Documente Academic
Documente Profesional
Documente Cultură
0.681 ng/mL < AMH 2.27 ng/mL 20 (12%) 95 (56.9%) 52 (31.1%) 167
Concluzie:
Pentru o pacient cu valori AMH 0.681 ng/mL, probabilitatea de a avea un AFC
sczut (0-7) este de 63%, probabilitatea de a avea un AFC mediu (8-15) este de 32%,
iar probabilitatea de a avea un AFC crescut (> 15) este de numai de 4.4%.
Pentru valorile AMH >2.27 ng/mL, probabilitatea de a avea un AFC >15 este de 75%,
probabilitatea de a avea un AFC mediu este de 24% iar probabilitatea de a avea un
AFC sczut este de numai 1.4%12.
Nu au fost stabilite intervale de referin pentru copii i femei > 50 ani. n scop
orientativ, menionm valorile raportate de LabCorp (Laboratory Corporation of
America)13:
Copii:
fetie 0-6 ani: 0.53-7.78 ng/mL
fetie 7-19 ani: 1.05-12.86 ng/mL
biei 0-6 ani: 32.77-262.69 ng/mL
biei 7-10 ani: 45.26-191.34 ng/mL
Femeile aflate la menopauz, precum i cele cu insuficien ovarian prematur de
orice cauz (inclusiv cea indus de chimioterapie) prezint valori AMH sczute,
adesea sub limita de detecie a metodei.
Tumorile granuloasei ovariene secret pe lng inhibinele A, B i AMH, astfel c
nivelurile crescute ale acestor markeri pot indica prezena unui neoplasm de acest tip
la femeile cu mas ovarian. Dup un tratament eficient markerii nregistreaz o
scdere semnificativ; nivelurile n cretere constituie un indicator de
recuren/progresie a bolii.
La copiii cu intersexualitate valorile AMH crescute sugereaz prezena esutului
testicular n timp ce nivelurile nedetectabile o infirm.
La bieii cu testicul absent n scrot valorile AMH detectabile indic cel mai probabil
criptorhidism pe cnd nivelurile nedetectabile sunt sugestive pentru anorhie sau
pentru o gonad nefuncional localizat anormal9.
Limita de detecie 0.01 ng/mL12.
Limite i interferene
Valorile obinute la testarea AMH trebuie corelate ntotdeauna cu tabloul clinic i cu
rezulatele celorlalte investigaii.
Interferene analitice
Pot produce interferene cu unele componente ale kit-ului i conduce
la rezultate neconcludente urmtoarele:
tratamentul cu biotin n doze mari (>5 mg/zi); de aceea se recomand ca
recoltarea de snge s se fac dup minimum 8 ore de la ultima administrare;
titrurile foarte crescute de anticorpi anti-streptavidin i anti-ruteniu12.
Bibliografie
1. Jenny A Visser, et al. Anti-Mllerian hormone: a new marker for ovarian
function. Reproduction (2006), 131 1-9.
2. Durlinger ALL et al. Control of primordial follicle recruitment by Anti-Mllerian hormone in the
mouse ovary. Endocrinology 1999, 140.5789-5796.
3. Durlinger ALL et al. Regulation of ovarian function: the role of Anti-Mllerian
hormone. Reproduction (2002), 124, 601-609.
4. Van Rooij IA, et al. Anti-Mllerian hormone is a promising predictor of for the ocurrence of the
menopausal transition. Menopause 2004, 11.601-606.
5. Van Rooij IA, et al. Serum anti-Mllerian hormone levels best reflect the reproductive decline with age
in normal women with proven fertility: a longitudinal study. Fertility and Sterility, 2005, 83, 979-987.
6. Seifer DB, et al. Early follicular serum mllerian- inhibiting substance levels are associated with
ovarian response during assisted reproductive technology cycles. Fertility and Sterility, 2002, 77, 468-
471.
7. Van Rooij IA, et al. Serum Anti-Mllerian hormone levels: a novel measure of ovarian reserve. Human
Reproduction, 2002, 17, 3065-3071.
8. Fleming R, et al. Metformin reduces serum mllerian- inhibiting substance levels in women with
polycystic ovary syndrome afeter protracted treatment. Fertility and Sterility, 2005, 83, 130-160.
9. Mayo Clinic, Mayo Medical Laboratories. Reference Laboratory Services for Health Care
Organizations. Test Catalog. Antimullerian Hormone (AMH), Serum.
www.mayomedicallaboratories.com 2015. Ref Type: Internet
10. di Clemente N, Jamin SP, Lugovskoy A, et al. Processing of anti-mullerian hormone regulates receptor
activation by a mechanism distinct from TGF-beta. Mol Endocrinol. 2010 Nov;24(11):2193-206.
11. Gassner D, Jung R. First fully-automated immunoassay for anti- Mllerian hormone. Clin Chem Lab
Med. 2014; 52(8):1143-52.
12. Laborator Synevo. Referinele specifice tehnologiei de lucru utilizate. 2015. Ref Type: Catalog.
13. Laboratory Corporation of America. Directory of Services and Interpretive Guide. Anti- Mllerian
hormone (AMH). www.labcorp.com 2015. Ref Type: Internet Communication.