Sunteți pe pagina 1din 11

UNIVERSITATEA POLITEHNICA TIMISOARA

FACULTATEA DE CONSTRUCTII
DEZVOLTARE DURABILA












PROIECT
TERMOTEHNICA CONSTRUCTILOR







Prof. coordonator
Student
Conf.dr.ing. Silvana Brata Smeu Silvia Ioana
Master Dezvoltare Durabila AN I




2013




BORDEROU



A. PIESE SCRISE
1. Foaie de capat
2. Borderou
3. Memoriu tehnic justificativ
4. Breviar de calcul

B. PIESE DESENATE
1. Plan parter
2. Plan etaj
3. Sectiune verticala

MEMORIU TEHNIC JUSTIFICATIV



- Prezentarea generala a cladirii de locuit
- Cladirea este situata in Timisoara, judetul Timis.
- Construcia are funcia de LOCUIN COLECTIVA, cu regimul de
nlime P+4E.
- Cladirea are forma dreptunghiulara in plan, cu dimensiunile de
19.75mx9.75m.
- Inaltimea totala a constructiei este de 15.75 m


- Identificarea puntilor termice liniare
- colturile verticale (iesinde) formate la intersectia intre 2 pereti exteriori
ortogonali,
- puntile termice verticale de la intersectia peretilor exteriori cu pereti interiori
structurali,
- intersectia peretilor exteriori cu planseele intermediare in zona centurilor,
- placile continuie din beton armat care traverseaza peretii exteriori la balcoane,
-conturul tamplariei exterioare,
- intersectia peretilor exteriori si planseul sub terasa
- intersectia peretilor exteriori si placa pe sol.













BREVIAR DE CALCUL


Determinarea puntilor termice liniare:

- Zidarie structurala cu stalpisori. Colt perete iesind.





d = 25 cm
t = 10 cm
= 0.25 W/mK
=> = 0.073



- Zidarie structurala cu stalpisori. Intersectie perete exterior cu perete interior (in T).


d = 25 cm
t = 10 cm
= 0.25 W/mK
=> = 0.011

- Zidarie structurala cu stalpisori. Tamplarie, sectiune orizontala (tamplarie
lemn dubla)

d = 25 cm
t = 10 cm
= 0.25 W/mK
=> = 0.196





- Zidarie structurala cu stalpisori. Intersectia perete exterior cu planseu curent
(centura)



d = 25 cm
t = 10 cm
= 0.25 W/mK
=>
1
= 0.014 ;
2
= -0.005.









- Zidarie structurala cu stalpisori. Intersectia perete exterior cu placa balcon.




d = 25 cm
t = 10 cm
= 0.25 W/mK
=>
1
= 0.284;
2
= 0.197




- Zidarie structurala cu stalpisori. Intersectia perete exterior cu planseul sub
terasa.

d = 25 cm
t = 10 cm
t = 20 cm
= 0.25 W/mK
=>
1
= 0.144;
2
= 0.347

















- Zidarie structurala cu stalpisori. Intersectia perete exterior cu placa pe sol.

= 0.25 W/mK
=> = 0.48;















Determinarea *l. Corectarea rezistentelor termice

- Puntile termice pe perete dinspre N
A
l R
r

+
=
) * ( *
1
1


(*l)=[2*(0.073*15.3)+8*(0.011*15.3)]+[20*(0.196*1.5)+20(0.196*0.6)+
20*(0.196*0.6)+20*(0.196*1.2)]+[4*(0.014*19.25)+4(-0.005*19.25)]= 19.56
1
0.81
3.46*19.56
1
294.53
r = =
+


- Puntile termice pe perete dinspre S
A
l R
r

+
=
) * ( *
1
1


(*l)=[2*(0.073*15.3)+8*(0.011*15.3)]+[60*(0.196*1.2)+5*(0.196*1.6)+
4*(0.196*0.6)+2*(0.196*1.8)+8*(0.196*1)+8*(0.196*0.8)+9*(0.196*2.1)]+
[4*(0.014*19.25)+4(-0.005*19.25)]+ [8*(0.284*4.25)+8*(0.197*4.25)]= =44.01

1
0.65
3.46*44.01
1
294.53
r = =
+


- Puntile termice pe perete dinspre E
A
l R
r

+
=
) * ( *
1
1


(*l)=[2*(0.073*15.3)+2*(0.011*15.3)]+[4*(0.014*9.25)+4*(-0.005*9.25)]=2.9

1
0.93
3.46*2.90
1
141.53
r = =
+







- Puntile termice pe perete dinspre V
A
l R
r

+
=
) * ( *
1
1


(*l)=[2*(0.073*15.3)+2*(0.011*15.3)]+[4*(0.014*9.25)+
4*(-0.005*9.25)]=2.90

1
0.93
3.46*2.90
1
141.53
r = =
+


- Puntile termice la planseul sub terasa
A
l R
r

+
=
) * ( *
1
1


(*l)=(0.144*57)+(0.347*57)=27.99

1
0.52
5.92*27.99
1
178.06
r = =
+


- Puntile termice la placa pe sol
A
l
T
T
R R
p
+
A
A
=
) * (
*
1
'
1
1


(*l)=0.48*57=27.36
'
1 2
1
1 2
1 1 10 27.36
* 5.31
' 8.30 35 178.06
20
15
10
1
6
p i p
i e
i
e
p
R
R
T T T
T T T
T C
T C
T C
dp z f dp d
R
p p
f d
_
-
-
-
= + => =
A =
A =
=
=
=
+ +
= + + +
=


m dp 3
1
=
m dp 4
2
=
mK W p / 2
1
= _
mK W p / 4
2
= _
Z=0.60m
f=0.45m
1
1 3 0.6 0.45 4
5.56 8.30
6 2 4
R
+
= + + + =
5.31
0.64
8.30
r => = =

Rezistenta termic medie pe cldire

] / [
* ' *
'
2
W K m
U Aj
Aj
R
j j
med
t

j
t factorul de corecie a temperaturilor exterioare
e i
j i
j
T T
T T

= t


T
e
temperature exterioar convenional de calcul pentru perioada rece a anului, care
se consider n conformitate cu harta de zonare climatic a teritoriului Romniei,
pentru perioada de iarn, din anexa D din [1], astfel:
Zona II T
e
= -15
o
C
T
i
temperature interioar convenional de calcul pe timpul iernii, care la cldirile de
locuit se consider temperature predominant a ncperilor:
T
i
= +20
o
C
T
j
temperatura n mediul din exteriorul anvelopei care poate fi:
T
j
= T
e

1 t => =


Calculul rezistentei specifica medie a peretiilor

2
(294.53 294.53 141.53 141.53)
1
'
1 1 1 1
' ( * ' * )
(294.53* 294.53* 141.53* 141.53* )
2.80 2.25 3.22 3.22
' 2.69[ / ]
m
m j
m
Aj
R
U Aj U j
R m K W
t
+ + +
= = =
+ + +
=




Aj=aria fiecarui perete pe orientari.
U
j
=1/R
R r R *
'
=
' 2
0.81*3.46 2.80[ / ]
N
R m K W = =
' 2
0.65*3.46 2.25[ / ]
S
R m K W = =
' 2
0.93*3.46 3.22[ / ]
VE
R m K W = =



' 2
0.52*5.92 3.07[ / ]
t
R m K W = =
' 2
0.64*5.73 3.67[ / ]
ps
R m K W = = .

S-ar putea să vă placă și