Sunteți pe pagina 1din 18

PROIECT METAL - PARTEA II

DETERMINAREA EFORTURILOR DIN GRUPARILE DE


ÎNCARCARI

STAS 10101/01 – 78

A) Gruparea fundamentala :
 Treapta superioara a stâlpului :
Secţiunea III – III
Mmax1=1.1*I1+0.8*(1.2*I3+1.3*I4+1.2*I5) =
= 1.1*13+0.8*[1.2*(-88.44)+1.3*(-118.9)+1.2*(-11.92)]=
=- 205.7 kNm
Mmax 2= 1.1*13+0.8*[1.2*88.44+1.2*141.2]= 234.75 kNm

Mmax=max (Mmax1;Mmax2)=234.75 kNm


Taf =1.1*2.89+0.8*(1.2*19.65+1.3*68.9)=93.7 kN
Naf =1.1*89.37 = 98.3 kN
Secţiunea II-II
Mmax=1.1*(-19.7)+0.8*[1.2*(-239.02)+1.3*(-118.9)+1.2*(-11.92)]=
=-386.3 kNm
Taf =1.1*2.89+0.8*[1.2*19.65+1.3*68.9]=100 kN
Naf =1.1*89.37+0.8*(1.2*436.6)=517.44 kN
Secţiunea I-I
Mmax=1.1*2.7+0.8*[1.2*(-124.2)+1.3*(-313.9)+1.2*(-233.2)]=
=-666.59 kNm
Taf =1.1*2.89+0.8*[1.2*19.65+1.3*68.9]=93.7 kN
Naf =1.1*124.24+0.8*[1.2*436.6]=555.8 kN
B) Gruparea specială
Mmax=I1+0.4*I2+0.6*I3+I6=2.7+0.4*0+0.6*(-124.2)+(-436)=507.82 kNm
Taf =2.89+0.6*19.65+35.6=50.28 kN
Naf =124.24+0.4*261.34+0.6*436.6=490.73 kN

CALCULUL CONTRAVÂNTUIRILOR ORIZONTALE LONGITUDINALE

Rw = ½*Pw*l/2* hstr=1/2*0.60*11.1/2*12.25=20.39 kN
VA=VB=Rw/2=10.2 kN
DIMENSIONAREA STÂLPULUI CADRULUI TRANSVERSAL

Stabilirea lungimilor de flambaj conform STAS 10108/0-76 -punctul 6.4.4


 În planul cadrului transversal
l = μ1 * Hi=1.39*7.75=10.77m
l = μ2 * Hs=1.74*4.5=7.83 m
 Perpendicular pe planul cadrului transversal
l = Hi=7.75 m
l = Hs=4.5 m
Coeficienţii μ1, μ2 se adoptă conform STAS 10108/0-76, tabel 22
În cazul în care : Hs/Hi 0.6 şi PA/PB 3
Hs/Hi=4.5/7.75=0.58<0.6; PA/PB =485.57/301.74 =1.61 ;Ii/Is=5
Unde: PA =P2+P4+Vmax =13.5+35.47+436.6=485.57 kN
Forţa axială care acţionează la nivelul treptei stâlpului
PB =P1+P5 =40.4+261.34=301.74 kN
Forţa axială ce acţionează pe capătul superior al stâlpului
c1=Hs/Hi*[Ii/(Is*c)]exp1/2=0.58*[5/2.61]exp1/2=0.80
c= (PA+PB)/PB=2.61
μ1={[(c-1)* μ + μ ]/c}exp1/2={1.61*1.02²+1.85²)/2.61}exp1/2=1.39
μ2= μ1/c1<3
μ2=1.39/0.8=1.74
Dimensionarea treptei superioare a stâlpului

Secţiunea III-III
Ipoteze de calcul:
 Dimensionarea se va face luând în calcul eforturile rezultate din
încărcarea cea mai defavorabilă pentru combinaţia de încărcări :
Mmax = 234.75 kNm
Naf = 98.3 kN
Taf = 93.7kN
Predimensionarea secţiunii
λx = l /i =l /(αX*h )=7830/(0.45*800)=21.75
h =bs=800 mm
b=l /( αy * λx)=4500/0.25*21.75=828 mm
Unde αX, αy sunt coeficienţii razelor de giraţie
αX = ix/hi=(0.40-0.45)=0.45
αy = iy/b=(0.22-0.26)=0.25

ρx=Wx/A=2* αX *hi=2*0.45²*800=32.4
e = Mmax/Naf =234.75/98.3=2.38m=239 [cm]
e/ρx =239/32.4=7.4
,λx=21.75
φx=0.17 -Anexa 12.3 Construcţii metalice Siminea
Anec =Nmax/ (φex*R)=261.34*10³/(0.17*210)=7320 mm²=73.2 cm²
ti h /100 =800/100=8 mm
OL 37 R= 2100 daN/cm
Rf=1300 daN/ cm
Se propune secţiunea treptei superioare a stâlpului având următoarele
caracteristici:
 h = h + 2*t=800+2*15=830 mm
 b =250 mm
 t = 15 mm
 ti = 10 mm
 A=2*b*t+ h *ti=2*250*15+800*10=15500mm²=155 cm²
 Ix = Ixi+2*Ixt+2*At*y²gt=10*800³/12+2*(250*15³/12+250*15*408²)=
=1.675*10 mm
 Iy =Iyi+2*Iyt=800*10³/12+2*15*250³/12=0.039*10 mm
 ix = = =328.73 mm

 iy= = =50.16 mm
 Wx = Ix/ymax =1.675*10 /415=4.03*10 mm³
 Wy = Iy/xmax =0.039*10 /125=0.312*10 mm
-Verificarea condiţiei de zvelteţe
λx,y=l /i λa=120
λx=7830/328.73=23.82<120
λy=4500/50.16= 89.7 <120
φx=0.987
φy=0.689
-Verificarea condiţiei de rezistenţă
materialul OL 37 R =2100 daN/cm
Rf=1300 daN/cm
σ=Naf/A+Mmax/Wx=98.3*10³/155*10²+234.75*10 /4.03*10 =
=64.59 N/mm² R=210 N/ mm²
σ=Nmax/A+Maf/Wx=350.71*10³/155*10²+234.75*10 /4.03*10 =
=80.87N/mm² R=210 N/ mm²
τ=Tmax/(h *ti)=93.7*10³/(800*10)=11.71 Rf=130 N/mm²
Verificarea condiţiei de rezistenţă în dreptul legăturii dintre inimă şi talpă
σ=Naf/A+(Mmax/Ix)*φ=98.3*10³/155*10²+(234.75*10 /1.675*10 )*400=
=62.4 N/ mm²<210N/ mm²
φ=h /2=800/2=400
σech= = =65.6 N/ mm² 1.1*R=1.1*210=231 N/
mm²
τ=Taf/((h *ti)=11.71 N/ mm²
Verificarea stabilităţii generale a secţiunii
σ=N/( φ*A)+cx*Mx/{ φg*(1+σ/σE)*Wx}=
=98.3*10³/(0.689*155*10²)+0.548*234.75*10 /{0.83*(1-6.34/3598.3)*
* 4.03*10 =47.73 N/mm²
în care:
N=Naf=98.3*10³N/ mm²
φ=min{ φx, φy}=min{0.987;0.689}=0.689
cx= 0.548 STAS 10108/0-78 Tabel (M2/M1=0)
Mx=Mmax=234.75*10 Nmm
φg= 0.830 coeficient în funcţie de λtr
λtr=μ *l/iy=0.7*4500/50.16=62.8
l=Hs=4500mm
μ=0.7
iy= 50.16 mm raza de inerţie a tălpii mai comprimate în raport cu y-y
σ=Naf/A=98300/15500=6.34 N/mm²
σE=3598.3 N/mm² efortul critic de flambaj Tabel STAS 10108/0-78 în funcţie
de λx ( λx=23.82 )
Verificarea stabilităţii locale a tălpilor
b /t =120/15 = 8 k1 =14
b =(b-ti)/2=(250-10)/2 =120 mm
k1= 14 Tabel STAS 10108/0-78
Verificarea stabilităţii locale a inimii
Eforturi unitare la extremităţile inimii
σ =Naf/A-(Mmax/Ix)*(h /2)=
=98.3*10³/155*10²- (234.75*10 /1.675*10 )*(800/2)=
=6.34-56.06=-49.72N/mm²
σ =Naf/A+(Mmax/Ix)*(h /2)=
= 98.3*10³/155*10²+(234.75*10 /1.675*10 )*(800/2)=
=6.34+56.06=62.4 N/mm²
Ψ=(σ-σ )/σ=(-49.72-62.4)/(-49.72)=2.255 1 h0/ti=800/10=80 100*
=

=100* =110.75
Nu este necesarărea longitudinală
k3=450 Tabel
β=0.07*τ*k3/σ =0.07*11.72*450/62.4=5.9
τ=Taf/(h *ti) =11.71 N/ mm²

Rigidizarea treptei superioare


h /ti=80>70* =70* =70
se prevăd rigidizări transversale pe inima treptei superioare
R=21 daN/mm²
h0=h =800 mm
tr= 8 mm grosimea rigidizărilor
tr =120/15=8
tr>0.75*ti =0.75*10 =7.5 mm Se ia: tr = 8 mm
br>10*ti =100mm Se ia: br=120mm
d=(2.5-3)*h =2.5*800=2000 mm –distanţa dintre rigidizări
Dimensionarea treptei inferioare a stâlpului

Secţiunea I-I
Mmax=-666.59 kNm
Taf =93.7 kN
Naf =555.8 kN
Nmax =436.6 kN
Maf =-86.74 kNm
Taf =19.65 kN
e=(bi-bs)/2=(1150-800)/2=175 mm
Ix=
Predimensionarea secţiunii
λx = l /i =l /(αX*h )=10770/(0.45*1150)=20.8
h =bi=1150 mm
b=l /( αy * λx)=4500/0.25*21.75=828 mm
Unde αX, αy sunt coeficienţii razelor de giraţie
αX = ix/hi=(0.40-0.45)=0.45
αy = iy/b=(0.22-0.26)=0.25

ρx=Wx/A=2* αX *hi=2*0.45²*800=32.4
e = Mmax/Naf =234.75/98.3=2.38m=239 [cm]
e/ρx =239/32.4=7.4
,λx=21.75
φx=0.17 -Anexa 12.3 Construcţii metalice Siminea
Anec =Nmax/ (φex*R)=261.34*10³/(0.17*210)=7320 mm²=73.2 cm²
ti h /100 =800/100=8 mm
OL 37 R= 2100 daN/cm
Rf=1300 daN/ cm
Se propune secţiunea treptei superioare a stâlpului având următoarele
caracteristici:
 h = h + 2*t=800+2*15=830 mm
 b =250 mm
 t = 15 mm
 ti = 10 mm
 A=2*b*t+ h *ti=2*250*15+800*10=15500mm²=155 cm²
 Ix = Ixi+2*Ixt+2*At*y²gt=10*800³/12+2*(250*15³/12+250*15*408²)=
=1.675*10 mm
 Iy =Iyi+2*Iyt=800*10³/12+2*15*250³/12=0.039*10 mm
 ix = = =328.73 mm

 iy= = =50.16 mm
 Wx = Ix/ymax =1.675*10 /415=4.03*10 mm³
 Wy = Iy/xmax =0.039*10 /125=0.312*10 mm
-Verificarea condiţiei de zvelteţe
λx,y=l /i λa=120
λx=7830/328.73=23.82<120
λy=4500/50.16= 89.7 <120
φx=0.987
φy=0.689
-Verificarea condiţiei de rezistenţă
materialul OL 37 R =2100 daN/cm
Rf=1300 daN/cm
σ=Naf/A+Mmax/Wx=98.3*10³/155*10²+234.75*10 /4.03*10 =
=64.59 N/mm² R=210 N/ mm²
σ=Nmax/A+Maf/Wx=350.71*10³/155*10²+234.75*10 /4.03*10 =
=80.87N/mm² R=210 N/ mm²
τ=Tmax/(h *ti)=93.7*10³/(800*10)=11.71 Rf=130 N/mm²
Verificarea condiţiei de rezistenţă în dreptul legăturii dintre inimă şi talpă
σ=Naf/A+(Mmax/Ix)*φ=98.3*10³/155*10²+(234.75*10 /1.675*10 )*400=
=62.4 N/ mm²<210N/ mm²
φ=h /2=800/2=400
σech= = =65.6 N/ mm² 1.1*R=1.1*210=231 N/
mm²
τ=Taf/((h *ti)=11.71 N/ mm²
Verificarea stabilităţii generale a secţiunii
σ=N/( φ*A)+cx*Mx/{ φg*(1+σ/σE)*Wx}=
=98.3*10³/(0.689*155*10²)+0.548*234.75*10 /{0.83*(1-6.34/3598.3)*
* 4.03*10 =47.73 N/mm²
în care:
N=Naf=98.3*10³N/ mm²
φ=min{ φx, φy}=min{0.987;0.689}=0.689
cx= 0.548 STAS 10108/0-78 Tabel (M2/M1=0)
Mx=Mmax=234.75*10 Nmm
φg= 0.830 coeficient în funcţie de λtr
λtr=μ *l/iy=0.7*4500/50.16=62.8
l=Hs=4500mm
μ=0.7
iy= 50.16 mm raza de inerţie a tălpii mai comprimate în raport cu y-y
σ=Naf/A=98300/15500=6.34 N/mm²
σE=3598.3 N/mm² efortul critic de flambaj Tabel STAS 10108/0-78 în funcţie
de λx ( λx=23.82 )
Verificarea stabilităţii locale a tălpilor
b /t =120/15 = 8 k1 =14
b =(b-ti)/2=(250-10)/2 =120 mm
k1= 14 Tabel STAS 10108/0-78
Verificarea stabilităţii locale a inimii
Eforturi unitare la extremităţile inimii
σ =Naf/A-(Mmax/Ix)*(h /2)=
=98.3*10³/155*10²- (234.75*10 /1.675*10 )*(800/2)=
=6.34-56.06=-49.72N/mm²
σ =Naf/A+(Mmax/Ix)*(h /2)=
= 98.3*10³/155*10²+(234.75*10 /1.675*10 )*(800/2)=
=6.34+56.06=62.4 N/mm²
Ψ=(σ-σ )/σ=(-49.72-62.4)/(-49.72)=2.255 1 h0/ti=800/10=80 100*
=

=100* =110.75
Nu este necesară rigidizarearea longitudinală
k3=450 Tabel
β=0.07*τ*k3/σ =0.07*11.72*450/62.4=5.9
τ=Taf/(h *ti) =11.71 N/ mm²

Rigidizarea treptei superioare


h /ti=80>70* =70* =70
se prevăd rigidizări transversale pe inima treptei superioare
R=21 daN/mm²
h0=h =800 mm
tr= 8 mm grosimea rigidizărilor
tr =120/15=8
tr>0.75*ti =0.75*10 =7.5 mm Se ia: tr = 8 mm
br>10*ti =100mm Se ia: br=120mm
d=(2.5-3)*h =2.5*800=2000 mm –distanţa dintre rigidizări
Ramurile treptei inferioare a secţiunii stâlpului sunt realizate din secţiuni
compuse :dublu T
-A=
-Ar=
-Ix=
-Iy=
-ix=
-ix=
-iy=
-Wx=
 Verificarea condiţiei de zvelteţe
λx= 120 ;φ =
λy= 120; φy=
φ =min{ φ ; φy}=

λ = φ = coeficient de flambaj pt. o ramură a treptei


inferioare după direcţia y
i =
 Verificarea de rezistenţă
σ=
 Verificarea de rezistenţă în dreptul legăturii între inimă şi talpă
σ= R

τ= Rf
σech= 1.1*R

DIMENSIONAREA TREPTEI INFERIOARE A STÂLPULUI


Secţiunea I-I
-Mmax=
-Naf=
-Taf=
-Nmax=
-Maf=
-Taf=
Reducerea eforturilor în axa geometrică a treptei inferioare a stâlpului
M
Naf=N
Taf=T
N
M
T
e=(bi-bs)/2=
 Predimensionarea secţiunii
Se propune λy =120(100)
b=
αx=
αy=
e=
λx,propus=
Anec=
Calculul rigidizări la mijlocul inimi
br 10*ti
tr 0,75*ti
 Rigidizări transversale
Dacă ;se prevăd rigidizări transversale
h0=h
R=31.5daN/mm²
br este impus de br de la rigidizarea longitudinala

tr
d 2*h0
d 3*h
h =h /2
Verificarea stabilităţii generale a secţiunii

<0.15R

μ=0.7
l==Hi
 Verificarea stabilităţii ramurilor

N1=Ar*σ1 efortul axial global al secţiunii ramurilor


 Verificarea stabilităţii locale a inimii
φe=φi=h /2

 Verificarea prinderii treptei superioare pe treapta inferioare

Efortul capabil al tălpilor treptei superioare


N
N
R=2100 daN/cm²
A=b*t
Eforturile unitare în sudură
-talpa 1

-talpa 2
a1=a2=0.7*tmin
R =2100 daN/cm²
l1=l1s-a1
l2=l2s-a2
l1s se calculează după stabilirea dimensiunilor din vederea 1-1
CALCULUL PORTALULUI DE FRÂNARE
Schema portalului de frânare

Dimensionarea portalului inferior


 Evaluarea încărcărilor
-Vânt-presiunea Pp
-sucţiune Ps
Solicitările care se transmit prin intermediul portalului superior
W=Pp+Ps
 Pod rulant –frânarea –demararea longitudinală:L
- lovirea podului în opritor: PT
-Suspensie flexibilă , valoarea normată:

-Suspensie rigidă
Gp= greutate pod fără cărucior
Gc= greutate cărucior
Q= capacitatea max. de ridicare
m

m
Lp= deschiderea podului rulant[m]
l=1.15 m distanţa min. a centrului de greutate al căruciorului faţă de
axa şinei
m= masa echivalentă pentru podul rulant
g=10 m/s²
vp=0.7*vmax [m/s] viteza podului rulant în momentul lovirii în opritori
fT =0.2 m comprimarea tamponului
Valoarea de calcul: PT=n0*P
n0=1.3

Calculul bazei stâlpului


Determinarea dimensiunilor plăcii de bază
B=b+2*(t1+c)
t1= se ia aproximativ egal cu grosimea elementului haşurat secţiunea I-I
c=30-50 mm
L=
N=Naf
M=M
Rc=65daN/cm² rezistenţa de calcul a betonului din cuzinetul b.a. Bc10
B,L= multiplu de 50 mm
Calculul grosimii plăcii de bază

Grosimea necesară a plăcii de bază pentru fiecare tip de placă


t=
R=2100 daN/cm² OL 37
20<t<40 mm
Calculul buloanelor de ancoraj
Ma=M *(Lo-L/2)

Întinderea preluată de buloane (2 buc)

T=(α*Lo*B*Rc)/2-Naf

Efortul preluat de un bulon

T1=T/2
Efortul admis în bulon:Ncap.bulon=

T1<Ncap.bulon

Calculul traversei

h= înălţimea trversei
Condiţia de prindere a stâlpului de traverse:
N

S-ar putea să vă placă și