Documente Academic
Documente Profesional
Documente Cultură
Proiect EIT
Proiect EIT
- Facultatea de Energetic -
tax
2
tax
1
d2/d2
A
d3/d4
ta``
ta`
tg`
Sectiunea A-A
drumul
drumul
Gaze de
ardere
INTRODUCERE:
TEMA PROIECTULUI:
Sa se proiecteze un recuperator de caldura tip clepsidra unde se cunosc datele de intrare.
n=
ngrupa =
17
6
DATE DE INTRARE:
DaN
340+9n
493
b)
DgN
300+10n
470
c)
t'a
15+(ngrupa/2)
18
d)
t''a
200-(ngrupa/2)+2n
231
e)
t'g
900-2n
866
f)
rCO2
4+(n/5)
7.4
rO2
8-n/10
6.3
rH2O
13-n/10
11.3
rCO
n/20
0.85
rN2
75-n/20
74.15
hr
0.97
0.97
15
15
a)
g)
h)
i)
wa1
wa2
10
10
0.8
0.8
j)
N
wg
k)
de
0.04
0.04
l)
dp
0.5
0.5
m)
lp
40
40
n)
de-2dp
o)
0.005
0.039
0.005
di
d
Nm3/h
Nm3/h
o
%
%
%
%
%
m/s
m/s
m/s
m
mm
W/m*K
m
m
ETAPA 1
PROPRIETATILE TERMOFIZICE SI TERMODINAMICE ALE AERULUI SI ALE GAZELOR DE ARDERE
PROPRIETATI AER:
Temperatura
o
cam
la
ha106
ra
ia
na104
aa
Prax104
kJ/(Nm3*K)
W/(m*K)
Pa*s
Kg/m3
kJ/Nm3
m2/s
m2/s
[-]
t'a
18
1.29754
0.025856
18.046
t''a
231
1.3101
0.0414435
27.147
ta
124.5
1.301715
0.03392175
22.9045
0.888038023
517.62697
0.25792251 0.03793692
6.79871964
tax,I
124.5
1.301715
0.03392175
22.9045
0.888038023
517.62697
0.25792251 0.03793692
6.79871964
tax,II
166
1.30462
0.036889
24.606
ta1,I
71.25
1.2991375
0.02995625
20.54875
ta1,II
92
1.29976
0.031554
21.524
ta2,I
177.75
1.3054425
0.037729125
25.08775
ta2,II
198.5
1.306895
0.03921275
25.9385
0.0290733
6.893213624
0.96707742
0.03245349
6.85804588
474.607364
0.2225675
0.051809
6.686932049
124.5
In calculul ulterior este necesara determinarea temperaturii aerului la iesirea din prima treapta de preincalzire. Se initializeaza cu 2 valori
arbitrare aceasta temperatura :
CAZUL I (pentru prima valoare arbitrara) :
Temperatura aerului la iesirea din prima treapta de preincalzire :
tax,I
=
(t'a+t''a)/2
=
124.5
Temperatura medie a aerului pe primul drum :
ta1,I
=
(t'a+tax,I)/2
=
71.25
Temperatura medie a aerului pe al 2-lea drum :
ta2,I
(tax,I+t''a)/2
177.75
cam
C
0
100
200
300
kJ/(Nm3*K)
1.297
1.3
1.307
1.317
cam
C
0
18
100
kJ/(Nm3*K)
1.297
cam
1.3
cam
C
200
231
kJ/(Nm3*K)
1.307
cam
18
231
300
1.317
cam
C
100
124.5
200
kJ/(Nm3*K)
1.3
cam
1.307
cam
C
100
124.5
200
kJ/(Nm3*K)
1.3
cam
1.307
cam
C
100
166
200
kJ/(Nm3*K)
1.3
cam
1.307
cam
C
0
kJ/(Nm3*K)
1.297
124.5
124.5
166
71.25
71.25
100
cam
1.3
cam
C
0
92
100
kJ/(Nm3*K)
1.297
cam
1.3
cam
C
100
177.75
200
kJ/(Nm3*K)
1.3
cam
1.307
cam
C
100
198.5
200
kJ/(Nm3*K)
1.3
cam
1.307
la
C
0
0.02447
W/(m*K)
92
177.75
198.5
100
200
300
0.03217
0.03932
0.04617
la
C
0
18
100
W/(m*K)
la
C
200
231
300
0.03932
la
0.04617
la
C
100
124.5
200
0.03217
la
0.03932
231
124.5
124.5
W/(m*K)
W/(m*K)
18
0.02447
la
0.03217
la
C
100
124.5
200
W/(m*K)
0.03217
la
0.03932
la
C
100
166
200
W/(m*K)
la
C
0
71.25
100
0.02447
la
0.03217
71.25
92
177.75
W/(m*K)
la
C
0
92
100
0.02447
la
0.03217
166
0.03217
la
0.03932
W/(m*K)
la
C
100
177.75
200
W/(m*K)
0.03217
la
0.03932
la
C
100
198.5
200
0.03217
la
0.03932
198.5
18
W/(m*K)
.
ha106
C
0
100
200
300
17.2
21.9
26
29.7
Pa*s
ha106
C
0
Pa*s
17.2
18
100
ha106
21.9
ha106
C
200
Pa*s
231
300
ha106
29.7
ha106
C
100
Pa*s
21.9
124.5
200
ha106
26
ha106
C
100
Pa*s
21.9
124.5
200
ha106
26
ha106
C
100
21.9
166
ha106
231
124.5
124.5
166
26
Pa*s
200
26
ha106
C
0
Pa*s
17.2
71.25
100
ha106
21.9
ha106
C
0
17.2
92
100
ha106
21.9
ha106
C
100
21.9
177.75
200
ha106
26
92
177.75
198.5
Pa*s
ha106
Pa*s
71.25
Pa*s
100
21.9
198.5
200
ha106
26
raN
K
273.15
Kg/Nm3
1.2928
1.212874189
0.700442963
0.888038023
0.888038023
0.804117773
1.025343554
0.96707742
0.783163273
Kg/m
Kg/m
Kg/m
Kg/m
Kg/m
Kg/m
Kg/m
Kg/m
18
231
124.5
124.5
166
71.25
92
177.75
198.5
ra
raN*T0/( ta2,II+273,15)
0.748708407
Kg/m3
377.778771
660.486915
517.6269698
517.6269698
572.923873
447.422955
474.607364
588.6240233
616.3970268
kJ/Nm
kJ/Nm
kJ/Nm
kJ/Nm
kJ/Nm
kJ/Nm
kJ/Nm
kJ/Nm
kJ/Nm
18
231
124.5
124.5
166
71.25
92
177.75
198.5
18
na104
-2
0.148787073
m /s
231
124.5
124.5
166
71.25
92
177.75
198.5
18
231
m /s
m /s
m /s
m /s
m /s
m /s
m /s
m /s
m /s
m /s
124.5
124.5
166
71.25
92
177.75
198.5
18
231
124.5
124.5
m /s
m /s
m /s
m /s
m /s
m2/s
m2/s
7.005014288
6.638019451
6.79871964
6.79871964
[-]
[-]
[-]
[-]
166
71.25
92
177.75
198.5
ig
[-]
[-]
[-]
[-]
[-]
t'g
lg
hg106
rg
kJ/(Nm *K)
W/(m*K)
Pa*s
Kg/m
1.47765773
0.076338494
44.93002349
0.303286887
1683.2738
1.4814364
t'g
866
cgm
3
C
866
kJ/Nm
ng104
3
m /s
ag
Prgx104
[-]
m /s
0.21545146 6.875963541
cgm
C
600
kJ/(Nm3*K)
1.345
700
800
900
1000
1.359
1.372
1.385
1.397
cgm
cgm
C
800
866
900
kJ/(Nm3*K)
1.372
cgm
1.385
N2
O2
C
600
kJ/(Nm3*K)
1.417
700
800
900
1000
1.434
1.45
1.465
1.478
cgm
C
600
kJ/(Nm3*K)
1.357
700
800
900
1000
1.372
1.386
1.4
1.413
cgm
C
600
kJ/(Nm3*K)
2.041
700
800
900
1000
2.088
2.131
2.169
2.204
cgm
C
600
kJ/(Nm3*K)
1.61
700
800
900
1000
1.64
1.67
1.695
1.72
cgm
C
800
866
900
kJ/(Nm3*K)
1.45
cgm
1.465
O2
cgm
C
800
866
900
kJ/(Nm3*K)
1.386
cgm
1.4
CO
cgm
C
800
866
900
kJ/(Nm3*K)
2.131
cgm
2.169
CO2
cgm
C
800
866
900
kJ/(Nm3*K)
1.67
cgm
1.695
H2O
cgm
(cgmi*ri)
1.47765773
kJ/(Nm *K)
t'g
866
lg
C
600
W/(m*K)
0.0604
700
800
900
1000
0.0642
0.0675
0.0701
0.0723
lg
C
600
W/(m*K)
0.0674
700
800
900
1000
0.0728
0.0777
0.082
0.0858
lg
C
600
W/(m*K)
0.0597
700
800
900
1000
0.065
0.0701
0.0755
0.0806
lg
t
o
C
800
866
900
lg
W/(m*K)
N2
0.0675
lg
0.0701
t
o
C
800
866
900
lg
W/(m*K)
O2
0.0777
lg
0.082
t
o
C
800
866
900
lg
W/(m*K)
CO
0.0701
lg
0.0755
CO2
t
o
C
800
866
900
lg
CO2
W/(m*K)
0.0751
lg
0.0809
C
600
0.0621
700
800
900
1000
0.0688
0.0751
0.0809
0.0866
lg
C
600
W/(m*K)
0.0818
700
800
900
1000
0.0956
0.11
0.124
0.141
t
o
lg
lg
C
800
866
900
W/(m*K)
(gi*ri)
H2O
0.11
lg
0.124
0.076338494
W/(m*K)
t'g
866
hg106
C
600
Pa*s
36.9
Pa*s
o
t
o
C
800
866
900
Viscozitatea dinamica pentru O2:
hg106 =
52.312
hg10
N2
42.3
hg106
45
700
800
39.6
42.3
900
1000
45
47.5
Pa*s
hg106
C
600
Pa*s
Pa*s
W/(m*K)
hg10
O2
43.5
C
800
866
900
Viscozitatea dinamica pentru CO:
hg106 =
45.048
O2
50.2
hg106
53.4
700
800
47
50.2
900
1000
53.4
56.5
Pa*s
hg106
C
600
Pa*s
37.4
700
800
40.4
43.2
900
1000
46
48.7
hg106
C
600
Pa*s
37.7
700
800
41.1
44.6
900
1000
48.1
51.5
hg106
C
600
Pa*s
33.1
700
800
37.9
42.6
900
1000
47.5
52.4
Pa*s
t
o
C
800
866
900
hg106
CO
Pa*s
43.2
hg106
46
t
o
C
800
866
900
hg10
CO2
Pa*s
44.6
hg106
48.1
t
o
C
800
866
900
hg10
Pa*s
42.6
hg106
47.5
H2O
hg106
1/(ri/gi)
44.93002349
Pa*s
t'g
1.26483345
Kg/Nm3
866
t'g
866
t'g
866
t'g
866
t'g
866
t(0C) = 0
N2
O2
CO
CO2
H2O
rg
1.2505
1.4289
1.25
1.9748
0.8036
T0
273.15
Tg
1139.15
rg
rgN*(T0/Tg)
0.303286887
Kg/m3
cgm*(t'g+273,15)
1683.273803
(hg*106)*10-2/rg
1.481436405
[lg/(rg*cgm)]*rgN
0.215451463
(ng*104)/ag
6.875963541
m2/s
m2/s
kJ/Nm3
[-]
ETAPA 2
DETERMINAREA TEMPERATURII GAZELOR DE ARDERE LA IESIREA DIN RECUPERATOR SI
A PROPRIETATIILOR SALE, CAT SI A TEMPERATURII MEDII
Din ecuatia bilantului termic pe recuperator se v-a determina entalpia gazelor de ardere la iesire:
Qa = r*Qg <=> (DaN/3600)*(i''a- i'a) = r*(DgN/3600)*(i'g- i''g) =>
cgm
C
600
kJ/(Nm3*K)
1.345
700
800
900
1000
1.359
1.372
1.385
1.397
cgm
C
600
kJ/(Nm3*K)
1.417
700
800
900
1000
1.434
1.45
1.465
1.478
cgm
cgm
kJ/(Nm3*K)
C
900
1.385
cgm
932.2589058
1000
1.397
o
N2
cgm
kJ/(Nm3*K)
C
900
1.465
cgm
932.2589058
1000
1.478
o
O2
CO
C
600
kJ/(Nm3*K)
1.357
700
800
900
1000
1.372
1.386
1.4
1.413
cgm
C
600
kJ/(Nm3*K)
2.041
700
800
900
1000
2.088
2.131
2.169
2.204
cgm
C
600
kJ/(Nm3*K)
1.61
700
800
900
1000
1.64
1.67
1.695
1.72
cgm
CO
kJ/(Nm3*K)
C
900
1.4
cgm
932.2589058
1000
1.413
o
cgm
CO2
kJ/(Nm3*K)
C
900
2.169
cgm
932.2589058
1000
2.204
o
cgm
H2O
kJ/(Nm3*K)
C
900
1.695
cgm
932.2589058
1000
1.72
o
c''gm*
(cgmi*ri)
1.488130564
kJ/(Nm3*K)
c''gm**t''g
1387.322971
kJ/Nm3
0.007087456
|(i''g-i''g*)/ i''g|
<
OBS:
In cazul in care eroarea admisibila relativa a entalpiei era mai mare decat 1%, am fi aplicat un calcul iterativ pana ce aceasta devenea
mai mica decat 1%
=>
t''g
932.2589058
Se vor calcula proprietatiile gazelor de ardere pentru temperatura la iesirea din recuperator si temperatura medie:
cgm
lg
hg106
rg
ig
ng104
Temperatura
o
ag
Prgx104
kJ/(Nm3*K)
W/(m*K)
Pa*s
Kg/m3
kJ/Nm3
m2/s
m2/s
[-]
t''g
932.2589058
1.488130564
0.079158713
46.87441577
0.286615816
1387.323
1.635444145
0.234742
6.966984365
tg
899.1294529
1.483071248
0.07774845
45.93016674
0.294715783
1738.574
1.558456295
0.224988
6.926836762
t''g
932.2589058
lg
C
600
0.0604
700
800
900
1000
0.0642
0.0675
0.0701
0.0723
lg
C
600
0.0674
700
800
900
1000
0.0728
0.0777
0.082
0.0858
lg
lg
C
900
932.2589058
1000
W/(m*K)
N2
0.0701
lg
0.0723
lg
C
900
932.2589058
1000
W/(m*K)
O2
0.082
lg
0.0858
CO
W/(m*K)
W/(m*K)
t
o
C
900
932.2589058
1000
lg
CO
W/(m*K)
0.0755
lg
0.0806
C
600
0.0597
700
800
900
1000
0.065
0.0701
0.0755
0.0806
lg
C
600
W/(m*K)
0.0621
700
800
900
1000
0.0688
0.0751
0.0809
0.0866
lg
C
600
W/(m*K)
0.0818
700
800
900
1000
0.0956
0.11
0.124
0.141
t
o
C
900
932.2589058
1000
lg
CO2
W/(m*K)
0.0809
lg
0.0866
t
o
lg
lg
C
900
932.2589058
1000
W/(m*K)
(gi*ri)
H2O
0.124
lg
0.141
0.079158713
W/(m*K)
t''g
932.2589058
hg106
Pa*s
600
36.9
hg10
W/(m*K)
N2
C
900
932.2589058
1000
N2
Pa*s
45
hg106
47.5
700
800
39.6
42.3
900
1000
45
47.5
hg106
C
600
Pa*s
43.5
700
800
47
50.2
900
1000
53.4
56.5
hg106
C
600
Pa*s
37.4
700
800
40.4
43.2
900
1000
46
48.7
hg106
C
600
Pa*s
37.7
700
800
41.1
44.6
900
1000
48.1
51.5
hg106
t
o
C
900
932.2589058
1000
hg106
O2
Pa*s
53.4
hg106
56.5
t
o
C
900
932.2589058
1000
hg10
CO
Pa*s
46
hg106
48.7
t
o
C
900
932.2589058
1000
hg10
Pa*s
CO2
48.1
hg106
51.5
H2O
hg10
t
o
C
900
hg106
H2O
Pa*s
932.2589058
1000
47.5
hg106
52.4
1/(ri/gi)
46.87441577
t''g
1.26483345
Kg/Nm3
932.2589058
t''g
932.2589058
t''g
932.2589058
t''g
932.2589058
t(0C) = 0
N2
O2
CO
CO2
H2O
rg
1.2505
1.4289
1.25
1.9748
0.8036
T0
273.15
Tg
1205.408906
rg
rgN*(T0/Tg)
0.286615816
Kg/m3
(hg*106)*10-2/rg
1.635444145
[lg/(rg*cgm)]*rgN
0.234742043
(ng*10 )/ag
6.966984365
37.9
42.6
900
1000
47.5
52.4
m2/s
700
800
m2/s
33.1
Pa*s
C
600
[-]
Pa*s
tg
(t'g+t''g)/2
899.129453
C
tg
899.1294529
cgm
C
600
kJ/(Nm3*K)
1.345
700
800
900
1000
1.359
1.372
1.385
1.397
cgm
C
600
kJ/(Nm3*K)
1.417
700
800
900
1000
1.434
1.45
1.465
1.478
cgm
C
600
kJ/(Nm3*K)
1.357
700
800
900
1000
1.372
1.386
1.4
1.413
cgm
kJ/(Nm3*K)
cgm
kJ/(Nm3*K)
C
800
1.372
cgm
899.1294529
900
1.385
o
N2
cgm
kJ/(Nm3*K)
C
800
1.45
cgm
899.1294529
900
1.465
o
O2
cgm
kJ/(Nm3*K)
C
800
1.386
cgm
899.1294529
900
1.4
o
CO
CO2
cgm
CO2
kJ/(Nm *K)
C
800
2.131
cgm
899.1294529
900
2.169
600
2.041
700
800
900
1000
2.088
2.131
2.169
2.204
cgm
C
600
kJ/(Nm3*K)
1.61
700
800
900
1000
1.64
1.67
1.695
1.72
cgm
H2O
kJ/(Nm3*K)
C
800
1.67
cgm
899.1294529
900
1.695
o
cgm
(cgmi*ri)
1.483071248
kJ/(Nm *K)
tg
899.1294529
lg
C
600
W/(m*K)
0.0604
700
800
900
1000
0.0642
0.0675
0.0701
0.0723
lg
C
600
0.0674
700
800
0.0728
0.0777
t
o
C
800
899.1294529
900
lg
W/(m*K)
N2
0.0675
lg
0.0701
lg
C
800
W/(m*K)
0.0777
O2
W/(m*K)
O2
899.1294529
900
lg
0.082
900
1000
0.082
0.0858
lg
C
600
W/(m*K)
0.0597
700
800
900
1000
0.065
0.0701
0.0755
0.0806
lg
C
600
W/(m*K)
0.0621
700
800
900
1000
0.0688
0.0751
0.0809
0.0866
lg
C
600
W/(m*K)
0.0818
700
800
900
1000
0.0956
0.11
0.124
0.141
t
o
C
800
899.1294529
900
lg
CO
W/(m*K)
0.0701
lg
0.0755
t
o
C
800
899.1294529
900
lg
CO2
W/(m*K)
0.0751
lg
0.0809
t
o
lg
lg
C
800
899.1294529
900
W/(m*K)
(gi*ri)
H2O
0.11
lg
0.124
0.07774845
W/(m*K)
tg
899.1294529
hg106
C
600
Pa*s
36.9
700
800
39.6
42.3
900
1000
45
47.5
hg106
C
600
Pa*s
43.5
700
800
47
50.2
900
1000
53.4
56.5
hg106
C
600
Pa*s
37.4
700
800
40.4
43.2
900
1000
46
48.7
hg106
C
600
Pa*s
37.7
700
800
41.1
44.6
t
o
C
800
899.1294529
900
hg10
N2
Pa*s
42.3
hg106
45
t
o
C
800
899.1294529
900
hg10
O2
Pa*s
50.2
hg106
53.4
hg10
C
800
Pa*s
899.1294529
900
CO
43.2
hg106
46
hg10
C
800
Pa*s
44.6
CO2
CO2
899.1294529
900
hg106
48.1
900
1000
48.1
51.5
hg106
C
600
Pa*s
33.1
700
800
37.9
42.6
900
1000
47.5
52.4
t
o
C
800
hg106
hg10
H2O
Pa*s
899.1294529
900
42.6
hg106
47.5
1/(ri/gi)
45.93016674
Pa*s
tg
1.26483345
Kg/Nm
899.1294529
tg
899.1294529
tg
899.1294529
N2
O2
CO
CO2
H2O
rg
1.2505
1.4289
1.25
1.9748
0.8036
T0
273.15
Tg
1172.279453
rg
rgN*(T0/Tg)
0.294715783
Kg/m3
cgm*(tg+273,15)
1738.573952
t(0C) = 0
N
kJ/Nm3
ng104
-2
1.558456295
m /s
[lg/(rg*cgm)]rgN
0.224988165
(ng*104)/ag
6.926836762
899.1294529
tg
899.1294529
m /s
tg
[-]
ETAPA 3
DETERMINAREA NUMARULUI DE TEVI SI A DIAMETRELOR SECTIUNII
TRANSVERSALE A RECUPERATORULUI
d4
d3
d2
d1
nt
buc
W a1,I
m/s
18.06746716
W a1,II
m/s
19.15602681
d1
0.47
d2
0.48
Wg
m/s
3.428177843
d3
0.5
d4
0.51
W a2,I
m/s
14.68511988
W a2,II
m/s
15.36091549
Prin rotunjirea numarului de tevi creste sectiunea de curgere a aerului si scade viteza
wa1N
4*DaN/(3600**di2*nt)
=>
8
Prin urmare vom recalcula wa1N :
7.642475656
w a1N.
14.32964186
m/s
18.06746716
m/s
wa1N*(Ta1,I/To)
tevi
buc
wa1,II
wa1N*(Ta1,II/To)
19.15602681
m/s
0.469665434
0.48
0.47
0.5
d1+2
4*DgN/[3600**(d12-nt*de2)]
w gN.
0.798791428
m/s
3.428177843
m/s
wgN*(Tg/To)
X Determinarea diametrelor virolei exterioare si vitezele aerului in conditii normale pe al 2-lea drum:
Diametrul d3 se determina din ecuatia de continuitate pentru aer in canalul inelar:
DaN/3600 = wa2N*(/4)*(d32-d22) => d3 = [d22+4*DaN/(3600**wa2N)]
0.497831606
0.51
d3+2
4*DaN/[3600**(d32-d22)]
w a2N.
=
m/s
14.68511988
m/s
15.36091549
m/s
Viteza aerului in conditii normale prin tevi, pe cel de-al 2-lea drum:
wa2,I
wa2,II
=
=
wa2N*(Ta2,I/To)
N
wa2 *(Ta2,II/To)
ETAPA 4
CALCULUL COEFICIENTILOR DE CONVECTIE PENTRU AER SI GAZE DE ARDERE
evi
Canalul inelar
tg, g1
tg, g2
tp1
tp2
ta1, a1
ta, a2
di
d1
de
d2
daech,1
0.039
daech,2
0.02
Rea1,I
35159.75807
Rea2,I
9168.495826
Rea1,II
W/(m2*K)
33566.67342
Rea2,II
4.832139886
a2,I
W/(m2*K)
8867.780757
a1,I
a1,II
W/(m2*K)
a2,II
W/(m2*K)
2.501152067
4.894494813
2.473949787
0.263
dgech
0.263
Reg
5785.281085
Reg
0.254108399
cg
W/(m2*K)
5785.281085
cg
W/(m2*K)
rg1,I
W/(m2*K)
33.47143304
rg2,I
W/(m2*K)
25.54718446
rg1,II
W/(m *K)
34.371521
rg2,II
W/(m *K)
24.4896992
g1,I
W/(m2*K)
33.72554144
g2,I
W/(m2*K)
25.80129286
g1,II
W/(m2*K)
34.6256294
g2,II
W/(m2*K)
tp1,I
tp1,II
485.1897265
tp2,I
495.5647265
tp2,II
di
0.039
d3-d2
0.02
wa1,I*daech1/a1,I
35159.75807
0.254108399
24.7438076
538.4397265
548.8147265
AER:
Diametrul echivalent:
X Pentru tevi:
daech,1
Numarul Reynolds:
X Pentru tevi:
Rea1,I
Rea1,II
wa1,II*d
ech1/a1,II
33566.67342
Rea2,I
wa2,I*daech2/a2,I
9168.495826
Rea2,II
wa2,II*daech2/a2,II
8867.780757
=>
=>
a1,I
a1,II
0,8
0,4
ech1)*Rea1,I *Pra1,I
0,0267*(a1,II/daech1)*Rea1,II0,8*Pra1,II0,4
Coeficientul de convectie:
X Pentru tevi:
4
Rea1,I>10
Rea1,II>10
0,0267*(a1,I/d
4.832139886
4.894494813
=>
2320< Rea2,I<10
=>
2320< Rea2,II<10
a2,I
a2,II
0,43
ech2)*k*Pra2,I
-0,192*10-6*Rea2,I2+6,04*10-3*Rea2,I-8,89
a
0,43
(a2,II/d ech2)*k*Pra2,II
-0,192*10-6*Rea2,II2+6,04*10-3*Rea2,II-8,89
(a2,I/d
2.473949787
30.34794217
2.501152067
29.57298895
GAZE DE ARDERE:
Transferul de caldura pe partea gazelor se realizeaza prin convectie si radiatie (g = cg+rg):
Convectie:
X Diametrul echivalent:
dgech
4*S/P
[4*(/4)*(d12-nt*de2)]/[*(d1+nt*de)]
(d12-nt*de2)/(d1+nt*de)
0.263417722
0.263
wg*dgech/g
5785.281085
=>
cg
(g/dgech)*k*Prg0,43
0.254108399
-0,192*10-6*Reg2+6,04*10-3*Reg-8,89
19.62695813
tp=(ta+tg)/2
=>
(ta1,I+tg)/2
485.1897265
qrg1+qrg2
X Numarul Reynolds:
Reg
X Coeficientul de convectie:
2320< Reg<104
Radiatie:
Presupunem initial ca:
TEVI:
tp1,I
qrg
qrg
f(tg, pCO2*l)
f(tg, pH2O*l)
1,15*qrg1
=
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp/100)4]
=
=
=
=>
c0
0.79
=
=
CO2+*H2O
0.062
5.67
0.11276
din grafic
pCO2
(rCO2/100)*patm
=
=
0.074
7.4
din grafic
pH2O
=
=
=
0.047
(rH2O/100)*patm
0.113
11.3
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura gazelor de ardere:
pCO2*l
pH2O*l
Coeficientul de corectie:
patm
l
=
=
0,9*dgech
=
=
1
0.2367
=
kPa*m
899.1294529
tg
1.75158
2.67471
kPa*m
0.0267471
m*bar
f(pH2O, pH2O*l)
f(tp, pCO2*l)
=
Presiunea partiala pentru CO2:
f(tp, pH2O*l)
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
pCO2*l
=
pH2O*l
=
Coeficientul de corectie:
=
r
qg
=
rg
g
din grafic
1.08
Agp
=
pCO2
din grafic
=
=
=
CO2p*(Tg/Tp)0,65+*H2Op
0.155236108
0.06
=
pH2O
din grafic
=
=
=
tp
Tp
Tg
1.75158
=
=
=
kPa*m
=
=
=
485.1897265
758.3397265
1172.279453
2.67471
kPa*m
0.0267471
m*bar
f(pH2O, pH2O*l)
1.08
9431.425794
22.78453889
23.03864728
din grafic
4
1,15*c0*[(1+p)/2]*[g*(Tg/100) -Agp*(Tp/100) ]
r
q g/(tg-tp)
c
g+ g
=
=
0.07
(rH2O/100)*patm
0.113
11.3
1
0.2367
=
=
Se reiau calculele:
- Agentul termic al peretelui
=
=
=
0,9*dgech
patm
l
g/(tg-tp*)=a/(tp*-ta)
|tp-tp*|
(rCO2/100)*patm
0.074
7.4
270.404874
(ta*a+tg*g)/(a+g)
(ta1,I*a1,I+tg*g)/(a1,I+g)
=
>
755.5946004
1
=
C
=>
Agp
=
=
CO2p*(Tg/Tp*)0,65+*H2Op
0.124733511
CO2
f(tp , pCO2*l)
f(tp*, pH2O*l)
Presiunea atmosferica:
Grosimea medie a stratului radiat:
patm
l
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
pCO2*l
=
pH2O*l
=
Coeficientul de corectie:
=
r
qg
=
rg
din grafic
pCO2
=
=
=
=
pH2O
din grafic
=
=
2.67471
kPa*m
0.0267471
m*bar
f(pH2O, pH2O*l)
din grafic
1.08
-Agp*(Tp*/100)4]
4274.497098
29.78020337
30.03431177
1,15*c0*[(1+p)/2]*[g*(Tg/100)
c
g+ g
28.79907826
f(tp**, pCO2*l)
f(tp**, pH2O*l)
Presiunea atmosferica:
qrg/(tg-tp*)
=
=
755.5946004
1028.7446
1172.279453
Se reiau calculele:
- Agentul termic al peretelui
=
0.053
(rH2O/100)*patm
0.113
11.3
1
0.2367
=
=
=
CO2p
=
=
=
0,9*dgech
-
(rCO2/100)*patm
0.074
7.4
=
=
=
kPa*m
|tp*-tp**|
0.062
tp
Tp*
Tg
1.75158
patm
(ta*a+tg*g)/(a+g)
(ta1,I*a1,I+tg*g)/(a1,I+g)
=
C
=>
=
>
784.3936787
1
Agp
=
pCO2
din grafic
din grafic
pH2O
=
=
=
-
=
=
=
=
=
=
CO2p*(Tg/Tp**)0,65+*H2Op
0.117085327
0.059
(rCO2/100)*patm
0.074
7.4
0.05
(rH2O/100)*patm
0.113
11.3
1
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
pCO2*l
=
pH2O*l
=
Coeficientul de corectie:
=
qrg
=
rg
**
=
=
=
784.3936787
1057.543679
1172.279453
2.67471
kPa*m
0.0267471
m*bar
f(pH2O, pH2O*l)
din grafic
1.08
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp**/100)4]
3880.771825
qrg/(tg-tp**)
33.82355548
34.07766388
g+ g
11.92288549
Se reiau calculele:
- Agentul termic al peretelui
CO2p
f(tp***, pCO2*l)
f(tp***, pH2O*l)
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
pCO2*l
=
pH2O*l
=
Coeficientul de corectie:
=
r
qg
=
0.2367
g/(tg-tp***)=a/(tp***-ta)
=
=
=
kPa*m
|tp**-tp***|
0,9*d
tp
**
Tp
Tg
1.75158
g
ech
patm
l
(ta*a+tg*g)/(a+g)
=
=
>
796.3165642
1
C
=>
Agp
=
pCO2
din grafic
=
=
=
=
pH2O
din grafic
=
0
=
=
=
=
=
***
(ta1,I*a1,I+tg*g)/(a1,I+g)
CO2p*(Tg/Tp***)0,65+*H2Op
0.117707283
0.059
(rCO2/100)*patm
0.074
7.4
0.051
=
=
=
0,9*dgech
=
=
(rH2O/100)*patm
0.113
11.3
1
0.2367
tp
***
Tp
Tg
1.75158
=
=
=
kPa*m
=
=
=
796.3165642
1069.466564
1172.279453
2.67471
kPa*m
0.0267471
m*bar
f(pH2O, pH2O*l)
din grafic
1.08
-Agp*(Tp***/100)4]
3441.294722
1,15*c0*[(1+p)/2]*[g*(Tg/100)
***
q g/(tg-tp )
c
g+ g
g/(tg-tp****)=a/(tp****-ta)
=
=
(ta*a+tg*g)/(a+g)
(ta1,I*a1,I+tg*g)/(a1,I+g)
|tp***-tp****|
0.9389238
<
795.3776404
1
tp1,II
(ta1,II+tg)/2
495.5647265
qrg1+qrg2
qrg
qrg
1,15*qrg1
=
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp/100)4]
=
=
=
33.47143304
33.72554144
=
=
C
=>
c0
0.79
=
=
CO2+*H2O
5.67
0.11276
CO2
f(tg, pCO2*l)
=
Presiunea partiala pentru CO2:
din grafic
pCO2
=
=
=
din grafic
pH2O
0.062
(rCO2/100)*patm
0.074
7.4
H2O
f(tg, pH2O*l)
=
Presiunea partiala pentru H2O:
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura gazelor de ardere:
pCO2*l
pH2O*l
Coeficientul de corectie:
0.047
=
=
=
g
0,9*d ech
=
=
(rH2O/100)*patm
0.113
11.3
1
0.2367
patm
l
=
=
tg
1.75158
=
kPa*m
899.1294529
=
=
2.67471
kPa*m
0.0267471
m*bar
f(pH2O, pH2O*l)
din grafic
=
Presiunea partiala pentru CO2:
f(tp, pCO2*l)
Agp
din grafic
pCO2
=
=
=
=
=
=
1.08
p
CO2 *(Tg/Tp)0,65+*H2Op
0.15848261
0.063
(rCO2/100)*patm
0.074
7.4
f(tp, pH2O*l)
=
pH2O
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
pCO2*l
=
pH2O*l
=
Coeficientul de corectie:
=
r
qg
=
rg
=
=
=
kPa*m
=
=
=
495.5647265
768.7147265
1172.279453
2.67471
kPa*m
0.0267471
m*bar
f(pH2O, pH2O*l)
1.08
1,15*c0*[(1+p)/2]*[g*(Tg/100) -Agp*(Tp/100) ]
9197.913196
qrg/(tg-tp)
22.79166784
23.04577623
din grafic
4
262.1741539
Se reiau calculele:
- Agentul termic al peretelui
=
f(tp*, pCO2*l)
g+ g
CO2p
=
=
(rH2O/100)*patm
0.113
11.3
1
0.2367
tp
Tp
Tg
1.75158
=
=
=
0,9*dgech
0.07
=
=
|tp-tp*|
patm
l
din grafic
f(tp , pH2O*l)
(ta*a+tg*g)/(a+g)
(ta1,II*a1,II+tg*g)/(a1,II+g)
=
C
=>
=
>
757.7388804
1
Agp
=
pCO2
din grafic
din grafic
pH2O
=
=
=
=
=
=
Presiunea atmosferica:
Grosimea medie a stratului radiat:
patm
l
=
=
=
=
=
0,9*dgech
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
tp *
*
Tp
Tg
=
=
=
CO2p*(Tg/Tp*)0,65+*H2Op
0.12246796
0.06
(rCO2/100)*patm
0.074
7.4
0.053
=
=
(rH2O/100)*patm
0.113
11.3
1
0.2367
=
=
=
757.7388804
1030.88888
1172.279453
pCO2*l
pH2O*l
Coeficientul de corectie:
r
qg
1.75158
kPa*m
2.67471
kPa*m
f(pH2O, pH2O*l)
1,15*c0*[(1+p)/2]*[g*(Tg/100)
rg
Se reiau calculele:
- Agentul termic al peretelui
CO2p
f(tp**, pCO2*l)
f(tp**, pH2O*l)
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
pCO2*l
=
pH2O*l
=
Coeficientul de corectie:
=
qrg
=
rg
g
=
=
1.08
*
4
-Agp*(Tp /100) ]
4355.631443
30.80567088
31.05977928
(ta*a+tg*g)/(a+g)
(ta1,II*a1,II+tg*g)/(a1,II+g)
=
C
=>
=
>
789.2540342
1
Agp
din grafic
pCO2
=
=
=
=
pH2O
din grafic
=
=
=
CO2p*(Tg/Tp**)0,65+*H2Op
0.117977582
0.059
(rCO2/100)*patm
0.074
7.4
0.051
=
=
=
0,9*dgech
=
=
(rH2O/100)*patm
0.113
11.3
1
0.2367
patm
l
=
=
tp**
Tp**
Tg
1.75158
=
=
=
kPa*m
=
=
=
789.2540342
1062.404034
1172.279453
2.67471
kPa*m
0.0267471
m*bar
f(pH2O, pH2O*l)
din grafic
1.08
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp**/100)4]
3656.229723
qrg/(tg-tp**)
33.27613916
33.53024756
g+ g
g/(tg-tp***)=a/(tp***-ta)
din grafic
g/(tg-tp**)=a/(tp**-ta)
m*bar
g+ g
|tp*-tp**|
0.0267471
qrg/(tg-tp*)
(ta*a+tg*g)/(a+g)
(ta1,II*a1,II+tg*g)/(a1,II+g)
=
**
***
|tp -tp |
7.064295553
Se reiau calculele:
- Agentul termic al peretelui
CO2p
f(tp***, pCO2*l)
f(tp***, pH2O*l)
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
pCO2*l
=
pH2O*l
=
Coeficientul de corectie:
=
qrg
=
r
=
>
796.3183297
1
Agp
din grafic
pCO2
=
=
=
din grafic
pH2O
=
=
=
0,9*dgech
=
=
(rH2O/100)*patm
0.113
11.3
1
0.2367
796.3183297
1069.46833
1172.279453
2.67471
kPa*m
0.0267471
m*bar
1.08
din grafic
3523.692171
qrg/(tg-tp***)
34.27345274
34.52756114
***
g+ g
2.600953371
f(tp****, pCO2*l)
0.05
=
=
=
Se reiau calculele:
- Agentul termic al peretelui
=
f(pH2O, pH2O*l)
(ta*a+tg*g)/(a+g)
(ta1,II*a1,II+tg*g)/(a1,II+g)
=
>
798.9192831
1
C
=>
Agp
=
pCO2
din grafic
=
=
=
=
=
=
(rCO2/100)*patm
0.074
7.4
=
=
=
kPa*m
CO2p
*** 0,65
tp***
Tp***
Tg
1.75158
g/(tg-tp
=
=
|tp***-tp****|
=
=
=
patm
l
=
C
=>
0
=
0
*** 0,65
****
f(tp
, pH2O*l)
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
pCO2*l
=
pH2O*l
=
Coeficientul de corectie:
=
qrg
=
rg
g
=
pH2O
din grafic
=
=
=
0,9*dgech
=
=
0.05
(rH2O/100)*patm
0.113
11.3
1
0.2367
patm
l
=
=
tp****
Tp****
Tg
1.75158
=
=
=
kPa*m
=
=
=
798.9192831
1072.069283
1172.279453
2.67471
kPa*m
0.0267471
m*bar
f(pH2O, pH2O*l)
din grafic
4
****
1,15*c0*[(1+p)/2]*[g*(Tg/100) -Agp*(Tp
/100) ]
qrg/(tg-tp****)
g+ g
g/(tg-tp*****)=a/(tp*****-ta)
|tp****-tp*****|
(ta*a+tg*g)/(a+g)
(ta1,II*a1,II+tg*g)/(a1,II+g)
=
=
0.248669191
<
799.1679523
1
(ta2,I+tg)/2
538.4397265
qrg1+qrg2
1.08
3444.375956
34.371521
34.6256294
=
=
C
CANALUL INELAR:
tp2,I
qrg
r
qg
1,15*qrg2
=
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp/100)4]
=
=
=
=>
c0
0.79
=
=
CO2+*H2O
5.67
0.11276
CO2
f(tg, pCO2*l)
din grafic
pCO2
=
=
=
din grafic
pH2O
0.062
(rCO2/100)*patm
0.074
7.4
H2O
=
Presiunea partiala pentru H2O:
f(tg, pH2O*l)
0.047
(rH2O/100)*patm
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura gazelor de ardere:
pCO2*l
pH2O*l
Coeficientul de corectie:
tg
1.75158
=
kPa*m
899.1294529
2.67471
kPa*m
0.0267471
m*bar
f(pH2O, pH2O*l)
din grafic
f(tp, pCO2*l)
f(tp, pH2O*l)
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
pCO2*l
=
pH2O*l
=
Coeficientul de corectie:
=
r
qg
=
Agp
din grafic
pCO2
=
=
=
=
pH2O
din grafic
0.068
=
=
=
0,9*dgech
=
=
(rH2O/100)*patm
0.113
11.3
1
0.2367
=
=
=
kPa*m
=
=
=
538.4397265
811.5897265
1172.279453
2.67471
kPa*m
0.0267471
m*bar
f(pH2O, pH2O*l)
1.08
8445.807857
23.41571505
23.66982345
din grafic
4
1,15*c0*[(1+p)/2]*[g*(Tg/100) -Agp*(Tp/100) ]
r
q g/(tg-tp)
c
g+ g
Se reiau calculele:
- Agentul termic al peretelui
(rCO2/100)*patm
0.074
7.4
tp
Tp
Tg
1.75158
CO2 *(Tg/Tp)0,65+*H2Op
0.157259571
0.066
=
=
=
=
=
1.08
p
patm
l
|tp-tp |
1
0.2367
=
=
=
=
rg
0.113
11.3
patm
l
=
=
g
0,9*d ech
292.4265677
(ta*a+tg*g)/(a+g)
(ta2,I*a2,I+tg*g)/(a2,I+g)
=
>
830.8662941
1
=
C
=>
Agp
CO2p*(Tg/Tp*)0,65+*H2Op
CO2
f(tp , pCO2*l)
f(tp*, pH2O*l)
Presiunea atmosferica:
Grosimea medie a stratului radiat:
patm
l
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
pCO2*l
=
pH2O*l
=
Coeficientul de corectie:
=
r
qg
=
rg
din grafic
pCO2
=
=
=
=
pH2O
din grafic
=
=
830.8662941
1104.016294
1172.279453
2.67471
kPa*m
0.0267471
m*bar
f(pH2O, pH2O*l)
din grafic
1.08
-Agp*(Tp*/100)4]
1,15*c0*[(1+p)/2]*[g*(Tg/100)
1706.117401
24.9932384
g+ g
25.24734679
3.884620837
**
f(tp , pCO2*l)
q g/(tg-tp )
Se reiau calculele:
- Agentul termic al peretelui
p
=
=
0.05
(rH2O/100)*patm
0.113
11.3
1
0.2367
=
=
=
CO2
=
=
=
0,9*dgech
-
(rCO2/100)*patm
0.074
7.4
=
=
=
kPa*m
|tp*-tp**|
0.123664414
0.067
tp
Tp*
Tg
1.75158
=
=
f(tp**, pH2O*l)
(ta*a+tg*g)/(a+g)
(ta2,I*a2,I+tg*g)/(a2,I+g)
=
C
=>
=
>
834.750915
1
Agp
=
pCO2
din grafic
din grafic
pH2O
=
=
=
=
=
=
=
=
=
** 0,65
(rCO2/100)*patm
0.074
7.4
=
0.049
(rH2O/100)*patm
0.113
11.3
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
pCO2*l
=
pH2O*l
=
Coeficientul de corectie:
=
r
qg
=
rg
patm
l
=
=
0,9*dgech
=
=
1
0.2367
tp**
Tp**
Tg
1.75158
=
=
=
kPa*m
=
=
=
834.750915
1107.900915
1172.279453
2.67471
kPa*m
0.0267471
m*bar
f(pH2O, pH2O*l)
din grafic
1.08
1,15*c0*[(1+p)/2]*[g*(Tg/100)4-Agp*(Tp**/100)4]
1663.34736
qrg/(tg-tp**)
25.83698564
26.09109404
g+ g
g/(tg-tp***)=a/(tp***-ta)
|tp**-tp***|
1.901597433
Se reiau calculele:
- Agentul termic al peretelui
CO2
***
f(tp , pCO2*l)
f(tp***, pH2O*l)
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
pCO2*l
=
pH2O*l
=
Coeficientul de corectie:
=
r
qg
=
(ta*a+tg*g)/(a+g)
(ta2,I*a2,I+tg*g)/(a2,I+g)
=
>
836.6525124
1
=
C
=>
Agp
=
pCO2
din grafic
=
pH2O
din grafic
=
=
=
=
=
=
CO2p*(Tg/Tp***)0,65+*H2Op
0.12234811
0.067
(rCO2/100)*patm
0.074
7.4
0.049
=
=
=
g
0,9*d ech
=
=
(rH2O/100)*patm
0.113
11.3
1
0.2367
patm
l
=
=
tp***
Tp***
Tg
1.75158
=
=
=
kPa*m
=
=
=
836.6525124
1109.802512
1172.279453
2.67471
kPa*m
0.0267471
m*bar
f(pH2O, pH2O*l)
din grafic
1.08
1596.109924
1,15*c0*[(1+p)/2]*[g*(Tg/100)
***
4
-Agp*(Tp /100) ]
***
q g/(tg-tp )
c
g+ g
g/(tg-tp****)=a/(tp****-ta)
=
=
(ta*a+tg*g)/(a+g)
(ta2,I*a2,I+tg*g)/(a2,I+g)
|tp***-tp****|
0.640344311
<
836.0121681
1
tp2,II
(ta2,II+tg)/2
548.8147265
qrg1+qrg2
qrg
qrg
1,15*qrg2
=
4
1,15*c0*[(1+p)/2]*[g*(Tg/100) -Agp*(Tp/100)4]
=
=
=
25.54718446
25.80129286
=
=
C
=>
c0
5.67
0.79
=
=
CO2+*H2O
0.11276
CO2
f(tg, pCO2*l)
=
Presiunea partiala pentru CO2:
din grafic
pCO2
=
=
=
din grafic
pH2O
0.062
(rCO2/100)*patm
0.074
7.4
H2O
f(tg, pH2O*l)
=
Presiunea partiala pentru H2O:
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura gazelor de ardere:
pCO2*l
pH2O*l
Coeficientul de corectie:
0.047
=
=
=
0,9*dgech
=
=
(rH2O/100)*patm
0.113
11.3
1
0.2367
patm
l
=
=
tg
1.75158
=
kPa*m
899.1294529
=
=
2.67471
kPa*m
0.0267471
m*bar
f(pH2O, pH2O*l)
din grafic
=
Presiunea partiala pentru CO2:
f(tp, pCO2*l)
Agp
din grafic
pCO2
=
=
=
=
=
=
1.08
p
0,65
f(tp, pH2O*l)
=
pH2O
Presiunea atmosferica:
Grosimea medie a stratului radiat:
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
pCO2*l
=
pH2O*l
=
Coeficientul de corectie:
=
r
qg
=
rg
=
=
=
548.8147265
821.9647265
1172.279453
2.67471
kPa*m
0.0267471
m*bar
f(pH2O, pH2O*l)
1.08
1,15*c0*[(1+p)/2]*[g*(Tg/100) -Agp*(Tp/100) ]
8510.705469
qrg/(tg-tp)
24.29445532
24.54856372
din grafic
4
285.5310216
f(tp*, pCO2*l)
g+ g
Se reiau calculele:
- Agentul termic al peretelui
=
=
=
(rH2O/100)*patm
0.113
11.3
1
0.2367
=
=
=
kPa*m
CO2p
=
=
=
0,9*dgech
tp
Tp
Tg
1.75158
0.065
=
=
|tp-tp*|
patm
l
din grafic
f(tp , pH2O*l)
(ta*a+tg*g)/(a+g)
(ta2,II*a2,II+tg*g)/(a2,II+g)
=
C
=>
=
>
834.345748
1
Agp
=
pCO2
din grafic
din grafic
pH2O
=
=
=
=
=
=
Presiunea atmosferica:
Grosimea medie a stratului radiat:
patm
l
=
=
=
=
=
0,9*dgech
Temperatura peretelui:
Temperatura peretelui in grd. K:
Temperatura gazelor de ardere in grd. K
tp *
*
Tp
Tg
=
=
=
CO2p*(Tg/Tp*)0,65+*H2Op
0.123479715
0.068
(rCO2/100)*patm
0.074
7.4
0.049
=
=
(rH2O/100)*patm
0.113
11.3
1
0.2367
=
=
=
834.345748
1107.495748
1172.279453
pCO2*l
pH2O*l
Coeficientul de corectie:
r
qg
rg
g
1.75158
kPa*m
2.67471
kPa*m
f(pH2O, pH2O*l)
1,15*c0*[(1+p)/2]*[g*(Tg/100)
c
m*bar
din grafic
1.08
*
4
-Agp*(Tp /100) ]
1586.533446
24.4896992
24.7438076
g+ g
0.0267471
qrg/(tg-tp*)
g/(tg-tp**)=a/(tp**-ta)
|tp*-tp**|
0.464255485
<
(ta*a+tg*g)/(a+g)
(ta2,II*a2,II+tg*g)/(a2,II+g)
834.8100035
1
=
=
C
W/(m2*K)
W/(m2*K)
W/(m2*K)
2
W/(m *K)
-
W/(m2*K)
-
W/(m2*K)
=
bar
kPa
=
bar
kPa
bar
m
0
C
=
bar
kPa
=
bar
kPa
bar
m
0
C
K
K
W/m2
W/(m2*K)
W/(m2*K)
=
bar
kPa
=
bar
kPa
bar
m
0
C
K
K
W/m2
W/(m2*K)
W/(m2*K)
=
bar
kPa
=
bar
kPa
bar
m
C
K
K
W/m2
W/(m2*K)
W/(m2*K)
=
bar
kPa
=
bar
kPa
bar
m
0
C
K
K
W/m
W/(m *K)
W/(m2*K)
W/(m2*K)
=
bar
kPa
=
bar
kPa
bar
m
0
C
=
bar
kPa
=
bar
kPa
bar
m
0
C
K
K
W/m2
W/(m2*K)
W/(m2*K)
=
bar
kPa
=
bar
kPa
bar
m
0
C
K
K
W/m
W/(m2*K)
W/(m2*K)
=
bar
kPa
=
bar
kPa
bar
m
0
C
K
K
W/m2
W/(m2*K)
W/(m2*K)
=
bar
kPa
=
bar
kPa
bar
m
0
C
K
K
W/m2
W/(m2*K)
W/(m2*K)
=
bar
kPa
=
bar
kPa
bar
m
0
C
K
K
W/m2
2
W/(m *K)
W/(m2*K)
W/(m2*K)
=
bar
kPa
bar
kPa
bar
m
0
C
=
bar
kPa
=
bar
kPa
bar
m
0
C
K
K
W/m2
W/(m2*K)
W/(m2*K)
=
bar
kPa
=
bar
kPa
bar
m
0
C
K
K
W/m2
W/(m2*K)
2
W/(m *K)
=
bar
kPa
=
bar
kPa
bar
m
0
C
K
K
W/m2
W/(m2*K)
W/(m2*K)
=
bar
kPa
=
bar
kPa
bar
m
0
C
K
K
W/m2
W/(m *K)
W/(m2*K)
W/(m2*K)
=
bar
kPa
=
bar
kPa
bar
m
0
C
=
bar
kPa
=
bar
kPa
bar
m
0
C
K
K
W/m2
W/(m2*K)
W/(m2*K)
=
bar
kPa
=
bar
kPa
bar
m
0
C
K
K
W/m
W/(m2*K)
W/(m2*K)
ETAPA 5
CALCULUL INALTIMII RECUPERATORULUI
TEVI (1)
ks1,I
W/(m2*K)
ks1,II
W/(m *K)
16.85921706
ks2,I
W/(m2*K)
17.30906884
ks2,II
W/(m *K)
827.7164259
tmed2,I
698.575419
12.89856643
12.36999079
tmed1,I
tmed1,II
806.4391277
tmed2,II
Q1,I
kW
19.15143388
Q2,I
kW
19.56387584
Q1,II
kW
m2
26.72403758
Q2,II
1.372405089
S2,I
kW
m2
11.99127214
S1,I
S1,II
1.914506201
S2,II
l1,I
1.365156586
l2,I
1.401029393
717.9184196
2.112702552
1.387658445
l1,II
1.904394534
l2,II
0.920219587
H1,I
0.965311479
H2,I
1.401029393
H1,II
1.346610289
H2,II
0.920219587
m
C
1.158
145.47
2.204
=
=
=
=
=
=
1/[(1/g1,I)+(p/p)+(1/g1,I)]
0.0005
40
16.85921706
W/(m2*K)
17.30906884
W/(m2*K)
12.89856643
W/(m *K)
12.36999079
W/(m2*K)
m
W/m/K
1/[(1/g1,II)+(p/p)+(1/g1,II)]
0.0005
40
mm
W/m/K
Canalul inelar:
ks2,I
dp
lp
ks2,II
dp
lp
=
=
=
=
=
=
1/[(1/g2,I)+(p/p)+(1/g2,I)]
0.0005
40
mm
W/m/K
1/[(1/g2,II)+(p/p)+(1/g2,II)]
0.0005
40
mm
W/m/K
Tevi:
tmed1,I
tmax1
tminI
tmed1,II
tmax1
tminII
(tmax-tmin)/ln(tmax/tmin)
t'g-t'a
=
=
t''g-tax,I
(tmax-tmin)/ln(tmax/tmin)
t'g-t'a
=
=
=
=
=
827.7164259
848
807.7589058
806.4391277
848
t''g-tax,II
766.2589058
(tmax-tmin)/ln(tmax/tmin)
717.9184196
Canalul inelar:
tmed2,I
tmax2
tminI
tmed2,II
tmax2
tminII
=
=
t'g-t''a
=
=
t''g-tax,I
(tmax-tmin)/ln(tmax/tmin)
t'g-t''a
=
=
=
=
635
807.7589058
698.575419
635
t''g-tax,II
766.2589058
(DaN/3600)*(iax,I-i'a)
19.15143388
kW
(Da /3600)*(iax,II-i'a)
26.72403758
kW
19.56387584
kW
11.99127214
kW
X Fluxurile de caldura:
Tevi:
Q1,I
Q1,II
=
=
Canalul inelar:
Q2,I
(DaN/3600)*(i''a-iax,I)
Q2,II
(DaN/3600)*(i''a-iax,II)
Q1,I/(ks1,I*tmed1,I)
1.372405089
m2
S1,II
Q1,II/(ks1,II*tmed1,II)
1.914506201
m2
Canalul inelar:
S2,I
Q2,I/(ks2,I*tmed2,I)
2.112702552
m2
S2,II
Q2,II/(ks2,II*tmed2,II)
1.387658445
m2
S1,I/(nt**de)
S1,II/(nt**de)
1.365156586
1.904394534
S2,I/(*d2)
S2,II/(*d2)
1.401029393
0.920219587
l1,II
Canalul inelar:
l2,I
l2,II
H1,I
H1,II
0.965311479
l1,II*cos(45 )
1.346610289
l1,I*cos(45 )
Canalul inelar:
H2,I
l2,I
1.401029393
H2,II
l2,II
0.920219587
m
C
1.158
145.47
lt
2.204
Detalii de citire:
1.400
tax [C]
I
124.5
145.47
0.00
1.300
H1 [m]
0.965
1.347
0.009
-0.179
1.158
H2 [m]
1.401
0.920
-0.012
2.843
1.158
1.158
0
1.158
145.47
0
200
1.158
145.47
1.158
1.200
1.100
H1
1.000
H2
0.900
0.800
0.700
0.600
100
105
110
115
120
125
130
135
140
145
150
155
160
165
170
175
180
185
190
195
200
1.500
II
166
ETAPA 6
CALCULUL PUTERII CONSUMATE DE VENTILATORUL DE AER
DVA
m3/s
0.14596879
pVA
Pa
6224.729888
PVA
1720.864186
p1
Pa
876.3016012
p2
Pa
231.8072956
p3'
Pa
108.9958847
p3''
Pa
332.1614282
p4
Pa
175.4636778
p5
Pa
4500
Puterea consumata de ventilatorul de aer in cazurile in care cuptorul nu este prevazut cu ventilator de gaze de
ardere:
PVA
(DVA*pVA)/(VA*ME)
1720.864186
0.14596879
m3/s
(Da /3600)*(Ta'/T0)
=
VA
0,5...0,7
=
0.6
=
ME
0,85...0,9
=
0.88
Pi - Pa
, unde:
Pa
Pi
=
=
P6 + P7
P1 + P2 + P3 + P4 + P5 + P6 + P7
si
, iar
P1 + P2 + P3 + P4 + P5
Pi
Fiecare din termenii
se compune din pierderi liniare si locale:
Pi
=
[fi*(li/di) + (i)]*(wi2/2)*i
, unde:
fi
=
coeficientul de frecare (coeficientul Darcy);
li
=
lungimea traseului;
di
=
diametrul hidraulic echivalent;
i
wi
i
=
densitatea fluidului in conditii reale.
Calculul coeficientului
fi
necesita stabilirea regimului de curgere a fluidului, pe baza criteriului Reynolds:
Rei
=
(wi*di)/i
, unde
6224.729888
Pa
k/di
r
=
, unde
k
=
rugozitatea absoluta a suprafetei peretelui pe partea fluidului
=
0.001
mm
=
-0,25
- Daca Rei < 10/r, traseul se considera neted hidraulic, iar coeficientul de frecare se determina cu relatia Blasius: f i = 0,3164*Re
- Daca 10/r < Rei < 560/r, traseul se considera semirugos hidraulic, iar coeficientul de frecare se determina cu relatia: f i = 0,11*(r+68/Re)
- Daca Rei > 560/r, traseul se considera rugos hidraulic, iar coeficientul de frecare se determina cu relatia Sifrinson: f i = 0,11*r
In continuare vom analiza fiecare traseu in parte:
i=1
clapeta de reglare (sau un alt organ de reglare):
Pentru clapeta de reglare se recomanda uramatoarele:
X Coeficientul de pierderi locale de presiune pentru o clapeta de reglare deschisa 50% intre 3 si 6.
1
Se alege:
=
5
X Viteza de curgere a aerului:
w1
=
10...20
m/s
w1
Se alege:
=
17
m/s
X Densitatea aerului:
kg/m3
'a
1
=
=
1.212874189
Deci:
P1
=
1*(w12/2)*1
=
876.3016012
i=2
conducta de aer intre ventilator si recuperator:
Pentru conducta de aer dintre ventilator si recuperator se recomanda urmatoarele:
X Viteza de curgere a aerului:
w2
=
10...20
m/s
w2
Se alege:
=
15
m/s
X Diametrul hidraulic echivalent:
d2
=
(4*DVA/*w2)
=
X Lungimea conductelor intre ventilator si recuperator:
l2
=
3...6
m
l2
Se alege:
=
4.5
m
0.111311346
Pa
'a
1.212874189
kg/m3
n'ax104
0.148787073
m2/s
X Numarul Reynolds:
Re2
=
X Rugozitatea absoluta:
r
=
10/r
=
Re2
<
X Coeficientul de frecare:
f2
=
(w2*d2)/2
k/d2
=
1113113.459
10/r
=>
8.983810161
0,3164*Re-0,25
112218.7673
*10^(-6)
0.017287019
>
2320
0,25
10^(-6)
0,25
Deci:
P2
=
[f2*(l2/d2)+2]*(w22/2)*2
i = 3
traseul aerului prin recuperator - primul drum:
X Viteza de curgere a aerului prin tevi in conditii reale:
w3
=
wa1N*{[(ta+tax)/2]+273,15}/T0
=
X Lungimea traseului:
l3
=
1.365156586
m
=
X Diametrul hidraulic echivalent:
d3
daech,1
=
=
0.039
m
X Coeficientul de pierderi locale de presiune:
3
[1-(nt*di2/d22)]2
di
0.039
d2
=
nt
=
X Densitatea aerului:
r3
=
ta1
=
0.111311346
buc
=
(ta+tax)/2
81.73724783
21.04165065
Pa*s
18
145.47
ha106
h310
t
ha10
C
Pa*s
0
17.2
81.73724783
ha106
100
21.9
X Viscozitatea aerului:
n3x104
na1x104
=
=
X Numarul Reynolds:
Re3
=
(w3*d3)/3
X Rugozitatea absoluta:
k/d3
r
=
=
10/r
=
390000
Re3
<
10/r
=>
X Coeficientul de frecare:
0,3164*Re-0,25
f3
=
m/s
0.000321656
raN*T0/(t'a+273,15)
Pa
l1,I
ta
231.8072956
14.80178821
ra
tax
6
1.212874189
Kg/m3
ha/ra
33274.74538
25.64102564
m2/s
0.173485847
>
2320
*10^(-6)
0.023426521
Deci:
P3
=
[f3*(l3/d3)+3]*(w32/2)*3
i = 3
traseul aerului prin recuperator - al II-lea drum:
X Viteza de curgere a aerului prin canalul inelar in conditii reale:
w3
=
wa2N*{[(tax+ta)/2]+273,15}/T0
X Lungimea traseului:
l3
=
1.158
m
12.65773307
108.9958847
m/s
Pa
145.47
ta
231.00
ha106
h310
t
ha10
C
Pa*s
100
21.9
188.2372478
ha106
200
26
X Viscozitatea aerului:
n3x104
na2x104
=
=
X Numarul Reynolds:
Re3
=
(w3*d3)/3
X Rugozitatea absoluta:
k/d3
r
=
=
10/r
=
200000
Re3
<
10/r
=>
X Coeficientul de frecare:
0,3164*Re-0,25
f3
=
25.51772716
0.843544331
Kg/m3
Pa*s
ha/ra
m2/s
0.30250606
8368.5815
50
>
2320
*10^(-6)
0.03308061
2
Deci:
P3
=
[f3*(l3/d3)+3]*(w3 /2)*3
i=4
conducta de aer intre recuperator si arzator:
X Viteza de curgere a aerului:
w4
=
10...20
m/s
w4
Se alege:
=
17
m/s
X Lungimea traseului:
l4
=
3...6
m
l4
Se alege:
=
5
m
X Diametrul hidraulic echivalent:
d4
=
[{(4*DaN/3600)*[1+(t``a/273,15)]}/*w4]
X Coeficientul de pierderi locale de presiune:
Se considera 2 coturi.
4
=
2*0,5
=
1
X Densitatea aerului:
332.1614282
Pa
0.137588486
r4
ra
=
=
X Viscozitatea aerului:
n4x104
nax104
=
=
X Numarul Reynolds:
Re4
=
(w4*d4)/4
X Rugozitatea absoluta:
k/d4
r
=
=
10/r
=
1375884.858
Re4
<
10/r
=>
X Coeficientul de frecare:
0,3164*Re-0,25
f4
=
Deci:
i=5
P4
P5
Se alege:
P5
P3
0.700442963
Kg/m
0.38756903
m /s
=
7.268050041
4500
>
*10^(-6)
175.4636778
Pa
2320
0.020186731
2
P3 + P3
60350.64923
=
[f4*(l4/d4)+4]*(w4 /2)*4
traseul aerului prin arzator:
1...10
*10^3
Pa
=
441.157313
Pa
Pa
(3,72/r)
ETAPA 7
CALCULUL IZOLATIEI TERMICE
Grosimea izolatiei
Se trec datele de la ultima iteratie
Ri
(m*K)/W
0.255922307
Re
(m*K)/W
0.07961903
Riz
(m*K)/W
0
C
0.334202988
tpi
123.9505298
81.9752649
ql
W/m
251.1962273
diz
m
m
0.571257123
0.030628562
tm
iz
Date de intrare:
X Temperatura exterioara:
te
20
W/(m2*K)
(a2,I + a2,II)/2
2.487550927
W/(m2*K)
40
0,045 + 0,00011*tm
0,045 + 0,00011*(tpi+tpe)/2
0.5
mm
0.0005
Presupunem ca:
ql
X Rezistenta interioara:
Ri
1/(*d3*a2)
(m*K)/W
[1/(2**iz)]*ln(diz/d4)
X Rezistenta exterioara:
Re
=
Presupunem initial ca:
X Grosimea izlolatiei:
1/(*sp*e)
(m*K)/W
(m*K)/W
W/m
0
=>
W/(m*K)
iz
20
mm
0.02
d4 + 2iz
0.55
0.551
X Diametrul izlolatiei:
diz
diz + 2sp
X Rezistenta interioara:
Ri
1/(*d3*a2)
0.255922307
(m*K)/W
1/(*dsp*e)
0.082527842
(m*K)/W
242.3424573
W/m
X Rezistenta exterioara:
Re
(tpe - te)/Re
(ta2 - tpi)/Ri
=>
188.2372478
X Temperatura aerului:
ta2
ta2 - ql*Ri
126.216407
(tpi + tpe)/2
83.10820352
0.054141902
W/(m*K)
X Temperatura medie:
tm
0,045 + 0,00011*tm
[(ta2 - te)/ql] - Ri - Re
0.3557627
(m*K)/W
d4*e2**iz*Riz
0.575612887
0.032806444
(d*iz - d4)/2
X Eroarea:
=>
|iz - *iz|
0.012806444
0.575612887
Se reiau calculele:
X Diametrul izlolatiei:
d*iz
d4 + 2*iz
d*iz + 2sp
0.576613
X Rezistenta interioara:
Ri
X Rezistenta exterioara:
1/(*d3*a2)
0.255922307
(m*K)/W
12.80644359
mm
>
mm
Re
1/(*dsp*e)
0.078861992
(m*K)/W
253.6075934
W/m
(tpe - te)/Re
(ta2 - tpi)/Ri
=>
188.2372478
X Temperatura aerului:
ta2
ta2 - ql*Ri
123.3334074
(tpi + tpe)/2
81.6667037
0.053983337
W/(m*K)
X Temperatura medie:
tm
0,045 + 0,00011*tm
[(ta2 - te)/ql] - Ri - Re
0.328591925
(m*K)/W
d4*e2**iz*Riz
0.570130304
0.030065152
(d**iz - d4)/2
X Eroarea:
=>
|*iz - **iz|
0.002741292
0.570130304
Se reiau calculele:
X Diametrul izlolatiei:
d**iz
d4 + 2**iz
d**iz + 2sp
0.57113
X Rezistenta interioara:
Ri
1/(*d3*a2)
0.255922307
(m*K)/W
1/(*dsp*e)
0.07961903
(m*K)/W
251.1962273
W/m
X Rezistenta exterioara:
Re
(tpe - te)/Re
(ta2 - tpi)/Ri
=>
188.2372478
X Temperatura aerului:
ta2
2.74129172
mm
>
mm
tpi
ta2 - ql*Ri
123.9505298
(tpi + tpe)/2
81.9752649
0.054017279
W/(m*K)
X Temperatura medie:
tm
0,045 + 0,00011*tm
[(ta2 - te)/ql] - Ri - Re
0.334202988
(m*K)/W
d4*e2**iz*Riz
0.571257123
0.030628562
(d***iz - d4)/2
X Eroarea:
|**iz - ***iz|
0.00056341
0.563409824
mm
<
mm
ETAPA 8
CALCULUL ECONOMIC
Calculul economic
MR
IR
Miz
Iiz
I
kg
128.6064716
6430.32358
kg
15.06027338
150.6027338
PVA
7080.926314
82.39058405
Can
/an
8444.8988
Tr
ani
0.838485633
I/Can
0.838485633
ani
Investitiile se calculeaza pe baza unui deviz de materiale si lucrari corespunzatoare tuturor fazelor de executie si montaj.
Penteru un calcul aproximativ se vor folisi relatiile urmatoare:
X Investitia in recuperator:
IR
MR * PR
6430.32358
128.6064716
kg
(/4)*(d22 - d12)*H
VR * R
X Valoarea recuperatorului:
VR
(/4)*(d42 - d32)*H
Valoarea virolei
exterioare
Valoarea virolei
interioare
0.015393804
0.016
m3
7800
kg/m3
X Investitia in izolatie:
50
/kg
nt*(/4)*(de2 - di2)*lt
Valoarea
tevilor
0.001
Valoarea
tevilor
Valoarea
virolei
=
nt*(/4)*(de2 - di2)*lt
Iiz
150.6027338
Viz * iz
15.06027338
kg
(/4)*(diz2 - d42)*H
0.060241094
7080.926314
Miz * Piz
X Valoarea izolatiei:
Viz
kg/m3
250
/kg
10
500
IR + Iiz + IVA
X Investitia totala:
I
8444.8988
/an
(DaN/3600)*(ia`` - ia`)
38.71530972
kW
35
/(MW*h)
p3`
p3``
=
=
DaN
Ta
T0
ME
VA
=
=
=
=
=
| [(p3` - p3``)*(DaN/3600)*(Ta/T0)]/(ME*VA) |
108.9958847
Pa
332.1614282
Pa
493
Nm /h
ta+273,15
=
C
273.15
0.6
0.9
85
/(MW*h)
7000
h/an
0.14
-1
an
397.65
82.39058405
ANEXA 1