree including IEEE 802.1w
Spanning Tree (RSTP) pentru prevenirea
Rapid Spanning Tree (RSTP) for loop-
loop-urilor și IEEE 802.1s Multiple Spanning
prevention and IEEE 802.1s Multiple
Tree Protocol (MSTP) sau similar pentru layer
Spanning Tree Protocol (MSTP) or
two (2) load balancing peste legături
similar for layer two (2) load balancing
redundante.
over redundant links.

T. Switch-urile de acces trebuie să accepte The Access switches shall support IEEE
IEEE 802.1X pentru securitate bazată pe 802.1X for port-based security on end
porturi pe porturile utilizatorului final. Toate user ports. All end user ports shall be
porturile utilizatorului final vor fi atribuite în assigned to VLANs dynamically based
mod dinamic VLAN-urilor pe baza on the 802.1X authentication unless
autentificării 802.1X, cu excepția cazului în the port is manually configured for a
care portul este configurat manual pentru o specific VLAN.
anumită VLAN.
U. Toate porturile utilizatorului final ale
All Access switch end user ports shall
Switch-urilor de acces trebuie să accepte IEEE
support IEEE 802.1p. 802.1p shall be
802.1p. 802.1p trebuie utilizat pentru a se
used to ensure that IP telephones are
asigura că telefoanele IP sunt introduse în
put into the proper VLAN and gets the
VLAN adecvat și primesc tratamentul QoS
proper QoS treatment.
adecvat.
V. Protocol Independent Multicast va fi Protocol Independent Multicast shall
acceptat, inclusiv Protocol Independent be supported including Protocol
Multicast (PIM) Sparse Mode. Independent Multicast (PIM) Sparse
Mode.
W. Internet Group Management Protocol Internet Group Management Protocol
(IGMP) Snooping va fi acceptat pentru IP (IGMP) Snooping shall be supported
multicast client joins and leaves. for fast IP multicast client joins and
leaves.

05/05/2021 44
X. Dynamic Host Configuration Protocol Dynamic Host Configuration Protocol
(DHCP) Snooping trebuie să fie acceptat (DHCP) Snooping shall be supported
pentru a evita falsificarea serverelor DHCP. to avoid spoofing of DHCP servers.

The Access switches shall be able to


Y. Switch-urile de acces trebuie să poată
mirror in a controlled manner traffic
reflecta în mod controlat traficul pe un port
on one port or on a group of ports or
sau pe un grup de porturi sau pe un întreg
on an entire VLAN to another port or
VLAN către un alt port sau un alt VLAN
another VLAN for monitoring and
pentru monitorizare și alte scopuri.
other purposes.

2.2.5 INTEGRATION / INTERFACE REQUIREMENTS/CERINTE DE INTERFATA

A. Acest sistem ar trebui să ofere servicii This system should provide service to
tuturor sistemelor IT existente în aeroport. all IT systems existing in the airport.

The integration diagram below shows


B. Diagrama de integrare de mai jos prezintă
all integration necessities for the
toate necesitățile de integrare pentru
Network System:
sistemul de rețea:
Particularly, the Supplier shall consider
C. În special, Furnizorul va lua în considerare all necessary coordination in order to
toate coordonările necesare pentru a realiza obtain all necessities and
toate necesitățile și cerințele pentru instalarea requirements to install the necessary
cablajului / conexiunilor necesare între cabling/connections between system
echipamentele de sistem și integrări: equipment and integrations:
• Lățime de bandă;  Bandwidth;
• Cablul rulează între echipamente;  Cable runs between equipment;
• configurație VLAN;  VLAN configuration;
• adresarea IP;  IP addressing;
• Etc.  Etc.

05/05/2021 45
INTERNET

INTERLINKS VREC VHF EVHF VCCS ATIS CFR CMS


between Brasov
and RVT

FO RING ATC NETWORK

BRASOV AIRPORT
NETWORK
ILS DVOR AIS AWOS MCS

Figura 3: LAN/WAN Integration/Integrarea LAN WAN

2.2.6 IP ADDRESS SCHEME/SCHEMA ADRESEI IP

A. Furnizorul LAN / WAN va fi responsabil A. The LAN/WAN Supplier shall be


pentru furnizarea și menținerea unui sistem responsible for providing and
de adresare IP care va necesita aprobarea maintaining an IP addressing scheme
clientului în conformitate cu politicile LAN ale which shall require client approval in
aeroportului. accordance with LAN policies of the
Airport.

2.2.7 SOFTWARE REQUIREMENTS/CERINTE SOFTWARE

A. Pachetele software comerciale trebuie să Commercial software packages shall


aibă documente de înregistrare și licențiere have registration and licensing
care să indice Beneficiarul ca proprietar al documentation filed indicating the
software-ului. Beneficiary as the owner of the
software.
B. Software-ul licențiat complet va fi furnizat
Fully licensed software shall be
pentru utilizare în mediul operațional live.
provided for use in the live operational
environment.
C. Software-ul dezvoltat va fi licențiat
Beneficiarului. Această licență va include Software developed shall be licensed
toate codurile executabile, bibliotecă, obiect to the Beneficiary. This license shall
și cod sursă necesare pentru întreținerea și include all executable, library, object,

05/05/2021 46
modificarea produsului livrat. Aceste and source code required to maintain
informații vor fi livrate pe CD-ROM. Se vor and modify the delivered product.
include toate compilatoarele, instrumentele, This information shall be delivered on
utilitarele etc. necesare pentru a crea codul CD-ROM. All compilers, case tools,
executabil. utilities, etc. that are needed to create
the executable code shall be included.
D. Se vor furniza licențe software comerciale
Perpetual commercial off-the-shelf
perpetue, disponibile la distanță.
software licenses shall be provided.

E. Asistența software se acordă în termenii Software support shall be granted


garanției. within the terms of the warranty.
F. Toate interfețele de utilizare ale software- All software user interfaces shall use
ului vor folosi limba engleză ca implicit. the English language as default.

Systems shall handle dates using


G. Sistemele vor gestiona datele folosind
Gregorian calendar.
calendarul gregorian.
H. Suportul software include upgrade-uri la Software support shall include
versiuni mai noi de software, după caz. upgrades to newer versions of
software where appropriate.
I. Un kit de dezvoltare software va fi furnizat A Software Development Kit shall be
împreună cu fiecare aplicație. provided with each application.

2.2.8 HARDWARE REQUIREMENTS/CERINTE HARDWARE

A. Toate componentele trebuie să fie de All components shall be current


producție curenta. production products.
B. Toate componentele trebuie să fie listate
All components shall be UL listed or CE
UL sau marcate CE.
marked.

C. Toate componentele din sistem trebuie să All components within the system shall
fie de înaltă calitate profesională de la. be of a high, professional quality.

All system components (where


D. Toate componentele sistemului (acolo reasonable possible) shall be
unde este posibil) trebuie să fie fabricate de manufactured from the same
la același producător. manufacturer.

05/05/2021 47
E. Hardware-ul trebuie să fie off-the-shelf, de The hardware shall be off-the-shelf,
ultimă generație și de calitate comercială state-of-the-art and of proven
dovedită. commercial quality

F. Hardware-ul trebuie să fie proiectat și Hardware shall be designed and built


construit pentru a interfața cu componentele to interface with standard
standard, inclusiv rack-urile (așa cum sunt components, including racking (as
preinstalate în Data Centres și camerele de pre-installed within the Data Centres
comunicare), rafturile, hardware-ul de and comms rooms), shelving, support
susținere (șuruburi, piulițe, cleme etc.), hardware (screws, bolts, nuts, clips,
interfața cablului, conectori, ansambluri de etc.), cable interface, connectors,
cabluri etc. wiring assemblies, etc.
G. Hardware-ul trebuie să includă, acolo Hardware shall, where applicable,
unde este cazul, indicatori (lumini, LED-uri include indicators (lights, LEDs, etc.) to
etc.) pentru a indica pornirea, activitatea denote power-on, systems activity,
sistemului, defecțiunea sistemului și system failure and system trouble, as
defecțiunile sistemului, precum și indicatori well as discrete indicators appropriate
discreți corespunzători fiecărui dispozitiv și for each device and device class.
clasă de dispozitiv.
Hardware that includes a processor
H. Hardware-ul care include un procesor
such as a PC shall be capable of being
precum un PC trebuie să poată fi repornit de
remotely rebooted and should be
la distanță și ar trebui să poată fi oprit și
capable of being remotely stopped
pornit de la distanță
and started

I. Hardware-ul trebuie să fie etichetat Hardware shall be suitably and clearly


corespunzător și clar cel puțin cu numele labelled at minimum with the
producătorului, numărul produsului, numărul manufacturer´s name, the product
de serie și data de fabricație și numărul number, serial number, and date of
activului. manufacture and asset number.
J. În cazul plasării greșite a unităților In case of misplacement of
interschimbabile, nu se vor produce daune interchangeable units, no damage
echipamentului și trebuie detaliate metodele shall be caused to the equipment and
de protecție utilizate în acest sens. the protection methods employed in
that regard shall be detailed.
K. Toate datele hardware trebuie să fie
All hardware data shall be coordinated
coordonate cu desenele de proiectare,
with the design drawings, bills of

05/05/2021 48
cantitatile de materiale și baza documentelor material and basis of quantity
de cantitate. documents.
L. Trebuie furnizat hardware complet licențiat
Fully licensed hardware shall be
pentru utilizare în mediul operațional live.
provided for use in the live
Operational environment.

M. Componentele, software-ul și tehnologiile The components, software and


care trebuie utilizate în proiectare trebuie să technologies to be employed in the
fie bine dovedite și să fie conforme cu design should be well proven and
standardele deschise internaționale și definite conform to the international and
de industrie. industry defined open standards.
N. Furnizarea de echipamente (hardware, The provision of the equipment
software, middleware, firmware etc.) și (hardware, software, middleware,
materiale ar trebui să fie conform firmware, etc.) and materials should be
standardelor internaționale și definite de of international and industry defined
industrie. Echipamentele și materialele care standards. The equipment and
urmează să fie instalate și furnizate trebuie să materials to be installed and supplied
fie de cele mai noi modele / standarde should be of the latest
înainte de livrare, iar aceste prevederi ar models/standards prior to delivery,
trebui să fie ușor de actualizat la noile and these provisions should be easily
standarde utilizate în orice moment. upgradeable to the new standards in
use at any time.
O. Toate sistemele trebuie să funcționeze în
All systems must operate under
condițiile de mediu ale României.
Romanian´s environmental conditions.

P. Proiectarea finală a rețelei și cantitățile de Final network design and HW


HW vor fi definite de furnizor în etapa de quantities shall be defined by the
proiectare, având în vedere toate sistemele supplier in the design stage,
care trebuie incluse în rețeaua LAN / WAN și considering all systems to be included
toate cerințele părților interesate. within the LAN/WAN and all
stakeholder requirements.
Q. Technical Workstation vor fi instalate în Technical Workstations to be installed
camera de control tehnic adiacentă camerei within the technical control room
tehnice din fiecare instalație. adjacent to the technical room in each
facility.

05/05/2021 49
2.2.9 PERFORMANCE REQUIREMENTS/CERINTE DE PERFORMANTA

Switch-urile care trebuie furnizate trebuie să The switches to be provided shall fulfil the
îndeplinească următoarele cerințe: following requirements:

All switches shall be identifiable to


A. Toate Switch-urile trebuie să fie
support maintenance technicians and
identificabile pentru a sprijini tehnicienii de
make easier administration from the
întreținere și pentru a facilita administrarea
control centre.
de la centrul de control.
For the switches to be installed in an
B. Pentru ca Switch-urile să fie instalate într- interior controlled environment, the
un mediu controlat interior, sistemul LAN LAN system shall be operational in an
trebuie să funcționeze la o temperatură a ambient air temperature between 15
aerului ambiant cuprinsă între 15 și 40 de to 40 degrees Celsius. IT rooms and
grade Celsius. Camerele IT și centrele de date Data Centres require this type of
necesită acest tip de mediu. environment.

For the switches to be installed in an


C. Pentru ca Switch-urile să fie instalate într- interior uncontrolled environment, the
un mediu interior necontrolat, Switch-urile switches shall support temperatures
trebuie să suporte temperaturi cuprinse între between 0 to 65 degrees Celsius.
0 și 65 de grade Celsius.

05/05/2021 50
2.2.9.1 Availability, Maintainability & Reliability/ Disponibilitate, întreținere și fiabilitate

Sistemul LAN trebuie să respecte următoarele


LAN system shall comply with the following
cerințe de redundanță, scalabilitate și
redundancy, scalability and reliability
fiabilitate.
requirements.

A. Disponibilitate: întregul sistem LAN trebuie Availability: The entire LAN system
să ofere o disponibilitate ridicată. Toate shall provide a high availability. All
configurațiile și datele utilizate de software configurations and data used by the
vor fi salvate zilnic pentru a preveni pierderea software shall be backed up on a daily
datelor. basis to prevent data loss.

System stability: The system provided


B. Stabilitatea sistemului: Sistemul furnizat shall be equipped with a UPS solution
trebuie să fie echipat cu o soluție UPS pentru to maintain the system stability. Any
a menține stabilitatea sistemului. Orice power variation should not affect the
variație de putere nu trebuie să afecteze quality of the picture nor the video
calitatea imaginii și nici caracteristicile video. features.

Usability: The organization of


C. Utilizare: Organizarea informațiilor de pe
information on the screen shall be
ecran trebuie să fie clară. Informațiile (Online
clear. The information (Online Help,
Help, Documentation) furnizate împreună cu
Documentation) provided with the
sistemul trebuie să fie clare și concise. The
system shall be clear and concise. The
Graphic User Interface trebuie să fie ușor de
Graphic User Interface shall be user
utilizat.
friendly.

D. Fiabilitate: sistemul furnizat trebuie să Reliability: The system provided shall


funcționeze 24 de ore pe zi. Sistemul LAN va work 24 hours a day. The LAN System
avea un MTBF ridicat, iar un MTTR redus va fi shall have a high MTBF, and a reduced
realizabil. MTTR shall be achievable.
E. Performanță / timp de răspuns: sistemul Performance / Response time: The
LAN va gestiona rata de biți de mare viteză în LAN system shall manage high speed
timp real. Timpul de răspuns trebuie să fie bit rate in real time. Response time
redus. shall be low.

The Supplier shall provide within the


F. Furnizorul va furniza în cadrul propunerii
proposal detailed information
informații detaliate cu privire la specificațiile
regarding technical specifications of
tehnice ale fiecărui echipament, materiale și
each of the proposed equipment,

05/05/2021 51
accesorii propuse, demonstrând integrarea / materials, and accessories
interfața dintre acestea. demonstrating integration /
interfacing amongst them.

The Mean Time Between Failures


G. Mean Time Between Failures(MTBF), Mean
(MTBF), Mean Time To Repair (MTTR),
Time To Repair (MTTR), Mean Time Between
Mean Time Between Critical Failures
Critical Failures (MTBCF) și cifrele de
(MTBCF) and Availability figures of all
disponibilitate ale tuturor echipamentelor
the equipment proposed should be
propuse trebuie furnizate și sistemul general,
provided and the overall system,
indicând metoda utilizată pentru calcul , cum
indicating the method used for the
ar fi MIL-HDBK-217. Dacă sunt ofertate valori
calculation, such as MIL-HDBK-217. If
de subsisteme MTBF, MTTR, MTBCF și
sub-system MTBF, MTTR, MTBCF, and
Disponibilitate, acestea vor fi adunate într-un
Availability numbers are submitted,
sistem global de MTBF, MTTR, MTBCF și
these shall be rolled up into an overall
Availability numbers. Numerele MTBF, MTTR
system MTBF, MTTR, MTBCF and
și MTBCF ale altor site-uri cu tipuri de
Availability numbers. The MTBF,
echipamente similare instalate ar trebui
MTTR, and the MTBCF numbers of
furnizate, astfel încât valorile propuse să
other sites with similar types of
poată fi verificate.
equipment installed should be
provided so the quoted numbers may
be verified.

H. Trebuie furnizată o listă de piese care sunt A list of parts which are unique to the
unice pentru sistem (cum ar fi comutatoarele system (such as switches or FO
sau transceiverele FO) și care, în caz de transceivers) and which in case of
defecțiune, ar fi considerate critice și ar cauza failure would be considered critical
o suspendare a serviciului. and cause a suspension of service
should be provided.
I. MTBF, MTTR, MTBCF și Availability numbers The MTBF, MTTR, MTBCF and
pentru echipamentele de comunicații și Availability numbers for the
subsistemele sale vor fi furnizate separat. communication equipment and its
subsystems should be provided
separately.

The Availability of the entire system


J. Disponibilitatea întregului sistem pe o
over a period of twelve (12) months
perioadă de douăsprezece (12) luni trebuie să
shall be at least 99.99%.
fie de cel puțin 99,99%.

05/05/2021 52
K. Proiectarea trebuie să includă Network The design shall include a Network
vendor resiliency pentru a evita cauza vendor resiliency to avoid common
comună a defecțiunilor. cause of failures.

The Safety Case of the entire network


L. Safety Case al întregii rețele va pune în
shall enforce the principle of avoiding
aplicare principiul evitării cauzei comune a
common cause of failures as far as
defecțiunilor, pe cât posibil.
possible.

M. Standardele de rețea specifice ATS vor fi ATS specific network standards shall
luate în considerare și aplicate proiectării be taken into consideration and
rețelei (de exemplu, EuroCAE ED-138), pentru applied to network design (e.g.
a sprijini sistemele ATS critice pentru misiune, EuroCAE ED-138), in order to support
cum ar fi radio, video RVT, telefon și date de mission critical ATS systems such as
surveillance. radio, RVT video, telephone and
surveillance data.
N. Sistemul va detecta automat o degradare The System shall automatically detect
a performanței rețelei, rezultând o degradare a a degradation in a network
a calității percepute a sistemelor ATS, cum ar performance resulting in a
fi video RVT sau radio AG, atunci când o degradation of perceived quality of
astfel de degradare are loc fără o pierdere the ATS systems, such as RVT video or
completă a conectivității rețelei. AG radio, when such a degradation
occurs without a complete loss of the
Network connectivity.

Based on the detection of the


O. Pe baza detectării evenimentului de
degradation event, the system shall:
degradare, sistemul va trebui sa:
 trigger a traffic class selective re-
• declanșeaze o redirecționare selectivă a routing if the required packet
clasei de trafic dacă nivelul de calitate de forwarding quality level is not
redirecționare a pachetelor nu este furnizat provided over the preferred
pe calea de comunicare preferată; communication path;

 automatically switchover each


• comute automat fiecare sistem ATS ATS system individually among
individual între toate legăturile de rețea the all available network links
disponibile (primar / de rezervă / terțiar). (primary/backup/tertiary).

05/05/2021 53
P. Dacă se utilizează SDN sau alte tehnologii If SDN or other application routing
de rutare a aplicațiilor, atunci aceste technologies are used, then such
funcționalități sunt în relație directă cu functionalities are in direct relation to
sistemele ATS și, prin urmare, dezvoltarea ATS systems and therefore the
software-ului trebuie să fie conformă cu ED- software development shall comply
153 SWAL3 pentru a fi suficient de sigură with ED-153 SWAL3 in order to be
pentru utilizare în Air Traffic Management. sufficiently safe for use in Air Traffic
Management.

There must not be overlay networks


Q. Nu trebuie să existe rețele suprapuse care
that invades the network and can
invadează rețeaua și care pot provoca o
cause a total network outage in case
întrerupere totală a rețelei în cazul unei
of a single AND double failure of the
singure și duble failure a suprapunerii VPN.
VPN overlay.

R. Nu trebuie să existe o instanță centrală There must not be a central instance


care să fie singura responsabilă pentru planul that is solely responsible for the data
de date și care poate provoca o întrerupere plane and can cause a total network
totală a rețelei în cazul unei întreruperi a outage in case of an orchestrator
acesteia. outage.
S. Sistemul va verifica în mod constant datele The System shall constantly check the
de performanță ale rețelei pentru a reveni network performance data to
automat la căile de comunicare preferate ale automatically revert to preferred
fiecărui sistem ATS, după ce nivelul de communication paths of each ATS
calitate de redirecționare a pachetelor este system, after the required packet
furnizat din nou de către rețea. forwarding quality level is provided
again by the network.

The required quality of packet


T. Calitatea necesară a redirecționării
forwarding shall be guaranteed per
pachetelor va fi garantată pe fluxul de trafic
traffic flow of each individual ATS
al fiecărui sistem ATS individual (de exemplu,
system (e.g. phone, radio, video, air
telefon, radio, video, supravegherea traficului
traffic surveillance, messaging, etc.).
aerian, mesagerie etc.).
U. Dacă calitatea legăturilor de rețea If the quality of available network links
disponibile (primar / de rezervă / terțiar) între (primary/backup/tertiary) between the
instalația RVT la distanță și aeroportul din remote RVT facility and the Brasov
Brașov este degradată dincolo de un nivel airport is degraded beyond a
predefinit, atunci sistemul va fi capabil să predefined level, then the system shall
degradeze automat o calitate a anumitor be able to automatically degrade a

05/05/2021 54
sisteme RVT, precum Fluxuri video RVT quality of certain RVT systems, such as
pentru a continua operațiunile RVT chiar și în RVT video streams to continue the RVT
situații de dezastru în rețea. operations even in cases of a disaster
network situations.
V. Dacă calitatea tuturor legăturilor de rețea
If the quality of all available network
disponibile între instalația RVT la distanță și
links between the remote RVT facility
aeroportul din Brașov este degradată dincolo
and the Brasov airport is degraded
de un nivel predefinit, atunci sistemul va
beyond a predefined level, then the
putea opri automat anumite sisteme de
system shall be able to automatically
camere RVT mai puțin critice.
switch off particular less critical RVT
camera systems.
W. Sistemul asigură monitorizarea end-to-
end a tuturor legăturilor de rețea pe baza The System shall provide end-to-end
măsurării parametrilor legăturii dintre diferite monitoring of all network links based
interfețe de sistem ATS. Sistemul trebuie să on measurement of link parameters
asigure măsurarea parametrilor de bază ai between different ATS system
rețelei, printre altele: interfaces. The System must ensure
• Întârziere; measurement of basic network
• Jitter; parameters, among others:
• Pierdere de pachete.  Delay;

 Jitter;

 Packet loss.
X. Monitorizarea sistemului va furniza The system monitoring shall provide
raportarea conformității ED-138 a rețelei the reporting for the ED-138
logice pentru serviciile ATM critice selectate. compliancy of the logical network leg
for the selected critical ATM services.

The system monitoring shall provide


Y. Monitorizarea sistemului trebuie să ofere o
an End-to-End critical service view
imagine de serviciu critică End-to-End, care
which shall be consolidating at least
să consolideze cel puțin următoarele
following information:
informații:
• Starea serviciului ATS de la ambele capete  ATS service status on both ends
până la nivelul logic al unui serviciu ATS down to the logical leg of an
individual, cum ar fi starea frecvenței VHF; individual ATS service, such as a
VHF frequency status;

05/05/2021 55
• Starea de serviciu a tuturor elementelor din  Service status of all elements in
lanțul de comunicare; the communication chain;

 Connection status between the


• Starea conexiunii între servicii;
services;

• Ce rețea este utilizată de serviciul special  Which network is used by the


ATS. particular ATS service.

2.2.9.2 Scalability & Expansion Capability/ Scalabilitate și capacitate de extindere

A. Sistemul LAN va fi configurabil în funcție The LAN system shall be configurable


de presupunerea creșterii viitoare a depending on assuming the future
Aeroportului Brașov. Sistemul va avea growth of Brasov Airport. The system
capacitatea de a-și asuma această creștere a will have capacity to assume this
numărului de dispozitive gestionate fără a increase in the number of managed
necesita actualizarea sistemului sau investiții devices without requiring any system
noi. upgrade or new investment.
B. Scalabilitate: Pentru extinderea viitoare va
Scalability: For future expansion it shall
fi posibilă includerea unor Switch-uri
be possible to include additional
suplimentare. Mediul LAN va putea suporta
switches. The LAN environment will be
cel puțin până la 15% switch-uri in plus și va
able to support at least up to 15%
putea susține o creștere viitoare în următorii
switches more and will be able to
ani de funcționare. Resursele sistemului
support a future growth in the next
(core/switches capacities, memory, and
years of operation. System resources
network bandwidth) vor fi dimensionate
(core/switches capacities, memory,
corespunzător.
and network bandwidth) will be
dimensioned accordingly.

C. Furnizorul va furniza capacități de The Supplier shall provide expansion


extindere și de rezervă pentru orice and reserve capacities for any
echipament, dacă este necesar. equipment, if required.

Power supplies shall have a capacity of


D. Sursele de alimentare trebuie să aibă o 1.5 times that required for the
capacitate de 1,5 ori mai mare decât cea proposed design.
necesară pentru proiectarea propusă.

05/05/2021 56
E. Trebuie furnizate fizic suficiente porturi de Sufficient input/output
comunicații de intrare / ieșire pentru a communications ports shall be
îndeplini cerințele specificate, plus o physically provided to meet the
capacitate de rezervă de 20%. specified requirements plus 20% spare
capability.

2.2.9.3 Redundancy/Reduntanta

A. Switch-urile LAN Core / de agregare vor fi LAN Core/aggregation switches shall


instalate în centrul de date de pe aeroport. be installed in the Data Centre at the
Airport.
B. Sistemul software de management care
The management software system to
urmează să fie implementat în cele din urmă
be finally deployed in the Data Centre
în Data Centre trebuie să utilizeze tehnologia
should use the virtual server
serverului virtual.
technology.

C. Optimizarea resurselor ar trebui menținută Optimization of resources should be


și trebuie respectate capacitățile fizice și de maintained and the environmental
mediu ale Data Centrului. Fiabilitatea și costul and physical capabilities of the Data
vor fi caracteristici cheie ale deciziei, Centre respected. Reliability and cost
împreună cu capacitatea de a utiliza energia shall be key decision features together
eficient în vederea menținerii costurilor de with the ability to use power efficiently
operare la un nivel minim. with a view to keeping operating costs
to a minimum.
D. Sistemul se instaleaza în așa fel încât să The System shall be deployed in such
asigure o trecere la o hot failover, asigurând a way as to provide a redundant, hot
o solutie no single point of failure. failover ensuring no single point of
failure solution.
E. Sistemul trebuie să fie tolerant la
The System shall be fault-tolerant, with
defecțiuni, cu o capacitate de rezervă sau
back-up or redundant capacity built-in
redundantă încorporată și trebuie să aibă
and should have the following service
următoarele considerații privind continuitatea
continuity considerations
serviciului

05/05/2021 57
• Disponibilitate ridicată: este necesar un  High Availability: A high-level of
nivel ridicat de disponibilitate a sistemului. system availability is required.
Sistemul trebuie să fie proiectat pentru a
The System shall be designed to
îndeplini cerințele de disponibilitate. Acest
lucru poate fi îndeplinit prin fiabilitate ridicată meet the availability
disponibilă în fiecare componentă, prin requirements. This may be met
servere redundante sau o combinație a celor
through high reliability available
două.
in each component, through
redundant servers, or a
combination of the two.

• Hot Swappable: Sistemul trebuie să fie  Hot Swappable: System shall be


proiectat pentru a permite înlocuirea designed to allow for the
componentelor defecte sau defecte în timp
replacement of failed or failing
ce sistemul funcționează, până la înlocuirea
components while the system is
cardurilor, componentelor și a altor module
discrete ale sistemului. operating, up to and including
replacement of cards,
components, and other discrete
modules of the system.
• Conexiunea între site-uri (Brașov și  The connection between sites
facilitatea RVT) va fi asigurată in cadrul altui
(Brasov and the RVT facility) shall
contract, dar furnizorul rețelei va considera că
vor fi implementate trei legături între site-uri be provide by others, but the
și, prin urmare, toate informațiile vor fi trimise Network supplier shall consider
prin aceste trei linkuri.
that three links between sites
shall be implemented and
therefore all information shall be
sent it through these three links.

Bogdan- Digitally signed by


Bogdan-Constantin
Constantin Ciubotaru
Date: 2021.06.18
Ciubotaru 10:50:11 +03'00'

05/05/2021 58