Sunteți pe pagina 1din 4

n 7

Nmed 271.500 m SUPRAFETE Inainte de barare


Nmax 274.200 m
Vms 1.05
ALBII tronson supraf.
T8'-9 30.48
T9-10 104.00
T10-11 90.84
MS
T11-12 147.25 QMS = ΩMS*VMS 741.8303
T12-13 326.62
T13-13' 7.32 706.51
T13'-14 470.72
T14-15 452.47 Vm 1.25
T15-16 250.92
m
T16-17 285.03 VMD 1.1
T17-18 281.93
T18-18' 308.84 2049.91 Qm=Ωm*Vm 2562.388
T18'19 76.20
T19-20 171.33
MD T20-21 117.13
T21-22 63.36
T22-22' 28.13 456.15 QMD =ΩMD*VMD 501.765
3078.09 3212.57
Q= 3805.983
dupa barare

ALBII tronson supraf.


CS-11 90.84 ωbS=ΩMS-ωMS 169.81
T11-12 147.25
MS
T12-13 326.62
T13-13' 7.32 572.03 ωbD=ΩMD-ωMD 28.13
T12'-13 470.72
T14-15 452.47
T15-16 250.92 Qbs=ωbS*VMS 178.2955
m
T16-17 285.03
T17-18 281.93 QbD=ωbD*VMD 30.943
T18-18' 308.84 2049.91
T18'19 76.20 Qb=QbS+QbD 209.2385
T19-20 171.33
MD
T20-21 117.13
T21-CD 63.36 428.02
3049.96 3049.96
1. Calculul ariilor inainte de bararea cursului apei :
ΩMS Ωm ΩMD
572.025 2049.910 456.150
2. Calculul debitelor inainte de barare :
QMS Qm QMD
600.6263 2562.3875 501.7650
VMS Vm VMD
1.05 1.25 1.1
Q 3664.77875

3. Calculul ariilor dupa bararea cursului apei :

ωMS ωm ωMD
572.025 2138.180 428.020
4. Calculul ariilor barate :
ωbS 253.770
ωbD 28.130

5. Calculul debitelor barate :


QbS QbD Qb
266.459 30.943 297.402
6. Calculul coeficientilor de ingustare datorati pilelor si al coeficientului de contractie al curentului :
lMS lm lMD
72.8281 48.1063 47.8709
σMS σm σMD
0.027 0.040 0.040
b 2 ε 0.85

7. Calculul ariilor dupa barare,reduse cu ajutorul coeficientilor de ingustare si de contractie


a curentului ca urmare a pozitionarii pilelor in albia raului : εMS 0.827
ω'MS ω'MD ω'M ω'm εMD 0.816
473.2255639 349.2266477 822.4522116 1744.909108 εm 0.816

8. Calculul debitului dupa bararea cursului de apa :


Q'm Q'MS Q'MD Q' Q 3664.779
2764.51666 388.9858979 511.2761924 3664.779 Q' 3664.779
Q=Q'

S-ar putea să vă placă și