Documente Academic
Documente Profesional
Documente Cultură
MOLDOVA
NORMATIV N CONSTRUCII
INSTALAII TERMICE, DE VENTILARE I CONDIIONARE A AERULUI
IZOLAIA TERMIC
A UTILAJULUI I A CONDUCTELOR
ISC
93.020
Signature
Not
Verified
Digitally signed by Pantaz Gheorghe
Date: 2012.12.04 16:19:26 +02:00
Reason: validate document
Location: www.cts.md
CHIINU * 2007
ICS 91.140.10
SA Gradient-Co
Secretar:
ing. I. Safonova
SA Gradient-Co
Membri:
ing. P. Eremeev
ing. L. Reti
IP Ceproserving
ing. I. Poneatenco
IP Chiinuproiect
ing. A. Ovseanicov
IP Iprocom
ing. L. Erocenco
ing. V. Babici
SA Termocom
APROBAT
ACDT RM
2006
Cuprins
PREAMBUL NAIONAL ........................................................................................................................................... IV
NTRODUCERE...............................................................................................................................................................V
............................................................................................................................................................ .......VI
PREFA ...................................................................................................................................................................... VII
....................................................................................................................................................... VIII
1.
................................................................................................................................ 1
1.
2.
.............................................................................................................................. 1
2.
REFERINE NORMATIVE.................................................................................................................................. 1
3.
......................................................................................................................... 1
3.
TERMENI I DEFINIII....................................................................................................................................... 1
4.
...................................................................................................................................... 3
4.
5.
........................... 6
5.
6.
......................................................................................... 13
6.
(). ,
.......................................................................................................................... ..49
ANEXA A (OBLIGATOARE). LISTA ACTELOR NORMATIVE LA CARE SE FAC REFERIN N TEXT 49
().
.................................................................... 50
ANEXA (DE REFERIN). GROSIMEA LIMIT A CONSTRUCIILOR DE IZOLAIE TERMIC PENTRU UTILAJ ICONDUCTE ................................................................................................................... ............51
().
..................................... 52
ANEXA B (DE REFERIN). DETERMINAREA GROSIMII I VOLUMULUI PIESELOR DE IZOLAIE
TERMIC DIN MATERIALE DE COMPACTARE..............................53
PREAMBUL NAIONAL
Prezentul normativ n construcii reprezint adoptarea la condiiile naionaleale Moldovei a normativului interstatal MCH 4.02-03-2004 i traducerea autentic a textului acestui normativ.
Normativul naional n construcii NCM G.04.08-2006 (MCH 4.02-03-2004)
Izolaia termic a utilajului i a conductelor conine cerine obligatorii de proiectare
a izolrii suprafeei exterioare a utilajului, conductelor de evi, canalelor de gaze, conductelor de aer, amplasate n cldiri, construcii i n exteriorul cldirilor (la aer deschis) cu temperatura substanelor, care se conin n ele de la minus 180 pn la 600 oC,
inclusiv conductelor reelelor termice.
Normativul naional n construcii NCM G.04.08-2006 (MCH 4.02-03-2004)
Izolarea termic a utilajului i a conductelor va nlocui normativul n construcii
2.04.14-88.
NTRODUCERE
Prezentele norme i reguli elaborate cu evidena tendinelor contemporane n
proiectarea izolrii termice industriale i recomandrilor organizaiilor internaionale
de standardizare i normare.
Documentul normativ conine cerine fa de construciile termoizolate, piesele
i materialele, ce se includ n componena construciilor, norme de densitate a fluxului termic din partea suprafeelor izolate a utilajului i a conductelor cu temperaturi
pozitive i negative la amplasare lor la aer deschis, n ncperi, canale ne trectoare i
la pozarea fr canale. n document snt expuse regulile de determinare a volumului
i grosimii materialelor compactate fibroase termoizolate n dependena de coeficientul de compactare.
Prezentele norme snt elaborate de candidatul n tiine tehnice B. M. oihet
(condu-ctorul temei), L. V. Stavricaia, candidatul n tiine tehnice V. G. PetrovDenisov (OAO Compania Inginiring pe construcii termotehnice ),
V. A. Gluharev, (Gosstroi al Rusiei); L. S. Vasilieva ( ).
La elaborare au participat: candidatul n tiine tehnice E. G. Ovciarenco, V. S.
Goludov (Uniunea Concern STEPS); A. S. Meleh (ZAO Compania Holding
Rosteploizoleaia); candidatul n tiine tehnice I. A. Covleanschi, A. I. Corotcov,
candidatul n tiine tehnice G. H. Umerchin (OAO VNIPI Anergoprom); V. N.
Iacunicev (SPCB filiala A.O. Firma Anergozaita); candidatul n tiine tehnice A.
V. Sladcov (GUP NII Mosstroi).
.
, , ,
, ,
.
.
- . . .. ( ), .. , . . .. - (
), .. ( ); .. ( ).
: . . .. , ..
( ); .. (
); . . .. , .. , .
. .. ( ); .. (
); . . .. (
Prefa
1. Elaborat de compania inginiring de construcii termotehnica OAO i de un grup de specialiti.
2. Propus de Gosstroi al Rusiei.
3. Acceptat de Comisia tehnico tiinific Interstatal de standardizare reglementare tehnic i certificare n construcii () 20 septembrie 2004.
Pentru acceptare au votat:
Denumirea scurt a statului
Armenia
AR
Kazahstan
KZ
Cirghizia
KG
Moldova
MD
Federaia Rus
Tadjichistan
RU
TJ
Uzbechistan
UZ
4. INLOCUITE 2.04.07-86*
Prezentul document normativ nu poate fi reprodus integral sau parial, tiprit
sau rspndit n calitate de ediie oficiala fr acordul Secretariatului Comisiei tehnico tiinifice Interstatale de standardizare, reglementare tehnic i certificare n construcii ().
1.
.
2.
3. -
,
() 20 2004 .
:
( 3166) 004-97
( 3166) 004-97
AR
KZ
KG
MD
RU
TJ
UZ
4. 2.04.14-88
, -
,
Ediie oficial
1.
1. Domeniul de aplicare
, , , ,
180 600 C,
, .
, , .
, , ,
, .
2.
2. Referine normative
,
, .
3.
3. Termeni i definiii
Prezentele norme nu se extind la proiectarea izolrii termice a utilajului i conductelor, ce conin i transport substane explozive, depozite izotermice a gazelor lichefiate,
cldirilor i ncperilor pentru producerea i
pstrarea substanelor explozive, a staiilor
atomice i instalaiilor.
, , /3 , ,
.
,
/(), ,
, .
, ,
.
, , /()
, ,
.
. , ( ) (
)
.
,
. ,
.
,
(), -
. , .
, .
,
.
,
.
, , ,
.
.
,
(, ) .
4.
4. Principii generale
4.1.
,
,
.
4.2.
:
;
, , ,
;
.
, ,
, , ,
,
, .
4.3. , (20 ),
:
;
;
;
;
,
;
;
;
;
;
;
- ;
-
;
;
;
;
(, , .).
:
;
.
19
,
a.
4.4.
:
;
;
.
4.5.
:
;
;
;
12 .
12 ,
-
zolant;
conductibilitatea termic a materialului
termoizolant;
deformaiile de temperatur a suprafeelor
ce se izoleaz;
configuraia i dimensiunile suprafeei ce
se izoleaz;
condiiile montrii (constrngerea, mari
nlimi, sezonierie i altele).
Construcia termoizolant a conductelor
reelelor termice cu pozare subteran fr canale trebuie s reziste fr distrugere:
.
( ) .
.
4.6.
:
;
.
.
5.
5. Cerine fa de materiale i
construcii de izolaie termic
5.1.
20 300 , ,
200 /3 0,06
/() 25 .
50 .
5.2.
300
350 /3 300
0,12 /().
5.3.
300
, , 200 /3
125 0,08 /().
5.4.
400 / 3 0,07
/() 25
,
.
5.5.
200 /3
0,05 /() 40 0,04 /() 40 .
19 0 .
5.6. ,
,
( , , ).
5.7.
0,4 .
-
( 30732)
.
.
5.8.
.
5.9.
.
5.10.
,
,
.
, , ,
(
).
, .
5.11. , , .
, , .
5.12.
-
, .
4640
5
.
5.13. ,
, 0,9 ( 5,0 /(24).
5.14. .
,
.
5.15.
() (, )
,
, , ,
.
5.16.
1.
5.17. -
5.12. La proiectrarea obiectelor cu cerine sanitaro-igienice sporite la coninutul prafului n aerul ncaperilor n construciile de termoizolare nu se permite aplicarea materialelor, ce impurific aerul n ncperi.
.
, .
( 10354);
( 9438);
( 25951)
( 618)
( 10296)
( 10923)
60
61 100
19
100
8
12
8
12
8
12
0,15-0,2
0,21-0,3
0,31-0,5
0,06-0,1
2
1
1,5
1
3
2
2
3
2
3
2
-
2
-
2
-
.
1. ,
, .
2. , 0,1 /(),
.
Tabelul 1
Grosimea,mm
0,15-0,2
0,21-0,3
0,31-0,5
0,06-0,1
2
1
1,5
1
3
2
2
3
2
3
2
-
2
-
2
-
5.18. 3
4
, :
) , IV
,
;
) , ;
) ,
,
.
3 4
:
2 ;
0,4 ;
,
I II
3
30 ;
.
1 2,
6 ,
.
5.19.
.
-
3 4, :
3 100 ;
5 ,
.
.
.
NCM G 04. 07-2006 ( 4.02-02-2004)
5.20.
,
, .
, , ,
,
.
5.21. ,
,
.
( , , ).
6.
red
1400 ql
(2);
qlred ql K ,
:
q , /2, 2-7;
ql
( 1 ), /2,
2 - 12.
2 12 . 27.
,
( ), 13.
unde:
q densitatea fluxului termic normat, Vt/m2,
ce se accept n conformitate cu tabelele 2-7;
ql densitatea liniar normat a fluxului termic (la 1 metru lungime a obiectului cilindric), Vt/m2, ce se accept conform tabelelor
2 12.
Tabelele 2 12 snt anexate pe pagina 27.
Coeficientul K, ce ia n consideraie costul cldurii i construciei termoizolante n
dependen de raionul de construcie i metoda de pozare a conductelor (locul de instalare
a utilajului), trebuie s se aplice conform tabelei nr.13.
13. , ( )
1,0
0,98
0,98
0,98
0,96
1,0
0,98
0,98
0,98
0,96
1,0
0,95
0,95
0,95
0,92
1,0
0,94
0,94
0,94
0,9
0,96
0,96
0,92
0,9
Tabela nr. 13. Coeficientul , care ea n consideraie variaiile costului cldurii n dependen
de zona de construcie i metoda de pozare a conductei (locul instalrii utilajului)
Metoda de pozare a utilajului i locul amplasrii utilajului
Zona de construcie
La aer liber
n ncpere,
tunel
n canalul ne
trector
Fr canal
1,0
0,98
0,98
0,98
1,0
0,98
0,98
0,98
1,0
0,95
0,95
0,95
1,0
0,94
0,94
0,94
Extremul orient
Regiunile extreme ale nordului
i cele ce se egaleaz cu ele
0,96
0,96
0,92
0,9
0,96
0,96
0,92
0,9
6.1.3. ,
,
, , .
,
.
6.1.4.
k (3)
6.1.3. Caracteristicile calculate a materialelor termoizolante i articolelor, ce se aplic la izolarea utilajului i conductelor cu pozarea suprateran i subteran trebuie s fie
acceptate cu contul densitii n construcii,
umiditii n condiiile de exploatare, rosturi i
influenei punii de frig a elementelor de fixare.
Coeficientul de conductibilitate termic a
materialelor comprimate n cazul densitii
optimale n construcii trebuie de aplicat conform datelor ncercrilor de certificare sau
conform datelor, prezentate n Codul practic
privind proiectarea izolaiei termice.
6.1.4. La pozarea fr canale a conductelor, conductibilitatea termic a stratului
principal a construciei de termoizolare k se
determin dup formula (3)
k = K ,
:
, /();
K , ,
14.
(3)
unde:
conductibilitatea termic a materialului
uscat a stratului principal, Vt/(m K);
K coeficientul ce ine cont de mrirea conductibilitii de la umezire, care se accept n
dependen de tipul materialului termoizolant
i tipul de sol conform tabelului 14.
14
25100
1,0
1,05
1,05
1,0
1,05
1,05
1,0
1,1
1,1
Puin umezit
Coeficientul de umezire
Tipul solului conform 25100
Umed
nbibat cu ap
1,0
1,05
1,0
1,05
1,0
1,1
1,05
1,05
1,1
Tabelul 14
Materialul stratului termoizolant
Porliuretan expandat
Armobeton celular
Polimermineral expandat
6.1.5. :
) ,
:
;
;
, ,
8 ;
) ,
, 20 ;
) ,
, 40 ;
)
.
(
)
( ) 0,7
,
.
6.1.6.
.
:
) :
;
-
15;
15
,
tw,
9570
65
15070
90
18070
110
Tabelul 15
Regimurile de temperatur a reelelor termice de ap,
Temperatura calculat a ajentului termic tw,
9570
65
15070
90
18070
110
50 ;
)
, ;
)
.
6.1.7.
:
;
(
);
.
6.2.
.
6.1.5 6.1.6.
.
6.3.
() ,
.
,
:
0,92;
;
,
, , 20 .
.
6.4.
, ().
, :
6.3;
40 ;
.
.
6.5.
.
6.3.
.
6.6.
.
6.3 6.5.
6.7.
-
.
6.7.1.
, :
) ,
:
100 ...45
100 .35
45 ..35;
) ,
:
..55
..60.
,
, , 75 .
6.7.2.
, :
;
6.1.5, ,
.
6.8.
, .
,
.
.
6.9.
, , ,
izolaiei.
6.7.1. Temperatura la suprafaa izolaiei
termice trebuie de acceptat nu mai mare, :
) pentru suprafee izolate, amplasate n
zona de lucru sau de deservire a ncaperilor i
care conin substane:
cu temperatura mai mare de 100 45
cu temperatura 100 i mai joas .....35
cu temperatura izbucnirii vaporilor
mai joas de 45 ...........................35;
b) pentru suprafeele ce se izoleaz, amplasate la aerul atmosferic n zona de lucru
sau de deservire:
n caz cu stratul de acoperire
din metal..............55
n caz cu alte tipuri de straturi
de acoperire.60.
Temperatura la suprafaa izolaiei termice a conductelor, amplasate dup limitele
zonei de lucru sau de deservire, nu trebue s
depeasc limitele de temperatur de utilizare a materialelor a stratului de acoperire,
dar maxim de 75 .
6.7.2. Temperatura calculat a aerului
atmosferic trebuie de acceptat pentru suprafeele, amplasate:
la aerului atmosferic media maxim a lunii mai calde;
n ncpere n conformitale cu 6.1.5, , i
.
6.8. Determinarea grasimii izolaiei termice n scopul prentmpinrii condensrii
umezelii din aerul atmosferic pe stratul de
acoperire a izolaiei termice a utilajului i a
conductelor, ce conin substane cu temperatura mai joas de temperatura aerului atmosferic.
Acest calcul necesit a fi executat numai
pentru suprafee amplasate n ncpere.
Temperatura calculat i umiditatea relativa a aerului se accept n conformitate cu
tema de proiectare.
6.9. La calcului grosimii izolaiei termice
cu scopul preintmpinrii condensrii pe suprafeele interioare a obiectelor, ce transport
substane n form de gaze i care conin vapori de ap sau vapori de ap i gaze, care la
dizolvarea n vapori de ap condensai pot s
, 6.3.
6.10.
, , , 6.1, 6.2 6.8.
.
6.11. , , , .
,
, ,
. .
6.12.
(, , ) 10
.
, , ,
.
,
.
, -
3 .
6.13. :
, ;
, , 20 ;
20
;
,
, .
6.14.
.
,
, .
.
6.15.
,
.
, 120 .
.
6.16. -
350 60
. .
6.17. .
6.18. ,
, ,
16.
16 -
,
..
, , ,
.1600
350 . 350 600 . 600 1600
0,5
0,5
0,8
0,8
0,5
0,8
0,8
1,0
0,3
0,5
0,8
1,0
0,25
0,3
0,8
1,0
0,5
0,5
0,8
0,8
0,5
0,8
0,8
1,0
0,3
0,5
0,8
1,0
0,25
0,3
0,8
1,0
6.19.
1600 ,
, 0,70,8 , 600
1600 0,6 .
6.20.
0,250,3
.
6.21.
, , .
17.
17
()
,
,
133 .
159
10
15
15
1520
20
2025
Tabelul 17
Tipul materielului de izolaie (temei)
Piese aspre
Piese fibroase
10
15
6.22. , ,
.
.
6.23.
1
1212 .
6.24.
15
1520
utilajul
20
2025
. ,
.
34 .
6.25.
, .
0,23 / ().
.
,
, .
6.26.
17314.
6.27. ,
,
- .
,
,
:
40 400
;
400 40
, .
,
Elementele de fixare a stratului de termoizolaie i stratului de acoperire a construciilor de termoizolaie a utilajului i conductelor
amplasate la aerului atmosferic n raionalele
cu
temperatura
calculat
a
aerului
nconjurator mai joas de minus 40 , trebu-
40 ,
.
6.28.
.
,
,
.
.
6.29.
,
40 , .
6.30.
.
6.31.
;
60
.
6.32.
(, )
,
2. 5000
.,
20
15
20
25
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
700
800
900
1000
1400
4
4
5
5
6
7
8
9
10
11
14
16
18
22
25
27
30
34
38
43
47
52
70
50
100
150
200
,
250
300
350
400
450
500
550
600
81
89
95
106
115
127
135
146
159
182
212
236
259
281
301
322
343
382
416
453
490
527
670
94
103
111
123
133
147
156
168
183
209
242
270
296
320
343
365
389
432
470
511
552
592
750
109
119
128
142
153
169
179
192
208
238
274
305
333
361
385
410
436
484
526
571
616
660
833
124
135
145
161
173
191
202
217
235
267
308
342
373
403
430
457
486
537
583
633
681
729
918
140
152
163
181
195
214
226
243
263
298
343
380
414
446
476
505
537
593
642
696
749
801
1098
1400
, /2
15
27
41
54
66
77
89
100
110
134
153
174
192
, /
9
10
11
12
14
16
17
19
21
23
28
33
39
45
49
54
58
67
75
83
91
100
133
17
19
20
23
26
29
31
34
38
42
50
57
67
77
84
91
98
112
124
137
150
163
215
25
28
31
35
38
43
46
50
55
61
72
82
95
108
117
127
136
154
170
188
205
222
291
35
39
42
47
51
58
62
67
74
80
95
107
124
140
152
163
175
197
217
238
259
281
364
45
50
54
60
66
74
78
85
93
101
119
133
153
173
187
200
215
241
264
290
315
340
439
56
62
67
75
81
90
96
104
114
132
154
173
191
208
223
239
256
286
313
343
372
400
514
68
75
81
90
98
108
115
124
136
156
182
204
224
244
262
280
299
333
364
397
430
463
591
Tabelul 2. Normele de densitate a fluxului termic a utilajului cu temperaturi pozitive la amplasarea la aer deschis i numrul de ore de lucru mai mare de 5000
200
400
450
500
550
600
35
39
42
47
51
58
62
67
74
80
95
107
124
140
152
163
175
197
217
238
259
281
364
45
50
54
60
66
74
78
85
93
101
119
133
153
173
187
200
215
241
264
290
315
340
439
81
89
95
106
115
127
135
146
159
182
212
236
259
281
301
322
343
382
416
453
490
527
670
94
103
111
123
133
147
156
168
183
209
242
270
296
320
343
365
389
432
470
511
552
592
750
109
119
128
142
153
169
179
192
208
238
274
305
333
361
385
410
436
484
526
571
616
660
833
124
135
145
161
173
191
202
217
235
267
308
342
373
403
430
457
486
537
583
633
681
729
918
140
152
163
181
195
214
226
243
263
298
343
380
414
446
476
505
537
593
642
696
749
801
1098
Mai mare de
Densitatea fluxului termic, Vt/m
1400 i suprafee pla15
27
41
54
66
77
89
100
110
ne
Not Semnificaiile intermediare a normelor de densitate a fluxlui termic trebuie s fie determinate prin interpolare.
134
153
174
192
20
50
100
150
15
20
25
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
700
800
900
1000
1400
4
4
5
5
6
7
8
9
10
11
14
16
18
22
25
27
30
34
38
43
47
52
70
9
10
11
12
14
16
17
19
21
23
28
33
39
45
49
54
58
67
75
83
91
100
133
17
19
20
23
26
29
31
34
38
42
50
57
67
77
84
91
98
112
124
137
150
163
215
25
28
31
35
38
43
46
50
55
61
72
82
95
108
117
127
136
154
170
188
205
222
291
56
62
67
75
81
90
96
104
114
132
154
173
191
208
223
239
256
286
313
343
372
400
514
68
75
81
90
98
108
115
124
136
156
182
204
224
244
262
280
299
333
364
397
430
463
591
3. 5000
20
50
100
150
200
15
20
25
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
700
800
900
1000
1400
4
5
5
6
7
8
9
10
12
13
16
19
22
27
30
33
36
42
47
53
59
64
87
10
11
12
14
16
18
20
22
25
27
34
39
44
54
60
65
71
82
91
102
112
123
165
18
21
23
26
29
33
36
39
44
48
59
67
76
92
100
109
118
135
150
166
183
199
264
28
31
34
39
43
48
52
57
63
70
83
95
106
128
139
150
162
185
204
226
248
269
355
38
42
46
52
57
65
69
76
84
92
109
124
138
164
178
192
207
235
259
286
312
339
444
,
250
300
350
, /
49
54
59
67
73
82
88
96
113
123
146
166
184
202
219
235
253
285
314
346
377
408
532
61
67
73
82
90
100
107
116
137
149
176
199
220
241
260
280
300
338
371
407
443
479
621
74
81
88
99
107
120
128
139
162
176
207
234
258
282
304
326
349
391
429
470
511
552
712
400
450
500
550
600
87
96
104
116
126
141
150
162
189
205
240
270
297
324
349
373
399
447
489
535
581
626
804
102
112
120
135
146
162
172
187
216
235
274
307
338
368
395
422
451
504
551
602
652
702
898
117
128
138
154
167
185
197
212
245
266
310
346
380
413
443
473
505
563
614
670
725
780
995
133
146
157
174
189
209
222
239
276
298
347
387
424
460
493
526
561
624
679
740
800
860
1092
150
164
176
196
212
234
248
267
307
332
385
429
469
508
544
580
618
686
746
812
877
941
1193
158
174
191
205
1400
, /2
19
35
54
70
85
99
112
125
141
Tabelul 3. Normele de densitate a fluxului termic a utilajului cu temperaturi pozitive la amplasarea la aer deschis i numrul de ore de lucru 5000 i mai puin
200
400
450
500
550
600
38
42
46
52
57
65
69
76
84
92
109
124
138
164
178
192
207
235
259
286
312
339
444
49
54
59
67
73
82
88
96
113
123
146
166
184
202
219
235
253
285
314
346
377
408
532
87
96
104
116
126
141
150
162
189
205
240
270
297
324
349
373
399
447
489
535
581
626
804
102
112
120
135
146
162
172
187
216
235
274
307
338
368
395
422
451
504
551
602
652
702
898
117
128
138
154
167
185
197
212
245
266
310
346
380
413
443
473
505
563
614
670
725
780
995
133
146
157
174
189
209
222
239
276
298
347
387
424
460
493
526
561
624
679
740
800
860
1092
150
164
176
196
212
234
248
267
307
332
385
429
469
508
544
580
618
686
746
812
877
941
1193
Mai mare de
Densitatea fluxului termic, Vt/m
1400 i suprafee pla19
35
54
70
85
99
112
125
141
ne
Not Semnificaiile intermediare a normelor de densitate a fluxlui termic trebuie s fie determinate prin interpolare.
158
174
191
205
20
50
100
150
15
20
25
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
700
800
900
1000
1400
4
5
5
6
7
8
9
10
12
13
16
19
22
27
30
33
36
42
47
53
59
64
87
10
11
12
14
16
18
20
22
25
27
34
39
44
54
60
65
71
82
91
102
112
123
165
18
21
23
26
29
33
36
39
44
48
59
67
76
92
100
109
118
135
150
166
183
199
264
28
31
34
39
43
48
52
57
63
70
83
95
106
128
139
150
162
185
204
226
248
269
355
61
67
73
82
90
100
107
116
137
149
176
199
220
241
260
280
300
338
371
407
443
479
621
74
81
88
99
107
120
128
139
162
176
207
234
258
282
304
326
349
391
429
470
511
552
712
4. 5000
,
50
100
150
200
,
250
300
350
400
, /
15
20
25
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
700
800
900
1000
1400
6
7
8
9
10
12
13
14
16
18
22
26
29
33
36
39
43
49
55
61
67
74
99
14
16
18
21
23
26
28
31
35
38
46
53
60
66
72
78
84
96
107
118
130
141
187
23
26
28
32
36
41
44
48
53
58
70
79
88
97
106
114
123
139
153
169
185
201
263
33
37
40
45
50
56
60
65
72
79
93
106
118
129
139
150
161
181
200
220
239
259
337
43
48
52
59
64
72
77
84
92
100
118
134
148
161
174
187
200
225
247
270
294
318
411
54
60
65
73
80
89
95
103
113
123
144
162
179
195
210
225
241
269
295
322
350
377
485
66
73
79
89
96
107
114
124
136
147
172
193
212
230
247
264
282
315
344
376
407
438
561
79
87
94
105
114
127
135
146
159
172
200
224
246
267
286
305
326
363
395
431
466
501
638
1400
, /2
23
41
56
69
82
94
106
118
450
500
550
600
93
102
110
122
133
147
156
169
184
199
230
257
281
305
326
348
370
412
448
487
527
565
716
107
117
126
141
152
169
179
193
210
226
262
291
318
344
368
392
417
462
502
546
589
631
797
122
134
144
160
173
191
202
218
237
255
294
327
357
385
411
437
465
515
558
606
653
699
880
138
151
162
180
194
214
227
244
265
285
328
364
396
428
456
484
514
569
616
668
718
768
964
130
141
153
165
Tabelul 4. Normele de densitate a fluxului termic a utilajului cu temperaturi pozitive la amplasare n ncpere i numrul de ore de lucru
mai mult de 5000
Trecerea condiionat
a conductei, mm
50
100
150
200
250
15
20
25
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
700
800
900
1000
1400
6
7
8
9
10
12
13
14
16
18
22
26
29
33
36
39
43
49
55
61
67
74
99
14
16
18
21
23
26
28
31
35
38
46
53
60
66
72
78
84
96
107
118
130
141
187
23
26
28
32
36
41
44
48
53
58
70
79
88
97
106
114
123
139
153
169
185
201
263
33
37
40
45
50
56
60
65
72
79
93
106
118
129
139
150
161
181
200
220
239
259
337
43
48
52
59
64
72
77
84
92
100
118
134
148
161
174
187
200
225
247
270
294
318
411
54
60
65
73
80
89
95
103
113
123
144
162
179
195
210
225
241
269
295
322
350
377
485
66
73
79
89
96
107
114
124
136
147
172
193
212
230
247
264
282
315
344
376
407
438
561
79
87
94
105
114
127
135
146
159
172
200
224
246
267
286
305
326
363
395
431
466
501
638
Mai mare de
Densitatea fluxului termic, Vt/m
1400 i suprafe23
41
56
69
82
94
106
118
e plane
Not Semnificaiile intermediare a normelor de densitate a fluxlui termic trebuie s fie determinate prin interpolare.
450
500
550
600
93
102
110
122
133
147
156
169
184
199
230
257
281
305
326
348
370
412
448
487
527
565
716
107
117
126
141
152
169
179
193
210
226
262
291
318
344
368
392
417
462
502
546
589
631
797
122
134
144
160
173
191
202
218
237
255
294
327
357
385
411
437
465
515
558
606
653
699
880
138
151
162
180
194
214
227
244
265
285
328
364
396
428
456
484
514
569
616
668
718
768
964
130
141
153
165
5.
5000
50
15
20
25
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
700
800
900
1000
1400
6
7
8
10
11
13
14
16
18
21
26
30
34
38
42
46
51
58
65
73
81
89
120
100
150
200
,
250
300
350
400
450
500
550
600
99
109
118
132
144
161
171
186
203
221
258
290
319
347
373
398
426
476
520
568
616
663
850
114
126
136
152
165
184
195
212
231
251
292
327
359
391
419
448
478
533
582
635
687
739
943
130
143
154
172
187
208
221
239
261
282
328
366
402
436
467
498
532
592
645
703
760
816
1038
147
161
174
194
210
233
247
267
291
315
365
407
446
483
517
551
587
652
710
772
834
896
1136
, /
16
18
20
23
25
29
32
35
39
44
53
62
70
77
85
92
100
114
127
141
156
170
226
25
28
31
36
40
45
49
54
60
66
80
92
103
113
123
134
144
164
182
202
221
241
318
35
40
43
49
54
62
66
73
81
89
107
122
136
149
162
175
189
214
236
261
285
309
406
46
52
56
64
70
79
85
93
103
113
134
153
170
186
201
217
233
263
290
320
349
378
492
58
65
70
80
87
98
105
115
126
138
163
185
205
224
242
260
279
314
345
379
413
447
580
71
79
85
96
105
118
126
137
151
164
194
218
241
263
284
305
327
367
402
441
479
518
668
85
93
101
114
124
139
148
161
176
192
225
253
279
304
328
351
375
420
460
504
547
590
758
1400
, /2
46
63
78
92
105
119
132
26
.
145
158
171
190
Tabelul 5. Normele de densitate a fluxului termic a utilajului cu temperaturi pozitive la amplasarea la aer deschis i numrul de ore de lucru 5000 i mai puin
Trecerea condiionat a conductei,
mm
50
100
150
200
250
15
20
25
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
700
800
900
1000
1400
6
7
8
10
11
13
14
16
18
21
26
30
34
38
42
46
51
58
65
73
81
89
120
16
18
20
23
25
29
32
35
39
44
53
62
70
77
85
92
100
114
127
141
156
170
226
25
28
31
36
40
45
49
54
60
66
80
92
103
113
123
134
144
164
182
202
221
241
318
35
40
43
49
54
62
66
73
81
89
107
122
136
149
162
175
189
214
236
261
285
309
406
46
52
56
64
70
79
85
93
103
113
134
153
170
186
201
217
233
263
290
320
349
378
492
58
65
70
80
87
98
105
115
126
138
163
185
205
224
242
260
279
314
345
379
413
447
580
71
79
85
96
105
118
126
137
151
164
194
218
241
263
284
305
327
367
402
441
479
518
668
85
93
101
114
124
139
148
161
176
192
225
253
279
304
328
351
375
420
460
504
547
590
758
Mai mare de
Densitatea fluxului termic, Vt/m
1400 i supra26
46
63
78
92
105
119
132
fee plane
Not Semnificaiile intermediare a normelor de densitate a fluxlui termic trebuie s fie determinate prin interpolare.
450
500
550
600
99
109
118
132
144
161
171
186
203
221
258
290
319
347
373
398
426
476
520
568
616
663
850
114
126
136
152
165
184
195
212
231
251
292
327
359
391
419
448
478
533
582
635
687
739
943
130
143
154
172
187
208
221
239
261
282
328
366
402
436
467
498
532
592
645
703
760
816
1038
147
161
174
194
210
233
247
267
291
315
365
407
446
483
517
551
587
652
710
772
834
896
1136
145
158
171
190
6.
,
20
25
40
50
65
80
100
125
150
200
250
300
350
400
450
500
3
3
4
5
6
6
7
8
8
10
11
12
14
16
17
19
10
20
40
60
80
100
120
140
160
180
12
12
13
14
16
17
18
20
21
25
27
30
33
34
37
38
14
15
16
16
18
19
20
21
23
27
31
34
36
38
39
41
16
17
18
19
20
21
22
24
26
29
33
36
38
40
42
44
17
18
19
20
21
22
23
25
27
31
35
38
41
43
45
46
15
16
17
17
, /
3
4
5
5
6
6
7
8
9
10
12
13
15
16
18
21
4
5
5
6
7
8
9
9
10
12
14
16
18
2
21
23
6
6
7
8
9
10
11
12
13
16
18
20
22
23
26
27
7
8
9
10
11
12
13
14
15
18
20
22
24
26
28
30
9
9
10
11
13
14
15
16
17
20
23
25
27
29
31
33
10
11
12
13
14
15
17
18
19
23
26
28
30
32
34
36
500
, /2
11
12
12
13
13
14
15
Tabelul 6. Normele de densitate a fluxului termic pentru utilaj i conducte cu temperaturi nrgative cu amplasarea lor la aer deschis
Temperatura agentului termic,
20
25
40
50
65
80
100
125
150
200
250
300
350
400
450
500
3
3
4
5
6
6
7
8
8
10
11
12
14
16
17
19
minus 10
minus 20
minus 40
minus 60
minus 80
minus 100
minus 120
minus 140
minus 160
minus 180
12
12
13
14
16
17
18
20
21
25
27
30
33
34
37
38
14
15
16
16
18
19
20
21
23
27
31
34
36
38
39
41
16
17
18
19
20
21
22
24
26
29
33
36
38
40
42
44
17
18
19
20
21
22
23
25
27
31
35
38
41
43
45
46
15
16
17
17
3
4
5
5
6
6
7
8
9
10
12
13
15
16
18
21
4
5
5
6
7
8
9
9
10
12
14
16
18
2
21
23
6
6
7
8
9
10
11
12
13
16
18
20
22
23
26
27
7
8
9
10
11
12
13
14
15
18
20
22
24
26
28
30
9
9
10
11
13
14
15
16
17
20
23
25
27
29
31
33
10
11
12
13
14
15
17
18
19
23
26
28
30
32
34
36
Mai mare de
Densitatea fluxului termic, Vt/m
500 i supra11
12
12
13
13
14
15
fee plane
Not Semnificaiile intermediare a normelor de densitate a fluxlui termic trebuie s fie determinate prin interpolare.
7.
,
20
25
40
50
65
80
100
125
150
200
250
300
350
400
450
500
5
6
7
7
8
9
10
11
12
15
16
19
21
23
25
28
10
20
40
60
80
100
120
140
160
180
14
14
16
17
18
19
20
21
23
27
30
34
36
38
40
42
15
16
17
19
20
20
21
23
25
30
33
37
38
41
42
45
16
17
19
20
21
22
23
26
27
31
36
39
41
44
45
47
18
20
21
22
23
24
25
27
30
34
38
41
44
46
48
49
17
18
18
18
, /
6
7
7
8
9
9
10
11
13
16
17
20
22
24
27
29
6
7
8
9
9
10
11
12
13
16
19
21
23
26
28
30
7
8
9
10
11
12
13
14
16
19
20
23
26
28
30
33
9
10
11
12
13
13
14
16
17
21
23
26
29
30
33
35
10
11
12
13
14
15
16
18
20
23
26
29
32
34
35
37
12
12
13
14
16
17
18
20
21
25
27
31
34
36
37
40
500
, /2
15
16
16
16
16
16
17
Tabelul 7. Normele de densitate a fluxului termic a utilajului cu temperaturi negative la amplasarea n ncpere
Temperatura agentului termic,
20
25
40
50
65
80
100
125
150
200
250
300
350
400
450
500
5
6
7
7
8
9
10
11
12
15
16
19
21
23
25
28
minus 10
minus 20
minus 40
minus 60
minus 80
minus 100
minus 120
minus 140
minus 160
minus 180
14
14
16
17
18
19
20
21
23
27
30
34
36
38
40
42
15
16
17
19
20
20
21
23
25
30
33
37
38
41
42
45
16
17
19
20
21
22
23
26
27
31
36
39
41
44
45
47
18
20
21
22
23
24
25
27
30
34
38
41
44
46
48
49
17
18
18
18
6
7
7
8
9
9
10
11
13
16
17
20
22
24
27
29
6
7
8
9
9
10
11
12
13
16
19
21
23
26
28
30
7
8
9
10
11
12
13
14
16
19
20
23
26
28
30
33
9
10
11
12
13
13
14
16
17
21
23
26
29
30
33
35
10
11
12
13
14
15
16
18
20
23
26
29
32
34
35
37
12
12
13
14
16
17
18
20
21
25
27
31
34
36
37
40
Mai mare de
Densitatea fluxului termic, Vt/m
500 i supra15
16
16
16
16
16
17
fee plane
Not Semnificaiile intermediarea normelor de densitate a fluxlui termic trebuie s fie determinate prin interpolare.
8. 5000
(/),
,
65/50
90/50
110/50
, /
25
19
24
28
32
21
26
30
40
22
28
32
50
25
30
35
65
29
35
40
80
31
37
43
100
34
40
46
125
39
46
52
150
42
50
57
200
52
61
70
250
60
71
80
300
67
79
90
350
75
88
99
400
81
96
108
450
89
104
117
500
96
113
127
600
111
129
145
700
123
144
160
800
137
160
177
900
151
176
197
1000
166
192
212
1200
195
225
250
1400
221
256
283
.
1. 65/50, 90/50 110/50 95-70, 150-70 180-70 .
2.
65/50
25
19
24
28
32
21
26
30
40
22
28
32
50
25
30
35
65
29
35
40
80
31
37
43
100
34
40
46
125
39
46
52
150
42
50
57
200
52
61
70
250
60
71
80
300
67
79
90
350
75
88
99
400
81
96
108
450
89
104
117
500
96
113
127
600
111
129
145
700
123
144
160
800
137
160
177
900
151
176
197
1000
166
192
212
1200
195
225
250
1400
221
256
283
90/50
110/50
Note.
1. Temperaturile calculate medii pe an a apei n reelele termice de ap 65/50, 90/50 i 110/50 corespund diagramelor de temperatur 95-70, 150-70 i 180-70 .
2. Semnificaiile intermediale a normelor de densitate a fluxului termic trebuie s fie determinate prin interpolare .
9.
5000
,
(/),
65/50
90/50
110/50
, /
25
21
26
31
32
24
29
33
40
25
31
35
50
29
34
39
65
32
39
45
80
35
42
48
100
39
47
53
125
44
53
60
150
49
59
66
200
60
71
81
250
71
83
94
300
81
94
105
350
89
105
118
400
98
115
128
450
107
125
140
500
118
137
152
600
134
156
174
700
151
175
194
800
168
195
216
900
186
216
239
1000
203
234
261
1200
239
277
305
1400
273
316
349
- . 8
65/50
25
21
26
31
32
24
29
33
40
25
31
35
50
29
34
39
65
32
39
45
80
35
42
48
100
39
47
53
125
44
53
60
150
49
59
66
200
60
71
81
250
71
83
94
300
81
94
105
350
89
105
118
400
98
115
128
450
107
125
140
500
118
137
152
600
134
156
174
700
151
175
194
800
168
195
216
900
186
216
239
1000
203
234
261
1200
239
277
305
1400
273
316
349
90/50
110/50
10.
25
32
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
700
800
25
25
25
25
32
40
40
50
65
80
100
125
150
180
200
250
300
300
300
115
100
150
100
200
100
250
22
23
25
27
31
35
38
42
45
52
58
64
70
75
81
86
97
105
114
18
18
18
18
21
23
23
24
27
27
31
33
38
42
44
50
55
55
55
30
32
33
36
43
46
49
53
58
68
75
83
90
96
103
110
123
133
143
18
18
18
18
21
23
23
24
27
27
31
33
38
42
44
50
55
55
55
41
43
45
52
58
62
66
72
78
89
99
110
118
127
134
143
159
172
185
18
18
18
18
21
23
23
24
27
27
31
33
38
42
44
50
55
55
55
51
54
58
64
71
81
81
88
94
108
119
133
143
153
162
173
190
203
220
100
300
100
350
100
18
18
18
18
21
22
22
23
26
28
31
33
37
41
44
49
54
54
54
64
69
73
79
88
98
98
107
115
131
147
159
171
183
193
207
227
243
-
18
18
18
18
20
22
22
23
26
28
31
33
37
41
43
49
54
53
-
79
83
88
95
103
117
117
126
142
153
172
186
200
213
224
239
261
280
-
18
18
18
18
20
21
21
23
26
28
31
33
34
41
43
48
53
53
-
Tabelul 10. Normele de densitate a fluxului termic prin suprafaa de izolare a conductelor de aburi cu conducte de condens cu pozarea lor
comun n canale nevizitabile
Trecerea condiionat a conductelor, mm
25
32
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
700
800
25
25
25
25
32
40
40
50
65
80
100
125
150
180
200
250
300
300
300
Conduct
de aburi
Conduct
de condens
Conduct
de aburi
Conduct
de condens
Conduct
de aburi
Conduct
Conduct
Conduct
de conde conde aburi
dens
dens
Temperatura calculat a agentului termic
115
100
150
100
200
100
250
22
23
25
27
31
35
38
42
45
52
58
64
70
75
81
86
97
105
114
18
18
18
18
21
23
23
24
27
27
31
33
38
42
44
50
55
55
55
30
32
33
36
43
46
49
53
58
68
75
83
90
96
103
110
123
133
143
18
18
18
18
21
23
23
24
27
27
31
33
38
42
44
50
55
55
55
41
43
45
52
58
62
66
72
78
89
99
110
118
127
134
143
159
172
185
18
18
18
18
21
23
23
24
27
27
31
33
38
42
44
50
55
55
55
51
54
58
64
71
81
81
88
94
108
119
133
143
153
162
173
190
203
220
Not semnificaiile intermediare a normelor de densitate a fluxului termic trebuie s fie determinate prin interpolare.
Conduct
de aburi
Conduct
de condens
Conduct
de aburi
Conduct
de condens
100
300
100
350
100
18
18
18
18
21
22
22
23
26
28
31
33
37
41
44
49
54
54
54
64
69
73
79
88
98
98
107
115
131
147
159
171
183
193
207
227
243
-
18
18
18
18
20
22
22
23
26
28
31
33
37
41
43
49
54
53
-
79
83
88
95
103
117
117
126
142
153
172
186
200
213
224
239
261
280
-
18
18
18
18
20
21
21
23
26
28
31
33
34
41
43
48
53
53
-
11.
5000
,
(/),
65/50
90/50
110/50
, /
25
27
32
36
32
29
35
39
40
31
37
42
50
35
41
47
65
41
49
54
80
45
22
59
100
49
58
66
125
56
66
73
150
63
73
82
200
77
93
100
250
92
106
117
300
105
121
133
350
118
135
148
400
130
148
163
450
142
162
177
500
156
176
194
600
179
205
223
700
201
229
149
800
226
257
179
900
250
284
308
1000
275
312
338
1200
326
368
398
1400
376
425
461
. 8.
belul 11. Normele de densitate a fluxului termic pentru conducte cu dou evi a reelelor de
ap ncazul pozrii subterane fr canale cu durata anual de lucru mai mare de 5000 h
Trecerea condiionat a
conductei, mm
90/50
110/50
25
27
32
36
32
29
35
39
40
31
37
42
50
35
41
47
65
41
49
54
80
45
22
59
100
49
58
66
125
56
66
73
150
63
73
82
200
77
93
100
250
92
106
117
300
105
121
133
350
118
135
148
400
130
148
163
450
142
162
177
500
156
176
194
600
179
205
223
700
201
229
149
800
226
257
179
900
250
284
308
1000
275
312
338
1200
326
368
398
1400
376
425
461
12.
5000
,
(/),
65/50
90/50
110/50
, /
25
30
35
40
32
32
38
43
40
35
41
47
50
40
47
53
65
46
55
60
80
51
60
66
100
57
67
74
125
65
76
84
150
74
86
94
200
93
107
117
250
110
125
138
300
126
144
157
350
140
162
177
400
156
177
194
450
172
196
213
500
189
214
232
600
219
249
269
700
147
290
302
800
278
312
341
900
310
349
380
1000
341
391
414
1200
401
454
491
1400
467
523
567
. 8
belul 12. Normele de densitate a fluxului termic pentru conducte cu dou evi a reelelor de
ap n cazul pozrii subterane fr canale i durata anual de lucru de 5000 h i mai puin
Temperatura medie anual a agentului termic (de aducere/retur),
65/50
25
30
35
40
32
32
38
43
40
35
41
47
50
40
47
53
65
46
55
60
80
51
60
66
100
57
67
74
125
65
76
84
150
74
86
94
200
93
107
117
250
110
125
138
300
126
144
157
350
140
162
177
400
156
177
194
450
172
196
213
500
189
214
232
600
219
249
269
700
147
290
302
800
278
312
341
900
310
349
380
1000
341
391
414
1200
401
454
491
1400
467
523
567
90/50
110/50
(). ,
Anexa A (obligatoare) Lista actelor normative, la care se fac referin n text
NCM G.04.07-2006
MCH 4.02-02-2004
618-73
4640-93
9438-85
10296-79
10354-82
10923-93
17314-81
25100-95
25951-83
30732-2001
Reele termice
.
.
.
.
.
.
. .
.
.
.
().
18
25
32
45
57
76
89
108
133
159
219
273
325
377
426
476
530
630
720
820
920
1020
, , ,
19
20
19
20
150 .
151
80
120
140
140
150
160
180
180
200
220
230
240
240
260
280
300
320
320
320
320
320
320
80
120
140
140
150
160
170
180
200
220
230
230
240
240
250
250
260
280
280
300
300
320
80
100
120
120
140
160
180
180
180
200
200
220
240
260
280
300
320
320
320
320
320
320
80
100
100
100
120
140
160
160
160
160
180
180
200
200
220
220
220
240
240
240
260
260
50
60
80
80
90
90
100
100
100
120
120
120
120
120
140
140
140
140
140
140
140
140
60
80
100
100
120
140
140
160
160
180
200
200
200
200
220
220
220
220
220
220
220
220
.
1. , ,
.
, .
2. , ,
.
18
25
32
45
57
76
89
108
133
159
219
273
325
377
426
476
530
630
720
820
920
1020 i mai
mult
80
120
140
140
150
160
180
180
200
220
230
240
240
260
280
300
320
320
320
320
320
80
120
140
140
150
160
170
180
200
220
230
230
240
240
250
250
260
280
280
300
300
80
100
120
120
140
160
180
180
180
200
200
220
240
260
280
300
320
320
320
320
320
80
100
100
100
120
140
160
160
160
160
180
180
200
200
220
220
220
240
240
240
260
320
320
320
260
50
60
80
80
90
90
100
100
100
120
120
120
120
120
140
140
140
140
140
140
140
140
60
80
100
100
120
140
140
160
160
180
200
200
200
200
220
220
220
220
220
220
220
220
Note:
1. Pentru conducte, amplasate n canale, grosimea izolaiei este indicat pentru temperaturi pozitive a substanelor
transportate. Pentru conducte cu temperaturi sub zero a substanelor transportate grosimile limit trebuie de a fi acceptate aceleai, ca i la pozare n tuneluri.
2. n cazul, dac grosimea calculat a izolaiei este mai mare fa de cea limit, trebuie de acceptat materialul de termoizolare mai efectiv i de a se limita cu grosimea limit a izolaiei termice, dac aceasta se accept conform condiiilor procesului tehnologic.
.1.
:
1 K
d
d 2
(.1)
2 K
(.2)
1, 2 (
), ;
, ;
d , , ;
, .
, (.1) K
d
,
d 2
.
.2. . (d) .
.3
V Vi K c ,
(.3)
:
V - , 3;
Vi - , 3.
.1. Grosimea pieselor de termoizolaie din materiale de compactare, pn la instalarea pe suprafaa de izolaie, trebuie de a fi determinat lund n consideraie coeficientul de compactare dup
formula:
pentru suprafaa cilindric
1 K
d
d 2
(.1)
2 K
(.2)
und:
d
este mai mic de unitate, el trebuie s se
d 2
V Vi K c ,
(.3)
unde:
V - volumul materialului de termoizoie sau a piesei la compactare, m3;
Vi - volumul materialului de termoizoie sau a piesei n construcie lund n consideraie compactarea,
m3.
Ta .1
1,2
URSA
-11
-15, -17
, :
1,35-1,2
3,6 - 4,0*
2,6
-25
800
23 /3
50 60 kg/m3
800
3,0
1,5*
23 kg/m3
2,0
50 60 kg/m3
:
-45, 35, 25
-15
1,5*
:
35, 50
75
100
125
:
-30
-15, -17 -20
..75, 100, 150
1,51,8**
1,4
1,5
1,2
1,1
1,05
1,1
1,2
1,5
1,6
2,6
* - URSA M-11 p 40 .
-4,0, 50 -3,6.
** - URSA M-25 p 100 .
-1,8, 100 250 . 1,6, 250 - 1,5.
belul .1
Materiale de termoizolaie
i piese
Coeficientul de
compactare,
1,2
1,35-1,2
3,0
1,5*
2,0
1,5*
Materiale de termoizolaie
i piese
Coeficientul de
compactare,
3,6 - 4,0*
2,6
1,51,8**
1,4
1,5
1,2
1,1
1,05
1,1
1,2
1,5
1,6
2,6
* - coeficient de compactare a saltelelor URSA de marc M-11 pentru instalarea pe evi cu trecere condiionat pn la 40
mm inclusiv-4,0, pentru instalarea de la 50 mm i mai mult-3,6.
** - coeficient de compactare a saltelor URSA de marc M-25 pentru instalarea pe evi cu trecere convenional pn la
100 mm. inclusiv 1,8,mai mare de 100 pn la 250 mm inclusiv -1,6, mai mult de 250 mm 1,5.