Documente Academic
Documente Profesional
Documente Cultură
2007-2013
EXPERTIZA TEHNICA
PRIVIND STRUCTURILE CONSTRUCTIILOR
DIN STATIILE DE TRATARE TAIA SI
ZANOAGA SI CAPTARILE JIET, POLATISTE
SI IZVORUL, PETROSANI,
JUDETUL HUNEDOARA
Februarie 2015
EXPERTIZĂ TEHNICĂ
EXPERT TEHNIC
PROF. DR. ING. DUMITREL FURIŞ
BUCURESTI
, FEBRUARIE 2015
CUPRINS
1.
. .
3.1. DESCRIEREA CONCEPTIEI SI ALCĂTUIRII DECANTOARELOR CU
RECIRCULAREA NĂMOLULUI CONSTRUITE ÎN ROMÂNIA ................................................ 6
3.2. DESCRIEREA ALCĂTUIRII DECANTOARELOR CU RECIRCULAREA
NĂMOLULUI DIN STAŢIA DE TRATARE TAIA ..........................................................................8
2
6.3. CONCLUZII PRIVIND SIGURANŢA STRUCTURALĂ A DECANTORULUI CU
RECIRCULAREA NĂMOLULUI DIN STAŢIA DE TRATARE ZĂNOAGA ............................. 26
7. RECOMANDĂRI PRIVIND SOLUŢIILE NECESARE DE REABILITARE
STRUCTURALĂ .................................................................................................................................27
7.1. RECOMANDĂRI PRIVIND REBILITAREA STRUCTURALĂ A DECANTOARELOR
DIN STAŢIA TAIA ...........................................................................................................................28
7.1.1. SOLUŢIA MINIMALĂ .................................................................................................28
7.1.2. SOLUŢIA MAXIMALĂ ................................................................................................29
7.2. RECOMANDĂRI PRIVIND REABILITAREA STRUCTURALĂ A DECANTORULUI
DIN STAŢIA DE TRATARE ZĂNOAGA ...................................................................................... 29
7.2.1. SOLUŢIA MINIMALĂ .................................................................................................29
7.2.2. SOLUŢIA MAXIMALĂ ................................................................................................31
7.3. RECOMANDĂRI PRIVIND SOLUŢIILE DE REABILITARE STRUCTURALĂ LA
STATIILE
, DE FILTRE SI
, DE POMPARE .......................................................................................31
7.3.1. STATIA
, DE FILTRE SI
, DE POMPARE TAIA .........................................................31
7.3.2. STATIA
, , DE POMPARE ZĂNOAGA .............................................. 32
DE FILTRE SI
ANEXA 1 - DISPOZIŢII GENERALE - DECANTOARE CU RECIRCULAREA NĂMOLULUI
PENTRU DEBITE 0=2001/5, 0=3501/5.
3
EXPERTIZĂ TEHNICĂ
Întrucât beneficiarul lucrărilor, S.C. APA SERV VALEA JIULUI S.A. nu a putut
pune la dispoziţia expertului, proiectul iniţial al lucrărilor, s-a dispus:
efectuarea unor studii geotehnice În amplsament, pentru a cunoaşte
3
execuţiei lucrărilor, de reabilitare, astfel Încât să se asigure, fără Întrerupere,
alimentarea cu apă a localităţi lor.
Între 1,50 m si
, 6,00 m adâncime, se Întâlnesc o scuccesiune de strate formate
din argile prăfoase nisipoase sau nisipuri argiloase de natură coezivă sau slab
coezivă, de compresibilitate medie.
Caractersiticile fizico-mecanice ale pachetului coeziv I slab coeziv relevate de
studiu sunt:
umiditatea naturală w=19 - 28,10%;
indicele de plasticitate IP=18,23 - 38,66 %;
indicele de consistentă
, Ic=0,85 + 0,86;
- coeziunea c=15 - 45 kPa;
modelul de deformaţie liniară Eo=6000 + 32000 kPa.
Pentru orizonturile nisipoase situate la o adâncime de 5 - 6 m caracteristicile
fizico - mecanice indicate de studiu sunt:
unghiul de frecare internă q> = 25 -45 0 ;
- coeficientul Poisson JlO= 0,29 + 0,35;
modulul de deformaţie liniară Eo= 12000+ 18000 kPa.
Apa subterană a fost Întâlnită la o anumită adâncime de 0,80 m faţă de nivelul
terenului numai În unele foraje, prezenţa acesteia datorându-se pierderilor din
conducte şi a neetanşeităţii construcţiilor purtătoare de apă (decantor,
microhidrocentrala din imediata apropiere a amplasamentului).
4
Studiul recomandă fundarea la o adâncime minimă de 2,00 m faţă de cota
terenului amenajat, presiunea convenţională de bază ce poate fi adoptată În calcule
fiind de 230 kPa.
5
3. DESCRIEREA ALCĂTUIRII STRUCTURILOR DIN STAŢIILE DE TRATARE
ZĂNOAGA ŞI TAIA.
6
evacuarea nămolului se asigură prin conducte pozate sub nivelul radierului
În trei başe dispuse la un unghi de 120°.
decantorul este prevăzut cu un pod raclor metalic, radial având pivotul În
centrul decantorului şi calea de rulare reprezentată de o grindă circulară
Pentru Întreaga gamă de debite 0=200 Ils, 0=350 Ils, 0=500 Ils, 0=800 Ils,
0=1000 Ils, legătura plăcii curbe tronconice cu radierul a fost concepută ca o legătură
specială care Îndeplineşte următoarele funcţiuni:
precomprimată;
legată monolit cu cadrele din beton armat. Diametrul plăcii curbe cilindrice este de
11,40 m, iar grosimea plăcii de 20 cm.
Ansamblul structural pereţi exteriori-jgheab periferic de colectare apă
8
• Înălţimea circa 3,70 m.
o placă curbă cilindrică din beton armat având:
• diametrul exterior 29,00 m;
• Înălţimea 2,70 m;
• grosimea 25-30 cm;
o placă curbă exterioară a jgheabului de colectare, având diametrul exterior
de 31,34 m şi o Înălţime de circa 1,70 m;
radierul jgheabului de colectare de forma unei plăci inelare cu diametrul
interior de 29 m şi diametrul exterior de 31,34 m.
Calea de rulare a podului raclor este o grindă circulară având diametrul mediu
de 21,25 m şi o secţiune de circa 30 x 35 cm.
Grinda de rulare este susţinută de 20 de stâlpi din beton armat Încastraţi În
radier, legătura dintre stâlpi şi grindă fiind o legătură de continuitate.
Sistemul de colectare al apei decantate este alcătuit din 20 conducte prevăzute
cu orificii, conductele fiind susţinute de 20 grinzi radiale legate de stâlpi şi placa curbă
evacuare a nămolului.
9
Debitul calculat anterior trebuie verificat de un proiectant tehnologic luând În
considerare toţi parametrii de dimensionare.
Din experienţa lucrărilor de acest gen, structura decantorului trebuie
dimensionată În grupările fundamentale, atât la starea limită de rezistenţă cât şi la
starea limită de deschidere a fisurilor, valorile admisibile ale deschiderilor de fisură
fiind:
• af,adm:S: 0,1 mm pentru elementele supuse la Întindere centrică sau
S.C. HALCROW ROMANIA S.R.L. sunt arătate În planşa nr. 2, din prezenta expertiză.
Din analiza vizuală in situ şi relevarea dimensiunilor principale ale decantorului
rezultă următoarea alcătuire:
10
de continuitate Între ele, iar placa curbă tronconică legată monolit de
radier:
• placa tronconică are diametrul superior de 23,10 m, diametrul
inferior de 15,10 m, iar Înăltimea
, de 4,00 m;
• placă curbă cilindrică interioară are diametrul de 23,10 m şi o
Înăltime
, de 2,40 m;
• spre deosebire de decantorul din staţia de tratare TAIA, unde
jgheabul periferic este În consolă, În staţia de tratare
ZĂNOAGA, este consolidat prin executarea a două inele din
beton armat, legate între ele cu stâlpi având secţiunea 30 x 40
cm, care probabil au fost fundaţi independent de radierul
decantorului. Trebuie remarcat faptul că consolidarea
jgheabului este urmarea unor defecţiuni apărute pe parcursul
execuţiei sau În timp, întrucât eforturile efective din jgheabul
periferic nu justifică adoptarea unei astfel de soluţii.
tronconice si
, 6,70 m În zona basei
, de colectare a nămolului,
11
Luând În considerare o Încărcare superficială de 1,70 m3/h/m 2 şi ţinând cont de
aria de limpezire din camera de decantare, debitul aproximativ al decantorului este:
parametrii de dimensionare.
12
Dimensiunile În plan sunt de 10,00 x 14,30 m. Infrastructura este reprezentată
de o cuvă din beton armat, iar suprastructura este pe cadre şi planşeul din beton
armat.
Planşeul de acoperiş din beton a fost acoperit cu o şarpantă din lemn şi
3.5.1 Staţia de filtrarea apei din locaţia ZĂNOAGA este o staţie de filtre având drenaj
cu plăci cu crepine şi rezervor de apă filtrată sub cuvele de filtrare.
Staţia are 8 cuve de filtrare cu dimensiunile unei cuve de 2,85 x 8,05 m,
dimensiunile totale În plan fiind de 30,00 x 12,00 m. Infrastructura staţiei sub forma
unei cuve din beton armat, este alcătuită din radier, pereţi exteriori, pereţi şicană,
13
4. STAREA TEHNICĂ ACTUALĂ A LucRĂRILOR
segregate;
• rosturi de turnare netratate corespunzător prin care se produc
exfiltratii;
,
• fisuri şi crăpături În pereţii cilindrici ai jgheabului periferic de colectare
a apei decantate;
• atacul chimic al sulfatului de aluminiu pe elementele structurale
componente ale camerei de reacţie şi În special În partea superioară
14
4.1.2. STAREA TEHNICĂA STAŢIEI DE FILTRARE AAPEI
Din analiza vizuală in situ a staţiei de filtre şi a staţiei de pompare s-au constatat
următoarele avarii si
, defectiuni:
,
• fisuri şi exfiltraţii din cuvele de filtrare a apei În galeria de conducte;
• corodarea puternică a instalaţiilor hidraulice din galeria de conducte;
• radierul cuvelor de filtrare a apei (planşeul peste rezervor) puternic
atacat de ionii de clor, cu intrarea În coroziune a armăturilor, fenomen
ce a fost favorizat şi de o acoperire insuficientă a armăturilor;
ineficientei
, sistemului de ventilatie.
,
15
• atacul chimic al sulfatului de aluminiu În camera de reacţie
şi amestec.
ZĂNOAGA.
Cu toate acestea pot fi semnalate următoarele defecţiuni:
TAIA, dacă În faza anterioară nu s-a executat reabilitarea şi protecţia planşeului peste
rezervor.
• chepengul metalic pentru montarea şi scoaterea utilajelor din staţia
5.1. INTRODUCERE
existente:
16
• acceleraţia de vârf a9=0, 12g;
• perioada de colţ Tc=0,70 s;
• factorul de amplificare dinamic maxim J3=2,75.
• conform codului seismc P1 00/2013, corespunzător lucrărilor noi:
• acceleraţia de vârf a9=0, 1Og;
• perioada de colţ Tc=0,70 s;
• factorul de amplificare dinamic maxim J3=2,50.
Din analiza parametrilor indicaţi În cele două coduri, rezultă că lucrările noi
trebuie calculate la un nivel de siguranţă inferior lucrărilor existente, fapt ce
demonstrează cel puţin o inconsecvenţă În ceea ce priveşte nivelul de asigurare.
Având În vedere starea tehnică actuală si
, destinatia
, functională
, a lucrărilor,
PLACA CURBA
CR.INJRICA
PlACA CURBA
CIl.INJRICA
CORP 2
PLACA CURBA
TRONCONICA
17
În calcule s-a luat În considerare legătura dintre elementele structurale
componente şi următoarele tipuri de acţiuni: greutatea proprie şi presiunea
hid rostatică.
De asemenea s-au calculat valorile presiunilor hidrodinamice induse de
acţiunea seismică, precum şi rezultantele acestora.
Calculele s-au efectuat ţinând cont de tipodimensiunile măsurate in situ,
considerând grosimea elementelor: h1=O,25 m, h2=O,20 m, h3=O,25 m şi h4=O,35 m
atât pentru decantoarele din staţia ZĂNOAGA, cât si pentru decantoarele din staţia
TAIA.
Pentru a putea urmări rezultatele calculelor se menţionează:
1[\ I
-,
tronconică:
18
N cNx ..i ••
" .1 +-- ' u.'i.
X ex.
În tabelele 5.1; 5.2; 5.3; 5.4; 5.5 sunt prezentate eforturile secţionale cumulate
din acţiunea greutăţii proprii şi a presiunii hidrostatice pentru decantoarele din
ZĂNOAGA, exprimate după cum urmează:
Tabelul 5.1
19
GP+PH corp2
~ Nx(~) N9(~) Mx(~) M9(~) Qx(~)
o -0.87395 13.79689 -0.22331 -0.04466 -0.36838
0.1 -0.79695 12.78831 -0.17511 -0.03502 -0.32035
0.2 -0.71995 11.70103 -0.13356 -0.02671 -0.27348
0.3 -0.64295 10.55367 -0.09844 -0.01969 -0.22855
0.4 -0.56595 9.36199 -0.06944 -0.01389 -0.18612
0.5 -0.48895 8.13898 -0.04619 -0.00924 -0.14662
0.6 -0.41195 6.89507 -0.02824 -0.00565 -0.11033
0.7 -0.33495 5.63833 -0.01514 -0.00303 -0.07744
0.8 -0.25795 4.37465 -0.00639 -0.00127 -0.04806
0.9 -0.18095 3.10795 -0.00151 -0.00031 -0.02224
1 -0.10395 1.84046 0.00000 0.00000 0.00000
Tabelul 5.2
GP+PH corp3
p pl Nr(p 1) N9(p 1) Mr(p) M9(p) Qr(p)
1 0.93931 -1.83117 18.85372 -1.27671 -0.17449 2.32555
1.00646 0.94538 -1.66921 18.69176 -1.06060 -0.14083 2.17483
1.01292 0.95145 -1.51103 18.53359 -0.85982 -0.10851 2.02541
1.01938 0.95751 -1.35651 18.37906 -0.67410 -0.07764 1.87729
1.02585 0.96358 -1.20553 18.22808 -0.50321 -0.04831 1.73041
1.03231 0.96965 -1.05799 18.08055 -0.34692 -0.02063 1.58476
1.03877 0.97572 -0.91379 17.93634 -0.20499 0.00531 1.44031
1.04523 0.98179 -0.77281 17.79536 -0.07720 0.02945 1.29703
1.05169 0.98786 -0.63498 17.65754 0.03664 0.05168 1.15489
1.05815 0.99393 -0.50020 17.52275 0.13674 0.07193 1.01387
1.06462 1 -0.36838 17.39093 0.22331 0.09013 0.87395
Tabelul 5.3
GP+PHcorp4
~ Nx(~) N9(~) Mx(~) M9(~) Qx(~)
O -4.21700 40.96949 -2.27001 -0.45400 -4.00013
0.1 -4.13450 39.57754 -1.87802 -0.37560 -3.84001
0.2 -4.05200 37.97955 -1.50192 -0.30039 -3.68273
0.3 -3.96950 36.21675 -1.14132 -0.22827 -3.52987
0.4 -3.88700 34.32868 -0.79575 -0.15915 -3.38267
0.5 -3.80450 32.35324 -0.46457 -0.09291 -3.24204
0.6 -3.72200 30.32674 -0.14710 -0.02942 -3.10858
0.7 -3.63950 28.28399 0.15739 0.03148 -2.98257
0.8 -3.55700 26.25838 0.44966 0.08994 -2.86401
0.9 -3.47450 24.28197 0.73043 0.14608 -2.75261
1 -3.39200 22.38555 1.00040 0.20008 -2.64782
Tabelul 5.4
20
GP+PH corp5
~ Nx(~) N9(~) Mx(~) M9(~) Qx(~)
o -28.05115 -6.76962 9.58015 0.00000 11.40156
0.1 -26.44691 -6.73809 4.65227 0.00000 7.99372
0.2 -24.81781 4.20409 1.35312 0.00000 5.06136
0.3 -22.87742 18.51537 -0.64661 0.00000 2.85215
0.4 -20.60561 32.08951 -1.72146 0.00000 1.35334
0.5 -18.09353 42.98053 -2.20088 0.00000 0.44572
0.6 -15.46349 50.48587 -2.34057 0.00000 -0.01717
0.7 -12.83230 54.54365 -2.32232 0.00000 -0.17301
0.8 -10.29794 55.36471 -2.26486 0.00000 -0.13787
0.9 -7.93754 53.22545 -2.23710 0.00000 -0.00470
1 -5.81039 48.36425 -2.27001 0.00000 0.15335
Tabelul 5.5
În tabelele 5.6,5.7,5.8,5.9,5.10 sunt prezentate valorile eforturilor din acţiunea
greutăţii proprii şi a presiunii hidrostatice pentru decantoarele din staţia TAIA.
GP+PH corpi
~ Nx(~) N9(~) Mx(~) M9(~) Qx(~)
O -1.27270 28.87643 -0.50398 -0.10079 -1.16428
0.1 -1.15582 25.71133 -0.32936 -0.06587 -0.89532
0.2 -1.03895 22.42499 -0.19773 -0.03955 -0.65881
0.3 -0.92207 19.06548 -0.10347 -0.02069 -0.45587
0.4 -0.80520 15.66733 -0.04080 -0.00816 -0.28713
0.5 -0.68832 12.25353 -0.00389 -0.00077 -0.15289
0.6 -0.57145 8.83771 0.01315 0.00263 -0.05326
0.7 -0.45457 5.42626 0.01618 0.00323 0.01178
0.8 -0.33770 2.02045 0.01110 0.00222 0.04231
0.9 -0.22082 -1.38137 0.00375 0.00075 0.03837
1 -0.10395 -4.78174 0.00000 0.00000 0.00000
Tabelul 5.6
GP+PHcorp2
~ Nx(~) N9(~) Mx(~) M9(~) Qx(~)
O -1.03895 21.34624 -0.32250 -0.06450 -0.49747
0.1 -0.94545 19.61799 -0.24465 -0.04893 -0.41905
0.2 -0.85195 17.75838 -0.17977 -0.03595 -0.34495
0.3 -0.75845 15.80213 -0.12705 -0.02541 -0.27641
0.4 -0.66495 13.77746 -0.08543 -0.01709 -0.21433
0.5 -0.57145 11.70668 -0.05377 -0.01075 -0.15932
0.6 -0.47795 9.60678 -0.03084 -0.00617 -0.11180
0.7 -0.38445 7.49005 -0.01532 -0.00307 -0.07200
0.8 -0.29095 5.36486 -0.00591 -0.00119 -0.04007
0.9 -0.19745 3.23630 -0.00125 -0.00025 -0.01606
1 -0.10395 1.10692 0.00000 0.00000 0.00000
21
Tabelul 5.7
GP+PH corp3
p pl Nr(p 1) N9(p 1) Mr(p) M9(p) Qr(p)
1 0.93931 -2.32116 28.66673 -1.44035 -0.19285 2.65474
1.00646 0.94538 -2.12286 28.46843 -1.19000 -0.15161 2.48815
1.01292 0.95145 -1.92833 28.27390 -0.95668 -0.11216 2.32274
1.01938 0.95751 -1.73749 28.08307 -0.74016 -0.07461 2.15848
1.02585 0.96358 -1.55026 27.89583 -0.54022 -0.03904 1.99533
1.03231 0.96965 -1.36652 27.71209 -0.35666 -0.00552 1.83329
1.038n 0.97572 -1.18621 27.53178 -0.18926 0.02584 1.67234
1.04523 0.98179 -1.00923 27.35480 -0.03784 0.05499 1.51245
1.05169 0.98786 -0.83549 27.18106 0.09780 0.08183 1.35360
1.05815 0.99393 -0.66493 27.01051 0.21785 0.10632 1.19577
1.06462 1 -0.49747 26.84304 0.32250 0.12838 1.03895
Tabelul 5.8
GP+PHcorp4
~ Nx(~) N9(~) Mx(~) M9(~) Qx(~)
O -4.75244 54.50563 -3.20375 -0.64075 -4.86673
0.1 -4.66994 53.08588 -2.72472 -0.54494 -4.71375
0.2 -4.58744 51.42753 -2.26098 -0.45220 -4.56131
0.3 -4.50494 49.57119 -1.81239 -0.36248 -4.41092
0.4 -4.42244 47.55612 -1.37869 -0.27574 -4.26378
0.5 -4.33994 45.42028 -0.95949 -0.19190 -4.12086
0.6 -4.25744 43.20037 -0.55435 -0.11087 -3.98284
0.7 -4.17494 40.93183 -0.16274 -0.03254 -3.85019
0.8 -4.09244 38.64896 0.21587 0.04317 -3.72312
0.9 -4.00994 36.38488 0.58206 0.11641 -3.60161
1 -3.92744 34.17167 0.93637 0.18728 -3.48543
Tabelul 5.9
GP+PH corp5
~ Nx(~) N9(~) Mx(~) M9(~) Qx(~)
O -28.15371 -7.14235 12.67081 0.00000 13.40621
0.1 -26.77797 -6.87327 6.61475 0.00000 9.77904
0.2 -25.35324 5.35998 2.35557 0.00000 6.59132
0.3 -23.62429 21.97688 -0.41616 0.00000 4.07418
0.4 -21.54972 38.44500 -2.06614 0.00000 2.24776
0.5 -19.19316 52.31824 -2.93503 0.00000 1.02972
0.6 -16.65931 62.48034 -3.30459 0.00000 0.29863
0.7 -14.05956 68.59802 -3.38965 0.00000 -0.07170
0.8 -11.49554 70.75081 -3.34238 0.00000 -0.19615
0.9 -9.05308 69.19566 -3.26178 0.00000 -0.17242
1 -6.80178 64.22834 -3.20375 0.00000 -0.08082
Tabelul 5.10
22
Acţiunea seismică produce suprapresiuni hidrodinamice impulsive şi
23
5.3. DIMENSIONAREA ARMĂTURILOR ÎN SECŢIUNEA DE EFORT
MAXIM
24
6.1.3. Staţiile de filtre prezintă o serie de defecţiuni care afectează
6.2.1. Decantoarele radiale din staţia TAIA sunt total compromise din
punctul de vedere al rezistenţei, etanşeităţii şi stabilităţii, fiind practic
abandonate.
6.2.2. Siguranţa structurală a decantorului cu recircularea nămolului, din
punctul de vedere al rezistenţei şi stabilităţii stă sub semnul întrebării
din următoarele considerente:
nivelul de solicitare al structurii este ridicat, cu dezvoltarea
de eforturi axiale inelare de Întindere mari, circa
Nmax
9 -- 70 , 75 tf/m si
, ca urmare se impunea
variaţiilor de temperatură;
25
este puţin probabil ca armăturile circulare existente În
lucrare să corespundă cu variaţia eforturilor inelare
calculate În prezenta expertiză şi ca urmare, trebuie
verificat in situ dacă armarea circulară este afină cu
variaţia eforturilor;
creşterea mărimii fisuri lor peste 0,20 mm pune În pericol
durabilitatea lucrării;
armăturilor.
26
exfiltraţiile din decantor sunt importante atât prin fisuri cât
şi prin rosturile de turnare care nu au fost tratate
corespunzător;
Din analiza stării tehnice actuale, din verificările in situ şi prin calcul, rezultă că
pentru structurile construcţiilor din cele două staţii de tratare TAIA şi ZĂNOAGA sunt
necesare ample lucrări de reabilitare.
Soluţiile de reabilitare structurală menite să asigure rezistenţa, stabilitatea,
etanşeitatea şi durabilitatea, trebuie obligatoriu corelate cu cerinţele tehnologice şi
Existenţa unui singur decantor În fiecare dintre cele două staţii creează dificultăţi
27
sistem de alimentare cu apă, astfel încât să nu fie întreruptă alimentarea cu apă a
localitătilor.
,
Din punctul de vedere al soluţiilor de reabilitare structurală se pot adopta două
categorii de soluţii:
structurale actuale.
7.1.1. SOLUTIA
, MINIMALĂ
sunt:
scoaterea din funcţiune şi golirea decantorului;
îndepărtarea tencuielilor interioare şi exterioare prin
curăţare cu apă sub presiune cu o instalaţie capabilă să
exfiltraţii;
28
repararea zonelor segregate cu mortare de reparaţie
7.2.1. SOLUTIA
, MINIMALĂ
29
inclusiv până la legătura cu microhidrocentrala din
apropiere;
îndepărtarea tencuielilor interioare şi exterioare de pe
întreaga suprafaţă a decantorului;
îndepărtarea betonului atacat chimic de pe cadrele
corpului central;
verificarea in situ a concordantei
, dintre armăturile
30
7.2.2. SOLUŢIA MAXIMALĂ
anume:
• varianta a) constând În executarea lucrărilor minimale stipulate la
paragraful 7.2.1. plus lucrări de consolidare care să suplinească
presiunea hidrostatică;
7.3.1. STATIA
, DE FILTRE SI
, DE POMPARE TAIA
existent;
31
executarea pe suprafaţa torcretata a unei protecţii pe bază
de răşini.
7.3.2. STATIA
, , DE POMPARE ZĂNOAGA
DE FILTRE SI
În staţia de tratare de ZĂNOAGA (mai puternic avariată decât staţia TAIA), sunt
necesare următoarele lucrări de reabilitare:
un sistem de ventilaţie şi reabilitare termică care să elimine condensul şi
32
asigura caiete de sarcini privind calitatea materialelor, tehnologiile şi
lucrărilor.
33
ANEXA FOTO
STATIE TAIA
1.Decantor
Situatie actuala Observatii
Vedere de ansamblu
decantor.
Degradări ale betonului in
peretele exterior al cuvei.
Degradări ale betonului in
peretele exterior al cuvei.
Degradări ale betonului in
peretele exterior al cuvei.
Degradări ale betonului in
peretele exterior al cuvei.
Degradări ale betonului in
peretele exterior al cuvei.
Degradări ale betonului in
peretele exterior al cuvei in
zona piesei de trecere.
Degradări ale betonului in
peretele exterior al cuvei in
zona piesei de trecere.
Degradări ale betonului in
peretele exterior al cuvei.
Degradări ale betonului in
peretele exterior al cuvei.
Degradări ale stratului de
acoperire cu beton a
armaturilor
Degradări ale stratului de
acoperire cu beton a
armaturilor
Degradări ale stratului de
acoperire cu beton a
armaturilor
Degradări ale stratului de
acoperire cu beton a
armaturilor. Armatura
expusa.
Degradări ale stratului de
acoperire cu beton a
armaturilor
Degradări ale stratului de
acoperire cu beton a
armaturilor. Armatura
expusa.
Degradări ale stratului de
acoperire cu beton a
armaturilor
Degradări ale stratului de
acoperire cu beton a
armaturilor
Degradări ale stratului de
acoperire cu beton a
armaturilor
Degradări ale stratului de
acoperire cu beton a
armaturilor. Armatura
expusa.
Degradări ale stratului de
acoperire cu beton a
armaturilor.
2. Stație Filtre
Situatie actuala Observații
Vedere camera filtrelor
Vedere filtre
Vedere filtre
Degradări ale finisajelor
Degradări ale finisajelor
Degradări ale finisajelor
Degradări ale betonului
Degradări ale finisajelor
Degradări ale finisajelor
Degradări ale betonului
Degradări ale finisajelor
Degradări ale betonului. Armatura
expusa.
Degradări ale betonului. Armatura
expusa.
Vedere filtre
Vedere filtre
Infiltrații in zona pieselor de trecere
prin pereți
Coroziunea conductelor si
elementelor metalice
Coroziunea conductelor si
elementelor metalice
Coroziunea conductelor si
elementelor metalice
Degradări in zona accesului in
rezervor
Degradări in zona accesului in
rezervor
Degradări ale finisajelor exterioare
Degradări ale finisajelor exterioare
STATIE ZANOAGA
1.Decantor
Situație actuala Observații
Vedere de ansamblu
decantor.
Degradări ale betonului in
peretele exterior al cuvei.
Local sunt observabile
exfiltrații.
Degradări ale betonului in
peretele exterior al cuvei.
Local sunt observabile
exfiltrații.
Degradări ale betonului in
peretele exterior al cuvei.
Local sunt observabile
exfiltrații.
Degradări ale betonului in
peretele exterior al cuvei.
Local sunt observabile
exfiltrații.
Degradări ale betonului in
peretele exterior al cuvei.
Local sunt observabile
exfiltrații.
Degradări ale betonului in
peretele exterior al cuvei.
Degradări ale betonului in
peretele exterior al cuvei.
Degradări ale betonului in
peretele exterior al cuvei in
zona pieselor de trecere.
Degradări ale betonului in
peretele exterior al cuvei in
zona pieselor de trecere.
Local sunt observabile
exfiltrații.
Degradări ale betonului in
peretele exterior al cuvei.
Degradari ale betonului.
Zone de exfiltratie
Degradări ale stratului de
acoperire cu beton a
armaturilor. Armatura
expusa.
Degradări ale stratului de
acoperire cu beton a
armaturilor. Armatura
expusa.
Degradări ale stratului de
acoperire cu beton a
armaturilor. Armatura
expusa.. Degradări cauzate
de atacul sulfatic asupra
betonului.
Degradări ale stratului de
acoperire cu beton a
armaturilor. Armatura
expusa.. Degradări cauzate
de atacul sulfatic asupra
betonului.
Degradări cauzate de atacul
sulfatic asupra betonului.
Degradări cauzate de atacul
sulfatic asupra betonului.
Degradări cauzate de atacul
sulfatic asupra betonului.
2. Stație Filtre
Situație actuala Observații
Degradări ale finisajelor
Degradări ale finisajelor
Degradări ale finisajelor
Degradări ale finisajelor
Acces filtre
Acces filtre
Filtre
Filtre
Filtre
Degradări ale finisajelor
Filtre
Degradări ale finisajelor
Filtre
Filtre
Degradări ale finisajelor
Degradări ale betonului
Degradări ale finisajelor
Degradări ale finisajelor
Degradări ale betonului
Coroziunea conductelor si
elementelor metalice
Infiltrații in zona pieselor de
trecere ale conductelor prin
pereții rezervorului.
Degradări ale finisajelor
Degradări ale betonului
Degradări ale finisajelor
3 Rezervor sub filtre
Degradări ale stratului de
acoperire cu beton a
armăturilor cauzate de
atacul ionilor de clor.
Degradări ale stratului de
acoperire cu beton a
armăturilor cauzate de
atacul ionilor de clor.
Degradări ale stratului de
acoperire cu beton a
armăturilor cauzate de
atacul ionilor de clor.
Degradări ale stratului de
acoperire cu beton a
armăturilor cauzate de
atacul ionilor de clor.
4 Aspect exterior
Degradări ale finisajelor
exterioare si ale
acoperișului deasupra
camerei filtrelor.
Degradări ale finisajelor
exterioare.
Degradări ale finisajelor
exterioare si ale
acoperișului deasupra
camerei filtrelor.
Degradări ale finisajelor
exterioare si ale
acoperișului deasupra
camerei filtrelor.
Degradări ale finisajelor
exterioare si ale
acoperișului deasupra
camerei filtrelor.
Degradări elementelor
metalice si ale plăcii de
beton armat.
Degradări ale finisajelor
exterioare.
Degradări in zona bazinelor
pentru sulfatul de aluminiu.
Degradări ale finisajelor
exterioare in zona bazinelor
pentru sulfatul de aluminiu.
Structura metalica șarpantă
improvizata.
Degradări ale finisajelor
exterioare in zona bazinelor
pentru sulfatul de aluminiu.
Structura metalica șarpantă
improvizata.
ANEXA PIESE DESENATE
Statia Zanoaga
Arhitectura A1-A8
Rezistenta R1
VJ - CL8 - SF - 01 - R_ST Filtre_Plan planseu
Instalatii S1-S5
VJ - CL8 - SF - 01 - S_Plan demisol
VJ - CL8 - SF - 02 - S_Plan demisol
VJ - CL8 - SF - 03 - S_ST_Plan parter
VJ - CL8 - SF - 04 - S_Plan etaj
Statia Taia
ARHITECTURA A11-A16
·..: --S.......,.U--.S-.
~fS~~~\'"m5iTD~~"~·~('·~~~";;"""""'---""""'W=-~ · PENStbf\fAT~~c1J~~:~~:~~<·,~·";·~· ~~
.'..•.
.""'""_. ,,'~'=..itI1
PENTRU 3501/s .:1~,'> 2716. ·
:./.
~,~--.-.-- - .-.-'-.,- :- .. <" ' i..
., "
..
~ ' '
/~.
. ~' ,
... ...' . ~
,,-
.
. ......
,'
.1
.'
,.
''j'
. .
;.'
.'
::; ;::;;; , .' , ,' .','
. ::'
.....
... ....
. ' ., " .; .
o'::
;' "
",; .
..;s.. ',.~. .. 7.
':';' :"'-":.-'~J:" ...... ".r+i"·"'ilfJqU"c,~,"--,
.. .....
'~., '. r' '~f