ACUMULATORULUI
HIDRAULIC
Di := 100
[mm]
S := 125
[mm]
v := 0.1
[m/sec]
p3 := 110
p3 := p3 + 1.033
[kg/cm2 ]abs
p3 = 111.033
[kg/cm2 ]abs
p2 := 10
p2 := p2 + 1.033
Q := 40
T1 := 10
[kg/cm2 ]M
[kg/cm2 ]abs
p2 = 11.033
[kg/cm2 ]M
T2 := 50
[grade C]
[kg/cm2 ]abs
[litri/min]
[grade C]
Vw :=
Di
4
S 10
[litri]
CALCULUL
ACUMULATORULUI
HIDRAULIC
Vw = 0.9817
[litri]
0.8 p2 p1 0.9 p2
ca amortizor de soc
0.5 px p1 0.8 px
ca amortizor de pulsatii
0.5 px p1 0.8 px
p1 := 0.9 p2
Se adopta:
[kg/cm2 ]abs
p1 = 9.9297
[kg/cm2 ]abs
p1 = a T2 T1 + p1p
a = b p1p c 1
0.02 p1p + 1
1
2
2
4
b := 488 2065 10 T1 170 10
4
2
2
c := 8233 6794 10 T1 696 10
a = b p1p c
0.02 p1p
0.02 p1p + 1
0.02 p1p
0.02 p1p + 1
p1 = b p1p c
( T2 T1) + p1p
p
+
1
1p
p1 =
p1 0.02 p1p + 1 = b p1p 0.02 p1p + 1 0.02 p1p c T2 T1 + p1p 0.02 p1p + 1
2
CALCULUL
ACUMULATORULUI
HIDRAULIC
2
Notam:
a1 := b 0.02 T2 T1 + 0.02
b1 := b T2 T1 0.02 c T2 T1 0.02 p1 + 1
c1 := p1
2
p1p a1 + p1p b1 + c1 = 0
2
p1p1 :=
b1 + b1 4 a1 c1
p1p2 :=
2 a1
p1p1 = 8.8546
Este valabila solutia:
b1 b1 4 a1 c1
2 a1
p1p2 = 44.8312
p1p := p1p1
[kg/cm2 ]abs
p1p = 8.8546
[kg/cm2 ]abs
pa :=
p3 + p2
2
[kg/cm2]abs.
pa = 61.033
[kg/cm2]abs.
e :=
p2
e = 0.8026
a :=
p1p
p3
p2
a = 10.0637
CALCULUL
ACUMULATORULUI
HIDRAULIC
b :=
p3
b = 12.5395
p1p
:= 0.95
Tm :=
Vw
[secunde]
Q
60
Tm = 1.4726
[secunde]
Tn = 1.25
[secunde]
Tn :=
S
v
10
[secunde]
m exponentul politropic pentru timpul de incarcare cu ulei al acumulatorului (se ia din tabel sau
se calculeaza)
n exponentul politropic pentru timpul de descarcare a uleiului din acumulator (se ia din tabel
sau se calculeaza)
g := 9.8066
ulei := 880
[kg/m3]
apa := 1000
[kg/m3]
apaglicol := 1100
[kg/m3]
W=
d
4
L 10
[kg]
[m/s2 ]
CALCULUL
ACUMULATORULUI
HIDRAULIC
F1 = 0.6
F1 = 0.25
F1 = 0.25
F1 = 0.15
F1 = 0.13
F1 = 0.06
Pompa multiplunjer
F1 = 0.06
1. REZERVA DE ENERGIE
v1 =
Vw
e F
[litri]
Vw = v 1 e F
[litri]
OBSERVATII
1.
Pentru valori mari ale lui "e" (coeficientul presiunii de incarcare a gazului) se poate alege un
CALCULUL
ACUMULATORULUI
HIDRAULIC
acumulator de marime mica;
Daca "e" depaseste 0.9 durata de viata a diafragmei acumulatorului va fi scurta;
Pentru valori mari ale lui "a" (coeficientul presiunii de lucru a uleiului (fluidului de lucru) din
circuit) se poate alege un acumulator de marime mica;
4. Daca coeficientul de compresie a diafragmei acumulatorului "b" devine mare atunci durata de
viata a acestuia va fi scurta. Valori recomandate pentru coeficientul b=p3/p1 de firma sunt date
dupa cum urmeaza:
1 ACUMULATOR INSTALAT VERTICAL
b=4
2 ACUMULATOR INSTALAT ORIZONTAL b=3
Pentru
valori mai mari decat cele indicate se recomanda consulatarea specialistilor firmei producatoare.
5. "m" si "n" trebuiesc alese obligatoriu in functie de presiunea medie a uleiului pa precum si a
timpului de incarcare /descarcare a acumulatorului care se alege din tabele sau se calculeaza cu
relatiile aferente.
6. Daca m>n calculul se va face considerand m=n
2.
3.
p := pa
m :=
Tm = 1.4726
(
)
1.47 if ( 30 p < 40) ( Tm < 15)
1.5 if ( 40 p < 50) ( Tm < 15)
1.52 if ( 50 p < 60) ( Tm < 15)
1.55 if ( 60 p < 70) ( Tm < 15)
1.59 if ( 70 p < 80) ( Tm < 15)
1.62 if ( 80 p < 90) ( Tm < 15)
1.65 if ( 90 p < 100) ( Tm < 15)
1.68 if ( 100 p < 110) ( Tm < 15)
1.72 if ( 110 p < 120) ( Tm < 15)
1.75 if ( 120 p < 130) ( Tm < 15)
1.79 if ( 130 p < 140) ( Tm < 15)
1.82 if ( 140 p < 150) ( Tm < 15)
1.86 if ( 150 p < 160) ( Tm < 15)
1.89 if ( 160 p < 170) ( Tm < 15)
1.93 if ( 170 p < 180) ( Tm < 15)
1.96 if ( 180 p < 190) ( Tm < 15)
2 if ( 190 p < 200) ( Tm < 15)
1.44 if ( 20 p < 30) Tm < 15
CALCULUL
ACUMULATORULUI
HIDRAULIC
)
1.38 if ( p < 20) ( 15 Tm < 30)
1.4 if ( 20 p < 30) ( 15 Tm < 30)
1.43 if ( 30 p < 40) ( 15 Tm < 30)
1.45 if ( 40 p < 50) ( 15 Tm < 30)
1.48 if ( 50 p < 60) ( 15 Tm < 30)
1.51 if ( 60 p < 70) ( 15 Tm < 30)
1.54 if ( 70 p < 80) ( 15 Tm < 30)
1.57 if ( 80 p < 90) ( 15 Tm < 30)
1.6 if ( 90 p < 100) ( 15 Tm < 30)
1.63 if ( 100 p < 110) ( 15 Tm < 30)
1.66 if ( 110 p < 120) ( 15 Tm < 30)
1.7 if ( 120 p < 130) ( 15 Tm < 30)
1.73 if ( 130 p < 140) ( 15 Tm < 30)
1.76 if ( 140 p < 150) ( 15 Tm < 30)
1.8 if ( 150 p < 160) ( 15 Tm < 30)
1.83 if ( 160 p < 170) ( 15 Tm < 30)
1.87 if ( 170 p < 180) ( 15 Tm < 30)
1.9 if ( 180 p < 190) ( 15 Tm < 30)
1.93 if ( 190 p < 200) ( 15 Tm < 30)
1.34 if ( p < 20) ( 30 Tm < 60)
1.35 if ( 20 p < 30) ( 30 Tm < 60)
1.38 if ( 30 p < 40) ( 30 Tm < 60)
1.4 if ( 40 p < 50) ( 30 Tm < 60)
1.43 if ( 50 p < 60) ( 30 Tm < 60)
1.45 if ( 60 p < 70) ( 30 Tm < 60)
1.48 if ( 70 p < 80) ( 30 Tm < 60)
1.51 if ( 80 p < 90) ( 30 Tm < 60)
1.54 if ( 90 p < 100) ( 30 Tm < 60)
CALCULUL
ACUMULATORULUI
HIDRAULIC
(
)
1.66 if ( 130 p < 140) ( 30 Tm < 60)
1.7 if ( 140 p < 150) ( 30 Tm < 60)
1.73 if ( 150 p < 160) ( 30 Tm < 60)
1.76 if ( 160 p < 170) ( 30 Tm < 60)
1.8 if ( 170 p < 180) ( 30 Tm < 60)
1.83 if ( 180 p < 190) ( 30 Tm < 60)
1.86 if ( 190 p < 200) ( 30 Tm < 60)
1.29 if ( p < 20) ( 60 Tm < 120)
1.31 if ( 20 p < 30) ( 60 Tm < 120)
1.33 if ( 30 p < 40) ( 60 Tm < 120)
1.35 if ( 40 p < 50) ( 60 Tm < 120)
1.37 if ( 50 p < 60) ( 60 Tm < 120)
1.4 if ( 60 p < 70) ( 60 Tm < 120)
1.42 if ( 70 p < 80) ( 60 Tm < 120)
1.45 if ( 80 p < 90) ( 60 Tm < 120)
1.48 if ( 90 p < 100) ( 60 Tm < 120)
1.51 if ( 100 p < 110) ( 60 Tm < 120)
1.54 if ( 110 p < 120) ( 60 Tm < 120)
1.57 if ( 120 p < 130) ( 60 Tm < 120)
1.6 if ( 130 p < 140) ( 60 Tm < 120)
1.63 if ( 140 p < 150) ( 60 Tm < 120)
1.66 if ( 150 p < 160) ( 60 Tm < 120)
1.69 if ( 160 p < 170) ( 60 Tm < 120)
1.73 if ( 170 p < 180) ( 60 Tm < 120)
(
)
1.63 if ( 120 p < 130) 30 Tm < 60
CALCULUL
ACUMULATORULUI
HIDRAULIC
(
)
1.79 if ( 190 p < 200) ( 60 Tm < 120)
1.24 if ( p < 20) ( 120 Tm < 240)
1.26 if ( 20 p < 30) ( 120 Tm < 240)
1.28 if ( 30 p < 40) ( 120 Tm < 240)
1.3 if ( 40 p < 50) ( 120 Tm < 240)
1.32 if ( 50 p < 60) ( 120 Tm < 240)
1.34 if ( 60 p < 70) ( 120 Tm < 240)
1.37 if ( 70 p < 80) ( 120 Tm < 240)
1.39 if ( 80 p < 90) ( 120 Tm < 240)
1.42 if ( 90 p < 100) ( 120 Tm < 240)
1.45 if ( 100 p < 110) ( 120 Tm < 240)
1.47 if ( 110 p < 120) ( 120 Tm < 240)
1.5 if ( 120 p < 130) ( 120 Tm < 240)
1.53 if ( 130 p < 140) ( 120 Tm < 240)
1.56 if ( 140 p < 150) ( 120 Tm < 240)
1.59 if ( 150 p < 160) ( 120 Tm < 240)
1.62 if ( 160 p < 170) ( 120 Tm < 240)
1.65 if ( 170 p < 180) ( 120 Tm < 240)
1.68 if ( 180 p < 190) ( 120 Tm < 240)
1.72 if ( 190 p < 200) ( 120 Tm < 240)
1.19 if ( p < 20) ( 240 Tm < 480)
1.21 if ( 20 p < 30) ( 240 Tm < 480)
1.22 if ( 30 p < 40) ( 240 Tm < 480)
1.24 if ( 40 p < 50) ( 240 Tm < 480)
1.26 if ( 50 p < 60) ( 240 Tm < 480)
1.28 if ( 60 p < 70) ( 240 Tm < 480)
1.31 if ( 70 p < 80) ( 240 Tm < 480)
1.76 if ( 180 p < 190) 60 Tm < 120
CALCULUL
ACUMULATORULUI
HIDRAULIC
1.31 if ( 70 p < 80) 240 Tm < 480
(
)
1.33 if ( 80 p < 90) ( 240 Tm < 480)
1.35 if ( 90 p < 100) ( 240 Tm < 480)
1.38 if ( 100 p < 110) ( 240 Tm < 480)
1.41 if ( 110 p < 120) ( 240 Tm < 480)
1.43 if ( 120 p < 130) ( 240 Tm < 480)
1.46 if ( 130 p < 140) ( 240 Tm < 480)
1.49 if ( 140 p < 150) ( 240 Tm < 480)
1.52 if ( 150 p < 160) ( 240 Tm < 480)
1.55 if ( 160 p < 170) ( 240 Tm < 480)
1.58 if ( 170 p < 180) ( 240 Tm < 480)
1.61 if ( 180 p < 190) ( 240 Tm < 480)
1.64 if ( 190 p < 200) ( 240 Tm < 480)
1.15 if ( p < 20) ( 480 Tm < 900)
1.16 if ( 20 p < 30) ( 480 Tm < 900)
1.17 if ( 30 p < 40) ( 480 Tm < 900)
1.18 if ( 40 p < 50) ( 480 Tm < 900)
1.2 if ( 50 p < 60) ( 480 Tm < 900)
1.22 if ( 60 p < 70) ( 480 Tm < 900)
1.24 if ( 70 p < 80) ( 480 Tm < 900)
1.27 if ( 80 p < 90) ( 480 Tm < 900)
1.29 if ( 90 p < 100) ( 480 Tm < 900)
1.31 if ( 100 p < 110) ( 480 Tm < 900)
1.34 if ( 110 p < 120) ( 480 Tm < 900)
1.37 if ( 120 p < 130) ( 480 Tm < 900)
1.39 if ( 130 p < 140) ( 480 Tm < 900)
1.42 if ( 140 p < 150) ( 480 Tm < 900)
1.45 if ( 150 p < 160) ( 480 Tm < 900)
(
)
10
CALCULUL
ACUMULATORULUI
HIDRAULIC
(
)
1.56 if ( 190 p < 200) ( 480 Tm < 900)
1.1 if ( p < 20) ( 900 Tm < 1800)
1.11 if ( 20 p < 30) ( 900 Tm < 1800)
1.12 if ( 30 p < 40) ( 900 Tm < 1800)
1.13 if ( 40 p < 50) ( 900 Tm < 1800)
1.15 if ( 50 p < 60) ( 900 Tm < 1800)
1.17 if ( 60 p < 70) ( 900 Tm < 1800)
1.19 if ( 70 p < 80) ( 900 Tm < 1800)
1.21 if ( 80 p < 90) ( 900 Tm < 1800)
1.23 if ( 90 p < 100) ( 900 Tm < 1800)
1.25 if ( 100 p < 110) ( 900 Tm < 1800)
1.27 if ( 110 p < 120) ( 900 Tm < 1800)
1.3 if ( 120 p < 130) ( 900 Tm < 1800)
1.32 if ( 130 p < 140) ( 900 Tm < 1800)
1.35 if ( 140 p < 150) ( 900 Tm < 1800)
1.37 if ( 150 p < 160) ( 900 Tm < 1800)
1.4 if ( 160 p < 170) ( 900 Tm < 1800)
1.43 if ( 170 p < 180) ( 900 Tm < 1800)
1.45 if ( 180 p < 190) ( 900 Tm < 1800)
1.48 if ( 190 p < 200) ( 900 Tm < 1800)
1.05 if ( p < 20) ( 1800 Tm)
1.05 if ( 20 p < 30) ( 1800 Tm)
1.06 if ( 30 p < 40) ( 1800 Tm)
1.07 if ( 40 p < 50) ( 1800 Tm)
1.09 if ( 50 p < 60) ( 1800 Tm)
1.53 if ( 180 p < 190) 480 Tm < 900
11
CALCULUL
ACUMULATORULUI
HIDRAULIC
1.09 if ( 50 p < 60) 1800 Tm
12
(
)
1.14 if ( 80 p < 90) ( 1800 Tm)
1.16 if ( 90 p < 100) ( 1800 Tm)
1.18 if ( 100 p < 110) ( 1800 Tm)
1.2 if ( 110 p < 120) ( 1800 Tm)
1.22 if ( 120 p < 130) ( 1800 Tm)
1.24 if ( 130 p < 140) ( 1800 Tm)
1.27 if ( 140 p < 150) ( 1800 Tm)
1.29 if ( 150 p < 160) ( 1800 Tm)
1.31 if ( 160 p < 170) ( 1800 Tm)
1.34 if ( 170 p < 180) ( 1800 Tm)
1.36 if ( 180 p < 190) ( 1800 Tm)
1.39 if ( 190 p < 200) ( 1800 Tm)
1.12 if ( 70 p < 80) 1800 Tm
m = 1.55
Tn = 1.25
CALCULUL
ACUMULATORULUI
HIDRAULIC
n :=
(
)
1.47 if ( 30 p < 40) ( Tn < 15)
1.5 if ( 40 p < 50) ( Tn < 15)
1.52 if ( 50 p < 60) ( Tn < 15)
1.55 if ( 60 p < 70) ( Tn < 15)
1.59 if ( 70 p < 80) ( Tn < 15)
1.62 if ( 80 p < 90) ( Tn < 15)
1.65 if ( 90 p < 100) ( Tn < 15)
1.68 if ( 100 p < 110) ( Tn < 15)
1.72 if ( 110 p < 120) ( Tn < 15)
1.75 if ( 120 p < 130) ( Tn < 15)
1.79 if ( 130 p < 140) ( Tn < 15)
1.82 if ( 140 p < 150) ( Tn < 15)
1.86 if ( 150 p < 160) ( Tn < 15)
1.89 if ( 160 p < 170) ( Tn < 15)
1.93 if ( 170 p < 180) ( Tn < 15)
1.96 if ( 180 p < 190) ( Tn < 15)
2 if ( 190 p < 200) ( Tn < 15)
1.38 if ( p < 20) ( 15 Tn < 30)
1.4 if ( 20 p < 30) ( 15 Tn < 30)
1.43 if ( 30 p < 40) ( 15 Tn < 30)
1.45 if ( 40 p < 50) ( 15 Tn < 30)
1.48 if ( 50 p < 60) ( 15 Tn < 30)
1.51 if ( 60 p < 70) ( 15 Tn < 30)
1.54 if ( 70 p < 80) ( 15 Tn < 30)
1.57 if ( 80 p < 90) ( 15 Tn < 30)
1.6 if ( 90 p < 100) ( 15 Tn < 30)
1.44 if ( 20 p < 30) Tn < 15
13
CALCULUL
ACUMULATORULUI
HIDRAULIC
1.6 if ( 90 p < 100) 15 Tn < 30
(
)
1.66 if ( 110 p < 120) ( 15 Tn < 30)
1.7 if ( 120 p < 130) ( 15 Tn < 30)
1.73 if ( 130 p < 140) ( 15 Tn < 30)
1.76 if ( 140 p < 150) ( 15 Tn < 30)
1.8 if ( 150 p < 160) ( 15 Tn < 30)
1.83 if ( 160 p < 170) ( 15 Tn < 30)
1.87 if ( 170 p < 180) ( 15 Tn < 30)
1.9 if ( 180 p < 190) ( 15 Tn < 30)
1.93 if ( 190 p < 200) ( 15 Tn < 30)
1.34 if ( p < 20) ( 30 Tn < 60)
1.35 if ( 20 p < 30) ( 30 Tn < 60)
1.38 if ( 30 p < 40) ( 30 Tn < 60)
1.4 if ( 40 p < 50) ( 30 Tn < 60)
1.43 if ( 50 p < 60) ( 30 Tn < 60)
1.45 if ( 60 p < 70) ( 30 Tn < 60)
1.48 if ( 70 p < 80) ( 30 Tn < 60)
1.51 if ( 80 p < 90) ( 30 Tn < 60)
1.54 if ( 90 p < 100) ( 30 Tn < 60)
1.57 if ( 100 p < 110) ( 30 Tn < 60)
1.6 if ( 110 p < 120) ( 30 Tn < 60)
1.63 if ( 120 p < 130) ( 30 Tn < 60)
1.66 if ( 130 p < 140) ( 30 Tn < 60)
1.7 if ( 140 p < 150) ( 30 Tn < 60)
1.73 if ( 150 p < 160) ( 30 Tn < 60)
1.76 if ( 160 p < 170) ( 30 Tn < 60)
1.8 if ( 170 p < 180) ( 30 Tn < 60)
1.83 if ( 180 p < 190) ( 30 T < 60)
1.63 if ( 100 p < 110) 15 Tn < 30
14
CALCULUL
ACUMULATORULUI
HIDRAULIC
(
)
1.86 if ( 190 p < 200) ( 30 Tn < 60)
1.29 if ( p < 20) ( 60 Tn < 120)
1.31 if ( 20 p < 30) ( 60 Tn < 120)
1.33 if ( 30 p < 40) ( 60 Tn < 120)
1.35 if ( 40 p < 50) ( 60 Tn < 120)
1.37 if ( 50 p < 60) ( 60 Tn < 120)
1.4 if ( 60 p < 70) ( 60 Tn < 120)
1.42 if ( 70 p < 80) ( 60 Tn < 120)
1.45 if ( 80 p < 90) ( 60 Tn < 120)
1.48 if ( 90 p < 100) ( 60 Tn < 120)
1.51 if ( 100 p < 110) ( 60 Tn < 120)
1.54 if ( 110 p < 120) ( 60 Tn < 120)
1.57 if ( 120 p < 130) ( 60 Tn < 120)
1.6 if ( 130 p < 140) ( 60 Tn < 120)
1.63 if ( 140 p < 150) ( 60 Tn < 120)
1.66 if ( 150 p < 160) ( 60 Tn < 120)
1.69 if ( 160 p < 170) ( 60 Tn < 120)
1.73 if ( 170 p < 180) ( 60 Tn < 120)
1.76 if ( 180 p < 190) ( 60 Tn < 120)
1.79 if ( 190 p < 200) ( 60 Tn < 120)
1.24 if ( p < 20) ( 120 Tn < 240)
1.26 if ( 20 p < 30) ( 120 Tn < 240)
1.28 if ( 30 p < 40) ( 120 Tn < 240)
1.3 if ( 40 p < 50) ( 120 Tn < 240)
1.32 if ( 50 p < 60) ( 120 Tn < 240)
1.34 if ( 60 p < 70) ( 120 Tn < 240)
1.37 if ( 70 p < 80) ( 120 Tn < 240)
1.83 if ( 180 p < 190) 30 Tn < 60
15
CALCULUL
ACUMULATORULUI
HIDRAULIC
(
)
n
1.39 if ( 80 p < 90) ( 120 Tn < 240)
1.42 if ( 90 p < 100) ( 120 Tn < 240)
1.45 if ( 100 p < 110) ( 120 Tn < 240)
1.47 if ( 110 p < 120) ( 120 Tn < 240)
1.5 if ( 120 p < 130) ( 120 Tn < 240)
1.53 if ( 130 p < 140) ( 120 Tn < 240)
1.56 if ( 140 p < 150) ( 120 Tn < 240)
1.59 if ( 150 p < 160) ( 120 Tn < 240)
1.62 if ( 160 p < 170) ( 120 Tn < 240)
1.65 if ( 170 p < 180) ( 120 Tn < 240)
1.68 if ( 180 p < 190) ( 120 Tn < 240)
1.72 if ( 190 p < 200) ( 120 Tn < 240)
1.19 if ( p < 20) ( 240 Tn < 480)
1.21 if ( 20 p < 30) ( 240 Tn < 480)
1.22 if ( 30 p < 40) ( 240 Tn < 480)
1.24 if ( 40 p < 50) ( 240 Tn < 480)
1.26 if ( 50 p < 60) ( 240 Tn < 480)
1.28 if ( 60 p < 70) ( 240 Tn < 480)
1.31 if ( 70 p < 80) ( 240 Tn < 480)
1.33 if ( 80 p < 90) ( 240 Tn < 480)
1.35 if ( 90 p < 100) ( 240 Tn < 480)
1.38 if ( 100 p < 110) ( 240 Tn < 480)
1.41 if ( 110 p < 120) ( 240 Tn < 480)
1.43 if ( 120 p < 130) ( 240 Tn < 480)
1.46 if ( 130 p < 140) ( 240 Tn < 480)
1.49 if ( 140 p < 150) ( 240 Tn < 480)
1.52 if ( 150 p < 160) ( 240 Tn < 480)
1.55 if ( 160 p < 170) ( 240 T < 480)
16
CALCULUL
ACUMULATORULUI
HIDRAULIC
(
)
1.58 if ( 170 p < 180) ( 240 Tn < 480)
1.61 if ( 180 p < 190) ( 240 Tn < 480)
1.64 if ( 190 p < 200) ( 240 Tn < 480)
1.15 if ( p < 20) ( 480 Tn < 900)
1.16 if ( 20 p < 30) ( 480 Tn < 900)
1.17 if ( 30 p < 40) ( 480 Tn < 900)
1.18 if ( 40 p < 50) ( 480 Tn < 900)
1.2 if ( 50 p < 60) ( 480 Tn < 900)
1.22 if ( 60 p < 70) ( 480 Tn < 900)
1.24 if ( 70 p < 80) ( 480 Tn < 900)
1.27 if ( 80 p < 90) ( 480 Tn < 900)
1.29 if ( 90 p < 100) ( 480 Tn < 900)
1.31 if ( 100 p < 110) ( 480 Tn < 900)
1.34 if ( 110 p < 120) ( 480 Tn < 900)
1.37 if ( 120 p < 130) ( 480 Tn < 900)
1.39 if ( 130 p < 140) ( 480 Tn < 900)
1.42 if ( 140 p < 150) ( 480 Tn < 900)
1.45 if ( 150 p < 160) ( 480 Tn < 900)
1.47 if ( 160 p < 170) ( 480 Tn < 900)
1.5 if ( 170 p < 180) ( 480 Tn < 900)
1.53 if ( 180 p < 190) ( 480 Tn < 900)
1.56 if ( 190 p < 200) ( 480 Tn < 900)
1.1 if ( p < 20) ( 900 Tn < 1800)
1.11 if ( 20 p < 30) ( 900 Tn < 1800)
1.12 if ( 30 p < 40) ( 900 Tn < 1800)
1.13 if ( 40 p < 50) ( 900 Tn < 1800)
1.15 if ( 50 p < 60) ( 900 Tn < 1800)
(
)
1.55 if ( 160 p < 170) 240 Tn < 480
17
CALCULUL
ACUMULATORULUI
HIDRAULIC
(
)
1.19 if ( 70 p < 80) ( 900 Tn < 1800)
1.21 if ( 80 p < 90) ( 900 Tn < 1800)
1.23 if ( 90 p < 100) ( 900 Tn < 1800)
1.25 if ( 100 p < 110) ( 900 Tn < 1800)
1.27 if ( 110 p < 120) ( 900 Tn < 1800)
1.3 if ( 120 p < 130) ( 900 Tn < 1800)
1.32 if ( 130 p < 140) ( 900 Tn < 1800)
1.35 if ( 140 p < 150) ( 900 Tn < 1800)
1.37 if ( 150 p < 160) ( 900 Tn < 1800)
1.4 if ( 160 p < 170) ( 900 Tn < 1800)
1.43 if ( 170 p < 180) ( 900 Tn < 1800)
1.45 if ( 180 p < 190) ( 900 Tn < 1800)
1.48 if ( 190 p < 200) ( 900 Tn < 1800)
1.05 if ( p < 20) ( 1800 Tn)
1.05 if ( 20 p < 30) ( 1800 Tn)
1.06 if ( 30 p < 40) ( 1800 Tn)
1.07 if ( 40 p < 50) ( 1800 Tn)
1.09 if ( 50 p < 60) ( 1800 Tn)
1.1 if ( 60 p < 70) ( 1800 Tn)
1.12 if ( 70 p < 80) ( 1800 Tn)
1.14 if ( 80 p < 90) ( 1800 Tn)
1.16 if ( 90 p < 100) ( 1800 Tn)
1.18 if ( 100 p < 110) ( 1800 Tn)
1.2 if ( 110 p < 120) ( 1800 Tn)
1.22 if ( 120 p < 130) ( 1800 Tn)
1.24 if ( 130 p < 140) ( 1800 Tn)
1.27 if ( 140 p < 150) ( 1800 Tn)
1.17 if ( 60 p < 70) 900 Tn < 1800
18
CALCULUL
ACUMULATORULUI
HIDRAULIC
1.27 if ( 140 p < 150) 1800 Tn
1.29 if
1.31 if
1.34 if
1.36 if
1.39 if
19
(
)
( 150 p < 160) ( 1800 Tn)
( 160 p < 170) ( 1800 Tn)
( 170 p < 180) ( 1800 Tn)
( 180 p < 190) ( 1800 Tn)
( 190 p < 200) ( 1800 Tn)
m = 1.55
n = 1.55
( )
18 0.45 + log Tm
p + 95
mc = 1.643
( ))
( )
( )
18 0.45 + log Tn
p + 95
nc = 1.6529
F :=
a 1
1
F = 0.7745
Fc :=
nc
1
1
mc
Fc = 0.7463
CALCULUL
ACUMULATORULUI
HIDRAULIC
20
1. REZERVA DE ENERGIE
v 1 :=
Vw
[litri]
e F
v 1 = 1.6625
[litri]
Qd :=
Vw
Tn
[litri/sec]
Qd = 0.7854
[litri/sec]
Din catalog se alege sau se aleg dupa caz acumulatorii care sa satisfaca conditia de debit
determinata mai sus.