Documente Academic
Documente Profesional
Documente Cultură
CAP. 3. LACUL DE
ACUMULARE
CAP.3. LACUL DE ACUMULARE
3.1. Definiţie, clasificări, funcţiuni
Z [mdM]
Sk
Zk
Z1 Z=ct.
Zk Z0
Z3
Z2
Z1
Z0 S1S2 S3 Sk S [mii mp, ha,
kmp]
CAP.3 LACUL DE ACUMULARE
3.2. Curbe caracteristice ale lacurilor de acumulare
480
90.00 mil mc
475 Volum de atenuare
473.00 Nivel minim energetic f` r` restric\ii
470 470.00 Nivel minim energetic cu restric\ii
Prag priz` central` 190.00 mil mc Volum de atenuare
465 Volum util f` r` restric\ii 890.00 mil mc
V= 1351.00 mil mc
V= 1220.00 mil mc
460 Volum util cu restric\ii 926.00 mil mc
Volum de rezerv` de fier 36.00 mil mc
V= 204.00 mil mc
455
V= 1030.00 mil mc
V= 240.00 mil mc
V= 1000.00 mil mc
V= 1130.00 mil mc
450
445
440
435
433.00 Prag goliri de fund 433.00 434.25 mdM
Ax goliri
430 204.00 mil mc Volum mort mdM
50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250 V (mil mc)
200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 S (ha)
8.00 mil mc Volum neevacuabil
196.00 mil mc Volum evacuabil sub nivelul prizei
CAP.3 LACUL DE ACUMULARE
3.3. Parametrii caracteristici ai lacurilor de
acumulare
⚫
acumulare) se extinde pe ani, sezoane, luni,
săptămâni sau zile şi căteodată poate fi şi orară.
În funcţie de coeficientul de acumulare,
Wan = Qmm Tan
regularizarea debitelor poate fi:
⚫ zilnic – orară: acoperă vârfurile de dimineaţă şi de
seară, realizând acumulări în golurile de zi şi de
noapte ale graficului zilnic de sarcină;
⚫ săptămânală;
⚫ sezonieră;
⚫ anuală: compensează sezoanele între ele,
asigurând acumularea în lac primăvara pentru a
uzina iarna;
⚫ multianuală: compensează anii ploioşi, normali şi
secetoşi, acumulează în anii ploioşi pentru a uzina
în cei secetoşi fără a fi nevoie să se golescă lacul.
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor
a=
V u
Vu
în care Vu poate fi volumul util pentru următoarele trei cazuri:
⚫ - zilnică: a = 0,5 ... 1,0;
⚫ - săptămânală: a = 20 .... 52;
⚫ - anuală: a = 100 .... 365.
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor
(Qa1t1 + V01 )(hm ( 01) + hdn ) + (Qa 2 t 2 + V12 )(hm (12) + hdn ) + ...
+ (Qan t n + Vn −1,n )(hm ( n −1),n + hdn ) = (QG t G + V0,n )(k LG hOm) + hdn )
⚫ Unde Qa1, Qa2, ... , Qan – debitul mediu afluent pe intervalele de timp
t1, t2, ... , tn;
⚫ QG – debitul mediu al întregii perioade de golire având durata tG = t1
+ t2 + ... + tn;
⚫ Intervalele de timp ti sunt alese astfel încât atât debitul afluent cât şi
cel prelevat să nu varieze foarte mult, putând fi considerate constante.
⚫ Dacă t1 = t2 =....= tn, Qa1 = Qa2 =....= Qan şi V01 = V02 =...=V0n,
atunci kLG = 1.
⚫ Similar, se determină şi coeficientl kLU pentru perioada de umplere a
lacului.
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor
Va = Q ai (t i − t i −1 ) = Q ai t i
unde Qa este debitul mediu afluent şi Qai este debitul mediu afluent în intervalul de
timp (ti-ti-1).
⚫ Relaţia de mai sus se utilizează în momentul în care se calculează curba integrală
a debitelor pe intervale egale de timp, de genul lună, săptămâna sau zi.
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor
Dezavantaje:
⚫ dacă T este foarte mare şi este de ordinul anilor, valorile V fiind crescătoare, cresc
spre valori foarte mari şi deci intervalul de variaţie al lui V între 0 şi V este foarte
larg şi în cazul reprezentării grafice este nevoie de o scară foarte mică.
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor
8 36.50 15.30 8.71 34.40 51.40 79.40 21.90 9.18 5.81 5.14 10.40 14.10 24.35
9 13.50 11.50 5.00 7.53 19.50 41.30 28.50 12.90 8.82 4.96 22.00 14.20 15.81
10 10.00 8.71 7.90 34.90 21.20 6.54 4.22 3.81 3.26 5.03 29.40 26.20 13.43
11 10.60 7.36 13.40 30.50 42.70 20.10 16.70 15.70 5.30 6.39 4.65 15.30 15.73
12 4.76 7.02 8.41 37.90 27.70 15.90 8.41 5.39 4.52 9.84 12.00 17.40 13.27
13 15.80 9.68 11.20 39.40 49.40 61.10 16.00 9.75 7.91 5.15 2.61 3.35 19.28
14 3.80 3.94 7.45 11.50 51.40 37.00 11.60 8.41 5.25 7.91 9.92 12.30 14.21
15 9.92 9.92 20.10 24.20 71.90 22.00 23.00 14.00 12.50 0.00 0.08 0.00 17.30
16 8.22 9.77 6.66 29.20 59.50 31.40 17.00 9.61 6.08 5.17 5.28 6.98 16.24
17 5.46 10.10 18.90 46.40 27.50 22.90 18.20 11.50 7.78 5.76 15.40 15.40 17.11
18 9.31 8.15 7.72 18.00 59.70 19.20 16.60 7.16 4.50 3.72 6.93 8.22 14.10
19 5.01 4.39 6.61 12.80 25.90 21.70 15.50 17.90 9.32 5.83 7.97 7.45 11.70
20 6.20 8.41 10.70 20.50 45.70 33.20 26.40 16.40 6.67 5.79 15.60 39.40 19.58
21 10.30 2.00 5.83 15.20 34.10 44.40 14.10 8.98 4.89 6.57 23.60 8.63 14.88
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor
22 6.58 6.20 17.60 40.70 50.80 23.00 12.30 8.43 5.88 4.64 10.20 6.83 16.10
23 5.57 6.65 7.73 24.70 41.80 21.10 10.40 8.07 7.63 5.68 4.55 4.28 12.35
24 3.31 3.39 4.90 12.00 17.40 10.70 10.30 10.20 5.84 33.20 18.00 16.90 12.18
25 10.40 7.69 12.40 16.90 78.70 35.60 9.49 5.60 5.20 4.75 3.61 4.65 16.25
26 3.12 10.30 5.82 24.30 31.80 17.50 19.30 17.20 10.70 5.83 18.30 8.72 14.41
27 6.27 4.94 8.10 27.50 62.10 39.20 20.50 8.63 8.11 5.68 5.73 5.73 16.87
28 6.50 6.52 7.77 31.80 31.10 11.30 8.89 19.70 17.40 9.41 14.30 9.32 14.50
29 6.86 10.80 11.80 25.70 53.90 41.90 43.70 13.30 9.84 5.70 7.77 20.50 20.98
30 13.70 8.89 15.50 56.90 69.10 48.80 31.80 11.70 5.82 5.43 5.20 3.95 23.07
9.31 8.66 10.25 25.77 43.57 33.60 17.06 10.29 8.14 8.36 11.30 13.32 16.64
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor
1 -21.07 -44.58 -69.58 -16.86 65.57 146.15 232.78 231.90 276.75 277.18 261.84 244.40
2 222.84 198.85 172.53 152.04 221.85 627.52 605.33 579.71 550.34 520.55 489.03 461.13
3 428.97 395.98 362.14 339.18 356.96 364.22 352.56 322.90 295.48 263.53 231.51 202.32
4 171.74 159.03 140.75 201.37 289.05 311.03 306.73 289.55 269.12 353.38 373.00 353.74
5 332.47 312.11 289.08 291.87 461.02 454.62 427.06 399.03 377.60 359.21 349.66 349.30
6 348.68 334.40 325.10 347.08 376.42 366.87 336.05 300.90 268.45 232.88 234.63 279.21
7 278.33 305.30 338.06 332.18 313.43 303.87 288.80 264.39 241.78 211.65 197.10 281.89
8 334.09 330.58 309.75 356.43 447.79 612.74 626.57 606.98 578.53 548.32 531.93 525.26
9 517.02 503.53 472.95 449.02 456.54 521.36 552.54 542.72 522.18 491.50 505.59 499.19
10 481.75 460.92 437.96 485.96 497.96 471.43 438.80 405.09 369.94 339.44 372.98 398.12
11 382.25 357.88 349.37 385.81 454.30 463.41 463.58 461.12 431.33 404.40 372.90 369.39
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor
12 338.18 312.91 291.29 347.17 376.25 374.32 352.70 323.14 291.30 273.44 261.26 263.27
13 261.07 242.79 228.51 288.33 374.43 491.28 489.61 471.52 448.59 418.40 381.54 346.63
14 312.89 279.53 255.39 241.89 333.25 386.77 373.53 351.91 321.99 299.06 281.41 270.02
15 252.37 234.72 243.82 263.70 408.93 423.03 439.76 432.83 421.96 378.24 334.73 291.01
16 268.89 250.85 224.63 257.65 370.30 409.10 410.06 391.59 363.85 333.72 303.88 278.50
17 249.13 231.95 237.90 316.12 344.67 361.14 365.25 351.75 328.48 299.89 296.65 293.40
18 274.15 251.84 228.41 232.00 345.17 351.91 351.81 326.91 295.02 261.08 235.57 213.45
19 182.90 150.72 124.37 114.29 138.63 151.94 148.96 152.28 133.05 104.65 81.88 57.74
20 30.31 8.70 -6.90 3.25 79.63 123.16 148.82 148.20 122.01 93.51 90.79 150.61
21 133.96 95.50 67.10 63.33 109.22 182.18 175.52 155.40 124.53 98.08 116.38 95.34
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor
22 68.91 41.49 44.02 107.26 197.05 213.77 202.38 180.81 152.54 121.02 104.11 78.34
23 49.25 23.01 -0.39 20.80 86.93 98.66 82.27 59.76 36.09 7.30 -24.46 -56.93
- - - - - - - - - - -
24 -91.95 126.76 157.60 169.79 167.78 183.38 200.03 216.94 245.31 201.78 198.20 197.50
- - - - - - -
25 -213.89 237.40 248.53 247.84 -84.74 -34.90 -53.68 -82.68 112.73 143.97 178.20 209.70
- - - - - - - - - - -
26 -245.22 261.87 290.30 270.15 230.30 228.03 221.03 219.55 235.15 263.55 259.17 279.98
- - - - - - - - - - -
27 -307.22 337.96 360.39 331.84 212.36 153.06 142.90 163.94 186.35 215.14 243.80 272.46
- - - - - - - - - - -
28 -299.10 325.68 348.98 309.13 271.12 285.14 305.50 297.45 295.44 314.43 320.57 339.80
- - - - - - - - - - -
29 -365.49 380.82 393.53 369.71 271.78 205.39 134.26 143.03 160.89 189.63 212.93 202.77
- - -
30 -210.49 230.85 233.83 128.02 9.86 94.39 134.24 121.27 92.84 63.39 33.34 0.00
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor
800
600
400
200
DV
0
0 12 24 36 48 60 72 84 96 108 120 132 144 156 168 180 192 204 216 228 240 252 264 276 288 300 312 324 336 348 360
-200
-400
-600
T[luni]
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor
Graficul dispecer
⚫ Modul de exploatare a acumulărilor determină regimul puterilor şi energiilor
produse de centralele hidroelectrice şi condiţiile în care se pot asigura
consumatorii cu apă din aval.
⚫ Exploatarea acumulărilor se poate schimba de la o perioadă la alta, în funcţie de
priorităţile economice ale perioadei respective. Astfel, de exemplu, din punct de
vedere energetic, se poate stabili o exploatare a acumulărilor cu menţinerea
nivelelor în lac la cote superioare (evitându-se însă deversările). În acest mod se
renunţă însă la rolul regularizator al acumulărilor. Din cauza căderilor mari ce se
realizează, rezultă cantitatea maximă a energiei ce se poate produce, dar cu o
repartiţie necontrolată în cursul anului, energia fiind produsă conform regimului
debitelor afluente (multă în perioada de ape mari de primăvară şi puţină în
semestrul de iarnă). În cazul în care în Sistemul Energetic Naţional sunt dificultăţi
în acoperirea vârfului de iarnă, poate apare necesară o exploatare a acumulărilor,
care să asigure maximum de transfer de apă din perioada de ape mari către
perioada de iarnă. În acest mod se produce o cantitate mai mare de energie în
perioada de iarnă, dar datorită variaţiilor mari ale nivelului lacului de acumulare
rezultă căderi mai mici şi pe total an, se obţine o producţie de energie mai redusă
faţă de cazul precedent.
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor
⚫ Graficul dispecer are două delimitări importante situate una pe ramura extremă şi
care are rolul de a îngheţa debitele pe limita anului extrem în cazul în care
volumul se situează sub ramură, iar cealaltă pe ramura ploioasă şi are rolul de a
îngheţa debitele regularizate pe această ramură în cazul în care volumul tinde să
depăşească respective treaptă superioară.
⚫ Planul de exploatare care urmează în general după elaborarea unui grafic
dispecer are rolul de a demonstra aplicabilitatea graficului dispecer în cazuri
concrete cu rezultate care-i demonstrează eficienţa.
⚫ În exploatarea unei centrale hidroelectrice cu lac de acumulare cu regularizare
anuală sau multianuală, pentru maximizarea energiei produse este obligatorie
utilizarea unui grafic dispecer în optimizarea folosirii cât mai eficiente a lacului de
acumularea aferent.
⚫ Transferul de stoc multianual permite o producţie de energie relativ bună chiar şi
în anii deficitari din punct de vedere hidrologic, în special asigurarea unui stoc în
lac pentru cazurile în care este necesară completarea afluentului care variază de
la an la an.
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor
⚫ Astfel, ramurile din semestrul de vară sunt poziţionate, pe ani hidrologici, mai sus decât în
semestrul de iarnă, în conformitate cu politicile de exploatare fundamental diferite în cele două
situaţii: vara se urmăreşte umplerea cât mai pronunţată a lacului chiar şi în situaţii hidrologic
dificile; iarna se urmăreşte o utilizare raţională a volumului acumulat, pentru a completa
corespunzător afluxul natural, variabil de la an la an. Cu cât rezerva de volum acumulată în
semestrul de vară este mai mare, cu atât sunt mai mari disponibilităţile de consum de apă în
semestrul de iarnă.
Un exemplu de utilizare a graficului dispecer este următorul:
⚫ avem un grafic dispecer ca în figura de mai jos;
⚫ presupunem că suntem în luna aprilie şi avem la început de lună, un volum în lac de cca 54
mil.m3;
⚫ dacă ducem o linie orizontală pentru volumul 54 mil.m3, se observa că aceasta se situează pe
curba corespunzătoare anului secetos;
⚫ debitul uzinat citit pentru punctul respectiv este de 3,7 m3/s;
⚫ acesta este primul debit uzinat considerat de referinţă în planul de exploatare;
⚫ acest debit poate fi uşor modificat în plus sau minus, în funcţie de debitul afluent în acea lună
în lac şi de condiţiile care se pun într-un plan de exploatare (să nu se depăşească volumul util
la sfârşit de lună, să nu se depăşească debitul instalat după corecţia sa privind evitarea
deversărilor etc.).
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor
Planul de exploatare
⚫ Planul de exploatare al unei amenajări este practic simularea exploatarării atât a
lacului de acumulare cât şi a centralei (centralelor) hidroelectrice. Planul de
exploatare ţine seama de toate condiţiile care se cer pentru o exploatare optimă şi
calculează energia medie posibil a fi produsă de o amenajare hidroelectrică.
⚫ Planul de exploatare se aplică atât amenajărilor care nu sunt încă construite,
pentru a calcula producţia de energie posibilă pentru respectiva amenajare şi a
stabili eficienţa viitoarei amenajări, cât şi în cazul amenajărilor în funcţiune, dar
care necesită modernizare, pentru a putea calcula eventualele beneficii care ar
putea apare în urma modernizării amenajării şi a se stabili eficienţa modernizării.
Modul de calcul al unui plan de exploatare, în cazul unei amenajări noi, este
următorul:
⚫ se stabileşte perioada caracteristică din punct de vedere hidrologic, cu şirul de ani
aferent;
⚫ se stabilesc intervalele de timp pe care se va aplica calculul (dacă sunt debite
afluente lunare, intervalul va fi o lună, dacă sunt zilnice, intervalul va fi o zi etc.);
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor
CAP.3 LACUL DE ACUMULARE
3.4. Regularizarea debitelor