Sunteți pe pagina 1din 13

Pr. nr.

80/2021

CONSTRUIRE STATIE DISTRIBUT


CONSTRUIRE STATIE DISTRIBUTI

faza - d.T.A.C.
BENEFICIAR - S.C. LACUL VIOLET S.R.L. PROIECTANT - S.C. OPSCAPE HUB
S.R.L.

- TULCEA -
MEMORIU DE ARHITECTURA

1. INFORMATII GENERALE PRIVIND OBIECTIVUL DE


INVESTITII

1.1 Denumirea CONSTRUIRE STATIE DISTRIBUTIE CARBURANTI,


proiectului SPATIU COMERCIAL, ALIMENTATIE PUBLICA SI
SPALATORIE
1.2 Amplasament Str. BABADAG nr.164, mun.Tulcea, N.C. 31815

1.3 Beneficiar S.C. LACUL VIOLET S.R.L.


1.4 Elaborator S.C. OPSCAPE HUB S.R.L. - Tulcea
1.5 Numarul proiectului 80/2021
1.6 Faza de proiectare D.T.A.C.

2. PARTICULARITATI ALE AMPLASAMENTULUI


a) INCADRARE IN LOCALITATE SI ZONA;
Conform R.L.U. – U.T.R. 30 - CETATII
Conform PUZ aprobat prin HCL nr. 124 din 31.05.2022 – IS(co,ps) – INSTITUTII SI
SERVICII PUBLICE – subzona comert, prestari servicii, functiuni compatibile si
complementare
b) DESCRIEREA AMPLASAMENTULUI;
Amplasamentul propus se afla in intravilanul municipiului Tulcea, pe strada
BABADAG (latura nordica), intre sens giratoriu LIDL si PETROM, in zona de Sud a
orasului. Amplasamentul este format dintr-un teren leber de constructii ce se poate identifica
prin numarul cadastral/carte funciara 31815.
 Categoria de folosinta : IS
 Suprafata : N.C. 31815 – 5000mp
 Forma : neregulata
 Dimensiuni : aproximativ 100m x 60m
 Vecinatati :
NORD Domeniu privat N.C.32100 (liber de constructii)
EST Domeniu privat N.C.35558 (liber de constructii) ; N.C.34395 (teren sport)
SUD Domeniu public N.C. 43168 – Str.BABADAG
VEST Domeniu privat N.C.38849 (liber de constructii)

pg. 1
 Pr. nr. : 80/2021
 Proiect. : CONSTRUIRE STATIE DISTRIBUTIE CARBURANTI, SPATIU COMERCIAL, ALIMENTATIE PUBLICA
SI SPALATORIE
 Beneficiar: S.C. LACUL VIOLET S.R.L.
 Faza: D.T.A.C.
c) CAILE DE ACCES PERMANENTE, CAILE DE COMUNICATII;
Accesul rutier in teritoriul studiat se face pe strada BABADAG, artera principala de
circulatie in municipiu. Terenul studiat este amplasat intr-o zona fara probleme de circulatie.
Strada BABADAG are sens dublu de circulatie (doua benzi de circulatie pe sens).
Acces carosabil :
Accesul se va face cu respectarea articolului 25 din Regulamentul general de urbanism
direct dintr-un drum public si a anexei nr. 4 referitor la gabaritul drumului. Lucrarile de
realizare a accesului carosabil se vor face cu asigurarea continuitatii scurgerii apelor pluviale.
In ceea ce priveste parcajele, se vor executa avand in vedere respectarea prevederilor
regulamentului de parcari a Municipiului Tulcea.
Acces pietonal :
Cladirea rezultata in faza de proiectare (spatiu alimentatie publica si spatiu vanzare)
va avea prevazuta pietonale la toate intrarile principale si secundare ale cladirii. Restul
cladirilor ce au utilitate tehnica sau auto nu vor fi prevazute cu pietonale datorita functiunii
acestora.
d) PARTICULARITATI TOPOGRAFICE;
Ridicarea topografica a determinat cunoasterea precisa a planimetriei, indicand un
teren cu o panta naturala de la Est la Vest de cca. 8%, cotele de teren variind intre +94.00m
(in zona de Vest a terenului), si +90.00m (in partea de Est a amplasamentului).

e) CONDITII DE CLIMA SI INCADRAREA IN ZONELE DIN HARTILE


CLIMATERICE;
Acestea sunt prevazute de STAS 6472/2-83 - temperatura de calcul pentru vara; SR
10907/1-97 - temperatura de calcul pentru iarna; STAS 10101/20-90 - viteza de calcul a
vanturilor si STAS 10101/21-92 -incarcarile date de zapada;
Clima municipiului Tulcea este temperat-continentala cu influente sub-mediteraneene.
Iarna se face simtit aerul arctic, din nord, care provoaca scaderea temperaturii. Temperatura
medie anuala din Tulcea este una dintre cele mai ridicate din tara, fiind de 10,8 grade.
Precipitatiile medii anuale sunt de 350-500 mm. Debitele Dunarii sunt in medie, la Tulcea, de
aproximativ 5000-6000 mc/s, minimele fiind de 2000 mc/s, iar maximele de 15.000-16.000
mc/s.
Pe teritoriul orasului nu sunt cursuri de apa permanente cu exceptia Dunarii.

f) ZONA SEISMICA DE CALCUL;


Definita prin acceleratia de proiectare ag = 0,20 g si o perioada de colt Tc = 0,7 sec.
(IMR = 225 ani si 20% probabilitate de depasire in 50 ani). Conform hartii de zonare seismica
din Normativul P100/2013.
pg. 2
 Pr. nr. : 80/2021
 Proiect. : CONSTRUIRE STATIE DISTRIBUTIE CARBURANTI, SPATIU COMERCIAL, ALIMENTATIE PUBLICA
SI SPALATORIE
 Beneficiar: S.C. LACUL VIOLET S.R.L.
 Faza: D.T.A.C.
g) PARTICULARITATI GEOTEHNICE ALE TERENULUI;
Conform studiului geotehnic atasat in documentatie.

h) MODUL DE ASIGURARE AL UTILITATILOR;


Amplasamentul dispune de posibilitati de racord, in imediata vecinatate, la toate
utilitatile urbane. Pe teritoriul analizat exista racorduri la utilitati si nu au fost identificate
conducte magistrale.

Alimentarea cu apa :
Alimentarea cu apa potabila se realizeaza de la reteaua orasului. Pe amplasament nu
exista bransament de apa in prezent.
Prepararea apei calde menajere se realizeaza cu ajutorul centralei termice. Modul de
alegere a echipamentelor pentru prepararea apei calde menajere este prezentat in proiectul
tehnic de instalatii termice.
Canalizare :
Apele uzate menajere colectate pana la nivelul subsolului sunt canalizate gravitational
catre reteaua de canalizare a orasului printr-un camin de racord amplasat la limita de
proprietate. Pe amplasament nu exista bransament in prezent. Va fi prevazut separatoare de
grasimi si de produse petroliere.
Apele meteorice, care provin din ploi sau din topirea zapezilor de pe acoperisul
cladirii, sunt evacuate cu ajutorul coloanelor la reteaua de preluare a apelor pluviale ale
municipiului.
Alimentarea cu energie termica :
Alimentarea cu energie termica se propune a se realiza prin intermediul unei centrale
termice tip pompa de caldura ce va asigura incalzirea si racirea spatiilor prin
ventiloconvectoare.
Alimentarea cu energie electrica :
In prezent exista retele ce vor asigura racordul imobilelor rezultate. Iluminatul stradal
este existent. Se va putea asigura iluminatul exterior al incintei si montarea unor panouri
fotovoltaice, functie de intentia investitorului in faza de proiect de tehnic.
Alimentarea cu gaze naturale :
In zona exista conducta de gaz metan din reteaua locala si exista posibilitatea racordarii
intregului ansamblu la reteaua de gaze a municipiului. Pe amplasament nu exista bransament
de gaze naturale.

3. CARACTERISTICILE CONSTRUCTIEI PROPUSE


pg. 3
 Pr. nr. : 80/2021
 Proiect. : CONSTRUIRE STATIE DISTRIBUTIE CARBURANTI, SPATIU COMERCIAL, ALIMENTATIE PUBLICA
SI SPALATORIE
 Beneficiar: S.C. LACUL VIOLET S.R.L.
 Faza: D.T.A.C.
Conform temei de proiectare solutia propusa consta in construirea unei benzinarii cu
spatii de vanzare si alimentatie publica (C1), a unei copertine unde se vor amplasa pompele
de alimentare cu carburant (C2), a unui totem de semnalizare/promovare publicitara (C3), a
unei spalatorii tip self-wash (C4), a unei platforme betonate pentru amplasarea
echipamentelor tehnice (C5), a unei statii de alimentare GPL (C6) si a unei pompe cu debit
marit pentru alimentarea tirurilor si a utilajelor mari (C7). Deasemenea se propune
amenajarea incintei cu spatii verzi si plantatii de protectie perimetrale, circulatii auto si
pietonale de incinta, parcari, statii de aspirare, statii de alimentare cu apa/aer si statii de
incarcare electrice auto.

CORP - C1
Functiune BENZINARIE
Regim de inaltime P
Inaltime minima la atic +3.80m
Inaltime maxima +5.50m
S.c. 780mp
S.c. desfasurata 780mp
S.u. totala 625.55mp
Nr. Maxim ocupanti 146 persoane
Volum 2342 mc
Numar delocuri la mese 132 locuri
Numar locuri de parcare – ALIMENTATIE 14 locuri
PUBLICA
Numar locuri de parcare – COMERCIAL 4 locuri
Categoria de importanta C
Clasa de importanta III

Distributia spatiilor propuse este urmatoarea :


Functiune Denumire spatiu Suprafata utila
PUBLIC TERASA ACOPERITA 120,00 mp
SPATIU VANZARE 96,00 mp
CURSIVA 81,00 mp
SALA MESE 140,00 mp
HOL 7,40 mp
G.S. BARBATI 10,70 mp
G.S. FEMEI 10,70 mp
G.S. DIZABILITATI 4,15 mp
ALIMENTATIE PUBLICA DEPOZIT BUCATARIE 13,60 mp
CAMERA FRIGORIFICA 5,40 mp
PREPARARI 5,60 mp
GRUP SANITAR 2,50 mp
VESTIAR 7,20 mp
BUCATARIE 40,00 mp
SPALATOR 3,70 mp
OFICIU SERVIRE 27,00 mp
DEPOZIT BAR 10,00 mp
BAR 10,00 mp
ADMINISTRATIE VESTIAR 2,40 mp
BIROU 7,10 mp
DEPOZIT FRIGORIFIC 8,65 mp
pg. 4
 Pr. nr. : 80/2021
 Proiect. : CONSTRUIRE STATIE DISTRIBUTIE CARBURANTI, SPATIU COMERCIAL, ALIMENTATIE PUBLICA
SI SPALATORIE
 Beneficiar: S.C. LACUL VIOLET S.R.L.
 Faza: D.T.A.C.
DEPOZIT 5,50 mp
HOL 4,55 mp
GRUP SANITAR 2,40 mp
TOTAL 625,55 mp
S.c.= 123mp ; S.u.= 625,55mp ; S.u.(fara terase)= 505,55mp

CORP – C2
Functiune COPERTNA
Regim de inaltime P
Inaltime minima la atic +5.10m
Inaltime maxima +6.30m
S.c. 270mp
S.c. desfasurata 270mp
S.u. totala 251.55mp
Nr. statii alimentare 6 statii
Nr. pompe 3 pompe
Categoria de importanta C
Clasa de importanta III

CORP – C3
Functiune TOTEM
Regim de inaltime P
Inaltime minima la atic +10.80m
Inaltime maxima +10.80m
S.c. 2.40mp
S.c. desfasurata 2.40mp
Categoria de importanta D
Clasa de importanta IV

CORP – C4
Functiune SPALATORIE
Regim de inaltime P
Inaltime minima la atic +3.20m
Inaltime maxima +3.80m
S.c. 215mp
S.c. desfasurata 215mp
S.u. totala 195mp
Numar boxe spalare 6
Numar statii aspirare 4
Numar locuri de parcare 6
Categoria de importanta C
pg. 5
 Pr. nr. : 80/2021
 Proiect. : CONSTRUIRE STATIE DISTRIBUTIE CARBURANTI, SPATIU COMERCIAL, ALIMENTATIE PUBLICA
SI SPALATORIE
 Beneficiar: S.C. LACUL VIOLET S.R.L.
 Faza: D.T.A.C.
Clasa de importanta III

Distributia spatiilor propuse este urmatoarea :


Functiune Denumire spatiu Suprafata utila
SPALATORIE BOXA 1 29,00 mp
BOXA 2 29,00 mp
BOXA 3 29,00 mp
BOXA 4 29,00 mp
BOXA 5 29,00 mp
BOXA 6 29,00 mp
CAMERA TEHNICA 21,00 mp
TOTAL 195,00 mp
S.c.= 215mp ; S.u.= 195mp

CORP – C5
Functiune PLATFORMA TEHNICA
Regim de inaltime P
Inaltime minima la atic --
Inaltime maxima --
S.c. 28mp
Categoria de importanta D
Clasa de importanta IV

CORP – C6
Functiune STATIE GPL
Regim de inaltime P
Inaltime minima la atic +2.70m
Inaltime maxima +3.30m
S.c. 27.40mp
Categoria de importanta C
Clasa de importanta III

CORP – C7
Functiune POMPA DEBIT MARE
Regim de inaltime P
Inaltime minima la atic +3.00m
Inaltime maxima +3.80m
S.c. 6.15mp
Categoria de importanta C
Clasa de importanta III

Imprejmuire :
Catre domeniile private (N, E si V) se va executa imprejmuire cu soclu de beton armat
si placi WPC.
Catre domeniul public nu se vor executa imprejmuiri.

Amenajari exterioare :
pg. 6
 Pr. nr. : 80/2021
 Proiect. : CONSTRUIRE STATIE DISTRIBUTIE CARBURANTI, SPATIU COMERCIAL, ALIMENTATIE PUBLICA
SI SPALATORIE
 Beneficiar: S.C. LACUL VIOLET S.R.L.
 Faza: D.T.A.C.
In cadrul incintei se vor amenaja urmatoarele:
Amenajari
DENUMIRE NUMAR
Locuri de parcare 22
Locuri pentru persoane cu dizabilitati 2
Statii de aspirare 4
Statie alimentare apa 1
Statie alimentare cu aer 1
Statii alimentare masini electrice 6

4. INDICI URBANISTICI SI REGLEMENTARI DE AMPLASARE


In urma efectuarii lucrarilor indicii cu privire la ocuparea terenului sunt:
TEREN N.C. 43907 Existent Propus
S. teren 5000 mp
S. construita 0.00 mp 1338,95 mp
S. constrita desfasurata 0.00 mp 1338,95mp
P.O.T. 0% 27,6%
C.U.T. 0.00 0.27
Suprafata amenajari exterioare 2661,05 mp
Suprafata spatii verzi 1000 mp

Distante:

Distante minime ale constructiilor propuse fata de limita de


proprietate
NORD EST SUD VEST
C1 34.54m 27.14m 10.00m 7.00m
C2 39.03m 11.88m 19.72m 21.12m
C3 90.77m 24.51m 0.40m 28.18m
C4 2.00m 7.66m 80.45m 3.99m
C5 2.00m 2.00m 80.31m 41.37m
C6 23.32m 12.77m 58.13m 25.91m
C7 47.84m 5.38m 36.12m 42.08m

Distante minime ale constructiilor propuse fata de cladirile invecinate: Grad de rezistenta la foc
NORD -- -- --
EST 15.02m HALA II
SUD -- -- --
VEST -- -- --

Bilant constructii/amenajari:
Tip Denumire Suprafata Procent
Cladiri Corp C1 780mp
Corp C2 270mp
Corp C3 2,4mp
Corp C4 215mp 27,6%
Corp C5 28mp
Corp C6 27.40mp
pg. 7
 Pr. nr. : 80/2021
 Proiect. : CONSTRUIRE STATIE DISTRIBUTIE CARBURANTI, SPATIU COMERCIAL, ALIMENTATIE PUBLICA
SI SPALATORIE
 Beneficiar: S.C. LACUL VIOLET S.R.L.
 Faza: D.T.A.C.
Corp C7 6,15mp
Amenajari Spatii verzi 1000mp 20%
Asfalt 2661,05mp 54%
TOTAL 5000mp 100%

5. SOLUTII CONSTRUCTIVE SI DE FINISAJ

Sistemul constructiv :
Este alcatuit din insfrastructura beton armat si suprastructura metalica . Structura
invelitorii va fi metalica.

Inchideri exterioare si compartimentari interioare :


Inchiderile exteriare vor fi realizate din panori tristrat, de 10-15 cm grosime. Peretii de
compartimentare vor fi din gips carton si panouri tristrat de 15/20/25 cm grosime.
Izolarea termica a cladirii se va asigura prin modul de alcatuire al elementelor
anvelopante.
Finisaje interioare :
Finisajele interioare ale constructiei propuse vor fi zugraveli cu vopsele lavabile,
placari cu lemn si metal, pardoseli din covor PVC (materialele fiind destinate traficului greu).
Grupurile sanitare vor primi deasemenea finisajele uzuale pentru astfel de spatii:
gresie pentru pardoseli si faianta pentru pereti. Se vor hidroizola toate baile si bucataria cu
un strat de emulsie bituminoasa la pardoseala.
Pardoseli :
Se vor folosi ca finisaje, la nivelul pardoselii, covor PVC si gresie.
In corpul C4 se vor folosi pardoseli din beton elicopterizat.
Pereti :
Pentru pereti se vor folosi vopsitorii lavabile si placari de lemn si piatra naturala, iar in
grupurile sanitare si spatiile bucatriei, placari ceramice si vopsitorii lavabile speciale pentru
spatii sanitare.
In grupurile sanitare se va placa cu material ceramic in zonele umede ( dus, lavoir, wc)
si in bucatarii se va placa ceramic in zonele de preparari, bucatarie calda, spalatoare, bucatarie
calda, de la cota 0,00m la cota +1,80.
Tavane :
Tavanele vor fi tavane false executate din gips carton pe schelet metalic finisate cu
vopsitorii lavabile.
Tamplarie :
Tamplaria in interior este realizata din usi celulare din MDF vopsit sau usi metalice
tehnice cu rezistenta la foc unde va fi cazul. Spre exterior, usile si ferestrele sunt realizate din

pg. 8
 Pr. nr. : 80/2021
 Proiect. : CONSTRUIRE STATIE DISTRIBUTIE CARBURANTI, SPATIU COMERCIAL, ALIMENTATIE PUBLICA
SI SPALATORIE
 Beneficiar: S.C. LACUL VIOLET S.R.L.
 Faza: D.T.A.C.
pereti cortina cu rama din aluminiu de culoare gri inchis, cu geam securizat si stratificat
realizat din 2 foi de sticla.
Finisaje exterioare :
Finisajele exterioare ale constructiei vor fi alcatuite din placari cu tabla sinus gri
deschis si alucobond alb.
Acoperisul si invelitoarea :
Invelitoarea va fi tip terasa necirculabila cu membrana PVC.
Colectarea apelor pluviale se face prin intermediul unor sifoane cu parafrunzar ce vor
transmite apele gravitational pana la reteaua de canalizare aflata in zona prin intermediul unor
coloane din PVC.

6. INDEPLINIREA CERINTELOR DE CALITATE (stabilite prin legea


10/1995)
In vederea realizarii calitatii constructiei in toate etapele de concepere, realizare,
exploatare si postutilizare a acesteia, se impune aplicarea sistemului calitatii prevazut in
Legea nr. 10/1995 privind calitatea in constructii. Sistemul calitatii se compune din:
 Reglementarile tehnice in constructii;
 Calitatea produselor folosite la realizarea constructiilor;
 Agrementele tehnice pentru noi produse si procedee;
 Verificarea proiectelor, a executiei lucrarilor si expertizarea proiectelor si
constructiilor;
 Conducerea si asigurarea calitatii in constructii;
 Autorizarea si acreditarea laboratoarelor de analize si incercari in activitatea
de constructii;
 Activitatea metrologica in constructii;
 Receptia constructiilor;
 Comportarea in exploatare si interventii in timp;
 Postutilizarea constructiilor;
 Controlul de stat al calitatii in constructii.

In conformitate cu Ordinul MDRAP nr. 2264/28.02.2018 pentru aprobarea procedurii


privind atestarea verificatorilor de proiecte si a expertilor tehnici in constructii,
beneficiarul va dispune la verificare documentatia la urmatoarele exigente:
 - A1 – rezistenta si stabilitate
 - C – siguranta la incendiu
 - D – igiena, sanatatea oamenilor, refacerea si protectia mediului
 - B1 – Siguranta in exploatare
 - F – protectia impotriva zgomotului
 - E – izolarea termica si economia de energie

Cerinta “A” rezistenta si stabilitate


pg. 9
 Pr. nr. : 80/2021
 Proiect. : CONSTRUIRE STATIE DISTRIBUTIE CARBURANTI, SPATIU COMERCIAL, ALIMENTATIE PUBLICA
SI SPALATORIE
 Beneficiar: S.C. LACUL VIOLET S.R.L.
 Faza: D.T.A.C.
Conform Normativ P100-1/2013 valoarea de varf a acceleratiei terenului pentru
proiectare, pentru cutremure avand intervalul mediu de recurenta IMR=225 ani, este ag=0.20,
iar perioada de control (colt) a spectrului de raspuns Tc=0.7sec.
Incadrarea in zona de vant, cu o presiune de 0.50 kN/mp, conform Codului de
proiectare, indicativ NP-082-04 cu modificarile din 17.08.2005;
Incadrarea in zona de zapada, cu o presiune de 2,50 kN/mp, conform Codului de
proiectare, indicativ CR 1-1-3-2005;
Adancimea de inghet se afla la 0.80-0.90 m de la nivelul terenului (Stas 6054 – 84).
In conformitate cu Normativul P100/2013, clasa de importanta a constructiilor este :
Denumire Functiune Clasa de importanta
Corp C1 BENZINARIE III
Corp C2 COPERTINA III
Corp C3 TOTEM IV
Corp C4 SPALATORIE III
Corp C5 PLATFORMA TEHNICA IV
Corp C6 STATIE G.P.L. III
Corp C7 POMPA DEBIT MARIT IV

In conformitate cu „Regulamentul privind stabilirea categoriei de importanta a


constructiilor”, aprobat prin H.G.R. nr.766 din 21.11.1997, categoria de importanta a
constructiilor este :
Denumire Functiune Categoria de importanta
Corp C1 BENZINARIE C
Corp C2 COPERTINA C
Corp C3 TOTEM D
Corp C4 SPALATORIE C
Corp C5 PLATFORMA TEHNICA D
Corp C6 STATIE G.P.L. C
Corp C7 POMPA DEBIT MARIT D

Proiectul de structura rezistenta si stabilitate va fi verificat la cerinta “A” de catre


verificatori de proiecte atestati.
Cerinta “C” securitatea la incendiu
NOTA1: In conformitate cu precizarile IGSU si Manualul indicativ MP 008-2000,
pentru spatiile si incaperile din cladirile civile (publice) mentionate la art. 2.1.3. din
Normativul P118-99, nu mai este necesara calcularea densitatii de sarcina termica, nivelul
riscului de incendiu fiind cel stabilit de normativ, in cazul nostru, la spatiul comercial –
RISC MARE DE INCENDIU, bucatarii, centrala termica – RISC MIJLOCIU DE
INCENDIU, celelalte spatii – RISC MIC DE INCENDIU.
NOTA2 : Calculul densitatii sarcinii termice se va efectua totusi pentru a se verifica
corelatia stabilita la art. 2.4.2. din Normativul P118-99 dintre rezistenta la foc a elementelor
de constructie care separa doua spatii si densitatea sarcinii termice din acestea, precum si

pg. 10
 Pr. nr. : 80/2021
 Proiect. : CONSTRUIRE STATIE DISTRIBUTIE CARBURANTI, SPATIU COMERCIAL, ALIMENTATIE PUBLICA
SI SPALATORIE
 Beneficiar: S.C. LACUL VIOLET S.R.L.
 Faza: D.T.A.C.
densitatea sarcinii termice determina incadrarea in riscuri inferioare sau superioare de
incendiu.
NOTA3 : Pentru holuri si grupuri sanitare nu este necesar calculul densitatii sarcinii
termice, aceasta fiind aproape nula, rezultand un RISC MIC DE INCENDIU.
- se va urmari in permanenta ca produsele/materialele depozitate/utilizate sa nu
depaseasca densitatea sarcinii termice estimata pentru spatiile luate in considerare.
- nu se vor bloca/obtura caile de acces si evacuare ;
- personalul propriu se va instrui permanent privind interventia in cazul unui
eventual incendiu, evacuarea personalului; periodic se vor organiza si desfasura exercitii de
interventie si evacuare ;
- in caz de incendiu se va intrerupe alimentarea cu energie electrica, gaze si se
va anunta Inspectoratul pentru Situatii de Urgenta, politia la nr. telefon 112, Enel etc.
Constructia, cu masurile prevazute in scenariul de siguranta la foc, indeplineste
criteriile minime si nivelurile de performanta privind siguranta la foc conform prevederilor
Normelor generale de psi, aprobate de OMAI cu ordinul 163/2007 si ale normativului P
118/99.
La intocmirea documentelor de organizare a apararii impotriva incendiilor vor fi
respectate prevederile urmatoarelor prevederi legale in vigoare.
Organizarea apararii impotriva incendiilor presupune:
a) stabilirea structurilor cu atributii in domeniul apararii impotriva incendiilor;
b) elaborarea, aprobarea si difuzarea actelor de autoritate: decizii, dispozitii,
hotarari si altele asemenea, prin care se stabilesc raspunderi pe linia apararii impotriva
incendiilor;
c) elaborarea, aprobarea si difuzarea documentelor si evidentelor specifice privind
apararea impotriva incendiilor;
d) organizarea apararii impotriva incendiilor la locurile de munca;
e) planificarea si executarea de controale proprii periodice, in scopul depistarii,
cunoasterii si inlaturarii oricaror stari de pericol care pot favoriza initierea sau dezvoltarea
incendiilor;
f) analiza periodica a capacitatii de aparare impotriva incendiilor;
g) elaborarea de programe de optimizare a activitatii de aparare impotriva
incendiilor;
h) indeplinirea criteriilor si a cerintelor de instruire, avizare, autorizare, atestare,
certificare, agrementare, prevazute de actele normative in vigoare;
i) realizarea unui sistem operativ de observare si anuntare a incendiului, precum si
de alertare in cazul producerii unui astfel de eveniment;
j) asigurarea functionarii la parametrii proiectati a mijloacelor tehnice de aparare
impotriva incendiilor;

pg. 11
 Pr. nr. : 80/2021
 Proiect. : CONSTRUIRE STATIE DISTRIBUTIE CARBURANTI, SPATIU COMERCIAL, ALIMENTATIE PUBLICA
SI SPALATORIE
 Beneficiar: S.C. LACUL VIOLET S.R.L.
 Faza: D.T.A.C.
k) planificarea interventiei salariatilor, a populatiei si a fortelor specializate, in caz
de incendiu;
l) analizarea incendiilor produse, desprinderea concluziilor si stabilirea
imprejurarilor si a factorilor determinanti, precum si a unor masuri conforme cu realitatea;
m) reglementarea raporturilor privind apararea impotriva incendiilor in relatiile
generate de contracte/conventii;
n) asigurarea formularelor tipizate, cum sunt permisele de lucru cu focul, fisele de
instruire.

Intocmit,
Arh. Cosmin Tudor VIZIREANU

pg. 12
 Pr. nr. : 80/2021
 Proiect. : CONSTRUIRE STATIE DISTRIBUTIE CARBURANTI, SPATIU COMERCIAL, ALIMENTATIE PUBLICA
SI SPALATORIE
 Beneficiar: S.C. LACUL VIOLET S.R.L.
 Faza: D.T.A.C.

S-ar putea să vă placă și