Sunteți pe pagina 1din 10

OPTIMIZAREA FUNCIONRII UNEI PRIZE DE AP

ECOLOGICE PRIN TESTAREA UNUI MODEL


LA SCAR REDUS
Rare Andrei CHIHAIA, Lucian MNDREA, Gabriela OPRINA,
Lucia-Andreea EL-LEATHEY, Bogdan CORBESCU

ECOLOGICAL WATER INTAKE OPTIMIZATION BY SMALL


SCALE MODELLING
The main objective of the paper is to demonstrate the efficiency of an
ecological water intake by optimizing its operation using experimental modelling
techniques. The tests have been performed on a dedicated small scale model
integrated in a specially design testing flume.
This paper presents the general considerations regarding the ecological
intakes for Mountain Rivers and focuses on identifying design methods suitable
for performance increasing. A simplified prototype installation was designed
starting from the patented sand-less ecological intake. Based on this design, a
1:10 small scale model was developed and installed in a dedicated stand. It
was possible to determine the water speed, the flow from the main channel and
the captured flow in different testing conditions, by using specific measuring
equipment and methods. The obtained results were transposed to the prototype
installation by applying Froude similarity criteria, proving to be useful to the
elaboration of the main design parameters for water intakes.

Keywords: water intakes, Mountain Rivers, experimental model, similarity


Cuvinte cheie: prize de ap, ruri de munte, model experimental,
similitudine

1. Consideraii generale

Pentru captarea apei rurilor din zona de munte se folosesc


frecvent prizele tiroleze. Acestea se utilizeaz pentru alimentarea cu

305
ap a microhidrocentralelor fr lac de acumulare i permit captarea
debitelor i concentrarea lor n scopul turbinrii aval de captare.
Soluiile propuse pentru amenajarea de microhidrocentrale cu impact
redus asupra mediului vizeaz n principal circuitul hidraulic al acestora.
Factorul cel mai important care determin funcionarea unei
microhidrocentrale la parametri previzionai este reprezentat de
asigurarea debitului necesar. Avnd n vedere faptul c debitele n albia
unui ru pot avea variaii semnificative, se impune necesitatea unor
prize de ap cu funcionare eficient indiferent de regimul debitelor.
Proiectarea unor astfel de echipamente devine tot mai dificil atunci
cnd trebuie asigurate i condiiile ecologice ale rului prin pstrarea
conectivitii longitudinale i protecia faunei piscicole [1].
Neglijarea condiiilor concrete locale este principala cauz ce
determin dificultile care apar n exploatarea prizelor. Dat fiind rolul
nsemnat pe care l au aceste condiii, nu se pot furniza soluii standard
pentru prizele de ap din ruri. Cu toate acestea, exist aspecte cu
caracter general, care apar la orice priz. Din analizarea acestor
aspecte, se pot desprinde concluzii utile pentru proiectare i chiar
pentru anumite principii de amenajare a prizelor de ap [2].

2. Caracteristici specifice ale prizei de ap ecologice

O soluie brevetat recent, care rspunde cerinelor de


exploatare i are o influen minim asupra mediului este reprezentat
de Priza ecologic de ap din albiile rapide ale rurilor de munte
(PEcAD). Acest concept nou i inovativ se bazeaz pe o priz pe firul
apei, fr baraj, la nivelul talvegului, constnd din: pragul din amonte,
pragul din aval i enalul de legtur [3]. Ea funcioneaz cu energia
cinetic ctigat pe sectorul amenajat, care permite curgerii s fie
mprit n:
- curgere suprateran, printr-un canal superior, ca o continuare a
albiei, cu panta minim necesar;
- curgere subteran, printr-un canal inferior, pe panta albiei, ca o
caset pentru debitul util, placa de separare fiind perforat. Sugestiv,
priza este un ciur hidraulic gravitaional.
Conform [3], pragul din amonte este un ecran de beton cu talpa
la roca de baz i creasta la faa profilului natural al albiei. n axul
albiei, este realizat un canal trapezoidal de seciune optim hidraulic,
cu nlimea h, dimensionat pentru debitul instalat Qi, la panta is.
n seciunea de referin, fundul canalului este aezat la cota
talvegului, care devine cota de baz.

306
Fig. 1 Seciune longitudinal PEcAD

Etajul inferior constituie colectorul pentru apa care cade din


primul etaj prin orificii calibrate, practicate parial n suprafaa de
separare. Odat cu apa, n etajul inferior ajunge i un debit solid trt,
controlat de dimensiunile orificiilor calibrate, evacuat printr-un dispozitiv
de seciune dreptunghiular care comunic cu bieful aval. Debitul de
servitute impus trece pe fundul neperforat al canalului superior i peste
pragul aval, revenind n albie, asigurnd astfel i circulaia petilor [3].
Pragul din aval este, de asemenea, un ecran de beton cu talpa la
roca de baz i creasta cu puin peste profilul natural al albiei, situat la
distana L fa de pragul din amonte. n seciunea de referin, fundul
canalului de sus ajunge la cota [-isL], iar al celui de jos la cota [-iL].
Din diferena de cote, [-iL]-[-isL] = L(i-is), rezult o treapt h
aleas arbitrar h-h. Pantele i i is, treapta h = h i lungimea L sunt
mrimi interdependente care determin, n funcie de debitul instalat Qi,
geometria i mrimea prizei.
Pentru validarea soluiei, autorii brevetului au realizat i un
proiect pilot demonstrativ al prizei. Soluia constructiv a suprafeei
perforate a constat n utilizarea unei benzi din cauciuc de 6 mm
grosime perforat cu ajutorul unei prese.
S-a urmrit n principal funcionarea sub sarcin, modul de
distribuie al debitelor, debuarea precum i tranzitarea spre aval a
sedimentelor din canalul inferior. Proiectul a fost realizat n concordan
cu cerinele tehnice ale brevetului, iar rezultatele obinute au fost
conform ateptrilor, priza funcionnd la parametrii proiectai [4].

3. Proiectarea prototipului prizei de ap ecologice

Soluia analizat anterior reprezint un element important de


noutate pe plan mondial i poate constitui o alternativ viabil pentru
prizele de ap convenionale, i n special pentru prizele tiroleze.
Considernd ideea unei prize de ap care s menin conectivitatea
longitudinal a rului ca fiind oportun i de actualitate pe plan mondial,
se impune aadar necesitatea studierii n amnunt a unui astfel de

307
echipament. Cea mai indicat metod pentru evaluarea caracteristicilor
hidraulice presupune utilizarea unui model la scar redus realizat n
laborator. Pentru a putea asigura ncercri n ct mai multe variante
constructive, a fost necesar modificarea soluiei iniiale de priz
ecologic prin proiectarea unei instalaii prototip simplificate i implicit a
modelului la scar realizat n laborator. Modificrile aduse reduc
complexitatea soluiei iniiale prin nlocuirea canalului inferior cu o
singur camer de captare a apei plasat n spatele taluzului perforat
pe oricare dintre maluri.
Instalaia prototip la care se raporteaz modelul este compus
dintr-un canal trapezoidal betonat cu nlimea H = 0,7 m i lungimea
de 10 m. Acesta are talpa la roca de baz cu taluzurile racordate la
profilul natural al albiei. Paralel cu canalul, este amplasat o camer
de captare cu rol de preluare a debitului printr-o plac perforat dispus
la o anumit nlime fa de baz numit n continuare Hserv. Camera
de ncrcare i canalul prizei au un perete comun care delimiteaz cele
dou curgeri (cea din albie i debitul captat) i pe care este fixat placa
perforat cu posibilitatea rabatrii pentru acces, reparaii i
mentenan. Unghiul de aezare al taluzurilor este de 45o. Necesitatea
studierii mai multor variante constructive a impus posibilitatea
modificrii unghiurilor pe modelul instalaiei.

Fig. 2 Prototipul prizei de ap ntr-o construcie simplificat

308
Din considerente legate de realizarea modelului prizei, unghiul
de aezare al taluzului opus camerei de captare rmne fix (45o) pentru
toate situaiile analizate. Criteriul cel mai important ce trebuie avut n
vedere la proiectarea unei prize ecologice const n asigurarea
debitului de servitute. n general, pentru cazurile prizelor de munte
analizate, cu debite instalate ntre 1-3 m3/s, debitul de servitute
reprezint un procent cuprins ntre 15-25 % din cel instalat. Calculul
suprafeei udate este deosebit de important, supradimensionarea
determinnd pierderi de debit care ar putea fi preluat n camera de
captare. Suprafaa perforat este fix i plasat peste cota Hserv., astfel
c la 45o, rezult Hserv = 12 cm, la 35o Hserv = 10 cm, iar la 25o Hserv = 7,5
cm. Dup stabilirea suprafeei seciunii neperforate, necesar pentru
tranzitarea debitului de servitute, se dimensioneaz orificiile panoului
perforat astfel nct s permit preluarea diferenei de debit de la cel de
servitute pn la debitul instalat. O dat fixat diametrul orificiului, se
poate determina i debitul tranzitat prin acesta. Pentru calculul vitezei
prin orificiul prizei, se admite ipoteza unui rezervor cu orificiu perforat
care debueaz liber la patm. Utiliznd ecuaia lui Bernoulli, se poate
determina debitul fie n funcie de nlimea apei h n canalul principal
folosind relaia (1), fie utiliznd relaii specifice de calcul dezvoltate
special pentru dimensionarea acestor prize [5].
Q = Cc Cv S 2 gh (1)
n care S este suprafaa orificiului, Cc reprezint coeficientul de
contracie, considerat n lucrrile de specialitate ca fiind 0,62, iar Cv
este coeficientul de vitez, ce poate fi scris sub forma:
1
Cv = (2)
1+
Pentru testrile iniiale, se propune utilizarea unei plci perforate
pentru instalaia prototip cu limea de 550 mm i lungimea de 4000
mm. Pentru aceast suprafa considerat, debitul captat estimat este
de 0,281 m3/s pentru orificii cu diametrul de 4 mm.

4. Proiectarea i realizarea modelului prizei de ap

Proiectarea modelului la scar pornete de la caracteristicile


instalaiei prototip i principalele cote de gabarit ale acesteia,
respectnd principiile generale privind realizarea modelelor de laborator
[6, 7]. Conform criteriilor de similitudine geometric i presupunnd
diametrul orificiilor identic pentru prototip i model, rezult c suprafaa
perforat a modelului va fi de 0,022 m2 (55 mm x 400 mm) i va avea

309
un numr de orificii norif. = 440. n figura 3, este reprezentat o seciune
transversal prin modelul prizei n care sunt evideniate dimensiunile
canalului i ale camerei de captare. Suprafaa perforat este mprit
pe lungime, n 10 zone egale cu lungimea de 40 mm, rezultnd 11
seciuni de msur. Pentru fiecare seciune, se determin adncimea
apei n canalul prizei i viteza de curgere. Utiliznd aceste valori, se
poate calcula debitul tranzitat i debitul captat.

Fig. 3 Seciune transversal prin modelul prizei

Alimentarea prizei se face dintr-un rezervor cu volumul de 250 x


250 x 370 mm. Acesta are rolul de linitire i uniformizare a curgerii i
este alimentat cu o pomp submersibil cu debit maxim de 4 l/s.

Fig. 4 Schema instalaiei pentru ncercarea modelului la scar redus


de priz ecologic

310
Viteza s-a determinat cu tubul Pitot-Prandtl i un manometru
diferenial dublu, priza pentru presiunea total i cea pentru presiunea
static fiind racordate individual la cte un tub U. Diferena dintre
presiuni se citete sub forma lui h i permite determinarea vitezei de
curgere cu formula:
V ' = 2 g h (3)
Pentru a raporta viteza apei obinut pe model la instalaia
prototip, se poate utiliza criteriul de similitudine Froude, care permite
calculul vitezei V:
h
V = V' (4)
h'
ncercrile s-au realizat la pante de 1 %, 1,5 % i 2 %. n figura
4, se poate observa sistemul care permite reglarea pantei pentru
diferite variante testate.

5. Analiza datelor i interpretarea rezultatelor obinute

n prim faz, s-au efectuat 9 ncercri (3 unghiuri de aezare


pentru taluzul camerei de captare la cte 3 pante) pe modelul prizei cu
debitul de 4 l/s. Suprafaa perforat testat a avut 440 de orificii de
diametru 4 mm. n urma procesrii datelor obinute pentru fiecare
variant testat, au rezultat mai multe seturi de date ce au putut fi
prelucrate.
Datele relevante ale ncercrilor preliminare sunt centralizate n
tabelul 1.
Tabelul 1
Qt debit Qc - debit
Tipul ncercrii tranzitat [mc/s] captat [mc/s] - Qc/Qt [%]
- prototip prototip
J = 1 % (0,01), 25o 1,2930 0,6581 50,9
J = 1,5 %(0,015), 25o 1,2838 0,6385 49,7
J = 2 % (0,02),25o 1,2842 0,6140 47,8
J = 1 % (0,01), 35o 1,2663 0,3786 29,9
J = 1,5 % (0,015),35o 1,2265 0,3531 28,8
J = 2 % (0,02), 35o 1,2515 0,3187 25,5
J = 1 % (0,01), 45o 1,2025 0,2994 24,9
J = 2 % (0,02), 45o 1,2023 0,2710 22,5

311
Pentru panta J = 1 % (0,01), unghi taluz la 25o, se prezint n
figura 5, variaia principalilor parametri hidraulici caracteristici, de-a
lungul suprafeei perforate (valori transpuse pentru instalaia prototip).

Fig. 5 Parametrii hidraulici pentru ncercri cu panta J = 1 % (0,01),


unghi taluz = 250, Q = 4 l/s

n continuare, se prezint tot sub form grafic, n figura 6,


variaiile debitelor captate n funcie de pant pentru unghiul taluzului
camerei de captare de 25o.

Fig. 6 Variaia debitului captat la diferite pante pentru taluz nclinat la 250

312
Se observ c debitele captate au o variaie redus n funcie de
pant. Acest aspect poate constitui un avantaj important al unei astfel
de prize pentru c permite extinderea ariei de utilizare i n cazul
amplasamentelor care nu dispun de diferene de nivel nsemnate.
De subliniat totui, c valoarea mai mare a debitului captat se
obine la panta de 1 % [1]. Avnd n vedere c viteza de curgere este
direct proporional cu panta, rezult c pentru panta de 1 % viteza
este mai mic fa de celelalte cazuri analizate. Astfel, este de preferat
ca viteza de curgere n canalul prizei s fie redus.

6. Concluzii

Testrile pe modelul prizei au vizat n principal studiul


fenomenului de curgere a apei printr-o suprafa perforat plasat n
lungul curgerii la anumite unghiuri fa de planul orizontal i la anumite
pante.
Pentru a putea asigura ncercri n ct mai multe variante
constructive, a fost necesar modificarea soluiei iniiale de priz
ecologic prin proiectarea unei instalaii prototip simplificate i implicit a
modelului la scar realizat n laborator.
n cazul variantei cu taluzul nclinat la 45o, rezultatele obinute
pe modelul prizei au fost similare cu cele preconizate prin calcul.
Conform valorilor din tabelul 4, se constat c o scdere a
unghiului de aezare a taluzului determin creterea debitului captat,
situaia cea mai favorabil fiind pentru unghiul de 25o. De asemenea,
rezultate bune cu privire la debitul captat se obin la pante relativ
reduse. Modelarea experimental n laborator a prizei de ap ecologice
a permis caracterizarea principalilor parametri hidraulici ce
caracterizeaz funcionarea acesteia i capacitatea de captare.
Concluziile care rezult n urma experimentrilor sunt utile
pentru stabilirea criteriilor principale de proiectare a unei astfel de prize,
limitrile i factorii care determin funcionarea optim a acesteia.
Rezultatele obinute pentru model, respectiv prototip, pot fi
extrapolate i utilizate i n cazul altor amenajri cu date de proiectare
specifice amplasamentului respectiv.

BIBLIOGRAFIE

[1] Chihaia, R., Soluii inovative utilizate pentru amenajarea de


microhidrocentrale cu impact redus asupra mediului, Tez de doctorat susinut
n cadrul Facultii de Hidrotehnic, UTCB Bucureti, 2015.

313
[2] Rzvan, E., Prize de ap din ruri, Editura Tehnic, Bucureti, 1964.
[3] Mlncioiu, C., Voicu, Gh., Huzum-Teodorescu, I., Priz ecologic de ap
deznisipat, din albiile rapide ale rurilor de munte, Brevet de invenie nr.
123457/29.06.2012.
[4] Mlncioiu, C., Voicu, Gh., Paraschiv, Gh., Dumitrescu, M., Priz de ap
ecologic n etapa testrii ca pilot demonstrativ, Revista Energetica, nr.5/ 2014,
pg.177-180.
[5] Mndrea, L., Chihaia, R.A., Bunea, Florentina, Oprina, Gabriela, Voicu, Gh.,
Ivan, C., Modernizarea captrilor secundare Draxin i Cascoe, Editura
Politehnica Press, Buletinul tiinific seria D, Vol. 74, 2012, pag. 273-280.
[6] Sutherland, J., Soulsby, R., Guidelines for physical modelling of mobile
sediments, Coastlab 2010 Proceedings of the Third International Conference
on the Application of Physical Modelling to Port and Coastal Protection, 2010,
Barcelona.
[7] Lynne, E., Frostick, S., McLelland, J., Mercer, T.G., Users Guide to
Physical Modelling and Experimentation: Experience of the HYDRALAB
Network IAHR Design manual, May 20, 2011, ISBN: 9780415609128.

Drd. Ing. Rare - Andrei CHIHAIA


Cercettor tiinific, INCDIE ICPE-CA, membru AGIR
e-mail: rares.chihaia@icpe-ca.ro

Conf. Dr. Ing. Lucian MNDREA


Departamentul de Hidraulic,
Maini Hidraulice i Ingineria Mediului, Universitatea Politehnica Bucureti,
membru AGIR, e-mail: mandrea_lucian@hotmail.com, lucian.mandrea@upb.ro

Dr. Ing. Gabriela OPRINA


Cercettor tiinific gradul II, INCDIE ICPE-CA
e-mail: gabriela.oprina@icpe-ca.ro

Dr. Ing. Lucia-Andreea EL-LEATHEY


Cercettor tiinific, INCDIE ICPE-CA
e-mail: andreea.elleathey@icpe-ca.ro

Ing. Bogdan CORBESCU


ICN Piteti
e-mail: bogdan.corbescu@gmail.com