Sunteți pe pagina 1din 29

S.C. Help Security S.R.L. Tel./Fax: 021/314.00.

08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

Licena de functionare nr. 1831 / T / 25.09.2009

PROIECTUL SISTEMULUI TEHNIC DE SECURITATE

BENEFICIAR: Pool-ul de Asigurare mpotriva Dezastrelor Naturale

Sediu social: Bucureti, Calea Victoriei, nr. 155, tronson 6, et. 6, bl. D1, sector 1; ROMANIA

SISTEM ANTIEFRACIE, TVCI I CA

COD PROIECT: 005.15

DATA : 05.03.2015

Nr. ex.: 1/2

NTOCMIT: ing.Nicolae Tudor

VERIFICAT: ing.Nicolae Tudor

APROBAT: ing.Nicolae Tudor

Proiectul conine 30 pagini si 7 plane desenate.

COD PROIECT: 004.15 1 CONFIDENTIAL


S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

CUPRINS

1. Generaliti pag. 3

2. Amplasamentul si mprejurimile obiectivului pag. 4

3. Elemente privind construcia pag. 4

4. Memoriu tehnic cu sistemele proiectate, rolul i funciunile acestora pag. 4

5. Structura sistemelor pag. 6

6. Descrierea zonelor protejate pag. 7

7. Specificarea locului de amplasare a echipamentelor pag. 8

8. Date tehnice de catalog pag. 9

9. Calcul energetic pag. 17

10. Jurnal de cabluri pag. 19

11. Garanii service pag. 21

12. Caietul de sarcini pag. 21

13. Condiii tehnice pag. 22

14. Msuri de securitate i sntate n munc pag. 24

15. Msuri de prevenire i stingere a incendiilor pag. 28

16. Alimentarea cu energie electric a sistemului pag. 29

17. ANEXE - Plane desenate 7 planse

COD PROIECT: 004.15 2 CONFIDENTIAL


S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

1. GENERALITI

1.1 Obiectul proiectului

Prezentul proiect a fost ntocmit de ctre SC Help Security SRL in baza contractului
ncheiat ntre Pool-ul de Asigurare mpotriva Dezastrelor Naturale i SC Help Security SRL
pentru proiectarea i execuia unui sistem de securitate la compartimentul Casierie, compus
din :
-sistem de alarmare la efractie ;
-sistem de supraveghereTVCI;
-sistem control acces

1.2 Domeniu de activitate

Pool-ul de Asigurare mpotriva Dezastrelor Naturale desfasoar activiti de asigurri.

1.3 Baza de proiectare:

Contract ncheiat ntre SC Help Security SRL i PAID - Pool-ul de Asigurare mpotriva
Dezastrelor Naturale.
Planurile de arhitectur ale obiectivului sunt executate de ctre proiectant.

1.4 Diverse

La elaborarea documentaiei s-au aplicat soluii moderne i s-au folosit materiale care s
conduc la un cost minim n condiii optime de performan i fiabilitate. S-au respectat
prevederile urmtoarelor reglementri tehnice n vigoare :
Legea 10 / 1995 privind calitatea in construc ii,
Regulamementul privind controlul de stat al calit ii n construc ii, aprobat prin HG nr 273
/ 1994,
I7 / 2002 Normativ privind proiectarea i executarea instala iilor cu tensiuni pn la
1000 V c.a.,
I20 / 2000 Normativ privind protecia construc iilor mpotriva trznetului,
I18/1-01-2002 Normativ pentru proiectarea si executarea instala iilor electrice interioare
de cureni slabi aferente cldirilor civile i de produc ie,
I18 /2-2002 Normativ pentru proiectarea i executarea instala iilor de semnalizare a
incendiilor i a sistemelor de alarmare contra efrac iei din cldiri,
CE 1 /1995 Normativ privind proiectarea cldirilor civile din punct de vedere al cerin ei
de siguran n exploatare,
PE 107 / 1995 Normativ privind proiectarea i execu ia lucrrilor cu cabluri electrice,
Norme generale de protecia muncii elaborate de catre Ministerul Muncii si Protec iei
Sociale 1996,
Legea Protectiei Muncii nr 319 / 2006,
S-au respectat: Legea nr 333 / 2003 privind paza obiectivelor, bunurilor, valorilor i
protecia persoanelor si H.G. nr 301 / 2012 privind NORMELE TEHNICE care trebuiesc
respectate cu ocazia proiectrii i instalrii sistemelor de alarmare la efrac ie.

COD PROIECT: 004.15 3 CONFIDENTIAL


S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

Standardul SR EN 50131-1 / 2009 (traducerea Standardului european EN 50131-1 /


2006) privind Sisteme de alarm
S-au avut n vedere planurile obiectivului pe baza cruia s-a stabilit configura ia
sistemului.

2. AMPLASAMENTUL I MPREJURIMILE OBIECTIVULUI

Sediul PAID - Pool-ul de Asigurare mpotriva Dezastrelor Naturale este situat n :


Calea Victoriei, nr. 155, tronson 6, et. 6, bl. D1, sector 1, Bucureti, Romania

Obiectivul se invecineaza :
- la Nord : Piaa Victoriei
- la Sud : Triumph Internaional i str. Sevastopol
- la Vest ; arpele Roz i Calea Victoriei
- la Est : str. Buzeti

3. ELEMENTE PRIVIND CONSTRUCIA

Tipul construciei : construcie veche.


Cldirea are perei exteriori din beton armat + tencuial cu grosimea de 28 cm.
Pereii interiori ai cldirii sunt din beton placai cu rigips, iar u ile de acces la etaj sunt din
termopan; ferestrele sunt din termopan.
nlimea ncperiilor este de 2,5 m.
Dimensiunile incperilor si destinaia acestora sunt prezentate n plan ele anexate,
plane ntocmite la o scar convenabil.

4. MEMORIU TEHNIC CU SISTEMELE PROIECTATE, ROLUL I FUNCIUNILE


ACESTORA

SISTEMUL TEHNIC DE SECURITATE este conceput pentru avertizarea personalului


propriu de conducere i a personalului de paz specializat n caz de efracie, sabotaj sau
agresiune i nregistrarea imaginilor video, necesare identificrii persoanelor participante la
infraciune.

4.1 Sistemul de detecie si avertizare la efrac ie

Sistemul realizeaz o supraveghere i comand unic asistat de o unitate central i


realizeaz alarmarea operativ (acustic, optic)
Sistemul este comandat de o central computerizat care prime te semnal, de la un
sistem de detecie i care comand o reea de semnalizare optic i sonor din zona de
alarm.

COD PROIECT: 004.15 4 CONFIDENTIAL


S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

Sistemul de detecie la efracie, este realizat cu:


detector de prezent;
contact magnetic ;
siren exterioar de efracie autonom cu acumulator ;
acumulatori 12V/7Ah
Structura sistemului antiefracie corespunde urmtoarelor cerin e :
are zon alocat separat n centrala de efrac ie pentru fiecare zon a
sediului ;
sunt partiionate compartimentele stabilite de factorii de decizie ai unit ii ;
tastaturile este de tipul cu LED-uri;
Sistemul de detecie la efraciei asigur protejarea cilor de acces n casierie, a
suprafeelor vitrate exterioare, asigurnd semnalarea strilor de pericol. Ua de acces la
arhiv (unde se afl centrala antiefracie) este prevzut cu contact magnetic.
Reeaua de cabluri este realizat cu cabluri din cupru, ecranat, n vederea eliminrii
alarmelor false i sunt pozate n canal de cablu PVC. Cablul va fi pozat pe trasee de curen i
slabi, iar coborrile se vor face n canal de cablu.
Orice secionare a cablului este semnalizat n panoul central de semnalizare datorit
liniei de sabotaj.
Senzorii vor fi conectai pe ieiri N.C. (normal nchis) i vor fi prevzu i cu rezisten e
de capt EOL conectate conform figurii de mai jos Pentru mrirea capacit ii de conectare
senzori, se vor dubla zonele de pe placa unit ii de control (ATZ)

4.2 Sistemul de televiziune cu circuit nchis TVCI

Sistemul de supraveghere cu camere video color, realizeaz supravegherea din


interiorul i de la intrarea imobilului.
Camerele video folosite, sunt de nalt rezolu ie i cu leduri n infraro u, fiind conectate
la un DVR (digital video recorder). Imaginile sunt nregistrate i pot fi redate apoi (dup
dat/or). Camerele de luat vederi dispun de compensarea automat a luminii, au obiectiv
varifocal pentru alegerea unei lrgimi i profunzimi adecvate a imaginii n func ie de zona
supravegheat, urmrindu-se ca din imaginile nregistrate s se poat realiza recunoasterea
persoanelor.
**Monitorul aparine beneficiarului cu o diagonala de minim 15 inchi pentru a vizualiza imagini
multiplexate. **
n cazul unei avarii la sistemul electric de 220Vca se va intercala un UPS care va
preveni pierderea eventualelor imagini.

COD PROIECT: 004.15 5 CONFIDENTIAL


S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

nregistrarea se face pe un hard disk recorder de capacitate 1TB care poate realiza
nregistrarea pe o perioada de minim 20 zile in conformitate cu HG 301/2012.
nregistratorul video digital (DVR) are urmtoarele posibilit i:
asigur nregistrarea imaginilor de pe fiecare camer;
dispune de facilitatea de copiere a unor imagini selectate;
calitatea imaginii permite recunoaterea persoanelor ;
sunt omologate pentru destinaia de sistem de supraveghere cu camere video.
Avantajul acestei variante este c se poate extinde n viitor ntr-un sistem integrat la
nivelul ntregii reele cu posibilitatea la cerere, sau n caz de alarm de a se lua imagini n timp
real de la orice sistem TVCI deja instalat.

4.3 Sistemul de control acces

Sistemul Control Acces, cuprinde urmtoarele echipamente: controler, tastatur, cititoare


de cartele de proximitate, butoane de ie ire, electromagnet blocare u sau yal de blocare
u. Sistemul de control acces este independent de sistemul de alarm, utiliznd un sistem de
acces cu 3 controlere ROSSLARE AC 115 cu tastatur i cititor de cartele de proximitate, un
electromagnet cu monitorizare u montat pe ua de acces in zona interioara a obiectivului.
AC 115 este un controler de acces cu tastatur care este i cititor Wiegand 26 bi i, ce
funcioneaz cu cartele de proximitate EM pe 125Khz. Controlerul suport pn la 2400 de
utilizatori. Accesul se poate face n mod: cartel sau PIN, cartel i PIN.

5. STRUCTURA SISTEMULUI DE SECURITATE

5.1 STRUCTURA SISTEMULUI DE ALARMARE LA EFRAC IE

Nr. Denumirea si tipul elementelor Nr. Avi


Tip Producator Furnizor
Crt (prescurtare echipament) buc
Centrala de alarmare la efracie, 5-32
SPECTRA
1 zone pe placa de baza - 2 partiii ,256 de 1 PARADOX EMPORIUM CE
SP6000
evenimente (CE)
2 Tastur LED 10 zone (T) RS K10V 2 PARADOX EMPORIUM CE
3 Acumulator ACC12 12V;12Ah 2 ULTACELL EMPORIUM CE
4 Contact magnetic (CM) DC 1561 1 PARADOX EMPORIUM CE
5 Detector de micare IR NV 500 23 PARADOX EMPORIUM CE
6 Siren stroboscopic de exterior (Sir.Ext) HCF6 1 PARADOX EMPORIUM CE
7 Acumulator ACC12 12V;5Ah 2 ULTACELL EMPORIUM CE

COD PROIECT: 004.15 6 CONFIDENTIAL


S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

5.2 STRUCTURA SISTEMULUI DE TELEVIZIUNE CU CIRCUIT NCHIS

Nr. Denumirea si tipul elementelor Nr. Avi


Tip Producator Furnizor
Crt (prescurtare echipament) buc
1 Digital videorecorder 8 canale (DVR) RS QS458 1 PENTAPLEX Q-SEE CE
Camera video color Dome
2 DCOM- 8020 UTC 8 Q-SEE CE
interior/exterior
3 HDD HDD SATA, 1TB 1 SEAGATE Q-SEE CE
4 Surs de alimentare 12V/2A, NSS kit 8 Q-SEE CE
5 Monitor 15 inch 1 Nespecificat Beneficiar CE
6 UPS 650 VA 1 Beneficiar CE

5.3 STRUCTURA SISTEMULUI DE CONTROL ACCES

Avize
d
e
Nr. Denumirea si tipul elementelor Nr.
Tip Producator Furnizor ca
Crt (prescurtare echipament) buc
lit
at
e
NADAL ELECTROSERVI
1 Yala electromagnetic (EM) REF1040GL 3 CE
BADAL CE
2 Buton cerere ieire PB-038B 3 ROSSLARE BNT CE
4 Central de control acces (CCA) AC-115 3 ROSSLARE BNT CE
5 Cititor de proximitate W26 AY KR12 6 ROSSLARE BNT CE
6 Acumulator 12V/7A ACC12 12V;7Ah 3 BNT CE
Transformator :16,5Vca / 3A cutie
7 TT45/16 3 BNT CE
metalica (SCA)

Obs.Butonul de cerere ieire urgen, se conecteaz direct la yala electromagnetic (EM)

6. DESCRIEREA ZONELOR PROTEJATE

6.1 DESCRIEREA ZONELOR PROTEJATE LA EFRAC IE

Nr. ELEMENT DE DETECIE ALOCAT


ZONA PROTEJAT
crt Denumirea ZONA PARTIIE

1 Intrare arhiv Contact magnetic (CM) Instantanee 1 P1


2 Hol acces Detectori de micare IR ntrziat 2 P1
3 Birou director Detectori de micare IR Instantanee 3 P1
4 Faad Detectori de micare IR Instantanee 4 P1
5 Zona st. spate Detectori de micare IR Instantanee 5 P1
6 Zona dr. spate Detectori de micare IR Instantanee 6 P1
7 Central efracie Tamper Central efracie Sabotaj 7 P1
8 Siren exterior Tamper Sabotaj 8 P1
COD PROIECT: 004.15 7 CONFIDENTIAL
S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

6.2 DESCRIEREA ZONELOR SUPRAVEGHEATE VIDEO

Nr. ZONA ELEMENT DE DETECIE ALOCAT Programare DVR


Zone SUPRAVEGHEAT Model Simbol Montare Mod Rezoluie
DCOM- 8020 UTC Detecie la micare 800 TVL
1 Intrare arhiv CV1 Perete
color
DCOM- 8020 UTC Perete Detecie la micare 800 TVL
2 Hol intrare CV2
color
Sacretariat DCOM- 8020 UTC Perete Detecie la micare 800 TVL
3 CV3
color
Hol secretariat DCOM- 8020 UTC Perete Detecie la micare 800 TVL
4 CV4
color
Hol intrare DCOM- 8020 UTC Perete Detecie la micare 800 TVL
5 CV5
color
Hol intrare DCOM- 8020 UTC Perete Detecie la micare 800 TVL
6 CV6
color
DCOM- 8020 UTC 800 TVL
7 Scri - lifturi CV7 Perete Detecie la micare
color
DCOM- 8020 UTC 800 TVL
8 Scri - lifturi CV8 Perete Detecie la micare
color

6.3DESCRIEREA ZONELOR DECONTROL ACCES

Nr. ZONA ELEMENT ALOCAT


Zone SUPRAVEGHEAT Model Simbol Montare
1 Camer IT REF1040GL EM U intrare
2 Hol intrare REF1040GL EM U intrare
3 Hol intrare REF1040GL EM U intrare

7. SPECIFICAREA LOCULUI DE AMPLASARE A ECHIPAMENTELOR

1. Centrala de efracie (CE) n interiorul arhivei, fixat pe perete.


2. Centralele de control acces (CCA) se amplaseaz deasupra u ilor de acces, fixate pe
perete i cititoarele la o nlime de 140-150 cm. (Observatie : Dac CCA este
monobloc-contine i Tastatura i Cititorul de proximitate atunci, se va monta la exterior,
lng ua de acces.)
3. Unitatea de nregistrare (DVR) si UPS-ul se amplaseaz ntr-o protec ie metalic (cutie
metalic) fixat rigid de perete, n camera IT.
4. Monitorul se va amplasa pe birou sau pe mobilierul din camera IT.
5. Sirena de exterior se va fixa pe peretele exterior al cldirii, la o naltime care s nu
permit distrugerea cf. Plan Anexa 5/7.
6. Tastaturile T1 ;i T2 (efracie) se amplaseaz la intrarea n sediu; c te una la fiecare u
de acces.
7. Pe pereii interiori, la ua camerei IT i la uile de acces n sediu, se monteaz
butoanele de cerere ieire.

COD PROIECT: 004.15 8 CONFIDENTIAL


S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

8. Camerele de supraveghere Dome (CV7) i (CV8) se vor monta pe hol cu viziune


direct asupra scrilor i a lifturilor.
9. Sursele de alimentare pentru camerele video se monteaz rigid n doze de legturi.

8. DATE TEHNICE DE CATALOG

A. PARADOX SPECTRA SP6000 - unitatea central

Caracteristici tehnice
suport modul de armare StayD
8x2 zone pe placa de baz utilizand dublarea de
zone ATZ
2 partiii
32 coduri de utilizator
1 cod de instalator
1 cod de mentenan
comunicator digital - raportare evenimente ctre un
dispecerat de monitorizare pe 3 numere de telefon
sau ctre proprietarul sistemului pe 5 numere de
telefon
memorie 256 evenimente
2 ieiri programabile PGM (100mA tip OC)
surs n comutaie de 1,1A
ieire 12Vcc/700mA pentru alimentare periferice limitat electronic la 1.1A (fuseless)
ieire 12Vcc/350mA pentru ncrcare acumulator back-up (4-7Ah/12V)
ieire 12Vcc/1A pentru comand siren limitat electronic la 3A (fuseless)
ieiri supervizate la defect sau sabotaj - siren, linie telefonic, surs 12V aux
suport upgrade local de firmware (cu interfa a 307USB i softurile WinLoad i
BabyWare v. 2.0)
compatibilitate cu softurile de programare WinLoad si BabyWare v. 2.0
dimensiuni plac de baz 19x8,9cm
temperatura de funcionare 0-50grdC

Expansibilitate
maxim 32 zone cablate (maxim 3 module de extensie zone cablate ZX8) sau wireless
(prin intermediul modulelor de extensie wireless RX1 sau RTX3)
maxim 15 tastaturi cablate (maxim 15 module cablate incluznd tastaturi, ZX8, RTX3
sau RX1)
maxim 8 tastaturi wireless K32RF si K37 (prin intermediul RTX3)
maxim 2 repetoare wireless RPT1 (prin intermediul RTX3)
maxim 4 sirene wireless SR150 (prin intermediul RTX3)
un modul cu sinteza vocala VDMP3
un modul IP100
un comunicator GSM PCS200
COD PROIECT: 004.15 9 CONFIDENTIAL
S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

Compatibilitate
tastaturi radio, telecomenzi bidirectionale, sirene de exterior radio si repetoare de
semnal (prin intermediul RTX3) - K32RF, K37, REM2, REM3, SR150, RPT1
telecomenzi unidirecionale (fr feedback), detectori radio de mi care, contacte
magnetice radio, ali detectori radio - REM1, REM15, PMD1P/PMD57/PMD85,
DCT2/DCT10/DCTXP2, GS250, SD738
module de comunicaie - comunicator GSM PCS200/PCS300, comunicator TCP/IP
IP100, comunicator vocal VDMP3, interfa de comunicatie cu PC-ul 307USB
module cablate - modul de extensie zone cablate ZX8, modul de extensie numar ie iri
programabile PGM4, modul izolator HUB2
alte module - modul memorie portabil PMC5
detectori - toat gama de detectori cabla i conven ionali PARADOX
software - programare WinLoad si BabyWare v. 2.0, monitorizare Android si
iPhone/iPod/iPad: iPARADOX (necesita IP100 versiune 5.10 sau mai noua)
Limitari
nu permite conectarea detectorilor de fum pe 2 fire

B. TASTATURA LED K10V


Tastatura LED, 10 zone, pe fir, verticala
suporta mod armare StayD
compatibil cu gamele SP, MG, E65
- partitii separate pentru armare/somn/veghe/inchis
- afisaj luminos pentru indicarea unei zone deschise
- 1 intrare de zona de la tastatura
- posibilitatea setarii independente a zonelor cu clopotel (chime)
- 7 butoane de actiune tip one-touch
- 3 alarme de panica activabile de la tastatura
- lumina ajustabila
- se conecteaza la BUS de comunicatie pe 4 fire

C. DETECTOR DE MICARE PARADOX NV 500


Procesare digital (FADEC)
Lentil cilindric/sferic Paradox 1
Acoperire: 10 x 10 m
Unghi de detecie: 90 grade si 0.5 m de la perete
4 profile pre-programate de procesare a semnalului:
Normal, Mediu, Imunitate la animale, Superior
Procesare single/dual edge (analiza intrare si iesire)
Procesare semnal dual digital auto puls (APSP) cu 2 nivele
de selectie
Compensare digitala cu temperatura (acelasi succes al detectiei, independent de
temperatura ambientului)
COD PROIECT: 004.15 10 CONFIDENTIAL
S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

Protectie la semnalele RF
Timp pornire: 10 secunde
Reglare digitala a sensibilitatii, in 5 trepte (50% - 150%)
LED pentru feedback (permite ajustarea sensibilitatii n functie de dimensiunea
camerei)
LED rosu indicator alarma - 3s
Comutator anti-sabotaj N.C.
Temperatura de functionare: de la -10 pana la +50 grade Celsius
Temperatura de operare: de la -10 pana la +50 grade Celsius
Nivel umiditate: 95% RH
Consum: 10.5mA@Standby / 11.3mA@Alarm
Dimensiuni: 9 x 5.5 x 4 cm
Imunitate la animale de companie: de pana la 16Kg

G. SIRENA STROBOSCOPIC AUTOALIMENTAT DE EXTERIOR HCF6A

Sirena stroboscopic de exterior HCF6A


are urmatoarele caracteristici:
1400mA 10-16Vdc
rata flash 120 per minut
single tone, 120db/1m@14V
posibilitate de back-up necesitand achizitionarea
unui acumulator de 12V/4.5Ah sau de 12V/5Ah. Este
prevazut cu flash pentru avertizare optic. Pentru
protecie carcasa este din policarbonat + metal.

Dimensiuni: 195x266x95 mm
- avertizare luminoasa si acustic n caz de efrac ie
sau sabotaj al sistemului.

H. NREGISTRATOR DIGITAL RS QS458

Descriere produs

- Inregistrare la rezolutie D1 de
704x576 cu 6 cadre/secunda/canal
- Interfa simpl i intuitiv
- Permite pn la 64 utilizatori n reea, din care 5 simultan
- Monitorizare live si nregistrri prin internet (PC i telefon mobil)
- Compresie H.264
- Suport Dual Stream (CIF si D1)AVC793C(D), a new released Full D1 4CH H.264 DVR,

COD PROIECT: 004.15 11 CONFIDENTIAL


S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

features in its graphical OSD display with USB mouse control, AVTECH's exclusive DCCS
(DVR / Camera Communication System) technology, and advanced motion surveillance.

Opiuni mod LIVE:


- Setri imagine pentru fiecare camer n parte
- Zoom digital x2
- Control camere PTZ (Speed Dome-uri)
- Poate afia toate canalele simultan
- Afiare prin rotaie a fiecrui canal video

Opiuni mod NREGISTRARE:


- Permite inregistrare continuua, dupa un orar modificabil (pe ore sau chiar pe zile), la miscare
(cu reglarea sensibilitatii si eliminarea anumitor zone)
- Afiseaza inregistrarile pe 1, 4 sau 8 canale simultan
- Posibilitate zoom digital x2
- Posibilitate inregistrare cu audio
- Viteza derulare in fata pana la x16
- Derulare cu incetinitorul x1/2, x1/4, x1/8

Opiuni INTERNET:
- DVR-ul poate fi accesat prin browser-ul Internet Explorer
- Control PTZ prin Internet Explorer
- Afiare inregistrare pe toate canalele simultan
- Viteza derulare n fa pn la x16
- Derulare cu ncetinitorul x1/2, x1/4, x1/8
- Posibilitate afiare list evenimente
- Majoritatea setrilor care se pot face local in DVR, se pot face i de la distan , direct din
browser.

Opiuni TELEFON MOBIL:


- DVR-ul poate fi accesat de pe iPhone/iPad, BlackBerry, PDA si de pe orice dispozitiv cu
sistem de operare Android, Symbian sau Windows Mobile
- Putei vizualiza pn la 8 camere simultan
- Permite vizualizarea LIVE, a nregistrrilor, controlul PTZ

Alte FUNCII:
- Detecie obturare camer (alarma audio, marire imagine, trimitere email, notificare
dispecerat)
- Detecie pierdere semnal video (alarm audio, mrire imagine, )
- Permite pana la 64 utilizatori n reea, din care 10 simultan
- Administratorul are posibilitatea de a gestiona logurile on-line
- Are sunet bidirectional
- Afiare camere prin rotaie - Are sunet bidirectional
- Afiare camere prin rotaie

SPECIFICAII TEHINCE:
COD PROIECT: 004.15 12 CONFIDENTIAL
S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

SISTEM OPERARE
Sistem operare: Linux
VIDEO
Intrari video: 8 x BNC (1.0 Vp-p, 75)
Iesiri video: 1 x BNC, 1 x VGA
AUDIO
Intrari audio: 1 x RCA
Iesiri audio: 1 x RCA
AFISARE IMAGINI LIVE
Local pe monitor: 1 - 8 camere simultan
Prin internet: 1 - 8 camere simultan
Rezolutie afisare: D1: 704x576 pixeli
25 cadre/secund/canal la rezolutie D1
Viteza afisare:
200 cadre/secund/toate canalele la rezolutie D1
INREGISTRARE
Compresie video: H.264
D1: 704x576 pixeli
Rezoluie nregistrare:
CIF: 352x288 pixeli
D1 (6.25 cadre/secunda/canal)
Viteza de nregistrare:
CIF (25.00 cadre/secunda/canal)
Tip nregistrare: Manual / Dupa orar / La alarma / La detectie miscare
AFIARE NREGISTRRI
Local pe monitor: 1 - 8 camere simultan
Prin internet: 1 - 8 camere simultan
Dual Stream: Da
MEMORIE INTERNA
Hard Disk-uri interne: 1 x 2000 GB S-ATA
slot SD-card

Intrari alarma: Nu
Iesiri alarma: Nu
RS485: Da
USB: 2 x USB
REEA (INTERNET)
Internet: Muf RJ45 (doar prin cablu)
ALTELE
Back-up: Da (Stick USB, Hard Disk extern, etc.)
Telecomand: Da
Mouse: Da. 1 x USB
Dimensiuni: - mm (L x l x h)
Alimentare: Sursa de alimentare inclusa in pachet

I. CAMERA DOME DCOM- 8020 UTC

DESCRIERE

COD PROIECT: 004.15 13 CONFIDENTIAL


S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

Camera model DCOM-8020 este o camera de nalt rezolu ie


800 TVL, care poate fi montat att la exterior ct i la interior,
Rezisten la intemperii,
tip dome care va permite montarea camerei pe perete, tavan sau alta suprafata plan.
Camera are 24 de leduri de IR cu ajutoarul crora pute i vedea pe timp de noapte pe
distane de pn la 20m.

Rezoluie 800 linii TV


Lentila Fixa 3.6mm; 1/3 HDIS CMOS
Cu infrarou 20 metri; 24 LED-uri
Funcii speciale BLC, AGC, AWB
Raport zgomot > 45 dB
Grad de protecie IP65
AGC: Auto
Obturator electronic: PAL: 1/50s~1/100,000s;
Iesire video: Semnal compozit (1.0Vp-p, 75);
Dimensiuni 94 mm x 69 mm
Temperatur -20 ~ +50 C
Consum (A): DC12V(+/-10%), 550mA;
Garanie 24 luni

SPECIFICAII TEHNICE

Protecie
Exterior Exterior
Rezoluie
PAL: 976 (H) x 496 (V); 800 linii TV
Format
Dome Dome
Infrarou
Cu infrarou Infrarou ntre 1 - 20 m
Lentila
Fix Fix - 3.6mm

J. CONTROLER ROSSLARE CU TASTATURA STAND-ALONE AC-115

Fiecare AC-115 suport o singur u cu putere si control pentru 2 cititori (IN / OUT), o
grev de blocare 1.2A, monitor u i intrare REX, i are o ncrctor baterie de rezerv
ncorporat. Cu software-ul de PC-uri asociate (AS-115), sistemul func ioneaz perfect n
modurile online i offline. Un eveniment off-2000 FIFO (First In First Out) jurnal istorie este
stocat n memorie non-volatil, care poate fi ncrcat la PC. 8-controlere pot fi conectate ntr-o
reea de ncredere i dovedit RS-485, care interfe ele cu software-ul PC folosind pe RS-232
Convertor RS-485.
Caracteristici unice includ solide clopot intern care s permit usa, clopote, i sun alarma.
COD PROIECT: 004.15 14 CONFIDENTIAL
S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

CARACTERISTICI PRINCIPALE
2400 utilizatori
2000 Istoria Eveniment
Rapid i uor de instalat, All-in-One
8 zone de timp de acces programabile
24 zile de vacan programabile
Trei moduri de operare: normal, bypass i Secure
Suporta doua cititoare Wiegand standard de 26-bi i
(PIN numai, PIN + PROX, sau PROX)
Sursa de alimentare intern pentru cititori, de blocare i
intrri, cu un ncrctor de baterie de rezerv extern
Ceas n timp real cu baterie de back-up dureaz pn
la 10 ani
Funcia de detectare a sabotaj pentru cititori i acopere
detectare sabotaj pentru unitatea principal cut-cablu
Bell, clopote i alarm annunciator cu tonuri audibile
Releu auxiliar
3 moduri de securitate selectabile i 3 nivele de
utilizator programabile
O interfa simpl i intuitiv PC uor de utilizat reduce complexitatea gestionrii control
acces Pentru Microsoft Windows 98 / Me, XP i / NT / 2000/7
AC-115 poate funciona ca un controler PIN singur u independent i nu are nevoie de
PC
Raz lung RS-485 se conecteaz la reea PC-ul folosind un convertor MD-14 RS-232 la
RS-485 (una pe reea)
Drepturile de acces programabile software pentru PC
Permite gestionarea datelor de utilizator, fotografie cu cmpuri personalizate, drepturi de
acces, alarme, timp grev, i modul usa de la o loca ie central de pn la 8 usi re ea
Produce rapoarte de la datele obinute, cum ar fi de ori de intrare i ie ire, precum i n
funcie de tipul de alarm cu filtre pentru utilizatorii, localizare, i timp

Fisa Tehnica

Denumire produs Q2008-C2


Funcie Central de control acces standalone 1 u
Capacitate utilizatori 2400
Mediu utilizare / temperatura Interior, -10 ~ +50C
Tehnologie acces cartela i/sau cod PIN
Tehnologie cartela EM 125 KHz (TK4100)
Iesire comanda releu cu NO / NC
Alte porturi intrare buton iesire, intrare senzor magnetic usa
Material carcasa plastic, ALB
Tensiune alimetare 16.5 Vca
COD PROIECT: 004.15 15 CONFIDENTIAL
S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

Curent de intrare Standby: 65mA; Maximum: 120mA


Dimensiuni 134x85x30 mm
Certificari CE, ROHS, FCC, Certificat Conformitate
Importator in Romania SECPRAL srl

K. YAL ELECTROMAGNETIC REF1040GL


Yala electromagnetica ingropata,
Memorie mecanica,
"Fail secure",
Varianta lunga,
Consum 1A,
Alimentare 12 V Ac/Dc

L. BUTON EXIT PB-038B

Buton cerere iesire


Carcasa metalica
Varianta aparenta

9. CALCULUL ENERGETIC

9.1 CALCULUL ENERGETIC AL SISTEMULUI DE ALARMARE LA EFRACTIE

Consum/buc. Consum total


Nr. Nr.
Echipament
crt. buc. Veghe Alarma Veghe Alarma
(mA) (mA) (mA) (mA)
1 Centrala antiefracie SPECTRA SP6000 1 50 150 50 150
2 Tastatura RS K10V 2 50 80 100 160
COD PROIECT: 004.15 16 CONFIDENTIAL
S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

3 Detector PIR NV 500 23 10,5 11,3 241,5 259,9


7 Siren de exterior (Sir.Ext) CROW BS 1 10 1400 10 0
TOTAL CONSUM (mA) 401,5 569,9

Capacitatea minim necesar a acumulatorului este:

C.acc=1,25x(23,5hxI.veghe+0,5hxI.alarm)=1,25x(23,5 x 401,5 + 0,5 x 561,8)= 11,85Ah

Prin acumulatorul de 12Ah/12V amplasat n cutia centralei de efracie ndeplinete


condiia de funcionare a sistemului la cderea tensiunii principale de 220V, de minim 24 ore n
stare de veghe din care 0,5 ore n stare de alarm.
Sirena de exterior n stare de alarm are un consum de 1400mA pe care l absoarbe exclusiv
din acumulatorul propriu de 12V/5Ah.

T.alarma(h) = I.acumulator / 1,25xI.sirena = 5/ 1,25x1,4= 2,85 ore, fiind ndeplinit condiia


de funcionare a sirenei de exterior n stare de alarm de minim 30 minute.

Obs. Nu s-au luat in calcul componentele pasive (contactul magnetic).

9.2 CALCULUL ENERGETIC AL SISTEMULUI DE TELEVIZIUNE CU CIRCUIT NCHIS

Nr. Echipament Nr. buc. Consum/buc. (W) Consum total (W)

1 nregistrator digital DVR RS QS458 1 30W 30W


2 Camera video DCOM 8020 UTC 8 12V X 0,6 = 7,2W 57,6W
3 Monitor LCD 15 inch 1 40W 40W
TOTAL 127,6W

COD PROIECT: 004.15 17 CONFIDENTIAL


S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

UPS-urile (Uninterruptible Power Supply) sunt surse nentreruptibile de putere folosite


pentru protecia aparatelor electrice la variaii de tensiune precum i pentru asigurarea
autonomiei energetice in cazul ntreruperilor de curent pentru o anumit perioad de timp.
Puterea UPS-urilor se exprim n VA (volt-amperi) i arat puterea total a consumatorilor
ce pot fi alimentai din UPS. Diferena dintre VA i W (watt) rezult din factorul de putere
(cos ) al UPS-ului.
Pentru sursa UPS folosita de 650VA factorul de putere este cos =0,6, rezultnd puterea
maxim pe care o poate debita sursa de : P=650VA X 0,6=390W.
Timpul de back-up al sursei UPS este datde energia magazinat n acumulatorul sursei.
Sursa UPS de 650VA are incorporat un acumulator plumb-acid de 12V/7Ah, rezultnd o
energie electric pe care o poate debita acumulatorul ntr-o or de:

(1) Ea = 0,8 x U x Ca = 0,8 x 12V x 7 Ah = 67,2 Wh, unde:

- O,8 este coeficientul de descrcare al acumulatorului pn la care poate funciona


sursa UPS (acest coeficient scade n timp prin uzura acumulatorului) ;
- U este tensiunea acumulatorului ;
- Ca este capacitatea acumulatorului.

Energia consumat ntr-o or de sistemul TVCI este de :

(2) Ec = Pt xT = 127,6W x 1h = 127,6W

Din rezultatele de la (1) i (2) rezult timpul de back-up al sistemului TVCI la cderea
energiei electrice principale de :

T(h) = Ea / Ec = 67,2 / 127,6= 0,5h = 0,52 X 60min = 31 min

n cazul disparitiei tensiunii de 220 Vc.a. sistemul TVCI va mai funciona aproximativ 30
de minute, fiind ndeplinit condiia ca sistemul TVCI s ramn activ minim 15
minute.

9.3 CALCULUL ENERGETIC AL SISTEMULUI DE CONTROL ACCES

ncrcarea instalaiei se calculeaz pe baza consumului electromagnetului


sau a yalei electromagnetice n regim de acionare.

Echipament Nr. buc. Consum Consum Total Total consum


veghe- alarma mAh consum alarma
mAh (1 buc.) veghe (mAh)
(1 buc.) (mAh)
Tastatura stand alone +Cititor cartele 3 208 208 624 624

Yal electromagnetic 3 10 1000 30 3000


Total consum / ora 654 3624

COD PROIECT: 004.15 18 CONFIDENTIAL


S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

ntruct acumulatorii tampon trebuie sa asigure func ionarea sistemului timp de 24 ore
n regim de functionare normal:

Total consum = 1.25 x (Total veghe x 23,5 + Total alarma x 0.5)

Astfel, n cazul sistemului nostru vom avea :


Total consum = 1,25 x (23,5 x 0,654 + 0,5 x 3,624 = 1,25 x (14,669 + 1,812) =
= 1,25 x 16,481Ah=20,60 Ah
Pentru a suplini consumul sistemului de control acces de la sistemul antiefractie,
aceasta va fi alimentat cu 3 acumulatori de 7Ah (sau 2 acumulatori de 12 Ah).

10. JURNALUL DE CABLURI

10.1 JURNALUL DE CABLURI AL SISTEMULUI DE ALARMARE LA EFRACTIE

Nr. Simbol Tip cablu Conexiune Observatii


crt. cablu de la -------------------------- pana la
1 A01 MyyM 3x1,5 Tablou Electric CE

2 E01 Cablu efracie CE Tastatura T1


6x0,22+E
3 E02 Cablu efracie CE Tastatura T2
6x0,22+E
4 E03 Cablu efracie CE CM1
6x0,22+E
5 E04 Cablu efracie CE Det.PIR 15; 16; 19;
6x0,22+E 20
6 E05 Cablu efracie CE Det.PIR 14; 17; 18;
6x0,22+E 21; 22
7 E06 Cablu efracie CE Det.PIR 8; 9; 10; 11;
6x0,22+E 12; 13; 23
8 E07 Cablu efracie CE Det.PIR 1; 2; 3; 4; 5;
6x0,22+E 6; 7
9 E11 Cablu efracie CE Sirena Exterior
6x0,22+E
10 E12 MyyM 2x0,75 CE Tamper Sir.Ext.

10.2JURNALUL DE CABLURI AL SISTEMULUI DE TELEVIZIUNE CU CIRCUIT


INCHIS

COD PROIECT: 004.15 19 CONFIDENTIAL


S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

Nr. Simbol Tip cablu Conexiune Observatii


crt. cablu de la -------------------------- pana la
1 A01 MyyM 3x1,5 Tablou Electric UPS
2 A02 Dotare DVR UPS DVR sau (MyyM
3x1,5)
3 A03 Dotare Monitor Tablou Electric Monitor idem
4 A04 Dotare SA UPS SACV1 idem
5 A04 Dotare SA UPS SACV2 idem
6 B01 MyyM 2x0,75 SACV1 CV1
7 B02 MyyM 2x0,75 SACV1 CV2
8 B03 MyyM 2x0.75 SACV1 CV3
9 B04 MyyM 2x0.75 SACV1 CV4
10 B05 MyyM 2x0.75 SACV1 CV5
11 B06 MyyM 2x0.75 SACV2 CV6
12 B07 MyyM 2x0.75 SACV2 CV7
13 B08 MyyM 2x0.75 SACV2 CV8
14 C01 Cablu UTP cat.5e Imput 1 video DVR Output video CV1
15 C02 Cablu UTP cat.5e Imput 2 video DVR Output video CV2
16 C03 Cablu UTP cat.5e Imput 3 video DVR Output video CV3
17 C04 Cablu UTP cat.5e Imput 4 video DVR Output video CV4
18 C05 Cablu UTP cat.5e Imput 5 video DVR Output video CV5
19 C06 Cablu UTP cat.5e Imput 6 video DVR Output video CV6
20 C07 Cablu UTP cat.5e Imput 7 video DVR Output video CV7
21 C08 Cablu UTP cat.5e Imput 8 video DVR Output video CV8

10.3 JURNALUL DE CABLURI AL SISTEMULUI DE CONTROL ACCES

Nr. Simbol Tip cablu Conexiune Observatii


crt. cablu de la -------------------------- pana la
1 A1 MyyM 2x0,75 Tablou Electric SCA1
2 A2 MyyM 2x0,75 Tablou Electric SCA2
3 A3 MyyM 2x0,75 Tablou Electric SCA3
4 B1 MyyM 2x0,75 SCA1 CCA1
5 B2 MyyM 2x0,75 SCA2 CCA2
6 B3 MyyM 2x0,75 SCA3 CCA3

COD PROIECT: 004.15 20 CONFIDENTIAL


S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

Nr. Simbol Tip cablu Conexiune Observatii


crt. cablu de la -------------------------- pana la
7 C1 Cablu efracie CCA1 Cititor cartele
6x0,22+E (IN/OUT)
8 C2 Cablu efracie CCA2 Cititor cartele
6x0,22+E (IN/OUT)
9 C3 Cablu efracie CCA3 Cititor cartele
6x0,22+E (IN/OUT)
10 C4 Cablu efracie CCA1 Buton cerere ieire 1
6x0,22+E
11 C5 Cablu efracie CCA2 Buton cerere ieire 2
6x0,22+E
12 C6 Cablu efracie CCA3 Buton cerere ieire 3
6x0,22+E

11. GARANTII SERVICE

Firma SC Help Security SRL asigura garan ie de functionare a sistemului de 12 luni de


la data punerii n funciune.
Sistemul de alarm trebuie periodic verificat i ntre inut de personalul specializat al
firmei instalatoare, sau dupa caz de o firm care asigur service-ul.
Se va forma prin instruire de ctre executant o echip de speciali ti care s preia
sistemul pentru verificare i ntreinere n exploatare i se va ncheia un contract de
service cu o firm licentiat pentru asemenea lucrri, conform legislatiei n vigoare.
Contractul va prevede ca durata de interven ie la deranjamente s fie de maxim 24 ore
de la primirea sesizrii.

12. CAIETUL DE SARCINI

1. Se vor respecta instruciunile date de fabricant pentru atingerea performan elor optime.
2. Centrala de alarm s fie amplasat ntr-un loc mai pu in frecventat de angaja ii unit ii,
inaccesibil persoanelor strine, fixat la nl ime mare (eventual mascat n plafoane
false), reducnd astfel posibilitatea anihilrii acesteia.
3. Zona de amplasare a centralei este supravegheat prin detector de prezent, declarat pe
zona instantanee.
4. Tastatura va fi amplasat la distan fa de central i ct mai aproape posibil de zona
intrrii, pentru reducerea timpului de temporizare declarat zonei de intrare, durat care nu
va depi 10 secunde.
5. Detectoarele de prezen trebuie montate astfel nct s supravegheze n totalitate cile
posibile de intrare din exterior n spatiul protejat. Nu se vor monta n spa ii care pot fi
obturate (de exemplu spaiul de nchidere al unei u i).
6. Fixarea centralelor i a sirenei se va realiza prin 4 puncte i pe o adncime de 50 mm,
folosindu-se dibluri metalice sigure sau se vor realiza supor i metalici bine prinsi pe zid.

COD PROIECT: 004.15 21 CONFIDENTIAL


S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

7. Detectoarele de prezen trebuie sa fie fixate astfel nct s nu mai fie posibil deplasarea
ulterioar a detectorului fr demontarea detectorului.
8. Toate cablurile n afara celor care sunt trase pe trasee de patcabluri existente sau pe alte
elemente de sustinere vor fi trase prin teava PVC sau/si tub flexibil din PVC (tip copex) i
vor fi pozate pe tavan sau pe pereti pn la zonele de conexiuni ale camerelor video.
9. Se interzice instalarea n acelai canalet de protectie a cablurilor de energie i a cablurilor
TVCI. De asemenea se interzice folosirea unor doze sau cutii de conexiuni comune pentru
cablurile de energie si cele pentru TVCI.
10. Fixarea cablului este obligatorie la capete si la fiecare schimbare de directie.
11. La alegerea traseului unui cablu se vor avea in vedere urmatoarele:
i. - lungimea cablului sa fie minim;
ii. - lungimea spturilor i a spargerilor s fie minime.
12. Cablurile nu se secioneaz. Se admit secionri de cabluri numai pentru realizarea
conexiunilor.
13. Cablurile sunt prevzute cu etichete. Pe etichete se va inscriptiona marca cablului.
Etichetele sunt obligatorii la capetele cablului i pe traseu la fiecare schimbare de direc ie.
14. Se va evita instalarea circuitelor i cablurilor n lungul conductelor calde, interzicndu-se
instalarea pe suprafee calde.
15. Se vor evita traseele expuse la umezeal.
16. Pe poriunile reduse ale traseelor apropiate de suprafe e calde sau la ncruci ri cu
acestea, distana minim ntre circuite i elementele calde trebuie sa fie de 12 cm, sau se
vor lua masuri de izolare termic.
17. Distana ntre cablurile coaxiale TVCI i cele electrice cu frecven a de 50 Hz. i tensiuni
pn la 1000V, att n montaj ngropat ct i n montaj aparent, trebuie s fie de minim 25
cm, cu condiia ca izolaia s fie corespunztoare i s nu existe inndiri la conductoarele
electrice pe poriunea de paralelism.
18. Cablurile se pozeaz / se trag cu atenie astfel nct s nu fie dep it for a de tensionare
permis de producator i precizat n foaia de catalog.

13. CONDIII TEHNICE

13.1 Condiii pentru executant

Prezentele condiii tehnice sunt minime i obligatorii ce trebuie ndeplinite de executant.


Echipamentele sistemelor tehnice de securitate cu certificatele de conformitate din
Uniunea European sunt achizitionate de executant cu exepia monitorului video de 15 i a
sursei UPS de 650VA care sunt achiziionate de beneficiar.
Executantul va prevedea toate materialele i for a de munc necesar pentru montare i
punere n funciune a lucrrilor, aa cum rezult din documenta ia tehnic a proiectului i
necesitile lucrrii.
Executantul va respecta toate normativele de specialitate, prescrip iile tehnice i normele
specifice acestor categorii de lucrri.
Lucrrile executate vor fi de cea mai bun calitate astfel nct instala ia men ionat s
asigure performanele unei bune funcionri i ntre inere usoar.
n cazul constatrii unor neconcordane se va anun a proiectantul prin grija beneficiarului
spre a se analiza situaia i a se lua msurile corespunzatoare.

COD PROIECT: 004.15 22 CONFIDENTIAL


S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

Proiectantul va fi solicitat la nevoie s asigure asisten a tehnic la montaj i n mod


obligatoriu va participa la predarea frontului de lucru i la predarea beneficiarului a
lucrrilor executate.
Toate materialele folosite vor avea certificate de confirmare a calit ii lor, inclusiv din
punct de vedere al securitii muncii.
Folosirea de echipamente, aparate, dispozitive, etc. se va face numai pe baza
agrementului tehnic i a avizelor eliberate de organele abilitate conform prevederilor
legale.

13.2. Condiii de montaj

La predarea frontului de lucru de beneficiar i proiectant ctre executant se vor consemna


urmtoarele:
traseele de cabluri vor corespunde proiectului i vor fi stabilite definitiv de proiectant
mpreun cu executantul lucrrii;
poziia strpungerilor i a punctelor de racordare;
poziia de montaj pentru toate echipamentele instalate.
La montaj nu se admit secionri pe traseele de cablu dect pentru efectuarea
conexiunilor.
n timpul execuiei se vor ntocmi desene cu instala iile real executate, atasnd i toate
dispoziiile de antier prin care s-au dat derogri pentru modificarea traseelor sau
soluiilor din proiect. Aceste desene se vor preda dirigintelui de santier.

13.3 Reglementri pentru proiectare

-Normativ pentru proiectarea si execuia instala iilor de telecomunica ii i semnalizare


(incendiu) din cldiri civile i de productie -Indicativ I 18/2002.
-Normativ I 7/2002 pentru proiectarea i executarea instala iilor electrice cu tensiuni
pn la 1000 V.
-Norme privind noiuni generale, structura i concep ia unui sistem tehnic de alarm
contra efraciei IGP-DPO/ 1995.

13.4 Condiii pentru beneficiar

Documentaia urmeaz a fi avizat prin grija beneficiarului de ctre D.G.P.M.B.


Serviciul de Ordine Public pentru sistemul de securitate;
Prin grija beneficiarului se vor lua msuri de supraveghere permanent a sistemului;
La beneficiar se vor realiza toate lucrrile aferente instalrii i punerii n func iune a
sistemului astfel :
S se respecte normele de securitate i sntate a muncii prezentate n proiect i
legislaia n vigoare;
S se respecte normele i msurile de prevenire i stingere a incendiilor prezentate n
proiect i legislaia n vigoare;

COD PROIECT: 004.15 23 CONFIDENTIAL


S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

S se prevad mijloace de prim ajutor eficace;


S se aplice cerinele art. 209 NGPM/1996;
S se ntocmeasc proceduri de intervenie pentru cazuri de criz sau dezastre;
S nu se permit accesul persoanelor neautorizate la instala iile electrice;
S se verifice dac instalaia de legare la pmnt este corespunztoare, s fac
msurtori periodice a rezistenei prizei de legare la pmnt i s ob in buletinele de
msurtori care s ateste c priza de pmnt este n parametri normali, conform
legislaiei.

14. MSURI DE SECURITATE I SNTATE N MUNC

14.1 Factorii de risc la execuia lucrrii

Factorii de risc avui n vedere la elaborarea documenta iei sunt urmtorii:


cdere obiecte de la nlime
curent electric : atingere indirect i direct
lucru la nlime
proiectare de corpuri sau particule
deplasri pe suprafaa nclinat sau alunecoas
lucru in spaii nguste
contact cu corpuri ascuite
Proiectantul a avut n vedere aceti factori de risc care apar la ndeplinirea sarcinilor de
munc.
Beneficiarul este obligat s refac aceast analiz cu datele concrete, conform Legii
319/2006 Cap. III, s identifice complet toate riscurile i s ia toate msurile pentru
diminuarea sau evitarea lor.
Contractul de execuie cuprinde i clauze privind securitatea i sntatea muncii cu
rspunderile prilor.

14.2 Msurile individuale i colective de securitatea i sntatea muncii la


execuia lucrrii

Fa de factorii de risc estimai pentru execuia lucrrii, indica i mai sus, se impun
urmtoarele sortimente de mijloace individuale de protec ia muncii care pot fi acordate
conform HG 1048/2006:
casc de protecie rezistent la foc i penetra ie
mnui de protecie electroizolante JT
nclminte de protecie electroizolant JT
covor electroizolant
mnusi de protecie rezistente la uzur
centura de siguran pentru lucru la nlime sau platforma de lucru la nl ime
ochelari de protecie la praf
masc de protecie la praf

COD PROIECT: 004.15 24 CONFIDENTIAL


S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

salopet de protecie
Personalul de execuie va utiliza numai utilaje sigure dpdv al securit ii i snt ii muncii,
care au certificate de conformitate i sunt cumprate cu declara ie de conformitate dpdv al
securitii muncii i sunt marcate de conformitate de securitate. Sculele utilizate vor avea
mnere electroizolante, ele vor fi apucate numai de zona izolat, se vor folosi numai scri
electroizolante iar personalul trebuie s fie dotat i s utilizeze echipamentul individual de
protecie, respectnd principiul cel puin dou mijloace electroizolante nseriate pe cale de
curent.
Echipamentele portabile i uneltele manuale utilizate vor respecta cap. II din HG
1146/2006
Executantul va utiliza pentru manevre n instala iile electrice de joas tensiune numai
personal autorizat conform HG 1146/2006, Anexa 1, pct. 3.3.25.
Ca mijloace colective de protecie se recomand : semnalizarea locurilor periculoase i
atenionare vizibil a lor cu plcue de semnalizare, instructajul specific i periodic de protec ia
muncii la locul de munc, elaborarea unor instructiuni proprii de securitatea muncii,
elaborarea i respectarea unui program de securitatea i sntatea n munc, dotarea
locurilor de munc cu trusa sanitar de prim ajutor, utilizarea de scule i utilaje certificate,
control permanent privind respectarea msurilor de securitatea muncii, etc.
La tablourile electrice de joas tensiune pentru evitarea electrocutrii prin atingere
indirect s-au aplicat doua msuri de protec ie : una principal care este legarea la nulul de
protecie i o msur suplimentar care este legarea la instala ia de legare la pamnt. n
partea desenat a proiectului se indic aceste msuri de protec ie.
n timpul execuiei este interzis folosirea instala iilor i a echipamentelor improvizate sau
necorespunztoare.
Pentru lucru la nlime, conform HG 1146/2006, Anexa 2, pct. 4, executantul va folosi
numai personal atestat medical pentru lucru la inl ime (Hot. 355/2007) i va utiliza utilaje
(platforme,etc ) sau mijloace individuale de protec ie ( centuri, etc ) pentru lucru la nl ime,
dup caz.
n magaziile de pe antier, executantul va aplica instruc iunile proprii de securitatea i
sntatea muncii pentru transportul prin purtare cu mijloace nemecanizate i depozitarea
materialelor, HG 1051/2006.
La manevre n instalaiile electrice scoase de sub tensiune se vor aplica prevederile din
HG 1146/2006, Anexa 1, pct. 3.3.22. Nu se vor face manevre cu instalaii electrice aflate sub
tensiune. Prin manevr se ntelege un ansamblu de opera ii care conduce la schimbarea
configuraiei unei instalaii electrice prin acionarea unor aparate de comuta ie .
Pe antier i n interiorul construciilor n lucru se vor utiliza tablouri de distribu ie n execu ie
capsulat sau tablouri nchise n cutii prevzute cu u i cheie , conform NP - I7/2002.
Toate echipamentele electrice cu tensiuni periculoase de clasa I de protec ie trebuie
legate suplimentar la instalaia de legare la pmnt conform HG 1146/2006, Anexa 1, pct.
3.3.13 si STAS 6271-81, STAS 12604/4-89 si STAS 12604/5-90, conform proiectului.
Montarea echipamentelor tehnice electrice i realizarea instala iilor electrice trebuie s se
desfoare n aa fel nct s nu se modifice concep ia de proiectare. n cazuri speciale,
modificrile trebuie s se fac numai cu acordul scris al proiectantului .

14.3 Obligaiile executantului

Executantul rspunde de realizarea lucrrilor de instala ii n condi ii care s asigure


evitarea accidentelor de munc. n acest scop este obligat :
COD PROIECT: 004.15 25 CONFIDENTIAL
S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

s analizeze documentaia tehnic dpdv al securit ii muncii


s aplice prevederile cuprinse n legislaia i normele / instruc iunile / prescrip iile /
standardele de securitatea muncii specifice lucrrii
s execute toate lucrrile i n scopul exploatrii ulterioare a instala iilor n condi ii
depline de securitate a muncii
s remedieze toate deficienele constatate cu ocazia probelor i recep iei astfel ca
lucrarea executat s poat fi utilizat n condi ii de securitate maxim posibi
s utilizeze pe santier msurile individuale i colective de securitatea muncii astfel ca s
se evite sau s se diminueze pericolele de accident sau mbolnvire profesional
s utilizeze pentru manevre n instalaiile electrice numai electricieni autoriza i conform
HG 1146/2006, Anexa 1, pct. 3.3.25
s aplice n totalitate cerinele din HG 1091/2006

14.4 Obligaiile beneficiarului

Beneficiarul rspunde de preluarea i apoi exploatarea lucrrilor de instala ii n condi ii care


s asigure securitatea muncii. n acest scop este obligat :
s analizeze proiectul dpdv al securitatii muncii
s respecte i s aplice toate normele i normativele de securitate a muncii
s respecte instruciunile de securitate a muncii ale echipamentelor livrate
s fac analiza factorilor de risc de accident i s ia msurile corespunztoare pentru
lucrrile de instalaii care se execut n paralel cu desf urarea procesului de produc ie,
s incheie cu executantul un protocol anexa la contract (clauze privind securitatea i
sntatea n munc la ncheierea contractelor de prestri de servicii cu ali angajatori) n
care s delimiteze zonele de lucru pentru care rspunderea privind asigurarea msurilor
de securitatea muncii revine executantului
s aplice cerinele prevazute n HG 1146/2006, Anexa 1, pct. 3.3.18.
n exploatare s existe obligatoriu documentele specificate in HG 1146/2006, Anexa 1,
pct. 3.3.2.4.
s prevad mijloace de prim ajutor eficace pentru personalul care lucreaz cu
videoterminale s aplice HG 1028/2006, care prevede obligativitatea examenului
medical oftamologic i utilizare de ochelari/ecrane de protec ie, dac e cazul
s prevad i s aplice msuri de prevenire i stingere a incendiilor
s ntocmeasc proceduri de intervenie pentru caz de criz sau dezastre i s aibe
pregatite echipe de intervenie, antrenate i dotate corespunztor.
s prevad sumele necesare pentru realizarea msurilor de securitate a muncii
s-i organizeze activitatea de securitate i sntate n munc conform Legea 319/2006
privind securitatea i sntatea muncii i a HG 1425/2006 normele de aplicare a legii
319/2006
recepia i punerea n funciune a instalaiei se va face numai dupa ce s-a constat i
consemnat, cu avizul proiectantului, c s-au respectat normele de securitate a muncii.
s nu permit accesul persoanelor neautorizate n instal iile electrice
s respecte n funcionare HG 1146/2006, Anexa 1, pct. 3.3.

COD PROIECT: 004.15 26 CONFIDENTIAL


S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

Beneficiarul trebuie s verifice c instala ia de legare la pmnt este corespunzatoare, s


se ingrijeasc s fac msuratori periodice a prizei de pmnt i s ob in buletine de
msurtori care s ateste ca priza de pmnt este n parametri normali, conform legisla iei.
n locurile cu pericol de incendiu beneficiarul trebuie s ia msuri de protec ie mpotriva
descrcrilor statice, conform HG 1146/2006, Anexa 1, pct. 3.3.4. i eventual dac e cazul i
ID 17-1996.

Obligaii comune: conf. art. 7, alin (5) din Legea 319/2006


Cnd n acelai loc de munc i desfoar activitatea lucrtori din mai multe ntreprinderi
i/sau uniti, angajatorii acestora au urmtoarele obligaii:
1. s coopereze n vederea implementarii prevederilor privind securitatea, sntatea i
igiena n munc, lund n considerare natura activitilor;
2. s i coordoneze aciunile n vederea proteciei lucrtorilor i prevenirii riscurilor
profesionale, lund n considerare natura activitilor;
3. s se informeze reciproc despre riscurile profesionale;
4. s informeze lucrtorii i/sau reprezentanii acestora despre riscurile profesionale.

14.5 Legislatia de securitate i sntate a muncii

La ntocmirea lucrrilor de proiectare s-a inut seama de legisla ia de securitate a


muncii aflat n vigoare. Se atrage aten ia executantului lucrrii i n special beneficiarului,
ca utilizator al instalatiei proiectate, c trebuie s respecte ntocmai aceast legisla ie din
motive morale i datorit rspunderii juridice care prevede c neluarea vreuneia din msurile
prevzute de dispozitiile legale referitoare la protec ia muncii sau nerespectarea de ctre orice
persoan a msurilor stabilite cu privire la protec ia muncii, constituie infrac iune i se
pedepsete ca atare.

Dm mai jos o lista restrns a acestei legislaii de care s-a tinut seama la proiectare i
care trebuie s fie completat de executant i beneficiar cu instruc iuni proprii de securitate i
sntate a muncii corespunzatoare activitilor desf urate. Beneficarul i executantul trebuie
de asemenea s elaboreze i instruciuni proprii de securitatea i sntatea muncii, specifice
instalaiei.
Legea Securitii i Sntii Muncii nr. 319 / 2006.
HG 1425/2006 privind Normele Metodologice de aplicare a Legii 319 / 2006.
Normativele NP - I 7/2002, I 18/2/2002 ,
Legislaia specific:
- HG 1091/2006 privind cerinele minime de securitate i sntate pentru locul de munc
- HG 971/2006 privind cerinele minime pentru semnalizarea de securitate i/sau de
sntate la locul de munca
- HG 1048/2006 privind cerinele minime de securitate i sntate pentru utilizarea de
ctre lucrtori a echipamentelor individuale de protecie la locul de munc
- HG 1146/2006 privind cerinele minime de securitate i sntate pentru utilizarea n
munc de ctre lucrtori a echipamentelor de munc
- HG 1876/2005 privind cerinele minime de securitate i sntate referitoare la
expunerea lucrtorilor la riscurile generate de vibra ii
- HG 493/2006 privind cerinele minime de securitate i sntate referitoare la expunerea
lucrtorilor la riscurile generate de zgomot

COD PROIECT: 004.15 27 CONFIDENTIAL


S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

- HG 1051 privind cerinele minime de securitate i sntate pentru manipularea


manual a maselor care prezint riscuri pentru lucrtori, n special de afeciuni
dorsolombare
- HG 1058/2006 privind cerinele minime pentru mbuntirea securitii i protecia
sntii lucrtorilor care pot fi expui unui potenial risc datorat atmosferelor explozive
- HG 1028 privind cerinele minime de securitate i sntate n munc referitoare la
utilizarea echipamentelor cu ecran de vizualizare
- HG 300/2006 privind cerinele minime de securitate i sntate pentru santierele
temporare sau mobile

15. MSURI DE PREVENIRE I STINGERE A INCENDIILOR

La ntocmirea prezentului proiect s-au respectat prevederile PSI din legisla ia tehnic n
vigoare:
- OMI 775/ 1998. Ordin al MI pentru aprobarea normelor generale de prevenire i stingere
a incendiilor.
- OMI 791/1998. Ordin al MI pentru aprobarea normelor metodologice de avizare i
autorizare privind prevenirea si stingerea incendiilor.
- HG 571/1998 pentru aprobarea categoriilor de constructii, instala ii tehnologice i alte
amenajri care se supun avizrii i autorizrii privind prevenirea i stingerea incendiilor.
- Normativ de prevenire a incendiilor pe durata executrii lucrrilor de construc ii i
instalaii aferente acestora -Indicativ C300/1994.
- S-au avut n vedere urmtoarele msuri:
- S-au folosit echipamente electrice corespuztoare mediului n care lucreaz;
- S-au folosit materiale necombustibile (metalice) sau greu combustibile (mase plastice)
care n condiii normale nu propag flacra;
- S-au respectat distanele i separrile impuse de normativele I 18//2 2002 si I 7/02 ntre
conductele instalatiilor proiectate i instalaiile vecine.
n ncperea n care se face monitorizarea vor exista mijloace de prim interven ie
(stingatoare cu CO2).
Beneficiarul trebuie s elaboreze planul de aparare i interven ie n caz de incendiu.
n timpul exploatrii se vor respecta prevederile PSI din legislatia tehnica in vigoare.

16. ALIMENTAREA CU ENERGIE ELECTRIC A SISTEMULUI

Alimentarea cu energie electric a consumatorilor prevzu ti n specifica ia de


echipamente din prezentul proiect cade n sarcina beneficiarului care are obliga ia de a
prevede un numr suficient de circuite pentru echipamentele din proiect.
Sursa de alimentare cu energie electric i cablurile necesare vor fi asigurate de ctre
beneficiar cu respectarea prevederilor din N.R.I-7-2002, privind alimentarea cu energie
electric a iluminatului de sigurant de interven ie i prevederile normativului I-18/2-2002,
privind alimentarea cu energie electric a circuitelor de semnalizare la incendiu i efrac ie:
- racordul la sursa primar de energie electric se va realiza printr-un tablou electric
special destinat acestui scop. Este interzis racordarea la acest circuit a altor consumatori.

COD PROIECT: 004.15 28 CONFIDENTIAL


S.C. Help Security S.R.L. Tel./Fax: 021/314.00.08
GSM: 0728/025.000
Bd. Iuliu Maniu, Nr. 5-7, "Cotroceni Business Center", E-mail: office@helpsecurity.ro
Corp A, Parter, Sector 6, Url:www.helpsecurity.ro;
Bucuresti, Romania, 061072 www.royal-security.ro

- tabloul electric este legat naintea ntrerupatorului general pentru alti consumatori iar
circuitul de alimentare al tabloului este protejat la scurtcircuit n aval de tabloul de racord.
- tabloul electric trebuie asigurat contra efractiei.
- Carcasa tabloului electric se leag suplimentar direct la instala ia de legare la pmnt
(art. 361 din NGPM/1966) printr-un conductor de cupru de sec iune minim 10mmp.(art
4.1.50. din I 7/01)
- Carcasa tabloului electric i carcasele centralelor de efrac ie , control acces, surse etc.
se leag la conductorul de nul de protecie PE, ca masur principal de protec ie contra
ocurilor electrice.

F
N
Carcasa tablou, centrala etc. PE

Masura principala

Masura secundara

COD PROIECT: 004.15 29 CONFIDENTIAL