Sunteți pe pagina 1din 7

1

INCARCAREA DATA DIN ZAPADA

1. INTENSITATEA NORMATA A INCARCARII DIN ZAPADA (Pnz)

Pnz = Cz * Ce * gz (KN/M2)

pentru gz
ZONA IN CARE SE INCADREAZA PRINCIPALELE LOCALITATI DIN TARA DIN
PUNCTUL DE VEDERE AL INTENSITATII INCARCARII DIN ZAPADA SI DIN VANT

ZONA ZONA ZONA


zapada

zapada

zapada
LOCALITATEA LOCALITATEA LOCALITATEA
vant

vant

vant
Adjud C B Craiova C B Petrosani B E
Aiud A B Curtea de Arges B A Piatra Neamt B B
Alba Iulia A A Deva A A Pitesti B B
Arad A A Dorohoi D C Ploiesti B B
Azuga E E Draganesti-Olt C B Predeal E E
Bacau C B Dr. Turnu Severin C C Radauti D C
Baia de arama B A Fagaras B A Roman D C
Baia Mare B A Falticeni D C Rosiori de Vede C C
Baia Sprie E A Fetesti D B Rm. Valcea B A
Baile Govora B A Focsani B B Satu Mare A A
Baile Herculane B B Galati D B Segarcea C C
Baile Olanesti B A Gheorghieni C A Semenic E E
Baile Tusnad C A Giurgiu D B Sf. Gheorghe B A
Bicaz B E Harsova D B Sibiu B A
Bistrita A A Huedin A A Sighetu Marmatiei B A
Barlad C B Hunedoara B A Sighisoara A A
Blaj A A Husi C B Simeria A A
Botosani C C Iasi C C Sinaia E E
Brasov B A Jimbolia A A Sangeorz Bai B E
Braila D B Lugoj A A Slatina C B
Breaza B A Lupeni B E Slanic Prahova B B
Bucuresti C B Mangalia B C Slanic Moldova E B
Buhusi B B Marasesti C B Slobozia D B
Busteni E E Medgidia C B Suceava D C
Buzau B B Medias A A Sulina B C
Buzias A A Miercurea Ciuc C A Tecuci C B
Caracal C C Mizil B B Tg.Jiu B A
Caransebes A D Moldova Noua B C Tg. Mures A A
Carei A A Odobesti B B Targoviste B B
Odorheiu
Calarasi D A Secuiesc A A Timisoara A A
2

Calimanesti B B Oltenita D B Tulcea C B


Cernavoda D B Onesti B B Turnu Magurele D B
Campia turzii A A Oradea A A Urziceni C C
Campina B A Oravita A D Vaslui C B
Campulung
Muscel B E Orastie A A Vatra Dornei E E
Cluj Napoca A A Orsova B C Videle C C
Constanta B C Otelu Rosu A E Voineasa E D
Copsa Mica A A Panciu B B Zalau A A
Corabia D B Pascani D B Zimnicea D B

INTENSITATEA NORMATA A INCARCARII DIN


ZAPADA PENTRU ZONELE A - E

PERIOADA DE REVENIRE
IN ANI
ZONA 10 25 50
GREUTATEA DE
REFERINTA{KN/MP}
A 0,9 1,2 1,5
B 1,2 1,6 2
C 1,5 2 2,5
D 1,8 2,4 3
ATITUDINEA (m)

PERIOADA DE REVENIRE
IN ANI
ZONA 10 25 50
GREUTATEA DE
REFERINTA{KN/MP}
700 1,5 2 2,5
800 1,7 2,25 2,8
900 1,85 2,4 3
1000 2 2,6 3,3
1100 2,2 2,9 3,6
1200 2,4 3,2 4
1300 2,6 3,45 4,3
1400 2,85 3,8 4,7
E 1500 3,1 4,1 5,1
1600 3,4 4,5 5,6
1700 3,7 4,9 6,1
1800 4 5,3 6,6
3

1900 4,4 5,8 7,3


2000 4,8 6,4 8
2100 5,3 7 8,8
2200 5,8 7,7 9,6
2300 6,2 8,3 10,4
2400 6,7 9 11,2
2500 7,2 9,6 12

Pentru Ce
are valori : 0.6 ;0.8 ;1.0; 1.1

Pentru cz

α cz
0°<α <30° 1.0
30°<α <60° (60 – α)/30
α > 60° 0

2. INTENSITATEA DE CALCUL A INCARCARII DIN ZAPADA (Pcz)


PCz = Pnz * Γi (KN/M2)
Pentru Γi
Starile limita si gruparile de Simbolul ZONELE
incarcari coeficientului de
siguranta A,B,C,D E
Coeficienti partiali de siguranta(Γ)
Starile limita ultime de
rezistenta si stabilitate, sub Γa –0.4(gp/ce*gz) Γb –0.4(gp/ce*gz)
ΓF
actiunea gruparilor >0.3 Γa >0.3 Γb
fundamentale
Starile limita ale exploatarii
normale sub efectul Γc –0.2(gp/ce*gz) Γd –0.2(gp/ce*gz)
Γ0
incarcarilor totale de >0.3 Γc >0.3 Γd
exploatare
Starile limita ale exploatarii
normale sub efecte de durata
Starile limita ultime sub
Γ1 Γc Γf
actiunea gruparilor speciale(in
care actiunea zapezii joaca un
rol secundar)
Starea limita ultima de
Γ2 0 0.2
oboseala

Clasa de Γa Γb Γc Γd Γe Γf
4

importanta
a
constructiei
I 2.8 3.0 1.8 2.0 0.40 0.60
II 2.5 2.7 1.6 1.8 0.35 0.55
III 2.2 2.4 1.4 1.6 0.30 0.50
IV 2.0 2.2 1.2 1.4 0.25 0.45
V 1.8 2.0 - - - -

INCARCAREA DATA DIN VANT

1. INTENSITATEA NORMATA A INCARCARII DIN VANT (Pnv)

Pnv = β * Cn * Ch(z) * gv (KN/M2)

Pentru β = 1,6 = coef. de rafala

Pentru Cn

H1/l
α 0.0 0.5 1.0 >2
Cn
0° 0.0 -0.6 -0.7 -0.8
20° +0.2 -0.4 -0.7 -0.8
40° +0.4 +0.3 -0.2 -0.4
60° +0.8 +0.8 +0.8 +0.8

Pentru Ch(z)

Tipul de Inaltimea deasupra terenului Z (in metri)


amplasament 10 20 40 60 80 100 150 200 350
Ch(z)
I 1.00 1.25 1.55 1.75 1.95 2.10 2.40 2.60 3.10
II 0.65 0.9 1.20 1.45 1.65 1.80 2.15 2.45 3.10
III 0.3 0.5 0.75 0.95 1.20 1.35 1.80 2.15 3.10

Pentru amplasamentul de tip I Pentru amplasamentul de tip II Pentru amplasamentul de tip III
0.32 0.44
Ch(z) = (z/10) > 1.00 Ch(z)=0.65(z/10) > 0.65 Ch(z)=0.30(z/10)0.66 > 0.30

Pentru gv
5

Zona Altitudinea Presiunea Dinamica de baza stabilizata la inaltimea de 10 m


deasupra terenului (KN/m2)
A < 800 0.30
B < 800 0.42
C < 800 0.55
D Zone cu conditii deosebite pentru care se cer date din partea INMH
1000 0.40
1200 0.45
1400 0.65
1600 0.90
E
1800 1.10
2000 1.30
2200 1.50
2400 1.70

2. INTENSITATEA DE CALCUL A INCARCARII DIN VANT (PCv)

Pcv = Pnv * Γi (KN/M2)

Pentru Γi

Starile limita si gruparile de incarcari Simbolul ZONELE


coeficien
tului de A,B,C D ,E
siguranta Coeficienti partiali de
siguranta(Γ)
Starile limita ultime de rezistenta si stabilitate,
ΓF Γa Γb
sub actiunea gruparilor fundamentale
Starile limita ale exploatarii normale sub efectul
Γ0 Γc Γd
incarcarilor totale de exploatare
Starile limita ale exploatarii normale sub efecte
de durata
Starile limita ultime sub actiunea gruparilor Γ1 Γe Γf
speciale(in care actiunea vantului joaca un rol
secundar)
Starea limita ultima de oboseala Γ2 0 0.2

Felul Clasa de Γa Γb Γc Γd Γe Γf
6

importanta
constructiei a
constructiei
Constructii I 1.6 1.8 1.4 1.6 0.40 0.60
curente II 1.4 1.6 1.2 1.4 0.35 0.55
putin III 1.2 1.4 1.0 1.2 0.30 0.50
sensibile la IV 1.05 1.25 0.85 1.05 0.25 0.45
actiunea V 0.9 1.1 - - - -
vantului
(C1)

INCARCAREA PERMANENTA

Invelitori(incarcare pe m2 de suprafata inclinata Valoarea


incarcarii(
N/m2)
Carton bitumat de greutate medie intr-un singur strat, acoperit cu
50
bitum si presarat cu nisip
Olane de acoperis, inclusiv mortarul de ciment 1400
Ceramice
Tigle solzi din argila arsa,asezate pe un rand 650
(inclusiv
Tigle solzi din argila arsa,asezate pe doua randuri 850
sipcile si
Tigle cu jgheab, presate 500
capriorii)
Tigle cu jgheab, trase 500
Lemn(inc
lusiv
Sindrila sau sita 400
sipcile si
capriorii)
Placi Ondulate(inclusiv sipcile si capriorii) 200
bituminoa
Plane(inclusiv astereala, stratul de felt si capriorii) 350
se
Geamuri armate(inclusiv sprosurile) de 5mm grosime 300
Sticla
Geamuri armate(inclusiv sprosurile) de 6mm grosime 350
Zincata,neagra sau tip Lindab(inclusiv astereala si
300
capriorii)
Tabla
Ondulata de 1mm grosime(inclusiv sipcile si materialul de
120
fixare)
Tigle de Solzi asezate simplu 900
beton Solzi asezate dublu 1000
BRAMA
C(incl.s,c, Profilate tip ALPINA si Romana 600
si folia)
7